Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Quantitative probing of the fast particle motion during the solidification of battery electrodes

Synchrotron x-ray tomography represents one of the most powerful imaging techniques that can visualize the three-dimensional microstructural complexity with a high spatial resolution. To date, however, the temporal resolution of this technique has been handicapped by the intrinsic limitations in the data acquisition speed and the lack of a suitable data processing method. The present study aims to fundamentally resolve this challenge by implementing a data analysis method that is based on differentiating discrete tomography reconstruction from a continuous scan reconstruction. With this methodological development, we capture and quantify the particle motion during the solidification of battery electrodes and reveal the statistics of the dynamically evolving motion in the drying process, which has been challenging to resolve. We discover that the particle motion exhibits a strong dependence on its geometric location within a drying electrode. Our results also imply that the final electrode quality can be controlled by balancing the solvent evaporation rate and the particle mobility in the region close to the drying surface.

25 ENERGY STORAGE↗

Creation of large temperature anisotropies in a laboratory plasma

Ion temperature anisotropy in an expanding magnetized plasma is investigated using laser induced fluorescence. Parallel and perpendicular ion velocity distribution functions (IVDFs) were measured simultaneously with high spatial resolution in the expanding plasma. Large ion temperature anisotropies (T ⊥i /T ∥i ~ 10) are observed in a conical region at the periphery of the expanding plasma plume. A simple 2D Boris stepper model that incorporates the measured electric field structure is able to reproduce the gross features of the measured perpendicular IVDFs. Here, a Nyquist stability analysis of the measured IVDFs suggests that multiple instabilities with k ⊥ρi ~ 1 and k ||ρi ~ 0.2 are likely to be excited in these plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Explaining an unusual electromigration behavior—A comprehensive experimental and theoretical analysis using finite element method

In metallic interconnects, it is generally assumed that electromigration (EM) failure location is independent of the applied electrical current and always occurs at the highest-current-density area. Our experiments show otherwise. We designed an Al interconnect that alters its failure location by only varying the applied current density. The failure occurs near the high for a current above 2 × 10 7 A/cm 2 , but at a location with 59% of the maximum for lower current densities. Thermoreflectance thermal imaging is employed to gather time-dependent high-resolution spatial temperature distributions of the Al interconnect during EM. More importantly, we propose a computationally inexpensive 2D finite element method that tracks EM evolution in time and matches well with the observations from different experimental conditions. A detailed analysis covering the major driving forces of EM is carried out to understand the complex physics behind EM. The atomic depletion rate contributed by each force is quantitatively studied. By examining the results from every tested experimental condition, the model reveals that the temperature gradient is the key reason causing atomic depletion near the failure location. Graphical illustrations and qualitative analysis are provided to intuitively show the key findings of our work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic imaging and statistical analysis of the metamagnetic phase transition of FeRh with electron spins in diamond

Magnetic imaging based on nitrogen-vacancy (NV) centers in diamond has emerged as a powerful tool for probing magnetic phenomena in fields ranging from biology to physics. A key strength of NV sensing is its local-probe nature, enabling high-resolution spatial images of magnetic stray fields emanating from a sample. However, this local character can also form a drawback for analyzing the global properties of a system, such as a phase transition temperature. Here, we address this challenge by using statistical analyses of magnetic-field maps to characterize the first-order temperature-driven metamagnetic phase transition from the antiferromagnetic to the ferromagnetic state in FeRh. After imaging the phase transition and identifying the regimes of nucleation, growth, and coalescence of ferromagnetic domains, we statistically characterize the spatial magnetic-field maps to extract the transition temperature and thermal hysteresis width. By analyzing the spatial correlations of the maps in relation to the magnetocrystalline anisotropy and external magnetic field, we detect a reorientation of domain walls across the phase transition. The employed statistical approach can be extended to the study of other magnetic phenomena with NV magnetometry or other sensing techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AFM-IR and s-SNOM-IR measurements of chemically addressable monolayers on Au nanoparticles

