Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

SU-E-T-378: Evaluation of An Analytical Model for the Inter-Seed Attenuation Effect in 103-Pd Multi-Seed Implant Brachytherapy

Purpose: Brachytherapy treatment planning systems based on TG-43 protocol calculate the dose in water and neglects the heterogeneity effect of seeds in multi-seed implant brachytherapy. In this research, the accuracy of a novel analytical model that we propose for the inter-seed attenuation effect (ISA) for 103-Pd seed model is evaluated. Methods: In the analytical model, dose perturbation due to the ISA effect for each seed in an LDR multi-seed implant for 103-Pd is calculated by assuming that the seed of interest is active and the other surrounding seeds are inactive. The cumulative dosimetric effect of all seeds is then summed using the superposition principle. The model is based on pre Monte Carlo (MC) simulated 3D kernels of the dose perturbations caused by the ISA effect. The cumulative ISA effect due to multiple surrounding seeds is obtained by a simple multiplication of the individual ISA effect by each seed, the effect of which is determined by the distance from the seed of interest. This novel algorithm is then compared with full MC water-based simulations (FMCW). Results: The results show that the dose perturbation model we propose is in excellent agreement with the FMCW values for a case with three seeds separated by 1 cm. The average difference of the model and the FMCW simulations was less than 8%±2%. Conclusion: Using the proposed novel analytical ISA effect model, one could expedite the corrections due to the ISA dose perturbation effects during permanent seed 103-Pd brachytherapy planning with minimal increase in time since the model is based on multiplications and superposition. This model can be applied, in principle, to any other brachytherapy seeds. Further work is necessary to validate this model on a more complicated geometry as well.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-03: Integrating Novel Electromagnetic Tracking Hollow Needle Assistance in Permanent Implant Brachytherapy Procedures

Purpose: To report on the results of a complete permanent implant brachytherapy procedure assisted by an electromagnetic (EM) hollow needle possessing both 3D tracking and seed drop detection abilities. Methods: End-to-end in-phantom EM-assisted LDR procedures were conducted. The novel system consisted of an EM tracking apparatus (NDI Aurora V2, Planar Field Generator), a 3D US scanner (Philips CX50), a hollow needle prototype allowing 3D tracking and seed drop detection and a specially designed treatment planning software (Philips Healthcare). A tungsten-doped 30 cc spherical agarose prostate immersed in gelatin was used for the treatment. A cylindrical shape of 0.8 cc was carved along its diameter to mimic the urethra. An initial plan of 26 needles and 47 seeds was established with the system. The plan was delivered with the EM-tracked hollow needle, and individual seed drop locations were recorded on the fly. The phantom was subsequently imaged with a CT scanner from which seed positions and contour definitions were obtained. The DVHs were then independently recomputed and compared with those produced by the planning system, both before and after the treatment. Results: Of the 47 seeds, 45 (96%) were detected by the EM technology embedded in the hollow needle design. The executed plan (from CT analysis) differed from the initial plan by 2%, 14% and 8% respectively in terms of V100, D90 and V150 for the prostate, and by 8%, 7% and 10% respectively in terms of D5, V100 and V120 for the urethra. Conclusion: The average DVH deviations between initial and executed plans were within a 5% tolerance imposed for this proof-of-concept assessment. This relatively good concordance demonstrates the feasibility and potential benefits of combining EM tracking and seed drop detection for real-time dosimetry validation and assistance in permanent implant brachytherapy procedures. This project has been entirely funded by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-14: Optimization of Dosimetric Guidelines for Accelerated Partial Breast Irradiation (APBI) Using the Strut-Adjusted Volume Implant (SAVI)

