Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High pressure instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Electrical Resistivity Tomography based monitoring of stress perturbations to optimize placement of high-precision strain meters

The Center for Understanding Subsurface Signals and Permeability is a new U.S. Department of Energy Earthshot Center focused on understanding and predicting the long-term evolution of permeability in enhanced geothermal systems. The center will use a highly instrumented testbed within the Sanford Underground Research Facility to conduct field scale experiments that elucidate and test capabilities to simulate geochemical-geomechanical interactions and permeability evolution. Here we demonstrate initial developments using previously collected electrical resistivity tomography (ERT) monitoring data with high-performance multi-physics modelling advancements to inform the optimal location of two new monitoring boreholes. Specifically, ERT monitoring data collected during shear stimulation testing shows marked responses to changes in stress during borehole pressurization. We demonstrate how the same response is being simulated, ultimately to train a machine-learning algorithm to estimate rock properties and enable enhanced prediction of stress and strain responses anticipated during future testing campaigns.

Stress, EGS, CUSSP, 3D Electrical Imaging↗

Stigmatically focusing partial pressure analyzer with dual chamber ion source

The partial pressure analyzer developed has a high absolute sensitivity and high resolution. Interaction effects, as they occur in conventional partial pressure analyzers between the heating filament for the emission of electrons and the residual gas, are suppressed by removing the heating filament from the measurement area. The electron beam is generated in an auxiliary vacuum compartment, and passes subsequently through an aperture into the ionization compartment. The probability is small, therefore, that the presence of substances produced at the heating filament by chemical reactions and thermal decompositions will have disturbing effects. The high sensitivity and resolution of the instrument are obtained with the aid of an electron path configuration of unconventional characteristics.

Rasskopf, Klaus F.↗

Diagnosis Of A Pressure-Modulator-Radiometer Cell

Spectral response of pressure-modulator-radiometer cell measured with help of lead-salt tunable diode laser. Laser chosen because of narrow bandwidths {2 x 10 to negative 4th power (cm) to negative 1st power} and relatively high powers (up to 1 mW continuous) of such lasers and because available for wavelengths from 3 to 30 micrometers. Direct measurement of spectral response enables formulation of more-precise atmospheric-transmission functions, enabling extraction of better information from readings taken with instrument.

May, Randy D.↗

Monte Carlo Bayesian Inference on a Statistical Model of Sub-gridcolumn Moisture Variability Using High-resolution Cloud Observations : Sensitivity Tests and Results - Part II

Part I presented a Monte Carlo Bayesian method for constraining a complex statistical model of GCM sub-gridcolumn moisture variability using high-resolution MODIS cloud data, thereby permitting large-scale model parameter estimation and cloud data assimilation. This part performs some basic testing of this new approach, verifying that it does indeed significantly reduce mean and standard deviation biases with respect to the assimilated MODIS cloud optical depth, brightness temperature and cloud top pressure, and that it also improves the simulated rotational-Ramman scattering cloud optical centroid pressure (OCP) against independent (non-assimilated) retrievals from the OMI instrument. Of particular interest, the Monte Carlo method does show skill in the especially difficult case where the background state is clear but cloudy observations exist. In traditional linearized data assimilation methods, a subsaturated background cannot produce clouds via any infinitesimal equilibrium perturbation, but the Monte Carlo approach allows finite jumps into regions of non-zero cloud probability. In the example provided, the method is able to restore marine stratocumulus near the Californian coast where the background state has a clear swath. This paper also examines a number of algorithmic and physical sensitivities of the new method and provides guidance for its cost-effective implementation. One obvious difficulty for the method, and other cloud data assimilation methods as well, is the lack of information content in the cloud observables on cloud vertical structure, beyond cloud top pressure and optical thickness, thus necessitating strong dependence on the background vertical moisture structure. It is found that a simple flow-dependent correlation modification due to Riishojgaard (1998) provides some help in this respect, by better honoring inversion structures in the background state.

Monte Carlo Bayesian inference↗

A Miniature Electrical Pressure Gage Utilizing a Stretched Flat Diagram

A variable-air-gap, inductance-type, electrical pressure gage is described that is basically 7/16 inch in diameter and 1/4 inch in thickness. The gage was designed to measure accurately pressures fluctuating at high frequencies and has proved to be a value as a general-purpose electrical gage for aeronautical work where small size and minimum response to acceleration forces are important factors. Design equations and curves are presented which can be used to predict the deflections and fundamental natural frequencies of stretched flat diaphragms.

