Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Design development and manufacture of a breadboard radio frequency mass gauging system. Volume 1: Phase B final report

The applicability of the RF Mode Counting technique for gauging liquid oxygen and liquid hydrogen under all attitude conditions was demonstrated using a vacuum jacketed test tank mounted on a remotely controlled gimbaling mechanism. In addition, the technique was successfully tested using liquid oxygen in a large NASA test tank as the tank was filled and emptied. To further substantiate the capabilities of the RF Mode Counting technique as applied to applications involving zero gravity conditions, a test system using benzene as a test fluid was flight tested in a KC-135 test aircraft. This testing involved a number of zero "g" maneuvers with various quantities of the test fluid. A series of tests were also performed to evaluate the relative effects of the presence of capillary liquid retention screens on the RF Gauging technique. These tests involved considerations of system Q reductions, RF leakage through retention screens, and surface wetting effects.

Source record↗

Appearance of gauge structure in simple dynamical systems

By generalizing a construction of Berry and Simon, it is shown that non-Abelian gauge fields arise in the adiabatic development of simple quantum mechanical systems. Characteristics of the gauge fields are related to energy splittings, which may be observable in real systems. Similar phenomena are found for suitable classical systems.

Wilczek, F.↗

Feasibility of a nuclear gauge for fuel quantity measurement aboard aircraft

Capacitance fuel gauges have served as the basis for fuel quantity indicating systems in aircraft for several decades. However, there have been persistent reports by the airlines that these gauges often give faulty indications due to microbial growth and other contaminants in the fuel tanks. This report describes the results of a feasibility study of using gamma ray attenuation as the basis for measuring fuel quantity in the tanks. Studies with a weak Am-241 59.5-keV radiation source indicate that it is possible to continuously monitor the fuel quantity in the tanks to an accuracy of better than 1 percent. These measurements also indicate that there are easily measurable differences in the physical properties and resultant attenuation characteristics of JP-4, JP-5, and Jet A fuels. The experimental results, along with a suggested source-detector geometrical configuration are described.

Signh, J. J.↗

Hydraulic Calibrator for Strain-Gauge Balances

Instrument for calibrating strain-gauge balances uses hydraulic actuators and load cells. Eliminates effects of nonparallelism, nonperpendicularity, and changes of cable directions upon vector sums of applied forces. Errors due to cable stretching, pulley friction, and weight inaccuracy also eliminated. New instrument rugged and transportable. Set up quickly. Developed to apply known loads to wind-tunnel models with encapsulated strain-gauge balances, also adapted for use in calibrating dynamometers, load sensors on machinery and laboratory instruments.

Skelly, Kenneth↗

Calibrating an altimeter - How many tide gauges is enough?

The dominant contributor to the random error of an altimetric satellite system is the long wavelength uncertainty in the orbital radius. It is shown that calibration by a comparatively modest tide gauge system can drastically reduce the overall error in global estimates of large-scale oceanic variability. The procedure used is a form of optimal estimation. Absolute (time average) altimetric calibration is much more difficult because it requires absolute calibration of the tide gauge positions (in three dimensions) but the error reduction process would be the same.

Wunsch, Carl↗

Results of APL rain gauge network measurements in mid-Atlantic coast region and comparisons of distributions with CCIR models

In this effort are described cumulative rain rate distributions for a network of nine tipping bucket rain gauge systems located in the mid-Atlantic coast region in the vicinity of the NASA Wallops Flight Facility, Wallops Island, Virginia. The rain gauges are situated within a gridded region of dimensions of 47 km east-west by 70 km north-south. Distributions are presented for the individual site measurements and the network average for the year period June 1, 1986 through May 31, 1987. A previous six year average distribution derived from measurements at one of the site locations is also presented. Comparisons are given of the network average, the CCIR (International Radio Consultative Committee) climatic zone, and the CCIR functional model distributions, the latter of which approximates a log normal at the lower rain rate and a gamma function at the higher rates.

Goldhirsh, Julius↗

Shape Gauge Measures Surfaces

Tedious measurements and calculations performed quickly and accurately. Optical/mechanical/electronic system acts as shape gauge by taking measurements of machine-tool motions or complicated contours of objects, then processing measurement data into maps or profiles indicative of shapes. Transducers of shape gauge mechanical/electronic or optomechanical/electronic components that move along path on surface and measure roundness, perpendicular deviation, or slope of surface. Because of ease and speed, many intersecting profiles measured on surface.

Veale, Ralph C.↗

Program Calibrates Strain Gauges

Program dramatically reduces personnel and time requirements for acceptance tests of hardware. Data-acquisition system reads output from Wheatstone full-bridge strain-gauge circuit and calculates strain by use of shunt calibration technique. Program nearly instantaneously tabulates and plots strain data against load-cell outputs. Modified to acquire strain data for other specimens wherever full-bridge strain-gauge circuits used. Written in HP BASIC.

Okazaki, Gary D.↗

Tank gauging apparatus and method

An apparatus for gauging the amount of liquid in a container of liquid and gas under low or zero gravity net conditions includes an accumulator and appropriate connector apparatus for communicating gas between the accumulator and the container. In one form of the invention, gas is removed from the container and compressed into the accumulator. The pressure and temperature of the fluid in the container is measured before and after removal of the gas; the pressure and temperature of the gas in the accumulator is measured before and after compression of the gas into the accumulator from the container. These pressure and temperature measurements are used to determine the volume of gas in the container, whereby the volume of the liquid in the container can be determined from the difference between the known volume of the container and the volume of gas in the container. Gas from the accumulator may be communicated into the container in a similar process as a verification of the gauging of the liquid volume, or as an independent process for determining the volume of liquid in the container.

