Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRATINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

E-beam generated holographic masks for optical vector-matrix multiplication

An optical vector matrix multiplication scheme that encodes the matrix elements as a holographic mask consisting of linear diffraction gratings is proposed. The binary, chrome on glass masks are fabricated by e-beam lithography. This approach results in a fairly simple optical system that promises both large numerical range and high accuracy. A partitioned computer generated hologram mask was fabricated and tested. This hologram was diagonally separated outputs, compact facets and symmetry about the axis. The resultant diffraction pattern at the output plane is shown. Since the grating fringes are written at 45 deg relative to the facet boundaries, the many on-axis sidelobes from each output are seen to be diagonally separated from the adjacent output signals.

Arnold, S. M.↗

MAGELLAN: High resolution spectroscopy at FUV and EUV wavelengths

The aim of ESA's MAGELLAN mission is to provide high resolution spectra of celestial sources down to sixteenth magnitude over the extreme ultraviolet wavelength range (between 50 and 140 nm). This range extends from studies of interstellar matter in the disc and halo of this and other galaxies, to stellar envelopes, hot and evolved stars, clusters, intergalactic matter, nuclei of galaxies, quasars, and, finally, planets and satellites. The instrument has a nonconventional optical design using only one reflecting surface; a high groove density concave grating collects the star light, diffracts it and focuses its spectrum into a bidimensional windowless detector operated in a photon counting mode. The slitless configuration provides the spectra of all the sources (point like and extended) in the field of view of the grating. This field of view is limited by a grid collimator to reduce the diffuse background, the stray light and the probability of overlapping spectra in crowded fields.

Grewing, M.↗

Echelle spectrographs at grazing incidence

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Cash, W.↗

Discovery of carbon stars in the Draco dwarf spheroidal galaxy

A grating prism survey of the Draco dwarf spheroidal galaxy that is 97% areally complete has led to the discovery of three carbon stars. Membership of these stars in Draco is firmly established from luminosity, proper motion, and radial velocity considerations. Optical and preliminary infrared photometry suggest that the Draco carbon stars are more closely related to the CH stars in omega Cen than to the luminous carbon stars found in the Fornax and Carina dwarfs. One of the carbon stars possesses an unusual emission line spectrum which might be indicative of either a very hot degenerate companion or a preplanetary evolutionary stage. Carbon stars have now been located in all four of the dwarf spheroidals that have been examined using transmission grating prism techniques. The rarity of these stars in galactic globulars, systems with which the dwarf spheroidals are often compared, indicates a fundamental population difference whose cause is not yet fully understood.

Aaronson, M.↗

An intercomparison of ground-based total ozone instruments

Five ground-based total ozone spectrophotometers were intercompared at Wallops Island, VA between October 1979 and January 1981. The tests were conducted to evaluate the stability and accuracy of each instrument over an extended time period. Acceptable performance regarding these two characteristics is essential if an instrument is to be useful in field measurements and network monitoring of the atmospheric total ozone content. The Dobson spectrophotometer was used as the standard of comparison for the Brewer grating spectrophotometer, the USSR M-83 ozonometer, the Canterbury filter photometer, and the SenTran filter photometer. The grating instrument was found to be potentially the equal of the Dobson but was subject to unreliable performance by its rather sophisticated electronic components. The filter photometers performed acceptably for short periods but filter aging and eventual degradation rendered both units unusable before the end of the intercomparison. Finally, the M-83 results were found to be in acceptable agreement with the Dobson throughout the period when certain qualifications are invoked. The accuracy of a single M-83 ozone measurement may be low. Averages tend to improve its agreement with the Dobson.

Parsons, C. L.↗

Moire interferometry for thermal expansion of composites

Moire interferometry by reflection is described and demonstrated for the case of a real reference grating of 1200 lines/mm. Extraneous beams can be displaced and stopped by using a wedge-shaped air gap between reference and specimen gratings. Double-order dominance, the use of diffraction sequences for reflection, the isolation of preferred sequences, and the use of two-beam interference are discussed. Experimental accuracy is enhanced significantly by using several data points to establish displacements along a line, and random errors characterized by one standard deviation can be as small as one microstrain. The method is well adapted to thermal environments, coefficients of thermal expansion of selected graphite-epoxy laminates being determined in the temperature range of 297-422 K. Very good precision was achieved for a wide range of thermal expansion coefficients, from approximately zero to 27 microstrains/K.