Purpose: Treatment planning guidelines for accelerated partial breast irradiation (ABPI) using the strut-adjusted volume implant (SAVI) are inconsistent between the manufacturer and NSABP B-39/RTOG 0413 protocol. Furthermore neither set of guidelines accounts for different applicator sizes. The purpose of this work is to establish guidelines specific to the SAVI that are based on clinically achievable dose distributions. Methods: Sixty-two consecutive patients were implanted with a SAVI and prescribed to receive 34 Gy in 10 fractions twice daily using high dose-rate (HDR) Ir-192 brachytherapy. The target (PTV-EVAL) was defined per NSABP. The treatments were planned and evaluated using a combination of dosimetric planning goals provided by the NSABP, the manufacturer, and our prior clinical experience. Parameters evaluated included maximum doses to skin and ribs, and volumes of PTV-EVAL receiving 90%, 95%, 100%, 150%, and 200% of the prescription (V90, etc). All target parameters were evaluated for correlation with device size using the Pearson correlation coefficient. Revised dosimetric guidelines for target coverage and heterogeneity were determined from this population. Results: Revised guidelines for minimum target coverage (ideal in parentheses): V90≥95%(97%), V95≥90%(95%), V100≥88%(91%). The only dosimetric parameters that were significantly correlated (p<0.05) with device size were V150 and V200. Heterogeneity criteria were revised for the 6–1 Mini/6-1 applicators to V150≤30cc and V200≤15cc, and unchanged for the other sizes. Re-evaluation of patient plans showed 90% (56/62) met the revised minimum guidelines and 76% (47/62) met the ideal guidelines. All and 56/62 patients met our institutional guidelines for maximum skin and rib dose, respectively. Conclusions: We have optimized dosimetric guidelines for the SAVI applicators, and found that implementation of these revised guidelines for SAVI treatment planning yielded target coverage exceeding that required by existing guidelines while preserving heterogeneity constraints and minimizing dose to organs at risk.

60 APPLIED LIFE SCIENCES↗

SU-F-T-40: Can CBCT Images Be Used for Volume Studies of Prostate Seed Implants for Boost Treatment?

Purpose: In our clinic, the planning CT is used for definitive and boost low-dose-rate (LDR) brachytherapy treatments to determine the ultrasound volume in the operating room (OR) at the time of the implant. While the CT overestimation of OR volume is known, a larger estimation discrepancy has been observed for boost treatments. A possible reason is the prostate size reduction during EBRT for boost patients. Since cone-beam CT (CBCT) is often used as routine imaging guidance of EBRT, this prostate volume change may be captured. This study investigates if CBCT taken during EBRT includes the volume change information and therefore beats CT in estimating the prostate OR volumes. Methods: 9 prostate patients treated with EBRT (45Gy in 1.8Gy per fractions to the whole pelvis) and I-125 seed implants (108Gy) were involved in this study. During EBRT, CBCT image guidance was performed on a weekly basis. For each patient, the prostate volumes on the first and the last available CBCT images were manually contoured by a physician. These volumes were then compared to each other and with the contoured volumes from the planning CT and from the ultrasound images in the OR. Results: The first and the last CBCT images did not show significant prostate volume change. Their average +/− standard deviation of prostate volumes were 24.4cc+/−14.6cc and 29.9cc+/−16.1cc, respectively (T-test p=0.68). The ratio of the OR volume to the last CBCT (0.71+/−0.21) was not significantly different from the ratio of OR volumes to the planning CT (0.61+/−0.13) (p=0.25). Conclusion: In this study, CBCT does not show significant prostate volume changes during EBRT. CBCT and CT volumes are quite consistent and no improvement of volume estimation using CBCT is observed. The advantage of CBCT as a replacement of CT for volume study of boost LDR brachytherapy is limited.

60 APPLIED LIFE SCIENCES↗

SU-F-T-444: Quality Improvement Review of Radiation Therapy Treatment Planning in the Presence of Dental Implants

Purpose: To quantify and compare the effect of metallic dental implants (MDI) on dose distributions calculated using Collapsed Cone Convolution Superposition (CCCS) algorithm or a Monte Carlo algorithm (with and without correcting for the density of the MDI). Methods: Seven previously treated patients to the head and neck region were included in this study. The MDI and the streaking artifacts on the CT images were carefully contoured. For each patient a plan was optimized and calculated using the Pinnacle3 treatment planning system (TPS). For each patient two dose calculations were performed, a) with the densities of the MDI and CT artifacts overridden (12 g/cc and 1 g/cc respectively) and b) without density overrides. The plans were then exported to the Monaco TPS and recalculated using Monte Carlo dose calculation algorithm. The changes in dose to PTVs and surrounding Regions of Interest (ROIs) were examined between all plans. Results: The Monte Carlo dose calculation indicated that PTVs received 6% lower dose than the CCCS algorithm predicted. In some cases, the Monte Carlo algorithm indicated that surrounding ROIs received higher dose (up to a factor of 2). Conclusion: Not properly accounting for dental implants can impact both the high dose regions (PTV) and the low dose regions (OAR). This study implies that if MDI and the artifacts are not appropriately contoured and given the correct density, there is potential significant impact on PTV coverage and OAR maximum doses.

