Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

High Value Opportunities to Advance Automation in Electric Grid Control Rooms

Grid operators and electric utilities are increasingly driven to develop automated processes and introduce decision support tools to reduce cognitive demand on System Operations staff and aid in the operational decision-making process. However, System Operation staff are traditionally hesitant to implement and accept new solutions, automation processes, and tools within the control room. This paper explores high-value opportunities to advance automation in electric grid control rooms for the purpose of improving grid safety, reliability, and resiliency during normal and emergency operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Maintaining Grid Reliability: Lessons From Renewable Integration Studies

The U.S. Department of Energy (DOE) and other organizations have sponsored numerous research studies over the last two decades to examine the effect of increased wind and solar deployment on grid reliability, including a number of studies that examine grids deriving more than 50% of annual energy from wind and solar. In this report, we discuss key findings from both the research body of knowledge and real-world practice related to grid reliability, and we demonstrate how to plan for and achieve continued reliability in the future as wind and solar deployment increase.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Workshop Summary: Bridging the Gap Between Atmospheric Science and Grid Integration

The need for dedicated, accurate, expertly curated weather data is increasingly important as the share of variable renewable energy increases on the power system. Projections for futures with very high (50+% annual energy) shares of variable generation require ongoing assessment of data requirements from industry stakeholders in their power system operation and planning contexts. In March 2024, NREL organized a workshop entitled "Bridging the Gap Between Atmospheric Science and Grid Integration Workshop", which brought atmospheric scientists and power system experts together to refine the requirements of atmospheric datasets for grid integration, and to describe a holistic approach to creating new and regularly updated national scale wind datasets for power system planning and operations. The results of this workshop are being used to inform the near-term development and a longer-term strategy for DOE to produce relevant wind resource datasets and inform wider use of wind/solar/load data sets in power system planning. This presentation provides an overview of a preworkshop survey, an assessment of current state of the art of national-scale datasets for wind resource assessment and grid integration, insights on appropriate uses of the WTK-LED, power system perspectives on data needs, as well as recommended next steps as discussed in the workshop and how these steps support longer-term strategies.

17 WIND ENERGY↗

Grid Expansion Optimal Planning Tools (GridEO): Manual for Users and Developers

This report describes Grid Expansion Optimal Planning Tools (GridEO). GridEO is a Python package for electric power grid capacity expansion modeling. With GridEO, the user can build and solve instances of the Capacity Expansion Planning (CEP) problem to determine an optimal plan of investment in capacity of various types of power grid equipment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-Hardware-in-the-Loop Experiments of a Microgrid with a Grid-Forming Battery Inverter

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UNIFI Specifications for Grid-Forming Inverter-Based Resources: Version 3

The UNiversal Interoperability for grid-Forming Inverters (UNIFI) Consortium addresses fundamental challenges facing the integration of grid-forming (GFM) inverters in electric grids alongside rotating machines and other inverter-based resources (IBRs). This document defines a set of UNIFI specifications for GFM IBRs that provides requirements from both a power system level as well as functional requirements at the inverter level that are intended to provide means for the vendor-agnostic operation of GFM IBRs at any scale in electric power systems.

14 SOLAR ENERGY↗

Key Performance Indicators for Vehicle Grid Integration

Electric vehicle (EV) sales account for a rapidly growing portion of the light-duty vehicle market and a portion of medium and heavy-duty fleet vehicles. However, in many locations, charging stations will require costly utility grid upgrades with long lead times. Today, there are a few methods of smart charge management (SCM) which can reduce the costs and wait times for electric vehicle supply equipment (EVSE) interconnection approvals, as well as reduce impacts of the charging stations on the grid and on EV driver transportation costs. It is crucial for the EV charging industry to understand the vehicle grid integration (VGI) requirements for EVSE to prevent adverse impacts from EVSE interconnections and assure that charging loads and interconnections are affordable.

33 - ADVANCED PROPULSION SYSTEMS↗

Developing a Framework for Valuation of Grid Services

The electric system is rapidly evolving and growing, raising new questions about how to define and value grid services delivered by a diverse set of resources, including customer-owned assets. This report advances a service–parameter–value framework that links what a grid service does to why it matters, and how its benefits are evidenced. We build upon prior efforts (Bender et al. 2021) and extend them to include value categories (reliability, resilience, cost & access, and security) with primary and secondary tiers, service-specific value streams that explain how benefits materialize, and metrics that make valuation traceable and comparable. We apply the framework to the six core grid services defined in (Kolln et al. 2023): Frequency Response, Regulation, Reserves, Energy, Voltage Management, and Blackstart and demonstrate it on three use cases to highlight the adaptability of these value streams. Further, we outline how the framework integrates with existing tools such as asset optimization, hosting capacity and cost-benefit analysis, and propose a path to portable qualifications and consistent stacking rules for use in tariffs and filings. Finally, we identify future pathways for research and application research needs to support standardization and decision-ready comparisons across services, assets, and architectures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel Hybrid Current Limiter for Grid-Forming Inverter Control During Unbalanced Faults