Bowles, D. E.↗

X-ray spectrum of Capella and its relation to coronal structure and ultraviolet emission

The binary system Capella has been observed on 1979 March 15 and on 1980 March 15-17, with the objective grating spectrometer on board the Einstein Observatory. The spectrum measured with the 1000 1/mm grating covers the range 5-30 A with a resolution less than 1 A. The spectra show evidence for a bimodal temperature distribution of emission measure in an optically thin plasma with one component about 5,000,000 K and the other one about 10,000,000 K. Spectral features can be identified with line emissions from O VIII, Fe XVII, Fe XVIII, Fe XXIV, and Ne X ions. Good spectral fits have been obtained assuming standard cosmic abundances. The data are interpreted in terms of emission from hot static coronal loops rather similar to the magnetic arch structures found on the sun. It is shown that the conditions for such a model can exist on Capella. Typical values of loop base pressure and half-length are derived for both temperature components and discussed in relation to UV observations.

Mewe, R.↗

Simplified Laser Tuning

Tuning arrangement employs single grating and two planar mirrors. Arrangement of front-surface mirrors and single holographic grating significantly reduces spectral bandwidth and simplified tuning of laser output. Laser used to induce fluorescence in measuring concentrations of trace species, such as OH radical, in atmosphere.

Mcdermid, I. S.↗

JPL airborne instruments activities

Two instruments intended for flight aboard aircraft for research in advanced remote sensing of the earth are under development: the airborne imaging spectrometer (AIS) and the airborne visible-infrared imaging spectrometer (AVIRIS). The AIS utilizes a 32 x 32 element HgCdTe CCD array to gather 10nm spectral data, initially in the 1.2 to 2.4 micron range, with 32 pixels of cross-track spatial data. The instrument acquires 128 channels of spectral data by using a grating spectrometer whose grating is stepped through four positions during a fraction of an IFOV time on the ground. With an IFOV of 2 mrad, the GIFOV at the design altitude of 3 km is 6m. The instrument has several on-board processing capabilities including ax+b corrections for detector calibration, cross-track and down-track pixel summing, spectral band summing, and variable integration time to allow flight at various altitudes and velocities. The AVIRIS uses a proven scanning mechanism to acquire the spatial data in a whisk broom mode. The spectral coverage is from 0.35 to 2.5 microns at bandwidths ranging from 10 to 20 nm.

Vane, G.↗

Development of the multiwavelength monolithic integrated fiber optics terminal

This paper describes the development of the Multiwavelength Monolithic Integrated Fiber Optic Terminal (MMIFOT) for the NASA Johnson Space Center. The program objective is to utilize guided wave optical technology to develop wavelength-multiplexing and -demultiplexing units, using a single mode optical fiber for transmission between terminals. Intensity modulated injection laser diodes, chirped diffraction gratings and thin film lenses are used to achieve the wavelength-multiplexing and -demultiplexing. The video and audio data transmission test of an integrated optical unit with a Luneburg collimation lens, waveguide diffraction grating and step index condensing lens is described.

Chubb, C. R.↗

Progress report on the high resolution spectrograph for the Space Telescope

The instrument design is complete and many components and subsystems have been manufactured and tested. Solar-blind, multichannel, pulse counting detectors for two ultraviolet spectral bands have been developed and satisfactory flight units have been chosen. A large, lightweight graphite-epoxy optical bench, utilizing fingerplate joints with no metallic parts in order to minimize thermal expansion, has been built. Tests of the engineering model torque-motor-driven grating carrousel indicate that this critical system exceeds tight specifications for accurate and repeatable angular positioning. A complement of large, high-frequency gratings and an echelle is being completed in several laboratories. Software resident in a computer on the spacecraft will control the spectrograph with the capability to alter procedures in response to real-time evaluation of the data.

Brandt, J. C.↗

X-ray spectrograph design

An aberration theory is applied to spectrograph design. The initial system considered has a toroidal mirror in front of a concave grating spectrograph, giving spatial resolution perpendicular to the dispersion direction. The accuracy of the theory is shown by comparison of spot diagrams obtained from the aberrations with those produced by raytracing. The major aberrations affecting the vignetting at the intermediate slit and the spatial resolution are identified. A new system, using a holographic grating to give a flat focal plane, is then designed and optimized. It has increased spatial resolution over the wavelength range and is particularly suitable for microchannel array detectors.