60 APPLIED LIFE SCIENCES↗

Microstructure and magnetooptics of silicon oxide with implanted nickel nanoparticles

Metallic nickel nanoparticles of various sizes are formed in a thin near-surface layer in an amorphous SiO{sub 2} matrix during 40-keV Ni{sup +} ion implantation at a dose of (0.25-1.0) Multiplication-Sign 10{sup 17} ions/cm{sup 2}. The micro-structure of the irradiated layer and the crystal structure, morphology, and sizes of nickel particles formed at various irradiation doses are studied by transmission electron microscopy and electron diffraction. The magnetooptical Faraday effect and the magnetic circular dichroism in an ensemble of nickel nanoparticles are studied in the optical range. The permittivity {epsilon} tensor components are calculated for the implanted samples using an effective medium model with allowance for the results of magnetooptical measurements. The spectral dependences of the tensor {epsilon} components are found to be strongly different from those of a continuous metallic nickel film. These differences are related to a disperse structure of the magnetic nickel phase and to a surface plasma resonance in the metal nanoparticles.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high-temperature radiation-resistant rectifier based on p{sup +}-n junctions in 4H-SiC ion-implanted with aluminum

A combination of a high-dose (5 s- 10{sup 16} cm{sup -2}) implantation of Al ions into epitaxial n-type 4H SiC layers grown by chemical deposition from th e vapor phase and rapid (15 s) thermal annealing at 1700-1750 deg. C has been used to form layers with a rectangular impurity profile according to the mechanism of solid-phase epitaxial crystallization. The combined effects of enhanced diffusion of radiation defects after implantation and gettering of defects during annealing bring about an improvement in the quality of the initial material, which ensures an increase in the diffusion length of the minority charge carriers by several times. Metastable states annealed within different temperature ranges are formed in SiC under the effect of irradiation with various particles. Low-temperature annealing of radiation defects increases the radiation and temporal lifetime of devices under irradiation. High-temperature annealing of radiation defects makes it possible to vary the lifetime of nonequilibrium charge carriers, i.e, vary the frequency range of devices. The radiation resistance of SiC-based devices increases as the operation temperature is increased to 500 deg. C.

36 MATERIALS SCIENCE↗

Formation of donor centers upon the annealing of silicon light-emitting structures implanted with oxygen ions

It is found that the implantation of silicon with oxygen ions and subsequent annealing at high temperatures are accompanied by the formation of electrically active donor centers and by the p-n conversion of the conductivity of silicon. The concentration and spatial distribution of these centers depend on the annealing temperature. The results are accounted for by the interaction of oxygen atoms with intrinsic point defects formed upon the annealing of implantation damages.

36 MATERIALS SCIENCE↗

An origin of orange (2 eV) photoluminescence in SiO{sub 2} films implanted with high Si{sup +}-ion doses

The photoluminescence and photoluminescence excitation spectra of SiO{sub 2} films implanted with high (3 at %) Si{sup +}-ion doses are studied in relation to the temperature of postimplantation annealing. It is shown that two photoluminescence bands with peaks at 2.7 and 2 eV are dominant in the spectra. As the annealing temperature is increased, the relation between the intensities of the 2.7 and 2 eV bands changes in favor of the former one. Both of the photoluminescence bands have their main excitation peak at the energy 5.1 eV. The excitation spectrum of the ∼2-eV band exhibits also peaks at 3.8 and 4.6 eV. It is concluded that, in the implanted SiO{sub 2} films, the orange photoluminescence band originates from radiative transitions between levels of centers associated with a deficiency of oxygen (≡Si–Si≡ or =Si:) and the levels of nonbridging oxygen (≡Si–O•)

36 MATERIALS SCIENCE↗

Electron conductivity in GeTe and GeSe upon ion implantation of Bi

This paper presents results on ion implantation of bismuth in GeTe and GeSe films. The conductivity and the thermopower of amorphous chalcogenide films are investigated. Electron conductivity in the films is attained at the Bi implantation doses higher than (1.5–2) × 10{sup 16} cm{sup −2}. In conjunction with the structural modification in the films as revealed Raman spectroscopy, the results suggest the structural re-arrangement of the amorphous network occurs via weakening the bonds of a lower energy. The onset of electron conductivity is hindered by a stronger bond in an alloy. In GeTe, this is the Ge-Ge bond.

