Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Accelerating functional verification of an integrated circuit

Illustrative embodiments include a method, system, and computer program product for accelerating functional verification in simulation testing of an integrated circuit (IC). Using a processor and a memory, a serial operation is replaced with a direct register access operation, wherein the serial operation is configured to perform bit shifting operation using a register in a simulation of the IC. The serial operation is blocked from manipulating the register in the simulation of the IC. Using the register in the simulation of the IC, the direct register access operation is performed in place of the serial operation.

42 ENGINEERING↗

Closeout of CRADA JSA 2012S004: Chapter 5, Integrated Control System, of the document of the ESS Conceptual Design Report, publicly available at https://europeanspallationsource.se/accelerator-documents

The integrated control system (ICS) is responsible for the whole ESS machine and facility: accelerator, target, neutron scattering instruments and conventional facilities. This unified approach keeps the costs of development, maintenance and support relatively low. ESS has selected a standardised, field-proven controls framework, the Experimental Physics and Industrial Control System (EPICS), which was originally developed jointly by Argonne and Los Alamos National Laboratories. Complementing this selection are best practices and experience from similar facilities regarding platform standardisation, control system development and device integration and commissioning. The components of ICS include the control system core, the control boxes, the BLED database management system, and the human machine interface. The control system core is a set of systems and tools that make it possible for the control system to provide required data, information and services to engineers, operators, physicists and the facility itself. The core components are the timing system that makes possible clock synchronisation across the facility, the machine protection system (MPS) and the personnel protection system (PPS) that prevent damage to the machine and personnel, and a set of control system services. Control boxes are servers that control a collection of equipment (for example a radio frequency cavity). The integrated control system will include many control boxes that can be assigned to one supplier, such as an internal team, a collaborating institute or a commercial vendor. This approach facilitates a clear division of responsibilities and makes integration much easier. A control box is composed of a standardised hardware platform, components, development tools and services. On the top level, it interfaces with the core control system components (timing, MPS, PPS) and with the human-machine interface. At the bottom, it interfaces with the equipment and parts of the facility through a set of analog and digital signals, real-time control loops and other communication buses. The ICS central data management system is named BLED (beam line element databases). BLED is a set of databases, tools and services that is used to store, manage and access data. It holds vital control system configuration and physics-related (lattice) information about the accelerator, target and instruments. It facilitates control system configuration by bringing together direct input-output controller (IOC) con guration and real-time data from proton and neutron beam line models. BLED also simplifies development and speeds up the code-test-debug cycle. The set of tools that access BLED will be tailored to the needs of different categories of users, such as ESS staff physicists, engineers, and operators; external partner laboratories; and visiting experimental instrument users. The human-machine interface is vital to providing a high-quality experience to ICS users. It encompasses a wide array of devices and software tools, from control room screens to engineer terminal windows; from beam physics data tools to post-mortem data analysis tools. It serves users with a wide range of skills from widely varied backgrounds. The Controls Group is developing a set of user profiles to accommodate this diverse range of use-cases and users.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Integrated circuit physically unclonable function

An integrated circuit (IC) based physically unclonable function (PUF) that comprises a common source amplifier for generating PUF output voltages, a unity gain, negative feedback operational amplifier for generating bias voltages, a voltage regulator and a bit exclusion circuit that excludes unstable PUF bits. Compensation circuitry built into the IC-PUF provides a high power supply rejection ratio and enables highly reliable operation of the IC-PUF across varying input voltages and operating temperatures. The IC-PUF generates a uniformly random output bit stream by taking advantage of process variations that are inherent to the fabrication of (metal-oxide semiconductor) MOS transistors.

