Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Experimental demonstration of direct L-shell x-ray fluorescence imaging of gold nanoparticles using a benchtop x-ray source

Purpose: To develop a proof-of-principle L-shell x-ray fluorescence (XRF) imaging system that locates and quantifies sparse concentrations of gold nanoparticles (GNPs) using a benchtop polychromatic x-ray source and a silicon (Si)-PIN diode x-ray detector system.Methods: 12-mm-diameter water-filled cylindrical tubes with GNP concentrations of 20, 10, 5, 0.5, 0.05, 0.005, and 0 mg/cm{sup 3} served as calibration phantoms. An imaging phantom was created using the same cylindrical tube but filled with tissue-equivalent gel containing structures mimicking a GNP-loaded blood vessel and approximately 1 cm{sup 3} tumor. Phantoms were irradiated by a 3-mm-diameter pencil-beam of 62 kVp x-rays filtered by 1 mm aluminum. Fluorescence/scatter photons from phantoms were detected at 90° with respect to the beam direction using a Si-PIN detector placed behind a 2.5-mm-diameter lead collimator. The imaging phantom was translated horizontally and vertically in 0.3-mm steps to image a 6 mm × 15 mm region of interest (ROI). For each phantom, the net L-shell XRF signal from GNPs was extracted from background, and then corrected for detection efficiency and in-phantom attenuation using a fluorescence-to-scatter normalization algorithm.Results: XRF measurements with calibration phantoms provided a calibration curve showing a linear relationship between corrected XRF signal and GNP mass per imaged voxel. Using the calibration curve, the detection limit (at the 95% confidence level) of the current experimental setup was estimated to be a GNP mass of 0.35 μg per imaged voxel (1.73 × 10{sup −2} cm{sup 3}). A 2D XRF map of the ROI was also successfully generated, reasonably matching the known spatial distribution as well as showing the local variation of GNP concentrations.Conclusions: L-shell XRF imaging can be a highly sensitive tool that has the capability of simultaneously imaging the spatial distribution and determining the local concentration of GNPs presented on the order of parts-per-million level within subcentimeter-sized ex vivo samples and superficial tumors during preclinical animal studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray fluorescence analysis of Ge{sub 1–x}Se{sub x}, As{sub 1–x}Se{sub x}, and Ge{sub 1–x–y}As{sub y}Se{sub x} glasses using electronic excitation

X-ray fluorescence analysis with fluorescence excitation by an electron beam with an energy of 30 kV is applied to determine the germanium, arsenic, and selenium contents in Ge{sub 1–x}Se{sub x}, As{sub 1–x}Se{sub x}, and Ge{sub 1–x–y}As{sub y}Se{sub x} glassy alloys. Using calibration dependences, the quantitative composition of the glasses is determined with an accuracy of ±0.0002 for parameters x and y in a surface layer ∼0.1 µm deep.

36 MATERIALS SCIENCE↗

A Fluorescence Spectrum Analyzer Based on a Fiber-Optic Y-Circulator

We consider a method of probe analysis employing fiber-optic a composite Y-circulator design for the implementation of laser-induced fluorescence (LIF) spectroscopy diagnostics. The proposed principle of the LIF analyzer is based on spatially separated directed optical beams of excitation and fluorescence radiations. Conditions of the effective Y-circulator operation as a passive fiber-optic switch are determined. Experimental investigation of the switched radiation losses is performed. An example of using the proposed analyzer for LIF diagnostics of biological media is presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis

Rapidly-frozen hydrated (cryopreserved) specimens combined with cryo-scanning x-ray fluorescence microscopy provide an ideal approach for investigating elemental distributions in biological cells and tissues. However, because cryopreservation does not deactivate potentially infectious agents associated with Risk Group 2 biological materials, one must be concerned with contamination of expensive and complicated cryogenic x-ray microscopes when working with such materials. We employed ultraviolet germicidal irradiation to decontaminate previously cryopreserved cells under liquid nitrogen, and then investigated its effects on elemental distributions under both frozen hydrated and freeze dried states with x-ray fluorescence microscopy. We show that the contents and distributions of most biologically important elements remain nearly unchanged when compared with non-ultraviolet-irradiated counterparts, even after multiple cycles of ultraviolet germicidal irradiation and cryogenic x-ray imaging. This provides a potential pathway for rendering Risk Group 2 biological materials safe for handling in multiuser cryogenic x-ray microscopes without affecting the fidelity of the results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two Photon Absorption Laser Induced Fluorescence for Neutral Hydrogen Profile Measurements

