Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

LANL Phase 3 Test Plan For Container Loading to Support the Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers

Fire testing of 3013 containers loaded with surrogate materials and water will be conducted to determine the response of 3013 containers stored in K-Area Complex (KAC) to a facility fire. Based on the proposal for the test configuration and loading, the objectives of the fire test are as follows: 1. “To increase understanding about the pressure and temperature conditions at which failure occurs; 2. To determine the allowable moisture for which failure will not occur under specified fire conditions, and 3. To increase understanding regarding the effects of salts on the pressurization, corrosion, and potential failure of the container.” Surrogate materials will be prepared at Los Alamos National Laboratory (LANL) and loaded in the 3013 containers. The containers will then be welded at LANL and shipped to Savannah River Site (SRS) for the installation of fittings and leak testing.

42 ENGINEERING↗

Rubble Fire Multi-Phase Model Development

This report presents multi-phase modeling approaches that are developed for simulating rubble fire scenarios similar to a large-scale rubble pool fire test at Sandia National Laboratories using composite materials and jet fuel. The rubble pool fire test burnt oddly shaped combustible solid objects submerged in liquid fuel. As an intermediate step toward a full scale rubble fire simulation, various model improvement tasks were performed. For modeling solid decomposition, a multi-step degradation model was used for canonical verification problems and the Chemical Percolation for Devolatilization (CPD) approach was implemented. Capabilities of Lagrangian particle approach has been extended such that a group of particles may represent a solid bulk. For gas-liquid interface, the volume of fluid (VOF) technique was implemented and relevant physics were added. The developed tools offer a potential for simulating three-phase (gas, liquid, and solid) combustion applications.

42 ENGINEERING↗

LANL Phase 3 Container Loading in Support of the Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers

The PCV/SCV/3013 Thermal Test Program is intended to determine the pressure response of packaged 3013 containers when exposed to a facility fire in the K-Area Complex (KAC) at the Savannah River Site. The fire tests support the KAC safety basis and must be bounding of the maximum pressure that would result from any 3013 container exposed to a KAC facility fire. The testing program has the following objectives: “To increase understanding of the pressure and temperature conditions at which failure occurs; To determine the allowable moisture for which failure will not occur under specified fire conditions, and; To increase understanding regarding the effects of salts on the pressurization, corrosion, and potential failure of the container.”

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Source Term of Accidents Involving Vehicle Crashes and Fuel Fires

This calculation is to be used when developing accident analysis scenarios involving fuel fires at the WSF. The objectives of the calculation are to determine (1) the Source Term from releases of TRU waste involved in impacts, impacts with fuel fire, and fuel fire with no impact; and (2) the plume sensible heat from various sizes of gasoline pool fires.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Source Term of Accidents Involving Aircraft Crashes and Fuel Fires

This calculation is to be used when developing accident analysis scenarios involving aircraft fuel fires at the Waste Storage Facility (WSF). The objectives of the calculation are to determine (1) the Source Term from releases of TRU waste involved in impacts, impacts with fuel fire, and fuel fire with no impact; and (2) the plume sensible heat from various sizes of gasoline pool fires.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fire-Induced Pressure Response and Failure Characterization of PCV/SCV/3013 Containers - Phase 1

This report discusses the test series performed at Sandia National Laboratories (SNL) to test the response of Primary Containment Vessels (PCVs) under a hypothetical fire scenario. The PCV is the innermost container in a 9975 shipping package (NRC, 2014). This test series was the first of three phases aiming to characterize the PCV/SCV/3013 system, and it will be referred to as Phase 1. The purpose of these tests was to characterize the response of the PCV wall when filled with a bounding payload and exposed to an ASTM-E1529 (ASTM, 2014) standard fire environment. In particular, the goal was to test a working hypothesis for these PCVs: that, during a scenario where the PCV is exposed to an ASTM-E1529 standard fire environment, the accumulated internal pressure (resulting from the expansion of gases and vaporization of moisture/plastics during heat exposure) relieves through the O-ring segment of the PCV before PCV wall failure (rupture). Bounding internal and external conditions were purposefully established for this Phase 1 testing in order to maximize pressurization in the container. Specifically, this Phase 1 test series is designed to determine the worst case thermal stress conditions by exposing five SRNS PCVs with identical payloads to the severe ASTM-E1529 fire conditions in five different configurations with increasing potential to result in a release of the internal contents (i.e. failure). All five tests were successfully executed, and the failure modes were characterized for each test. This report discusses the details of the five tests performed in this phase, their outcomes, and their implications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Los Alamos National Laboratory Floodplain Assessment for Fire Risk Mitigations at the Lower Slobbovia Testing Site in (TA-36)