36 MATERIALS SCIENCE↗

Temperature dependences of the photoluminescence intensities of centers in silicon implanted with erbium and oxygen ions

Low-temperature photoluminescence in n-Cz-Si after the implantation of erbium ions at an elevated temperature and subsequent implantation of oxygen ions at room temperature is studied. So-called X and W centers formed from self-interstitial silicon atoms, H and P centers containing oxygen atoms, and Er centers containing Er{sup 3+} ions are observed in the photoluminescence spectra. The energies of enhancing and quenching of photoluminescence for these centers are determined. These energies are determined for the first time for X and H centers. In the case of P and Er centers, the values of the energies practically coincide with previously published data. For W centers, the energies of the enhancing and quenching of photoluminescence depend on the conditions of the formation of these centers.

36 MATERIALS SCIENCE↗

Investigation of Ion-Implanted Photosensitive Silicon Structures by Electrochemical Capacitance–Voltage Profiling

The method of electrochemical capacitance–voltage profiling is used to study boron-implanted silicon structures for CCD matrices with backside illumination. A series of specially prepared structures with different energies and doses of ion implantation and also with various materials used for the coating layers (aluminum, silicon oxide, and their combinations) is studied. The profiles of the depth distribution of majority charge carriers of the studied structures are obtained experimentally. Also, using the Poisson equation and the Fredholm equation of the first kind, the distributions of the charge-carrier concentration and of the electric field in the structures are calculated. On the basis of the analysis and comparison of theoretical and experimental concentration profiles, recommendations concerning optimization of the structures’ parameters in order to increase the value of the pulling field and decrease the effect of the surface potential on the transport of charge carriers are suggested.

36 MATERIALS SCIENCE↗

Redistribution of Erbium and Oxygen Recoil Atoms and the Structure of Silicon Thin Surface Layers Formed by High-Dose Argon Implantation through Er and SiO{sub 2} Surface Films

Using analytical high-resolution electron microscopy, the Si structure and the redistribution of Er and O recoil atoms embedded in thin (~10 nm) surface layers by Ar{sup +} implantation with an energy of 250–290 keV and a dose of 1 × 10{sup 16} cm{sup –2} through Er and SiO{sub 2} films, respectively, and subsequent annealing are studied. It is established that Si recrystallization fails at a distance of ~20 nm from the surface, where the erbium concentration of 5 × 10{sup 19} cm{sup –3} critical for failure is achieved at T = 950°C. It disproves the generally accepted model of Er-atom transfer by the recrystallization front into SiO{sub 2} on the surface. Instead, it is shown that the redistribution of O recoil atoms to the initial oxide during annealing for immobile Er atoms provides the formation of surface-inhomogeneous erbium phases in such a way that the oxygen-enriched Er–Si–O phase turns out to be concentrated in the oxide, while the depleted Er–Si phase remains in Si. It explains the partial loss of implanted Er after removal of the oxide together with the Er–Si–O phase. It was shown that the formation of a high density of microtwins (locally up to 10{sup 13} cm{sup –2}) is associated with the formation of Ar bubbles and clusters, which is atypical for (100)–Si recrystallization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure and Properties of Zn-Implanted Si Near-Surface Layer Modification Depending on Irradiation Fluence of {sup 132}Xe{sup 26+} Ions with Energy of 167 MeV