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable the bulk integration of renewable resources into the future power grid; however, the performance of GFM inverters during unbalanced faults remains underexplored. This paper proposes a novel current-limiting method for GFM inverters to handle unbalanced fault conditions while providing voltage support to the main grid. The proposed current limiter combines concepts of dynamic virtual-impedance and current-reference saturation limiting, all built in the stationary reference frame, to achieve improved current-limiting performance under unbalanced load/fault conditions. System-wide full-order transient simulations with multiple GFM inverters demonstrate the potential of the method and benchmark the performance against state-of-the-art current limiters. Simulation results portray improved voltage balancing performance of the proposed method compared to both current-reference saturation and virtual-impedance limiting.

controller anti windup↗

A Generic Primary-Control Model for Grid-Forming Inverters: Towards Interoperable Operation & Control

This paper outlines an architectural vision centered around the notion of interoperability to integrate grid-forming inverter-based resources in large-scale grids. With the underlying principle of interoperability guiding developments, we focus on modeling the characteristics of droop, virtual synchronous machine, and virtual oscillator controls. Emphasis is placed on these three controllers since they are leading grid-forming control candidates and are likely to be commonplace as primary-control schemes in future systems. We show that these controllers can each be considered as instantiations of a more generic model and that all these controllers exhibit similar droop-like relations between pertinent terminal variables in steady state. This commonality between controllers gives interoperability among them such that automatic synchronization, power sharing, and voltage regulation can be achieved. Simulation results validate the models and demonstrate how the steady-state droop characteristics of these control methods can be aligned with the aid of the developed modeling paradigm.

control↗

Cyber-physical cascading failure and resilience of power grid: A comprehensive review

Smart grid technologies are based on the integration of the cyber network and the power grid into a cyber-physical power system (CPPS). The increasing cyber-physical interdependencies bring about tremendous opportunities for the modeling, monitoring, control, and protection of power grids, but also create new types of vulnerabilities and failure mechanisms threatening the reliability and resiliency of system operation. A major concern regarding the interdependent networks is the cascading failure (CF), where a small initial disturbance/failure in the network results in a seemingly unexpected large-scale failure. Although there has been a significant volume of recent work in the CF research of CPPS, a comprehensive review remains unavailable. This article aims to fill the gap by providing a systematic literature survey regarding the modeling, analysis, and mitigation of CF in CPPS. The open research questions for further research are also discussed. This article allows researchers to easily understand the state of the art of CF research in CPPS and fosters future work required towards full resolutions to the remaining questions and challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Envelope- and Machine Learning-Based Electrical Fault Type Detection Algorithms for Electrical Distribution Grids

This study introduces envelope- and machine learning (ML)-based electrical fault type detection algorithms for electrical distribution grids, advancing beyond traditional logic-based methods. The proposed detection model involves three stages: anomaly area detection, ML-based fault presence detection, and ML-based fault type detection. Initially, an envelope-based detector identifying the anomaly region was improved to handle noisier power grid signals from meters. The second stage acts as a switch, detecting the presence of a fault among four classes: normal, motor, switching, and fault. Finally, if a fault is detected, the third stage identifies specific fault types. This study explored various feature extraction methods and evaluated different ML algorithms to maximize prediction accuracy. The performance of the proposed algorithms is tested in an emulated software–hardware electrical grid testbed using different sample rate meters/relays, such as SEL735, SEL421, SEL734, SEL700GT, and SEL351S near and far from an inverter-based photovoltaic array farm. The performance outcomes demonstrate the proposed model’s robustness and accuracy under realistic conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward Wireless Smart Grid Communications: An Evaluation of Protocol Latencies in an Open-Source 5G Testbed