INSTRUMENTS, LABORATORY↗

Particle_hygroscopicity_growth_factor_HFIMS_TRACER_2022_HOUSTON_IOP

This dataset contains high-temporal-resolution measurements of hygroscopic growth factors (GF), and instrument diagnostic/environmental parameters collected during the TRACER campaign using a coupled Differential Mobility Analyzer (DMA) and Fast Integrated Mobility Spectrometer (FIMS) system (HFIMS). The dataset consists of 49,645 time steps and covers 20 discrete growth factor bins (FIMS_GFbinc). The primary data product is the Probability Density Function (FIMS_cPDF), which characterizes aerosol hygroscopic growth behavior under controlled relative humidity conditions. Instrument operational parameters, including flow temperatures, relative humidities, pressures, and counts for both DMA and FIMS, are provided for quality assurance.

DMA_Dp_mean↗

Molecular flux measurements in the back flow region of a nozzle plume

A series of tests were conducted to measure the mass flux in the far field of a nozzle plume in a high vacuum with emphasis on the back flow region. The measurements presented provided fairly accurate data for off-axis angles as large as 140 deg (i.e., in the back flow region). This region, since it is well behind the exit plane, is of paticular interest to those concerned with instrument contamination. Usually sensitive spacecraft surfaces are located in the region affected by the back flow. Parameters such as expansion ratio, throat diameter, nozzle lip shape, and plenum (chamber) pressure were varied, carbon dioxide and nitrogen gases were flowed and mass flux measurements were taken using quartz crystal microbalances in as many as nine different locations relative to the tests nozzle. Several conclusions with respect to the effect of nozzle and gas parameters on the amount of back flow mass flux are offered, and it was demonstrated that gaseous mass fluxes, which are not predictable by present theories, are encountered in the region behind the nozzle exit plane. This knowledge is significant if materials incompatible with the gaseous exhaust products are used in this region.

Chirivella, J. E.↗

Experimental aerodynamic heating to simulated shuttle tiles

The heat transfer to simulated shuttle thermal protection system tiles was investigated experimentally using a highly instrumented metallic thin wall tile arranged with other metal tiles in a staggered tile array. Cold-wall heating rate data for laminar and turbulent flow were obtained in the Langley 8-foot high temperature tunnel at a nominal Mach number of 7, a nominal total temperature of 3300 R, free-stream unit Reynolds number from 3.4 x 10 to the 5th power to 2.2 x 10 to the 6th power per foot, and free-stream dynamic pressure of 1.8 psia to 9.1 psia. Experimental data are presented to illustrate the effects of flow angularity and gap width on both local peak heating and overall heating loads.

Avery, D. E.↗

Mechanism for generation of 2-3 kHz radiation in the outer heliosphere

The question of how low-frequency non-thermal radio emissions at the boundary of the heliosphere might be generated is considered. The mechanism consists of two steps. First, the beam of energetic electrons generates a high level of electrostatic Langmuir plasma waves. Second, electromagnetic radiation results from the non-linear interaction between Langmuir waves. Intensity of radio emissions at 2 to 3 kHz detected by the Voyager plasma wave instrument in the outer heliosphere can be explained provided that the electron beams generating Langmuir waves exist also in the postshock plasma due to secondary shocks in the compressed solar wind beyond the termination shock. Modification of the heliospheric shocks by the cosmic ray pressure is also taken into account. The field strengths of Langmuir waves required to generate the second harmonic emissions are of 50 to 100 microvolts per meter. These waves may be observed in situ by Voyager 1 and 2 in the near future.

Macek, W. M.↗

The Ceres S'COOL Project: Two Years After First Launch

The idea for the Students' Cloud Observations OnLine (S'COOL) project as an outreach and education element of NASA's Clouds and the Earth's Radiant Energy System (CERES) research program was conceived in late 1996 during a conversation with a middle school science teacher. S'COOL was implemented in a series of increasingly developed test phases during 1997, as the launch of the first CERES instrument approached. Even before launch, the reception of the project in schools far exceeded expectations. After several delays the first instrument, on the Tropical Rainfall Measuring Mission (TRMM) spacecraft, was launched on Thanksgiving Day, 1997. Since the first launch, development and expansion of the project has continued with expectations for launch of Terra carrying two CERES instruments into a polar orbit in mid-1998. That launch is now expected in fall 1999, and will finally provide overflight of all participating schools. In two years, the project has grown from three initial test participants to over 300 schools now participating in 23 countries on five continents. Students from first grade through university level are involved (most participants are ages 10-15). S'COOL is also being used by a few education professors to teach about Internet use in the classroom. The project continues to grow through word of mouth, presentations at teacher workshops, and now increasingly through teachers who find it during web searches. Participants in the S'COOL project are part of the CERES validation team. They provide ground truth measurements at the time the CERES instrument flies over their location, to be compared with the retrieval of cloud properties by remote sensing from CERES. Quantities reported include cloud type, height, fraction and opacity; information on contrails; surface temperature, pressure and relative humidity; and ground cover (snow/ice, wet, dry; leaves on trees or not). in addition, a comment field on the report form serves as a catch-all for all kinds of interesting observations, including similes written by some classes to describe more exactly the clouds they see. Several not totally unexpected complications with the CERES instrument and processing software mean that the CERES team has not yet reached the point of computing the cloud properties, a high level product at the end of the processing stream. However, progress is being made and we anticipate that we will soon be populating the S'COOL database with a large number of satellite retrievals for comparison with the students' observations. Some satellite retrievals from the initial test phases are already available in the database, The CERES instruments are planned to operate at least through 2006, and the S'COOL Project is planned to continue at least that long, providing motivational learning to as many students as possible. This paper reports on the first several years of the S'CCOL project. It further reports on some of the noteworthy observations and comparisons made possible by this project. Schools are often located in interesting places, in terms of the clouds found there and the satellite's ability to observe these clouds. The paper also reports on the learning opportunities delivered by this project, and on new questions about the planet and its climate which arise in the students' minds as a result of their active participation.