Chrisp, M. P.↗

Integrated optical circuits for numerical computation

The development of integrated optical circuits (IOC) for numerical-computation applications is reviewed, with a focus on the use of systolic architectures. The basic architecture criteria for optical processors are shown to be the same as those proposed by Kung (1982) for VLSI design, and the advantages of IOCs over bulk techniques are indicated. The operation and fabrication of electrooptic grating structures are outlined, and the application of IOCs of this type to an existing 32-bit, 32-Mbit/sec digital correlator, a proposed matrix multiplier, and a proposed pipeline processor for polynomial evaluation is discussed. The problems arising from the inherent nonlinearity of electrooptic gratings are considered. Diagrams and drawings of the application concepts are provided.

Verber, C. M.↗

High-resolution soft X-ray spectra of Scorpius X-1 - The structure of circumsource accreting material

Four observations of Scorpius X-1 with the Objective Grating Spectrometer of the Einstein Observatory have provided high-resolution spectra (lambda/Delta lambda = approximately 20-50) in the wavelength range 7-46 A. The spectra reveal the presence of absorption structure due to oxygen, nitrogen, and iron, and variable emission structure associated with ionized iron and nitrogen. The strengths of these features suggest that the N/O abundance ratio in the absorbing and line emitting gas is anomalously high, which might indicate that these spectral components are associated with processed material, probably accreting matter transferred from the surface of an evolved companion. Constraints on the inclination of the system, however, imply that this cool, dense, accreting material must be well out of the plane of the binary system. Possible models for the origin and nature of this circumsource medium are discussed. An extensive discussion of the calibration of the Objective Grating Spectrometer and of the analysis of spectra acquired by that instrument is also provided.

Kahn, S. M.↗

A Far Infrared Echelle Spectrometer for the Kuiper Airborne Observatory

A liquid-helium-cooled grating spectrometer (CGS) is being developed as a facility instrument for the Kuiper Airborne Observatory (KAO), primarily to study for infrared lines originating in the interstellar medium. A maximum resolving power of approximately 6000 is achieved by means of a 45 cm long Echelle grating and is optically capable of operating in the spectral range from 25 to 300 microns. An array of detectors is used to simultaneously measure a line and the adjacent continuum from astronomical sources. Currently six detectors allow measurements in the 30 to 120 micron spectral band. The instrument, its operation, and its performance are described.

Erickson, E. F.↗

Solar energy converter using surface plasma waves

Sunlight is dispersed over a diffraction grating formed on the surface of a conducting film on a substrate. The angular dispersion controls the effective grating period so that a matching spectrum of surface plasmons is excited for parallel processing on the conducting film. The resulting surface plasmons carry energy to an array of inelastic tunnel diodes. This solar energy converter does not require different materials for each frequency band, and sunlight is directly converted to electricity in an efficient manner by extracting more energy from the more energetic photons.

Anderson, L. M.↗

Moire interferometry for deformation and strain studies

Recent advances in high sensitivity more interferometry are described. In-plane displacement fields are shown for very challenging problem areas: adhesive joints in tension and in bending, flexure of quasi-isotropic composite laminates, and fatigue cracks in aluminum. Reference gratings with 2400 lines/mm (60,690 l/in) were used, providing a sensitivity of 0.417 micron/fringe order (16.4 microinch./fringe order). Excellent fringe contrast was obtained in all cases, even for gradients of 64 fringes/mm (1600 fringes/in.). A four-beam optical system to produce two orthogonal virtual reference gratings was employed. The question of unknown relative displacements in two-body problems was answered by use of a soft bridge between the bodies to provide a continous path for the fringe count.

Post, D.↗

Application of a computable model of human spatial vision to phase discrimination

A computable model of human spatial vision is used to make predictions for phase-discrimination experiments. This model is being developed to deal with a broad range of problems in vision and was not specifically formulated to deal with phase discrimination. In the model, cross-correlation of the stimuli with an array of sensors produces feature vectors that are operated on by a position-uncertain ideal observer to simulate detection and discrimination experiments. In this report, the stimuli are compound sinusoidal gratings composed of a fundamental and a higher-frequency component added in various phases. Model predictions are compared with three key results from the literature: (1) the effect of the contrast of the fundamental on phase discrimination, (2) threshold phase difference as a function of the fundamental frequency, and (3) the contrast required for phase discrimination as a function of the frequency ratio of the two grating components. In the first two cases, the predictions capture the main features of the data, although quantitative discrepancies remain. In the third case, the model fails, and this failure suggests additional restrictions on the combination of information across sensors.

Nielsen, K. R. K.↗