Fifth-generation networks promise wide availability of wireless communication with inherent security features. The 5G standards also outline access for different applications requiring low latency, machine-to-machine communication, or mobile broadband. These networks can be advantageous to numerous applications that require widespread and diverse communications. One such application is found in smart grids. Smart grid networks, and Operational Technology (OT) networks in general, utilize a variety of communication protocols for low-latency control, data monitoring, and reporting at every level. Transitioning these network communications from wired Wide Area Networks (WANs) to wireless communication through 5G can provide additional benefits to their security and network configurability. However, introducing these wireless capabilities may also result in a degradation of network latency. In this paper, we propose utilizing 5G for smart grid communications, and we evaluate the latency impacts of encapsulating GOOSE, Modbus, and DNP3 for transmission over a 5G network. The OpenAirInterface open-source library is utilized to deploy an in-lab 5G Core Network and gNB for testing with off-the-shelf User Equipment (UE). This creates an effective 5G test platform for experimenting with different OT protocols such as GOOSE. The results are validated by measuring two different Intelligent Electronic Devices’ contact closure times for each network configuration. These tests are also conducted for varying packet sizes in order to isolate different sources of network latency. Our study outlines the latency impact of communication over 5G for time-critical and non-critical applications regarding their transition toward private 5G-based OT network implementations. The conducted experiments illustrate that in the case of GOOSE packets, simple encapsulation may exceed the protocol’s time-critical nature, and, therefore, additional measures must be taken to ensure a viable transition of GOOSE to 5G services. However, non-critical applications are shown to be viable for migration to 5G.

42 ENGINEERING↗

Time Synchronization Techniques in the Modern Smart Grid: A Comprehensive Survey

In modern smart grids, accurate and synchronized time signals are essential for effective monitoring, protection, and control. Various time synchronization methods exist, each tailored to specific application needs. Widely adopted solutions, such as GPS, however, are vulnerable to challenges such as signal loss and cyber-attacks, underscoring the need for reliable backup or supplementary solutions. This paper examines the timing requirements across different power grid applications and provides a comprehensive review of available time synchronization mechanisms. Through a comparative analysis of timing methods based on accuracy, flexibility, reliability, and security, this study offers insights to guide the selection of optimal solutions for seamless grid integration.

comparison↗

Fabrication of Black Body Grids by Thick Film Printing for Quantitative Neutron Imaging

Neutron imaging offers deep penetration through many high-Z materials while also having high sensitivity to certain low-Z isotopes such as 1H, 6Li, and 10B. This unique combination of properties has made neutron imaging an attractive tool for a wide range of material science and engineering applications. However, measurements made by neutron imaging or tomography are generally qualitative in nature due to the inability of detectors to discriminate between neutrons which have been transmitted through the sample and neutrons which are scattered by the sample or within the detector. Recent works have demonstrated that deploying a grid of small black bodies (BBs) in front of the sample can allow for the scattered neutrons to be measured at the BB locations and subsequently subtracted from the total measured intensity to yield a quantitative transmission measurement. While this method can be very effective, factors such as the scale and composition of the sample, the beam divergence, and the resolution and construction of the detector may require optimization of the grid design to remove all measurement biases within a given experimental setup. Therefore, it is desirable to have a method by which BB grids may be rapidly and inexpensively produced such that they can easily be tailored to specific applications. In this work, we present a method for fabricating BB patterns by thick film printing of Gd2O3 and evaluate the performance with variation in feature size and number of print layers with cold and thermal neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimal Operation of PV Sources in DC Grids for Improving Technical, Economical, and Environmental Conditions by Using Vortex Search Algorithm and a Matrix Hourly Power Flow

This document presents a master–slave methodology for solving the problem of optimal operation of photovoltaic (PV) distributed generators (DGs) in direct current (DC) networks. This problem was modeled using a nonlinear programming model (NLP) that considers the minimization of three different objective functions in a daily operation of the system. The first one corresponds to the minimization of the total operational cost of the system, including the energy purchasing cost to the conventional generators and maintenance costs of the PV sources; the second objective function corresponds to the reduction of the energy losses associated with the transport of energy in the network, and the third objective function is related to the minimization of the total emissions of CO2 by the conventional generators installed on the DC grid. The minimization of these objective functions is achieved by using a master–slave optimization approach through the application of the Vortex Search algorithm combined with a matrix hourly power flow. To evaluate the effectiveness and robustness of the proposed approach, two test scenarios were used, which correspond to a grid-connected and a standalone network located in two different regions of Colombia. The grid-connected system emulates the behavior of the solar resource and power demand of the city of Medellín-Antioquia, and the standalone network corresponds to an adaptation of the generation and demand curves for the municipality of Capurganá-Choco. A numerical comparison was performed with four optimization methodologies reported in the literature: particle swarm optimization, multiverse optimizer, crow search algorithm, and salp swarm algorithm. The results obtained demonstrate that the proposed optimization approach achieved excellent solutions in terms of response quality, repeatability, and processing times.

14 SOLAR ENERGY↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