The performance of catalysts depends on their nanoscale properties, and local variations in structure and composition can have a dramatic impact on the catalytic reactivity. Therefore, probing the localized reactivity of catalytic surfaces using high spatial resolution vibrational spectroscopy, such as infrared (IR) nanospectroscopy and tip-enhanced Raman spectroscopy, is essential for mapping their reactivity pattern. Two fundamentally different scanning probe IR nanospectroscopy techniques, namely, scattering-type scanning near-field optical microscopy (sSNOM) and atomic force microscopy-infrared spectroscopy (AFM-IR), provide the capabilities for mapping the reactivity pattern of catalytic surfaces with a spatial resolution of ~20 nm. Herein, we compare these two techniques with regard to their applicability for probing the vibrational signature of reactive molecules on catalytic nanoparticles. For this purpose, we use chemically addressable self-assembled molecules on Au nanoparticles as model systems. We identified significant spectral differences depending on the measurement technique, which originate from the fundamentally different working principles of the applied methods. While AFM-IR spectra provided information from all the molecules that were positioned underneath the tip, the s-SNOM spectra were more orientation-sensitive. Due to its field-enhancement factor, the s-SNOM spectra showed higher vibrational signals for dipoles that were perpendicularly oriented to the surface. The s-SNOM sensitivity to the molecular orientation influenced the amplitude, position, and signal-to-noise ratio of the collected spectra. Ensemble-based IR measurements verified that differences in the localized IR spectra stem from the enhanced sensitivity of s-SNOM measurements to the adsorption geometry of the probed molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membrane potential sensing: Material design and method development for single particle optical electrophysiology

We review the development of “single” nanoparticle-based inorganic and organic voltage sensors, which can eventually become a viable tool for “non-genetic optogenetics.” The voltage sensing is accomplished with optical imaging at the fast temporal response and high spatial resolutions in a large field of view. Inorganic voltage nanosensors utilize the Quantum Confined Stark Effect (QCSE) to sense local electric fields. Engineered nanoparticles achieve substantial single-particle voltage sensitivity (~2% Δλ spectral Stark shift up to ~30% ΔF/F per 160 mV) at room temperature due to enhanced charge separation. A dedicated home-built fluorescence microscope records spectrally resolved images to measure the QCSE induced spectral shift at the single-particle level. Biomaterial based surface ligands are designed and developed based on theoretical simulations. The hybrid nanobiomaterials satisfy anisotropic facet-selective coating, enabling effective compartmentalization beyond non-specific staining. Self-spiking- and patched-HEK293 cells and cortical neurons, when stained with hybrid nanobiomaterials, show clear photoluminescence intensity changes in response to membrane potential (MP) changes. Organic voltage nanosensors based on polystyrene beads and nanodisk technology utilize Fluorescence (Förster) Resonance Energy Transfer (FRET) to sense local electric fields. Voltage sensing FRET pairs achieve voltage sensitivity up to ~35% ΔF/F per 120 mV in cultures. Non-invasive MP recording from individual targeted sites (synapses and spines) with nanodisks has been realized. However, both of these QCSE- and FRET-based voltage nanosensors yet need to reach the milestone of recording individual action potentials from individual targeted sites.

59 BASIC BIOLOGICAL SCIENCES↗

Planar laser induced fluorescence mapping of a carbon laser produced plasma

We present measurements of ion velocity distribution profiles obtained by laser induced fluorescence (LIF) on an explosive laser produced plasma. The spatiotemporal evolution of the resulting carbon ion velocity distribution was mapped by scanning through the Doppler-shifted absorption wavelengths using a tunable, diode-pumped laser. The acquisition of these data was facilitated by the high repetition rate capability of the ablation laser (1 Hz), which allowed for the accumulation of thousands of laser shots in short experimental times. By varying the intensity of the LIF beam, we were able to explore the effects of fluorescence power against the laser irradiance in the context of evaluating the saturation vs the non-saturation regime. The small size of the LIF beam led to high spatial resolution of the measurement compared to other ion velocity distribution measurement techniques, while the fast-gate operation mode of the camera detector enabled the measurement of the relevant electron transitions.

Instruments & Instrumentation↗

Element-specific first order reversal curves measured by magnetic transmission x-ray microscopy

The first-order reversal curve (FORC) method is a macroscopic measurement technique that can be used to extract quantitative and microscopic properties of hysteretic systems. Using magnetic transmission x-ray microscopy (MTXM), local element-specific FORC measurements are performed on a 20 nm thick film of CoTb. The FORCs measured with microscopy reveal a step-by-step domain evolution under the magnetic field cycling protocol and provide a direct visualization of the mechanistic interpretation of FORC diagrams. They are compared with magnetometry FORCs and show good quantitative agreement. Furthermore, the high spatial resolution and element-specific sensitivity of MTXM provide new capabilities to measure FORCs in small regions or specific phases within multicomponent systems, including buried layers in heterostructures. The ability to perform FORCs on very small features is demonstrated with the MTXM-FORC measurement of a rectangular microstructure with vortex-like Landau structures. This work demonstrates the confluence of two uniquely powerful techniques to achieve quantitative insight into nanoscale magnetic behavior.