Single-crystal n-Si(100) wafers are implanted with {sup 64}Zn{sup +} ions with an energy of 50 keV and dose of 5 × 10{sup 16} cm{sup –2}. Then the samples are irradiated with {sup 132}Xe{sup 26+} ions with an energy of 167 MeV in the range of fluences from 1 × 10{sup 12} to 5 × 10{sup 14} cm{sup –2}. The surface and cross section of the samples are visualized by scanning electron microscopy and transmission electron microscopy. The distribution of implanted Zn atoms is studied by time-of-flight secondary-ion mass spectrometry. After irradiation with Xe, surface pores and clusters consisting of a Zn–ZnO mixture are observed at the sample surface. In the amorphized subsurface Si layer, zinc and zinc-oxide phases are detected. After irradiation with Xe with a fluence of 5 × 10{sup 14} cm{sup –2}, no zinc or zinc-oxide clusters are detected in the samples by the methods used in the study.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of the Charge State of Xenon Ions on the Depth Distribution Profile Upon Implantation into Silicon

Experimental depth distributions of the concentration of implanted xenon ions depending on their charge state and irradiation energy are presented. Xenon ions in charge states q = 1–20 and energies in the range from 50 to 400 keV are incorporated into single-crystal silicon. Irradiation is performed in the direction not coinciding with the crystallographic axes of the crystal to avoid the channeling effect. The ion fluence varies in the range of 5 × (10{sup 14}–10{sup 15}) ion/cm{sup 2}. The irradiation by singly charged ions and investigation of the samples by Rutherford backscattering spectroscopy is performed using an HVEE acceleration complex at Moscow State University. Multiply charged ions are implanted using a FAMA acceleration complex at the Vinća Institute of Nuclear Sciences. The depth distribution profiles of the incorporated ions are found using Rutherford backscattering spectroscopy. Experimental results are correlated with computer calculations. It is shown that the average projective path of multiply charged ions in most cases is shorter when compared with the average projected path of singly charged ions and the results of computer modeling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On Change in the Silicon Crystal Structure Implanted with Hydrogen Ions during Annealing Based on Three-Crystal X-Ray Diffractometry Data

In this paper, we present the results of a three-crystal X-ray diffractometry (XRD) study of the state of a disturbed layer formed in silicon crystals by implantation of hydrogen ions with energies of 100 + 200 + 300 keV and a total dose of 2 × 10{sup 16} cm{sup –2} during the subsequent heat exposure in the temperature range from 200 to 1100°C. Here, X-ray studies were performed in the three-crystal XRD scheme when the sample under consideration operates as a second stationary crystal with various fixed angular detuning α from the Bragg position while the third (perfect) crystal-analyzer sweeps the angular distribution of radiation diffracted by the second crystal. Based on a comparison of the shape of diffraction and diffuse maxima for the samples under study, a qualitative conclusion about a significant transformation of radiation defects at post-implantation annealing was derived.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation of Nanosized Surface Layers of 03Kh17N12M2 Stainless Steel by Implantation of N{sup +} Ions

Accumulation of nitrogen in nanosized surface layers of 03Kh17N12M2 stainless steel has been detected upon N{sup +} ion implantation up to 14 at % together with metal nitrides, mainly of chromium nitride CrN and interstitial solid solution. It has been demonstrated that N{sup +} ion implantation accompanied by preliminary irradiation by Ar{sup +} and O{sup +} ions decreases maximum nitrogen concentration by at least two times. It is assumed that this is stipulated by segregation to surface layers of iron atoms upon irradiation by Ar{sup +} ions as well as formation of chromium oxide Cr{sub 2}O{sub 3} and chromium hydroxide CrOOH upon irradiation by O{sup +} ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dose Dependence of Nanocrystal Formation in Helium-Implanted Silicon Layers

The possibility of nanocrystal formation in silicon layers subjected to plasma-immersion helium-ion implantation at an energy of 5 keV has been proved for the first time. The effect of the implantation dose on the microstructure of the layers has been studied by X-ray reflectometry, transmission electron microscopy and Raman scattering. It has been established that the formation of silicon nanocrystals with dimensions of 10–20 nm is accompanied by a pronounced dependence on the ion flux and occurs at a dose of 5 × 10{sup 17} cm{sup –2} with subsequent annealing at 700–800°C. The excessive dose has been shown to cause the destruction of the upper protective sublayer and the degradation of the optical properties of nanocrystals.

77 NANOSCIENCE AND NANOTECHNOLOGY↗