42 ENGINEERING↗

Automated Reconstruction of Control Logic for Programmable Logic Controller Forensics

This paper presents Similo, an automated scalable framework for control logic forensics in industrial control systems. Similo is designed to investigate denial of engineering operations (DEO) attacks, recently demonstrated to hide malicious control logic in a programmable logic controller (PLC) at field sites from an engineering software (at control center). The network traffic (if captured) contains substantial evidence to investigate DEO attacks including manipulation of control logic. Laddis, a state-of-the-art forensic approach for DEO attacks, is a binary-logic decompiler for the Allen-Bradley’s RSLogix engineering software and MicroLogix 1400 PLC. It is developed with extensive manual reverse engineering effort of the underlying proprietary network protocol and the binary control logic. Unfortunately, Laddis is not scalable and requires similar efforts to extend on other engineering software/PLCs. The proposed solution, Similo, is based on the observation that engineering software of different vendors are equipped with decompilers. Similo is a virtual-PLC framework that integrates the decompilers with their respective (previously-captured) ICS network traffic of control logic. It recovers the binary logic into a high-level source code (of the programming languages defined by IEC 61131-3 standard) automatically. Similo can work with both proprietary/open protocols without requiring protocol specifications and the binary formats of control logic. Thus, it is scalable to different ICS vendors. We evaluate Similo on three PLCs of two ICS vendors, i.e. MicroLogix 1400, MicroLogix 1100, and Modicon M221. These PLCs support proprietary protocols and the control logics written in two programming languages: Ladder Logic and Instruction List. The evaluation results show that Similo can accurately reconstruct a control logic from an ICS network traffic and can be used to investigate the DEO attacks effectively.

Ali qasim, Syed↗

Clarification of Institutional Controls at the Rocky Flats Site Central Operable Unit and Implementation of the Soil Disturbance Review Plan - 13053

Cleanup and closure of DOE's Rocky Flats Site in Colorado, which was placed on the CERCLA National Priority List in 1989, was accomplished under CERCLA, RCRA, and the Colorado Hazardous Waste Act (CHWA). The physical cleanup work was completed in late 2005 and all buildings and other structures that composed the Rocky Flats industrial complex were removed from the surface, but remnants remain in the subsurface. Other remaining features include two landfills closed in place with covers, four groundwater treatment systems, and surface water and groundwater monitoring systems. Under the 2006 Corrective Action Decision/Record of Decision for Rocky Flats Plant (US DOE) Peripheral Operable Unit and the Central Operable Unit (CAD/ROD), the response actions selected for the Central Operable Unit (OU) are institutional controls (ICs), physical controls, and continued monitoring and maintenance. The objectives of these ICs were to prevent unacceptable exposure to remaining subsurface contamination and to prevent contaminants from mobilizing to surface water and to prevent interfering with the proper functioning of the engineered components of the remedy. An amendment in 2011 of the 2006 CAD/ROD clarified the ICs to prevent misinterpretation that would prohibit work to manage and maintain the Central OU property. The 2011 amendment incorporated a protocol for a Soil Disturbance Review Plan for work subject to ICs that requires approval from the State and public notification by DOE prior to conducting approved soil-disturbing work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Designing a Site Closure Strategy for Uranium in Groundwater and Surface Water - 19534