The magnitude and spatial dependence of neutral density in magnetic confinement fusion experiments is a key physical parameter, particularly in the plasma edge. Modeling codes require precise measurements of the neutral density to calculate charge-exchange power losses and drag forces on rotating plasmas. However, direct measurements of the neutral density are problematic. In this work, we proposed to construct a laser-based diagnostic capable of providing spatially resolved measurements of the neutral density in the edge of plasma in the DIII-D tokamak. The diagnostic concept is based on two-photon absorption laser induced fluorescence (TALIF). By injecting two beams of 205 nm light (co or counter propagating), ground state hydrogen (or deuterium or tritium) can be excited from the n = 1 level to the n = 3 level at the location where the two beams intersect. Individually, the beams experience no absorption, and therefore have no difficulty penetrating even dense plasmas. After excitation, a fraction of the hydrogen atoms decay from the n = 3 level to the n = 2 level and emit photons at 656 nm (the H α line). Calculations based on the results of previous TALIF experiments in magnetic fusion devices indicated that a laser pulse energy of approximately 3 mJ delivered in 5 ns would provide sufficient signal-to-noise for detection of the fluorescence. In collaboration with the DIII-D engineering staff and experts in plasma edge diagnostics for DIII-D from Oak Ridge National Laboratory (ORNL), WVU researchers designed a TALIF system capable of providing spatially resolved measurements of neutral deuterium densities in the DIII-D edge plasma. The laser systems were specified, purchased, and assembled at WVU. The TALIF system was tested on a low-power hydrogen discharge at WVU and the plan was to move the instrument to DIII-D for installation in collaboration with ORNL researchers. After budget cuts at DIII-D, the DIII-D facility declined to support installation on their tokamak. Instead, after a no-cost extension, the apparatus was moved to the University of Washington-Seattle and successfully tested on the HIT-SI3 spheromak experiment. As a result of this project, TALIF measurements of the absolutely calibrated neutral density hydrogen and deuterium were obtained in a helicon source and in a spheromak, designs were developed for installation of a TALIF system on a tokamak, and a new, xenon-based calibration scheme was proposed and demonstrated. The xenon-calibration scheme eliminates significant problems that were identified with the standard krypton calibration scheme.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Multi-Scale X-ray Fluorescence Tomography for Examination of Nanocomposite-Treated Biological Samples

Research in cancer nanotechnology is entering its third decade, and the need to study interactions between nanomaterials and cells remains urgent. Heterogeneity of nanoparticle uptake by different cells and subcellular compartments represent the greatest obstacles to a full understanding of the entire spectrum of nanomaterials’ effects. In this work, we used flow cytometry to evaluate changes in cell cycle associated with non-targeted nanocomposite uptake by individual cells and cell populations. Analogous single cell and cell population changes in nanocomposite uptake were explored by X-ray fluorescence microscopy (XFM). Very few nanoparticles are visible by optical imaging without labeling, but labeling increases nanoparticle complexity and the risk of modified cellular uptake. XFM can be used to evaluate heterogeneity of nanocomposite uptake by directly imaging the metal atoms present in the metal-oxide nanocomposites under investigation. While XFM mapping has been performed iteratively in 2D with the same sample at different resolutions, this study is the first example of serial tomographic imaging at two different resolutions. A cluster of cells exposed to non-targeted nanocomposites was imaged with a micron-sized beam in 3D. Next, the sample was sectioned for immunohistochemistry as well as a high resolution “zoomed in” X-ray fluorescence (XRF) tomography with 80 nm beam spot size. Multiscale XRF tomography will revolutionize our ability to explore cell-to-cell differences in nanomaterial uptake.

60 APPLIED LIFE SCIENCES↗

New Homogeneous Standards by Atomic Layer Deposition for Synchrotron X-ray Fluorescence and Absorption Spectroscopies.