Chambers, Lin H.↗

Supersonic Retropropulsion Experimental Results from the NASA Langley Unitary Plan Wind Tunnel

A new supersonic retropropulsion experimental effort, intended to provide code validation data, was recently completed in the Langley Research Center Unitary Plan Wind Tunnel Test Section 2 over the Mach number range from 2.4 to 4.6. The experimental model was designed using insights gained from pre-test computations, which were instrumental for sizing and refining the model to minimize tunnel wall interference and internal flow separation concerns. A 5-in diameter 70-deg sphere-cone forebody with a roughly 10-in long cylindrical aftbody was the baseline configuration selected for this study. The forebody was designed to accommodate up to four 4:1 area ratio supersonic nozzles. Primary measurements for this model were a large number of surface pressures on the forebody and aftbody. Supplemental data included high-speed Schlieren video and internal pressures and temperatures. The run matrix was developed to allow for the quantification of various sources of experimental uncertainty, such as random errors due to run-to-run variations and bias errors due to flow field or model misalignments. Preliminary results and observations from the test are presented, while detailed data and uncertainty analyses are ongoing.

Berry, Scott A.↗

Application of an ultrasonic focusing radiator for acoustic levitation of submillimeter samples

An acoustic apparatus has been specifically developed to handle samples of submillimeter size in a gaseous medium. This apparatus consists of an acoustic levitation device, deployment devices for small liquid and solid samples, heat sources for sample heat treatment, acoustic alignment devices, a cooling system and data-acquisition instrumentation. The levitation device includes a spherical aluminum dish of 12 in. diameter and 0.6 in. thickness, 130 pieces of PZT transducers attached to the back side of the dish and a spherical concave reflector situated in the vicinity of the center of curvature of the dish. The three lowest operating frequencies for the focusing-radiator levitation device are 75, 105 and 163 kHz, respectively. In comparison with other levitation apparatus, it possesses a large radiation pressure and a high lateral positional stability. This apparatus can be used most advantageously in the study of droplets and spherical shell systems, for instance, for fusion target applications.

Lee, M. C.↗

The measurement of maximum cylinder pressures

The work presented in this report was undertaken at the Langley Memorial Aeronautical Laboratory of the National Advisory Committee for Aeronautics to determine a suitable method for measuring the maximum pressures occurring in aircraft engine cylinders. The study and development of instruments for the measurement of maximum cylinder pressures has been conducted in connection with carburetor and oil engine investigations on a single cylinder aircraft-type engine. Five maximum cylinder-pressure devices have been designed, and tested, in addition to the testing of three commercial indicators. Values of maximum cylinder pressures are given as obtained with various indicators for the same pressures and for various kinds and values of maximum cylinder pressures, produced chiefly by variation of the injection advance angle in high-speed oil engine. The investigations indicate that the greatest accuracy in determining maximum cylinder pressures can be obtained with an electric, balanced-pressure, diaphragm or disk-type indicator so constructed as to have a diaphragm or disk of relatively large area and minimum seat width and mass.