A site closure strategy was designed and mapped for residual uranium present in groundwater and surface water at the US DOE Office of Legacy Management (LM) Monticello Mill Tailings Site (MMTS) Operable Unit (OU) III, which is regulated under CERCLA. The MMTS is a former mill site that was used to process uranium and vanadium ore in southeastern Utah until 1960. OU III includes surface water in Montezuma Creek and groundwater present in a shallow alluvial aquifer along the creek valley for several kilometers downgradient of the former mill site. The current remedy consists of an operating pump-and-treat system, monitored natural attenuation (MNA), and institutional controls (ICs). Performance evaluations indicate that a prolonged restoration period is likely, as well as an asymptotic trend in uranium concentrations that still exceed the remediation goal. Multiple strategies and scenarios were evaluated before selecting a preferred site closure strategy. Recommendations were developed to support advancing the site towards closure over the next few years and guide the process of regulatory interactions and decision making at the MMTS OU III. Site closure is an important milestone that reflects successful remedial progress at LM sites. Post-closure site management would be maintained to ensure conditions are protective of human health and the environment. The site closure strategy was considered in the context of site remedial progress. The primary sources of groundwater contamination have been removed, including mill tailings and contaminated soils, sediment, and debris. Five-year reviews have regularly concluded that the remedy is protective of human health and environment and that ICs are effective in preventing exposure to contaminated groundwater. The affected aquifer is low-yielding and has no history of domestic use. In 2004, the final remedy selected in the Record of Decision (ROD) was MNA with ICs. However, a pump-and-treat system was installed and continues to operate as a contingency remedy in the area with the highest residual uranium concentrations. The need for a contingency pump-and-treat system was triggered by a departure of the long-term monitoring data from model projections that were used as the basis for remedy performance metrics specified in the ROD. In 2015, the pump-and-treat system was expanded. Average uranium concentrations have declined locally over time. However, monitoring data and column studies indicate that the system effectiveness will eventually become ineffective in reducing uranium concentrations, likely due to the reequilibration of uranium present in the solid matrix in various states (i.e., sorbed, precipitated). Currently, there are no agreed-upon metrics for discontinuing the contingency pump-and-treat system. Three closure strategies effectively applied at other CERCLA sites were considered at MMTS OU III: (1) restoring natural attenuation conditions and conducting MNA; (2) applying alternate concentration limits (ACLs); and (3) waiving a remedial goal based on technical impracticability (TI). Each closure strategy was evaluated in the following manner: (1) identifying the criteria and requirements associated with current regulations, policy, and guidance, (2) assessing the ability to meet those criteria based on the current site knowledge and the conceptual site model, and (3) identifying data gaps that need to be filled to further assess the closure strategy. Following this evaluation, a preferred closure strategy was selected: to transition to a remedy based on MNA and maintenance of ICs, without active remediation. Several scenarios for transitioning to the preferred closure strategy were identified. Each scenario consisted of 'if/then logic' associated with a larger decision diagram. The decision diagram considered the current conceptual site model (CSM) and potential outcomes of studies that will be conducted to fill data gaps, as well as the performance of the existing treatment system and long-term monitoring data. Two scenarios for transitioning to the preferred closure strategy were highlighted for future planning and were described in detail. For both scenarios, the preferred closure strategy includes demonstrating criteria for MNA acceptance, pump-and-treat termination, long-term monitoring, and eventual site delisting. Recommended actions over the next few years were also developed, including updating the CSM, conducting numerical modeling to predict remedial performance and time frames, conducting geochemical analyses to assess uranium fate and transport, and summarizing the lines of evidence and basis for MNA. This detailed example of the development of a site-specific closure strategy provides the thought process and decision logic used to assess uncertainty using an if/then framework; identify common elements and recommended actions to advance the site towards closure; and navigate the inherent uncertainty in the timing of future events, outcome of regulatory discussions, and remedial progress over time that is common to many complex US DOE facilities. In addition, the national regulations, policy, guidance, and state of practice regarding commonly used site closure strategies was summarized for consideration, including MNA, ACLs, and TI. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Challenges of Maintaining Institutional Controls: Maintenance of an Alternate Water Supply- A Case Study - 19583