Quantification of synchrotron XRF analyses is typically done through comparisons with measurements on the NIST SRM 1832/1833 thin film standards. Unfortunately, these standards are inhomogeneous on small scales at the tens of percent level. We are synthesizing new homogeneous multilayer standards using the Atomic Layer Deposition technique and characterizing them using multiple analytical methods, including ellipsometry, Rutherford Back Scattering at Evans Analytical, Synchrotron X-ray Fluorescence (SXRF) at Advanced Photon Source (APS) Beamline 13-ID, Synchrotron X-ray Absorption Spectroscopy (XAS) at Advanced Light Source (ALS) Beamlines 11.0.2 and 5.3.2.1 and by electron microscopy techniques. Our motivation for developing much-needed cross-calibration of synchrotron techniques is borne from coordinated analyses of particles captured in the aerogel of the NASA Stardust Interstellar Dust Collector (SIDC). The Stardust Interstellar Dust Preliminary Examination (ISPE) team have characterized three sub-nanogram, {approx}1{micro}m-sized fragments considered as candidates to be the first contemporary interstellar dust ever collected, based on their chemistries and trajectories. The candidates were analyzed in small wedges of aerogel in which they were extracted from the larger collector, using high sensitivity, high spatial resolution >3 keV synchrotron x-ray fluorescence spectroscopy (SXRF) and <2 keV synchrotron x-ray transmission microscopy (STXM) during Stardust ISPE. The ISPE synchrotron techniques have complementary capabilities. Hard X-ray SXRF is sensitive to sub-fg mass of elements Z {ge} 20 (calcium) and has a spatial resolution as low as 90nm. X-ray Diffraction data were collected simultaneously with SXRF data. Soft X-ray STXM at ALS beamline 11.0.2 can detect fg-mass of most elements, including cosmochemically important oxygen, magnesium, aluminum and silicon, which are invisible to SXRF in this application. ALS beamline 11.0.2 has spatial resolution better than 25 nm. Limiting factors for Stardust STXM analyses were self-imposed limits of photon dose due to radiation damage concerns, and significant attenuation of <1500 eV X-rays by {approx}80{micro}m thick, {approx}25 mg/cm{sup 3} density silica aerogel capture medium. In practice, the ISPE team characterized the major, light elements using STXM (O, Mg, Al, Si) and the heavier minor and trace elements using SXRF. The two data sets overlapped only with minor Fe and Ni ({approx}1% mass abundance), providing few quantitative cross-checks. New improved standards for cross calibration are essential for consortium-based analyses of Stardust interstellar and cometary particles, IDPs. Indeed, they have far reaching application across the whole synchrotron-based analytical community. We have synthesized three ALD multilayers simultaneously on silicon nitride membranes and silicon and characterized them using RBS (on Si), XRF (on Si{sub 3}N{sub 4}) and STXM/XAS (holey Si{sub 3}N{sub 4}). The systems we have started to work with are Al-Zn-Fe and Y-Mg-Er. We have found these ALD multi-layers to be uniform at {micro}m- to nm scales, and have found excellent consistency between four analytical techniques so far. The ALD films can also be used as a standard for e-beam instruments, eg., TEM EELS or EDX. After some early issues with the consistency of coatings to the back-side of the membrane windows, we are confident to be able to show multi-analytical agreement to within 10%. As the precision improves, we can use the new standards to verify or improve the tabulated cross-sections.

43 PARTICLE ACCELERATORS↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polymer Size–Catalytic Activity Relationships in Solution by Fluorescence Correlation Spectroscopy

Measuring the catalytic activity of specific sizes of polymers with active catalysts in solution is typically challenging, due to limited instrument detection sensitivity and/or dynamic range. Here, a fluorescence correlation spectroscopy (FCS) method is developed to determine the catalytic activity of living polymers of a specific apparent size in solution. Deviation from a single-component FCS data fitting, as assessed by χ2, is also introduced and developed as a “speciation index”—a method to evaluate and track changes in the relative amount of distinct polymer sizes with reaction progress. These methods are enabled by incorporating a selectively reactive fluorescent monomer into growing polydicyclopentadiene or polynorbornene during ring-opening metathesis polymerization (ROMP). Compared to polynorbornene, data showed that catalysts in aggregates of polyDCPD retained higher activity for longer—outcomes not directly inferable from simple diffusional-access predictions. Here, the ability to assign catalytic activity to polymers of specific sizes, and then to determine how this activity evolves with reaction progress, support long-term goals in the development and measurement of nano-objects that possess size-dependent catalytic activity.

Active catalyst↗

Laser-Induced Recoverable Fluorescence Quenching of Perovskite Films at a Microscopic Grain Scale

Understanding the fundamental properties of metal-halide perovskite materials is driving the development of novel optoelectronic applications. Here, in this paper, we report the observation of a recoverable laser-induced fluorescence quenching phenomenon in perovskite films with a microscopic grain-scale restriction, accompanied by spectral variations. This fluorescence quenching depends on the laser intensity and the dwell time under Auger recombination dominated conditions. These features indicate that the perovskite lattice deformation may take the main responsibility for the transient and show a new aspect to understand halide perovskite photo-stability. We further modulate this phenomenon by adjusting the charge carrier recombination and extraction, revealing that efficient carrier transfer can improve the bleaching resistance of perovskite grains. Our results provide future opportunities to attain high-performance devices by tuning the perovskite lattice disorder and harvesting the energetic carriers.