36 MATERIALS SCIENCE↗

Synchrotron radiography of Richtmyer–Meshkov instability driven by exploding wire arrays

We present a new technique for the investigation of shock-driven hydrodynamic phenomena in gases, liquids, and solids in arbitrary geometries. The technique consists of a pulsed power-driven resistive wire array explosion in combination with multi-MHz synchrotron radiography. Compared to commonly used techniques, it offers multiple advantages: (1) the shockwave geometry can be shaped to the requirements of the experiment, (2) the pressure (P > 300 MPa) generated by the exploding wires enables the use of liquid and solid hydrodynamic targets with well-characterized initial conditions (ICs), (3) the multi-MHz radiography enables data acquisition to occur within a single experiment, eliminating uncertainties regarding repeatability of the ICs and subsequent dynamics, and (4) the radiographic measurements enable estimation of compression ratios from the x-ray attenuation. In addition, the use of a synchrotron x-ray source allows the hydrodynamic samples to be volumetrically characterized at a high spatial resolution with synchrotron-based microtomography. This experimental technique is demonstrated by performing a planar Richtmyer–Meshkov instability (RMI) experiment on an aerogel–water interface characterized by Atwood number A0∼−0.8 and Mach number M∼1.5. The qualitative and quantitative features of the experiment are discussed, including the energy deposition into the exploding wires, shockwave generation, compression of the interface, startup phase of the instability, and asymptotic growth consistent with Richtmyer's impulsive theory. Additional effects unique to liquids and solids—such as cavitation bubbles caused by rarefaction flows or initial jetting due to small perturbations—are observed. It is also demonstrated that the technique is not shape dependent by driving a cylindrically convergent RMI experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A confocal laser-induced fluorescence diagnostic with an annular laser beam

Here, in this work, we report an annular beam confocal laser-induced fluorescence (LIF) configuration, which allows for high spatial resolution measurements of plasma properties in plasma setups and sources with limited optical access. The proposed LIF configuration utilizes the annular laser beam generated by a pair of diffractive axicons. The LIF signal is collected along the main optical axis within the ring region. It is shown experimentally that at a focal distance of 300 mm, a spatial resolution of ~5.3 mm can be achieved. Using geometric optics estimations, we showed that ~1 mm resolution at the same focal distance could potentially be achieved by modifying laser beam parameters. This approaches the localization accuracy of conventional LIF collection methods (with crossing laser beam injection and fluorescence collection optical paths). Measurements of the ion velocity distribution function in an argon plasma using both the confocal LIF with an annular laser beam and conventional LIF demonstrate a satisfactory agreement. The proposed LIF setup has potential applications for diagnostics in various plasma processing equipment and plasma sources, such as hollow cathodes, microplasmas, electric propulsion, etc.

47 OTHER INSTRUMENTATION↗

Imaging of dark line defect growth in high-power diode laser cavities using broadband near infrared light emission from the laser cavity

An in situ and nondestructive technique is developed to image the formation and evolution of dark line defects in the cavity of a high-power diode laser. Here, the technique uses broadband near infrared emission that originates in the laser's core layers and enables defects to be imaged with high spatial resolution through the substrate. In particular, it enables defect imaging through the substrate of shorter wavelength lasers, even when the substrate is opaque near the lasing wavelength. The evolution of dark line defects during aging is studied in several devices, with correlations established between the observed characteristics of defect growth and changes in device parameters such as optical power, operating wavelength, threshold current, and slope efficiency. Gradual degradation is found to be associated with dark line defects that slowly propagate from dark spots that are present in the device interior in its fresh (unaged) condition, rather than propagating from spots that are formed during aging, suggesting a strategy to screen fresh devices for expected reliability. This defect growth phenomenon is found to be particularly evident in the dark spots near the output facet.