The US Department of Energy (DOE) cofunded an alternate water-supply system (AWSS) with the Indian Health Service that was installed in the vicinity of the former uranium mill site near Riverton, Wyoming, as one of the institutional controls (ICs) at the site. The AWSS was constructed in 1998 to supply drinking water to residents within the IC boundary in lieu of drinking untreated groundwater that could potentially be impacted by the contaminated shallow aquifer. The AWSS derives water from three source wells that pump groundwater from the sandstones of the Wind River Formation to a 3.8 x 106 liter (1,000,000 gallon) storage tank. Water from the storage tank is distributed throughout the AWSS service area by approximately 18 kilometers (11 miles) of PVC pipeline. The AWSS currently serves 103 residential customers and 1 commercial customer. DOE and the Northern Arapaho tribe (owner of the AWSS) have partnered over the years to address numerous challenges with the AWSS that included engineering assessments, scientific investigations, sampling support, a hydrant flushing program, and funding. Challenges with the AWSS have included the following: (1) Transmission pipe installed during initial construction did not have a pressure rating high enough to account for system pressure surges. (2) AWSS appurtenances were initially installed without accounting for the effects of corrosive soils on metal components. (3) Natural radium from the Wind River Formation groundwater builds up in the AWSS transmission pipes to levels above the primary drinking water standard because of the lack of a flushing program, dead-end lines, and low system demand. A 2-year study showed that a unidirectional hydrant-flushing program will control the radium buildup. (4) Aging system components including hydrants, valves, and pumps are nearing their effective lifespan and are in need of replacement. (5) With the addition of large commercial customers, demand on the system has increased since the initial installation of the system, and future growth in the area will continue to increase demand. (6) Additional connections and integration of the AWSS with an areawide water system in the near future will require changes to the current flushing plan and add additional complexity regarding areas of responsibility. (7) A well-organized financial and administrative infrastructure is not in place, and additional revenue is needed to operate, maintain, and improve the AWSS. To be a viable IC, the AWSS will require management, maintenance, and upgrades to provide safe drinking water until groundwater meets drinking water standards. Responsibilities and funding for maintaining the AWSS as a viable IC are the focus of current discussions, and decisions regarding responsibilities and funding will be formalized in future cooperative agreements and memoranda of understanding with the owners. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resilience Evaluation and Enhancement for Island City Integrated Energy Systems

Extreme natural hazards, such as hurricanes or earthquakes, have a high probability of threatening energy supply security and causing high-order contingencies to island city-integrated energy systems (IC-IESs). To better evaluate and enhance resilience, a novel approach is proposed in this work for IC-IESs. The resilience of an IC-IES is analyzed from both the system level and the component level. At the system level, the impacts of extreme natural disasters are quantified. At the component level, the importance of individual components is analyzed through pre-failure and post-failure indices. The pre-failure index identifies the system’s weak links before an energy interruption, and the post-failure index determines the optimal repair strategy to restore the service. The proposed indices are solved by the impact increment method (IIM), which significantly improves computational efficiency without much affecting result accuracy. Numerical simulation studies are conducted on the modified Barry Island IES and IES E123-G48-H32 test systems. Furthermore, the results validate the effectiveness of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Are System Baselines within OT Environments Feasible?

Critical infrastructure stakeholders need to baseline their systems to understand expected protocol communications.Baseline behaviors may vary based on operational context.Expected operations during a maintenance window, for example, may be different from normal operations.Furthermore, constructing system baselines for Industrial Control Systems (ICS) is difficult and time-consuming.ICS processes generate artifacts expressed across heterogeneous data sources such as network and device logs. There needs to be a corpus of data in order to develop and compare methods that evaluate the feasibility, performance, and generality of approaches to construct baselines for ICS events. Standalone repositories of network packet captures are insufficient to develop methods to classify or recognize operational events expressed across multiple data sources. Moreover, static data corpora do not enable researchers to compare the impact of changing the underlying system for which a baseline is being constructed and this limits the ability to evaluate the performance of system baselines given system changes (e.g. patches, configuration, maintenance events). In order to address these limitations within the community, this talk intends to promote discussion about the state of the practice of constructing baselines. In this manner, we can continue to understand requirements within industry that are not being met by current approaches to baseline construction. This talk builds on two previous talks on the topic of system baselines for OT environments. First, Weaver co-presented at the RSA Conference ICS Sandbox with Dan Gunter. The talk confirmed the need within industry to construct baselines across multiple types of data sources relative to the semantics of specific business processes. Second, Weaver presented at IEEE Security and Privacy Workshop on Language-Theoretic Security.