Morris, Brian G.↗

Tank gauging apparatus and method

Apparatus for gauging the amount of liquid in a container of liquid and gas under flow or zero gravity net conditions includes an accumulator and appropriate connector apparatus for communicating gas between the accumulator and the container. In one form of the invention, gas is removed from the container and compressed into the accumulator. The pressure and temperature of the fluid in the container is measured before and after removal of the gas; the pressure and temperature of gas in the accumulator is measured before and after compression of the gas into the accumulator from the container. These pressure and temperature measurements are used in determining the volume of gas in the container, whereby the volume of liquid in the container can be determined from the difference between the known volume of the container and the volume of gas in the container. Gas from the accumulator may be communicated into the container in a similar process as a verification of the gauging of the liquid volume, or as an independent process for determining the volume of liquid in the container.

Morris, Brian G.↗

Calibrator tests of heat flux gauges mounted in SSME blades

Measurements of heat flux to space shuttle main engine (SSME) turbine blade surfaces are being made in the Lewis heat flux calibration facility. Surface heat flux information is obtained from transient temperature measurements taken at points within the gauge. A 100-kW Vortek arc lamp is used as a source of thermal radiant energy. Thermoplugs, with diameters of about 0.190 cm and lengths varying from about 0.190 to 0.320 cm, are being investigated. The thermoplug is surrounded on all surfaces except the active surface by a pocket of air located in the circular annulus and under the back cover. Since the thermoplug is insulated, it is assumed that heat is conducted in a one-dimensional manner from the hot active surface to the cooler back side of the thermoplug. It is concluded that the miniature plug-type gauge concept is feasible for measurement of blade surface heat flux. It is suggested that it is important to measure heat flux near the hub on the suction surface and at the throat on SSME blades rotating in engines because stress and heat transfer coefficients are high in this region.

Liebert, Curt H.↗

Global-scale sea surface variability from combined altimetric and tide gauge measurements

By correcting Geosat altimetric data for a set of line frequencies, and then doing a heavy average in space and time, a set of global maps of sea surface variability is produced over time intervals ranging from three months to two years. These maps are demonstrated to be consistent with the global network of tide gauges and sets of maps incorporating those data into the altimetric estimates are also produced. Tide gauge records too fragmentary for computation of a two-year mean are employed by time-differencing them. An estimate of the global difference of sea level change over one year, on very large space scales, shows the effects of the 1987 El Nino. The spherical harmonic coefficients employed in the computations are then used to estimate the full three-dimensional frequency/wavenumber spectrum of surface circulation variability.

Wunsch, Carl↗

Orthogonal stack of global tide gauge sea level data

Yearly and monthly tide gauge sea level data from around the globe are fitted to numerically generated equilibrium tidal data to search for the 18.6 year lunar tide and 14 month pole tide. Both tides are clearly evident in the results, and their amplitudes and phases are found to be consistent with a global equilibrium response. Global, monthly sea level data from outside the Baltic sea and Gulf of Bothnia are fitted to global atmospheric pressure data to study the response of the ocean to pressure fluctuations. The response is found to be inverted barometer at periods greater than two months. Global averages of tide gauge data, after correcting for the effects of post glacial rebound on individual station records, reveal an increase in sea level over the last 80 years of between 1.1 mm/yr and 1.9 mm/yr.

Trupin, A.↗

Strain Gauges Mounted To Retain Calibration

Silicon-based semiconductor strain gauges mounted in such way they retain original calibration for several years instead of few months. Improvement effected by bonding gauges to ceramic substrates with glasses instead of epoxies as adhesives.

Butler, Barry L.↗

Measuring Fluctuating Pressures With Recessed Gauges

Report discusses use of pressure gauges mounted in recesses in interior wall of model scramjet engine. Consists of brief memorandum plus excerpts from NASA Technical Paper 3189, "Unsteady Pressure Loads In A Generic High-Speed Engine Model." Focuses mainly on factors affecting accuracy of gauge readings.

Parrott, Tony L.↗

On lattice chiral gauge theories

The Smit-Swift-Aoki formulation of a lattice chiral gauge theory is presented. In this formulation the Wilson and other non invariant terms in the action are made gauge invariant by the coupling with a nonlinear auxilary scalar field, omega. It is shown that omega decouples from the physical states only if appropriate parameters are tuned so as to satisfy a set of BRST identities. In addition, explicit ghost fields are necessary to ensure decoupling. These theories can give rise to the correct continuum limit. Similar considerations apply to schemes with mirror fermions. Simpler cases with a global chiral symmetry are discussed and it is shown that the theory becomes free at decoupling. Recent numerical simulations agree with those considerations.

Maiani, L.↗

Development of a skin friction gauge for use in an impulse facility

Tests of a prototype skin friction gauge at Mach 3.2 in a small free piston shock tunnel demonstrate the effectiveness of the design concept and the calibration against theoretical skin friction values in a simple flow. The gauge has a rise time of about 20 microsec, sufficiently short for most shock tunnel applications and approaching the rise times needed for expansion tube applications.

Kelly, G. M.↗

The Application of High-temperature Strain Gauges to the Measurements of Vibratory Stresses in Gas-turbine Buckets

The feasibility of measuring the vibration in the buckets of a gas turbine under service conditions of speed and temperature was determined by use of a high temperature wire strain gauge cemented to a modified supercharger turbine bucket. A high-temperature wire strain gauge and the auxiliary mechanical and electrical equipment developed for the investigation are described.

Kemp, R H↗