47 OTHER INSTRUMENTATION↗

A platform to measure isentropes from proton-heated warm dense matter on short pulse laser facilities

We describe the development of an experimental platform that measures the release isentrope of materials heated isochorically to temperatures of a few electron volts, using short-pulse laser-produced protons to heat the sample and long-pulse laser-produced x rays to perform streaked x-ray radiography. The density profiles derived from the radiography data are integrated to generate pressure–density isentropes, independent of prior knowledge of the equation of state of the sample material. In order to understand the sensitivities of isentrope extraction from radiography data, we analyze synthetic radiographs generated by a radiation hydrodynamics code. Noise reduction and high spatial resolution are critical for isentrope reconstruction, as demonstrated by the analysis of a proof-of-principle shot day on the OMEGA-EP facility. In conclusion, the data demonstrate the feasibility of the platform for characterizing isentropes, and we discuss the necessary improvements to enhance precision in differentiating between equation-of-state models.

Equations of state↗

Structural characterization of neutron irradiated hexagonal boron-10 nitride-15 single crystals

The negatively charged boron vacancy ($V$$^{–}_{⁠B}$⁠) in hexagonal boron nitride (hBN) is a promising quantum defect that can be used to sense pressure, temperature, and magnetic field with high spatial resolution. hBN enriched with the boron-10 and nitrogen-15 isotopes, denoted h 10 B 15 N, has good contrast and coherence for quantum sensing because nitrogen-15 has nuclear spin (1/2), reducing hyperfine interactions. Boron vacancies can be generated by neutron irradiation, which causes the transmutation of the boron-10 isotope to lithium-7. In this study, the ancillary structural, compositional, and mechanical properties of h 10 B 15 N crystals that have been subjected to neutron irradiation fluences from 1.4 × 10 16 to 8.4 × 10 17 n/cm 2 were thoroughly characterized. Besides creating $V$$^{–}_{⁠B}$⁠, the process also induces other defects that generate strain in the crystal lattice. In turn, the mechanical properties of these crystals change drastically. Investigated here are the visual changes, lattice integrity, composition, crystal strain, and elastic constants (C 33 and C 66 ) to assess how these characteristics change as a function of neutron fluence.

36 MATERIALS SCIENCE↗

Density limits as disruption forecasters for spherical tokamaks

Fusion power output from spherical tokamaks would benefit from increased confined plasma density, but there exists a limit on the density before confinement is lost and the plasma current is disrupted. This density limit has long been characterized by a simple, global Greenwald limit proportional to the plasma current and inversely proportional to the cross sectional area of the plasma. It is shown that in the database of discharges from the National Spherical Tokamak Experiment (NSTX) and Mega Ampere Spherical Tokamak (MAST) spherical tokamaks, the likelihood of disruption does increase above the Greenwald limit, and especially in the plasma current rampdown phase. The physics of the density limit has been recently theoretically explored through local criteria. Several of these are tested using the disruption event characterization and forecasting (DECAF TM ) code for their potential effectiveness as disruption warning signals. For a limited set of NSTX discharges, a local island power balance criteria was found to be less reliable, presently, than the Greenwald limit. For this work, an empirical critical edge line density and a boundary turbulent transport limit were both tested for MAST-U, which has an electron density profile measurement with high spatial resolution in the outer part of the plasma. Both were found to have similar dependencies on key plasma parameters. In a limited set of MAST-U discharges that appear to disrupt due to rising density at values under the Greenwald limit, crossing of the boundary turbulent transport limit occurred close to the time of disruption. Finally, these limits were evaluated for their potential use in real-time, and it was found that with the necessary real-time inputs and with refinement through further testing, these limits could be implemented in a real-time disruption forecasting system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of predictive correlation between flux expulsion and grain growth for superconducting radio frequency cavities

Abstract A series of experiments were carried out in an effort to develop a simple method for predicting the magnetic flux expulsion behavior of high purity niobium used to fabricate superconducting radio frequency (SRF) cavities. Using conventional metallographic characterizations in conjunction with high spatial resolution electron backscattered diffraction-orientation imaging microscopy, we find that the flux expulsion behavior of 1.3 GHz single cell SRF Nb cavities is significantly associated with the grain growth of the Nb material during heat treatment. Most of the Nb grains rapidly grew during 900 °C heat treatment, and were likely full-recrystallized with 1000 °C HT. When compared to the magnetic flux expulsion ratio ( B sc / B nc ) at Δ T = 5 K, the flux expulsion efficiency of the cavities increases with the increase of grain size. Most interestingly, 900 °C HT shows a roughly linear trend that suggests that this criterion could be used to predict the appropriate heat treatment temperature for sufficient flux expulsion behavior in SRF-grade Nb. This result can be used to see if flux expulsion can be predicted by examining the materials coming from Nb vendors, prior to cavity fabrication.