36 MATERIALS SCIENCE↗

Computational modeling of curcumin-based fluorescent probe molecules

In recent years, a series of curcumin analogs have been designed as fluorescent probes for detecting and imaging Aβ peptide aggregates and reactive oxygen species (ROS) in Alzheimer’s disease (AD) brains. In order to gain a better understanding of the photophysical properties of these probe molecules, a systematical computational investigation was performed using the time-dependent density functional theory (TDDFT) calculations. Computed absorption and emission wavelengths well reproduced the spectral shifts among the curcumin analogs. In particular, for a recently proposed pair of probe molecules, CRANAD-5 and CRANAD-61, for sensing ROS in preclinical studies of AD brains, their emission wavelength difference was found to arise from a delocalization of the lowest unoccupied molecular orbital of CRANAD-61 from the curcuminoid backbone to the oxalate moiety. Altogether, this study reaffirms the value of employing TDDFT calculations to assist the design of new curcumin-based fluorescence probes for AD research.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Improving the Lubricity of Extended Reach Well Drilling Equipment Using Non-Fluorescent Extreme Pressure Cationic Lubricants

In this study, non-fluorescent cationic extreme pressure lubricant JDLUB-1 was prepared to improve the lubricity for extended reach well drilling. The lubricant was mainly composed of synthetic base oil, oil-soluble and spherical nano-silica, sulfur-phosphorus-molybdenum anti-friction and anti-extreme pressure additives. The mixture was emulsified with primary emulsifier cycloalkane group condensed fatty amines and a fatty alcohol polyoxyethylene ether co-emulsifier. The fluorescence level did not exceed 4, satisfying the standard requirements. The properties including extreme pressure lubrication, temperature resistance and compatibility with conventional drilling fluid additives were evaluated. The results indicated that the extreme pressure lubricity coefficient could reach 0.0283 after addition of JDLUB-1. Meanwhile, the product was stable at high temperature of 130 °C, and compatible with common additives. The lubricity mechanism of JDLUB-1 was investigated by measuring the zeta potential, particle size distribution, adsorption, and anti-wear evaluation at extreme pressure. The results indicated that the positively charged lubricant oil droplets could be actively adsorbed onto the surface of N80 steel casing coupon. An adsorption film composed of oil soluble and spherical nano-silica and sulfur-phosphorus-molybdenum compounds was formed with a low melting point and low shear strength. During friction, the formation of molybdenum disulfide film leads to repair of the metal surface and formation of a stable sliding friction between the drill string and the wellbore with a low friction coefficient. The JDLUB-1 lubricant was successfully applied in several high-angle deviated wells and extended reach wells in Jidong oilfield (China). The results demonstrated that JDLUB-1 could effectively reduce torque and drag and show potential field application in the future.

36 MATERIALS SCIENCE↗

Determination of Cerium (IV) Using Rhodamine 6G Fluorescence Quenching

The interaction between rhodamine 6G (Rh6G) and cerium sulfate was studied by the fluorescence quenching method. In a sulfuric acid medium, the interaction of Ce(IV) with Rh6G results in Rh6G fluorescence quenching. The maximum excitation wavelength (λ{sub ex}) and the maximum emission wavelength (λ{sub em}) are 530 nm and 555 nm, respectively. A good linearity between the relative fl uorescence intensity (ΔF) and Ce(IV) was observed in the range ~0.12–1.08 μg/mL. The detection limit was 1.4 × 10{sup –3} μg/mL. The optimum reaction conditions, influencing factors, and effect of coexisting substances were investigated in the experiment. We found that the concentration of Rh6G was 3.2 × 10{sup –6} mol/L, and the fl uorescence intensity was maximum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence and Raman Spectroscopy of Doped Nanodiamonds

Raman and fluorescence spectroscopic techniques were used to study doped nanodiamonds synthesized at high pressure and high temperature (HPHT technique) and by chemical vapor deposition from the gas phase (CVD technique). For the CVD diamonds, a hundred-fold increase in fluorescence intensity of the silicon-vacancy centers normalized to the volume of the probe material was observed with an increase in synthesized diamond particle diameter from 150 to 300 nm. Graphitization temperature upon heating in the air significantly lower than for detonation nanodiamonds was found for the boron-doped HPHT nanodiamonds.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Remote Measurement of Variable Fluorescence Parameters of Plant Objects