02 PETROLEUM↗

Ternary Organic Solar Cells with Efficiency >16.5% Based on Two Compatible Nonfullerene Acceptors

Abstract A ternary structure has been demonstrated as being an effective strategy to realize high power conversion efficiency (PCE) in organic solar cells (OSCs); however, general materials selection rules still remain incompletely understood. In this work, two nonfullerene small‐molecule acceptors 3TP3T‐4F and 3TP3T‐IC are synthesized and incorporated as a third component in PM6:Y6 binary blends. The photovoltaic behaviors in the resultant ternary OSCs differ significantly, despite the comparable energy levels. It is found that incorporation of 15% 3TP3T‐4F into the PM6:Y6 blend results in facilitating exciton dissociation, increasing charge transport, and reducing trap‐assisted recombination. All these features are responsible for the enlarged PCE of 16.7% (certified as 16.2%) in the PM6:Y6:3TP3T‐4F ternary OSCs, higher than that (15.6%) in the 3TP3T‐IC containing ternary devices. The performance differences are mainly ascribed to the compatibility between the third component and the host materials. The 3TP3T‐4F guest acceptor exhibits an excellent compatibility with Y6, tending to form well‐mixed phases in the ternary blend without disrupting the favored bicontinuous transport networks, whereas 3TP3T‐IC displays a morphological incompatibility with Y6. This work highlights the importance of considering the compatibility for materials selection toward high‐efficiency ternary organic OSCs.

Song, Jiali↗

Isolation of the New Antiplasmodial Butanolide, Malleastrumolide A, from Malleastrum sp. (Meliaceae) from Madagascar

An extract of Malleastrum sp. (Meliaceae) collected in Madagascar by the Madagascar International Cooperative Biodiversity Group was found to have antimalarial activity, with an IC 50 value between 2.5 and 5 μg ml −1 . After purification by liquid‐liquid partition, chromatography on a Diaion open column, C 18 SPE and C 18 reversed phase HPLC , the new butanolide, malleastrumolide A, was isolated. The structure of malleastrumolide A was determined by mass spectrometry, NMR , and ECD . The double bond position was determined by cross‐metathesis and mass spectrometry. The compound has antiproliferative activity against the A2780 ovarian cancer cell line with an IC 50 value of 17.4 μ m and antiplasmodial activity against the drug‐resistant Dd2 strain of Plasmodium falciparum with an IC 50 value of 2.74 μ m .

Du, Yongle↗

Overshadow PLC to Detect Remote Control-Logic Injection Attacks

Programmable logic controllers (PLCs) in industrial control systems (ICS) are vulnerable to remote control logic injection attacks. Attackers target the control logic of a PLC to manipulate the behavior of a physical process such as nuclear plants, power grids, and gas pipelines. Control logic attacks have been studied extensively in the literature, including hiding the transfer of a control logic over the network from both packet header-based signatures, and deep packet inspection. For instance, these attacks transfer a control logic code as data, into small fragments (one-byte per packet), that are further padded with noise data. To detect control logic in ICS network traffic, this paper presents Shade, a novel shadow memory technique that observes the network traffic to maintain a local copy of the current state of a PLC memory. To analyze the memory contents, Shade employs a classification algorithm with 42 unique features categorized into five types at different semantic levels of a control logic code, such as number of rungs, number of consecutive decompiled instructions, and n-grams. We then evaluate Shade against control logic injection attacks on two PLCs, Modicon M221 and MicroLogix 1400 from two ICS vendors, Schneider electric and Allen-Bradley, respectively. The evaluation results show that Shade can detect an attack instance (i.e., identifying at least one attack packet during the transfer of a malicious control logic) accurately without any false alarms.