43 PARTICLE ACCELERATORS↗

Augmented signal processing in Liquid Argon Time Projection Chambers with a deep neural network

The Liquid Argon Time Projection Chamber (LArTPC) is an advanced neutrino detector technology widely used in recent and upcoming accelerator neutrino experiments. It features a low energy threshold and high spatial resolution that allow for comprehensive reconstruction of event topologies. In current-generation LArTPCs, the recorded data consist of digitized waveforms on wires produced by induced signal on wires of drifting ionization electrons, which can also be viewed as two-dimensional (2D) (time versus wire) projection images of charged-particle trajectories. For such an imaging detector, one critical step is the signal processing that reconstructs the original charge projections from the recorded 2D images. For the first time, we introduce a deep neural network in LArTPC signal processing to improve the signal region of interest detection. By combining domain knowledge (e.g., matching information from multiple wire planes) and deep learning, this method shows significant improvements over traditional methods. This work details the method, software tools, and performance evaluated with realistic detector simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

spammR: an R package designed for analysis and integration of spatial multi-omic measurements

Spatial omics is a young and evolving field and as such shows rapid development of novel technologies and analysis methods to measure transcripts, proteins, metabolites, and post-translational modifications at high spatial resolution. These advances in technology have enabled the simultaneous generation of abundance profiles for multiple different omics types and associated microscopy imaging data, as well as their analysis in a spatial context. However, most analytical tools are designed for spatial transcriptomics platforms and are challenging to use in other contexts such as mass spectrometry-based measurements or metagenomics. To this end we present spammR (spatial analysis of multi-omics measurements in R), an R package that enables end-to-end analysis with a specific focus on mass-spectrometry derived spatial omics datasets with (1) smaller sample sizes and spatial sparsity of samples, (2) considerable missingness, and (3) no a-priori knowledge about proteins or genes of interest, relying on a fully data-driven approach.

spammR↗

Understanding Interfacial Electrochemical Reactions through in situ ec-STEM and IL-Cryo-STEM

A major criterion in the design of next generation materials for electrical energy storage applications is a comprehensive understanding of interfacial electrochemical reactions as well as correlating the structure and chemistry across site-specific electrode/electrolyte interfaces with electron, charge, and mass transport processes as they govern performance characteristics. Scanning transmission electron microscopy (STEM) based techniques have emerged as an indispensable materials characterization tool that provides high spatial resolution imaging and chemical analysis and has been effectively utilized to obtain an atomic to nanoscale view of the interfacial structure before and after electrochemical cycling. More recently, there have been several advances that now allows us to obtain more detailed mechanistic insight into evolving reactions through in situ ec-STEM and electrical biasing platforms such as in the understanding of the mechanisms of solid electrolyte interphase formation, lithium dendrite nucleation and growth mechanisms and ionic transport mechanisms within intercalation, conversion, and alloying electrode materials. Several major advantages of the in situ ec-STEM approach is the quantitative electrochemical measurement of charge passed during cycling with simultaneous analysis of the electrochemical processes with STEM imaging and diffraction. Here, while spectroscopic analysis of the electrochemical reactions products has been performed, there is the issue of beam sensitivity and therefore, Cryo-STEM imaging combined with electron energy loss spectroscopy (EELS) techniques have been employed to analyze the chemistry of the SEI and Li dendrites. In this talk, we discuss the potential for combining identical location (IL) STEM techniques with Cryo-EM. The advantage of using this approach is that the sample is placed on a conventional TEM grid and the exact same location of the specimen can be analyzed before and after quantitative electrochemical measurements. Moreover, since the sample is on the TEM grid, the grid itself can be prepared for further Cryo-TEM experiments by plunge freezing in liquid nitrogen then transferred to the Cryo-TEM under liquid nitrogen. Results obtain from these experiments can be used to enhance our scientific understanding of interfacial chemistry at electrode/electrolyte interfaces and may be useful in the design of new materials.

36 MATERIALS SCIENCE↗