An apparatus that measures variable fluorescence parameters accepted in PAM-fluorometry at a distance up to 0.6 m from the object and uses LED fluorescence excitation and a photodetector aperture of 25 mm was designed. Its operability was demonstrated using plants sealed hermetically in a container at this distance as examples. The usefulness of the method and apparatus in other instances was justified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and Photophysical Study of New Green Fluorescent TPA Based Poly(azomethine)s

A series of poly(azomethine)s (PAMs) were synthesized from N{sup 1}-(4-aminophenyl)-N{sup 1}-(4-phenoxyphenyl)benzene-1,4-diamine (DA) and various dialdehydes to investigate the influence of structure of polymer chain and triphenylamine-based phenoxy pendant group on the optoelectronic properties. The structural characterization of the resulting poly(azomethine)s was carried out by solubility test, gel permeation chromatography, viscosity measurement, fourier transform infrared (FTIR) spectral and CHN elemental analysis. The photophysical and electrochemical properties of the materials were scrutinized by UV–vis, photoluminescence, time correlation photon counting spectral analysis (TCSP) and cyclic voltammetry. The thermal stability of the poly(azomethine)s was assessed by differential scanning calorimetry and thermogravimetric analysis found to be stable upto 300 °C. These polymers exhibit moderate inherent viscosity range from 0.99 to 1.15 g dL{sup − 1} and appreciable organosolubility. The presence of triphenylamine and azomethine (CH = N) linkage in our synthesized materials rendered them fluorescent, emitting green light upon excitation at 375 nm with quantum efficiencies of 3.9–8.5%. The pendant phenoxy group at para-position in new poly(azomethine)s has also lowered the onset oxidation potentials and elevated the HOMO levels. Additionally, the presence of conjugation increases the fluorescence time of the excited state in conjugated polymers which was found in the range 9.22–11.17 ns, sufficient to be use in future optoelectronic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quaternary Ammonium Polyamidoamine Dendrimer Modified Quantum Dots as Fluorescent Probes for p-Fluorophenoxyacetic Acid Detection in Aqueous Solution

The wide use of pesticide p-fluorophenoxyacetic acid has caused the serious environmental contaminant. A novel fluorescent probe for sensitive detection of p-fluorophenoxyacetic acid in aqueous solutions based on 3.0G quaternary ammonium polyamidoamine (PAMAM) dendrimer modified quantum dots (QDs) (PAMAM@QDs) was reported. Through the solvent-evaporation method, quaternary ammonium PAMAM was employed to modify the QDs. Poloxamer 188 was used to improve the solubility and stability. The resultant PAMAM@QDs dispersed well in water. Fluorescence (FL) spectroscopic study showed that the FL intensity of the PAMAM@QDs was enhanced in the presence of p-fluorophenoxyacetic acid. Under optimal conditions, the enhanced FL intensity as a function of concentration matched very well in the range of 1 ~ 200 µg/mL of p-fluorophenoxyacetic acid, while the lower limits of detection were found to be 0.16 µg/mL. These results show that PAMAM@QDs is a promising luminescent probe for the detection of pesticides.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fluorescence Investigations on Interactions between 7,8-benzo-4-azidomethyl Coumarin and Ortho- and Para-phenylenediamines in Binary Solvent Mixtures of THF and Water

Fluorescence investigations on interactions between 7,8-benzo-4-azidomethyl coumarin (7BAMC) and quenchers ortho-phenylenediamine (OPD) and para-phenylenediamines (PPD) in binary solvent mixtures (THF + water) have been reported. UV-absorption study indicated a weak hydrophobic interaction between 7BAMC and the para isomer. NMR spectral studies indicated the presence of an interaction between 7BAMC and PPD. Magnitudes of the parameters associated with FRET, showed the presence of interactions between 7BAMC and PPD quencher is more predominant than OPD. Fluorescence quenching studies reveal the role of static and dynamic quenching pathways, depending upon Stern–Volmer constant, dielectric constant and dominant non-radiative processes. Binding equilibria analysis indicates a strong interaction between 7BAMC and PPD than OPD and formation of H-bonding. Based on the magnitudes of free energy, enthalpy change and entropy, bimolecular interaction process may be considered as spontaneous and hydrophobic.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