Yoo, Hyunguk↗

Structure-activity relationships of novel dithiocarbamates containing α,β-unsaturated ketone fragment as potent anticancer agents

Based on the structure of novel lead compound 8 discovered by our group, systematic structural modification was carried out. A series of compound 8’s derivatives were synthesized and evaluated for their activities against human non-small cell lung cancer cell line H460. Among them, twelve compounds showed significant proliferation inhibition activities with IC{sub 50} values <1 μM and compound 12r was the most potent one. Further study on compound 12r revealed that it has significant inhibitory effect on the growth of eight kinds of cancer cell lines with IC{sub 50} values <1 μM. Especially for cell lines A375 and HCT116, the IC{sub 50} values of 12r achieved 63 nM and 66 nM, respectively. Meanwhile, our research results also revealed the following structure-activity relationships: (a) different substitutions on the benzene ring or heteroaromatic rings greatly effect on the activity; (b) the presence of α,β-unsaturated ketone fragment is favorable for the activity; (c) the receptor cavity binding with amine moiety might be a relatively small hydrophobic cavity. These results will be valuable for the further development of this novel kind of dithiocarbamates.

60 APPLIED LIFE SCIENCES↗

Synthesis and biological evaluation of novel disulfides incorporating 1,3,4-thiadiazole scaffold as promising antitumor agents

In the present study, fourteen 2,5-disubstituted 1,3,4-thiadiazole derivatives containing disulfide group were prepared. The resulting compounds 7a–7n were identified by IR, NMR, MS, and elemental analysis. Their antiproliferative properties in vitro were studied employing standard CCK-8 assay against SMMC-7721, MCF-7, and A549 lines. Bioassay indicated that some compounds showed stronger antitumor effects than reference drugs PX-12 and 5-fluorouracil. Among these screened compounds, compound 7h showed excellent biological activities in inhibiting SMMC-7721 cell proliferation with IC{sub 50} at 1.93 ± 0.08 μM. Compounds 7k and 7i manifested highly effective growth inhibitory activity versus MCF-7 cells, with IC{sub 50} at 3.04 ± 0.09 and 3.54 ± 0.17 μM, respectively. For A549 cells, compound 7m was found to have the highest antitumor potency with IC{sub 50} at 3.67 ± 0.13 μM.

60 APPLIED LIFE SCIENCES↗

Synthesis and antitumor evaluation of novel fused heterocyclic 1,2,4-triazolo[3,4-b]-1,3,4-thiadiazole derivatives

In this study, twenty three 3,6-disubstituted 1,2,4-triazolo[3,4-b]-1,3,4-thiadiazole derivatives were synthesized and their antiproliferative activities in vitro were studied against SMMC-7721, HeLa, A549, and L929 by the CCK-8 assay. The bioassay results demonstrated that all tested compounds 8(a–w) exhibited antiproliferation with different degrees, and some compounds showed better effects than reference drug 5-fluorouracil. Among these screened compounds, compounds 8a, 8d, and 8l displayed significant antitumor activities in inhibiting SMMC-7721cell proliferation with IC{sub 50} values of 1.64, 1.74, and 1.61 µM, respectively. Compounds 8d and 8l were manifested highly effective biological activity versus HeLa cells with IC{sub 50} values of 2.23 and 2.84 µM, respectively. Compound 8l was found to have the highest antitumor potency against A549 cells with IC{sub 50} value of 2.67 µM. Furthermore, all compounds exhibited weaker cytotoxic effects than 5-fluorouracil on normal cell lines L929.