Hicks, Chester W↗

Analysis of Deformation and Fracture Mechanisms in the Harvested High-Dose Baffle-Former Bolt with Stress-Corrosion Cracks Formed While in Service

This report presents the results of advanced mechanical testing conducted on miniature tensile specimens excised from an irradiated baffle-former bolt, a commercial pressurized water reactor component. The specimens were extracted from the midsection of the bolt shank, where the estimated damage dose reached 23 displacements per atom. The mechanical testing included the following tests: (1) conventional tensile testing at room temperature, augmented by digital image correlation (DIC) to enable noncontact strain measurements, and (2) in situ tensile testing within a scanning electron microscopy (SEM) instrument equipped with energy-dispersive x-ray spectroscopy (EDS) and electron backscatter diffraction (EBSD) detectors to evaluate active deformation and fracture mechanisms. Additionally, SEM fractographic analysis revealed alterations in the fracture mechanism from a predominantly ductile fracture in nonirradiated steel to a mixed fracture mode (still dominating ductile and minor cleavage spots) in irradiated specimens derived from the baffle bolts. The findings indicate a complex strain localization behavior for in-service irradiated steel specimens. Beyond conventional necking at the macro scale and defect-free channel formation at the micro scale, DIC results identified the presence of deformation bands approximately 100 μm in width. These bands consist of chains of grains exhibiting elevated local strain levels and may be considered an intermediate or mesoscale level of strain localization. These bands become discernible near the yield stress as localized hot spots, areas of elevated strain, persisting throughout most of the experiment. The formation of mesoscale deformation bands as a strain localization mechanism may exacerbate the defect-free channel formation in irradiated materials, further promoting irradiation-assisted stress corrosion crack initiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ammonia Leak Locator Study

The thermal control system of International Space Station Alpha will use liquid ammonia as the heat exchange fluid. It is expected that small leaks (of the order perhaps of one pound of ammonia per day) may develop in the lines transporting the ammonia to the various facilities as well as in the heat exchange equipment. Such leaks must be detected and located before the supply of ammonia becomes critically low. For that reason, NASA-JSC has a program underway to evaluate instruments that can detect and locate ultra-small concentrations of ammonia in a high vacuum environment. To be useful, the instrument must be portable and small enough that an astronaut can easily handle it during extravehicular activity. An additional complication in the design of the instrument is that the environment immediately surrounding ISSA will contain small concentrations of many other gases from venting of onboard experiments as well as from other kinds of leaks. These other vapors include water, cabin air, CO2, CO, argon, N2, and ethylene glycol. Altogether, this local environment might have a pressure of the order of 10(exp -7) to 10(exp -6) torr. Southwest Research Institute (SwRI) was contracted by NASA-JSC to provide support to NASA-JSC and its prime contractors in evaluating ammonia-location instruments and to make a preliminary trade study of the advantages and limitations of potential instruments. The present effort builds upon an earlier SwRI study to evaluate ammonia leak detection instruments [Jolly and Deffenbaugh]. The objectives of the present effort include: (1) Estimate the characteristics of representative ammonia leaks; (2) Evaluate the baseline instrument in the light of the estimated ammonia leak characteristics; (3) Propose alternative instrument concepts; and (4) Conduct a trade study of the proposed alternative concepts and recommend promising instruments. The baseline leak-location instrument selected by NASA-JSC was an ion gauge.

Dodge, Franklin T.↗

Atmospheric Fluorescence Yield

Several existing and planned experiments estimate the energies of ultra-high energy cosmic rays from air showers using the atmospheric fluorescence from these showers. Accurate knowledge of the conversion from atmospheric fluorescence to energy loss by ionizing particles in the atmosphere is key to this technique. In this paper we discuss a small balloon-borne instrument to make the first in situ measurements versus altitude of the atmospheric fluorescence yield. The instrument can also be used in the lab to investigate the dependence of the fluorescence yield in air on temperature, pressure and the concentrations of other gases that present in the atmosphere. The results can be used to explore environmental effects on and improve the accuracy of cosmic ray energy measurements for existing ground-based experiments and future space-based experiments.

Adams, James H., Jr.↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Embedded Data Acquisition Tools for Rotorcraft Diagnostic Sensors

Rotorcraft drive trains must withstand enormous pressure while operating continuously in extreme temperature and vibration environments. Captive components, such as planetary and spiral bevel gears, see enormous strain but are not accessible to fixed instrumentation, such as a piezoelectric transducer. Thus, it is difficult to directly monitor components that are most susceptible to damage. This innovation is a self-contained data processing unit within a specialized fixture that installs directly inside the rotating pinion gear in the gearbox. From this location, it detects and transmits high-resolution prognostic data to a fixed transceiver. The sensor is based on microelectromechanical systems (MEMS) technology and uses innovative circuit designs to capture high-bandwidth data and transmit it wirelessly from inside an operational helicopter transmission. With Ridgetop's advanced MEMS-based sensor, researchers have, for the first time, been able to extract high-resolution acoustic signatures wirelessly from sensors within the transmission that would otherwise be muffled by background gear noises. Ridgetop's innovative instrument will help researchers perform dynamic analysis of gear interaction and develop improved designs for gear components. In addition, data from this instrument can be used to validate new algorithms that detect and predict faults based on external acoustic signatures, for prognostic purposes. The result of this work will be an improvement in safety, performance, and cost for future generations of rotating components.

Wagoner, Robert↗