60 APPLIED LIFE SCIENCES↗

Ionic conductivity optimization of composite polymer electrolytes through filler particle chemical modification

The addition of filler particles to polymer electrolytes is known to increment their ionic conductivity (IC). A detailed understanding of how the interactions between the constituent materials are responsible for the enhancement remains to be developed. A significant contribution is ascribed to an increment of the polymer amorphous fraction, induced by the fillers, resulting in the formation of higher ionic conductivity channels in the polymer matrix. However, the dependence of IC on the particle weight load and its composition on the polymer morphology is not fully understood. This work investigates Li-ion transport in composite polymer electrolytes (CPE) comprising Bi-doped LLZO particles embedded in PEO:LiTFSI matrixes. We find that the IC optimizes for very low particle weight loads (5-10%) and that both its magnitude and the load are required, strongly dependent on the garnet particle composition. Based on structural characterization results and electrochemical impedance spectroscopy, a mechanism is proposed to explain these findings. It is suggested that the Li-molar content in the garnet particle controls its interactions with the polymer matrix, resulting at the optimum loads reported, in the formation of high ionic conductivity channels. We propose that filler particle chemical manipulation of the polymer morphology is a promising avenue for the further development of composite polymer electrolytes.

bismuth↗

Everolimus in combination with Imatinib overcomes resistance in Chronic myeloid leukaemia

Although Imatinib and other tyrosine kinase inhibitors (TKIs) have excellent results, the appearance of resistance is a problem in chronic myeloid leukaemia (CML). PI3K/AKT/mTOR pathway is activated by BCR-ABL playing a crucial rule in CML. This study aimed to evaluate the therapeutic potential of Everolimus, in CML models sensitive and resistant to Imatinib. We used one CML cell line sensitive to Imatinib (K562) and two resistant (K562-RC and K56-RD). Cell lines were treated with Everolimus alone and in combination with Imatinib. Cell viability was analysed by resazurin assay. Cell death and cell cycle were analysed by flow cytometry. Additionally, we also studied peripheral blood samples obtained from 52 patients under TKI treatment. Everolimus reduced cell line viability in sensitive (IC{sub 50} = 20 µM) and resistant models (K562-RC, IC{sub 50} = 25 µM; K562-RD, IC{sub 50} = 30 µM). This drug induced cell death by apoptosis and cell cycle arrest in G{sub 0}/G{sub 1} phase. Everolimus also reduced cell viability by increasing apoptosis of haematopoietic stem cells (CD34{sup +} cells) with low cytotoxicity to lymphocytes. Everolimus at 25 µM increased apoptotic cells 18.7% in CD34{sup +} cells and only 8% in lymphocytes. The response to Everolimus was influenced by TKI treatment, with a better response in samples from patients under 2nd and 3rd generation TKI and with less toxicity to lymphocytes. Our results reveal that Everolimus induce cell death in CML cells sensitive and resistant to Imatinib, with low cytotoxicity to normal cells, suggesting that Everolimus could be an alternative targeted therapeutic approach in CML patients, even in cases of Imatinib resistance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical oscillator strengths, transition probabilities, and radiative lifetimes of levels in Pb V

Theoretical values of oscillator strengths and transition probabilities for 306 spectral lines arising from the 5d{sup 9}ns(n=7,8,9),5d{sup 9}np(n=6,7),5d{sup 9}6d, and 5d{sup 9} 5f configurations, and radiative lifetimes of 9 levels, of Pb V have been obtained. These values were obtained in intermediate coupling (IC) and using ab initio relativistic Hartree–Fock calculations including core-polarization effects. We use for the IC calculations the standard method of least squares fitting of experimental energy levels by means of computer codes from Cowan. We included in these calculations the 5d{sup 8}6s6p and 5d{sup 8}6s{sup 2} configurations. These calculations have facilitated the identification of the 214.25, 216.79, and 227.66 nm spectral lines of Pb V. In the absence of experimental results of oscillator strengths and transition probabilities, we could not make a direct comparison with our results. However, the Stark broadening parameters calculated from these values are in excellent agreement with experimental widening found in the literature. -- Highlights: •Theoretical values of transition probabilities of Pb V have been obtained. •We use for the IC calculations the standard method of least square. •The parameters calculated from these values are in agreement with the experimental values.

74 ATOMIC AND MOLECULAR PHYSICS↗