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing to take fire pre-suppression actions at Los Alamos National Laboratory (LANL) Technical Area (TA) 36. Constructing a fire break and a fuel break surrounding the Lower Slobbovia explosives testing site in addition to the current vegetation mowing practices would establish a safety perimeter to help prevent fires from spreading away from the firing point. NNSA has prepared this floodplain assessment in accordance with 10 Code of Federal Regulations (CFR) Part 1022 Compliance with Floodplain and Wetland Environmental Review Requirements (10 CFR 1022), which was promulgated to implement DOE requirements under Executive Order 11988 Floodplain Management (EO 1977). A floodplain is defined in 10 CFR 1022 as “the lowlands adjoining inland and coastal waters and relatively flat areas and flood prone areas of offshore islands,” and a base floodplain as “the 100-year floodplain, that is, a floodplain with a 1.0 percent chance of flooding in any given year (CFR 2003).” This floodplain assessment evaluates potential impacts to floodplain values and functions from implementation of the proposed action, identifies alternatives to the Proposed Action, and allows for meaningful public comment.

54 ENVIRONMENTAL SCIENCES↗

Fuels Characterization for National Research Council Canada 2-m Pool Fire Test Series

This report provides a detailed analysis of the physical and chemical properties of three liquid hydrocarbon fuels: heptane, Bakken crude, and a diluted bitumen, that were subsequently tested in a series of 2-m pool fire experiments at Sandia National Laboratories for the National Research Council Canada. Properties such as relative density, vapor pressure (VPCR x ), composition, and heat of combustion were evaluated. The heptane analysis, with relative density = 0.69 (at 15°C), confirmed that the material tested was consistent with high-purity (>99%) n-heptane. The Bakken crude, with a relative density = 0.81 (at 15°C), exhibited a vapor pressure by VPCR 0.2 (37.8°C) in the range 120-157 kPa. The dilbit, with a relative density = 0.92 (at 15°C) exhibited a vapor pressure by VPCR 0.2 (37.8°C) in the range 85-98 kPa. Solids remaining in the test pans after the pool fires were also collected and weighed. No detectable solids were left after the heptane burns. In contrast, the crude oils left some brittle, black solid residue. On average, dilbit pool fires left about 40 more residue by mass than Bakken pool fires for equivalent mass of fuel feed.

01 COAL, LIGNITE, AND PEAT↗

Studying Rate of Fire Spread Using Landscape Statistics and FIRETEC

Wildfires are multi-system and multi-scale processes that are influenced by the land and atmosphere. Here, we study the influence of land, in terms of topography and vegetation, on uphill and downhill fire spread using data of the state of California as a testbed. The California landscape is first quantified by reclassifying its dominant vegetation types into grass, trees, and shrubs. Next, statistics of slope, vegetation height, and live fuel moisture percentage for each dominant vegetation type are gathered to create ensembles of idealized computational fluid dynamics (CFD) model simulations representative of the landscape. Rate of spread values for each CFD simulation are recorded to observe the differences in perturbing slope and fuel moisture for each vegetation type. We have found that all vegetation types prefer slopes of less than 30 degrees. Trees in the California data are 10 to 40 meters high, whereas shrub heights are less than 3 meters and grass heights are less than 1 meter. The live fuel moisture percentage of both trees and shrubs fluctuates around approximately 100% over one year (2019-2020). Using these parameters as inputs into the CFD model, fire spread rate is found to be fastest in the grass ensemble (maximum 12 m s -1 ), followed by shrubs (maximum 10 m s -1 ) and lastly by trees (maximum 7 m s -1 ). Increasing slope increases the spread rate of the uphill fire but the downhill spread decreases for slopes greater than 15 degrees. Increasing fuel moisture decreases the spread rate both up and down the hill. This study highlights the impacts that topography and vegetation have on fire spread.

54 ENVIRONMENTAL SCIENCES↗

Model Validation Database for Fires Involving Fuels at Liquefied Natural Gas Facilities

This document provides a description of the model evaluation protocol (MEP) database for fires involving liquefied natural gas (LNG) and processing fuels at LNG facilities. The purpose of the MEP is to provide procedures regarding the assessment of a model's suitability to predict thermal exclusion zones resulting from a fire. The database includes measurements from pool fire, jet fire, and fireball experiments which are provided in a spreadsheet. Users are to enter model results into the spreadsheet which automatically generates statistical performance measures and graphical comparisons with the experimental data. The intent of this document is to provide a description of the experiments and of the procedure required to carry out the validation portion of the MEP. In addition, the statistical performance measures, measurements for comparisons, and parameter variation are provided.

03 NATURAL GAS↗

Model Evaluation Protocol for Fire Models Involving Fuels at Liquefied Natural Gas Facilities.

This document provides a description of the model evaluation protocol (MEP) for pool fires, jet fires, and fireballs involving liquefied natural gas (LNG), refrigerant fluids, and byproducts at LNG facilities. The purpose of the MEP is to provide procedures regarding the assessment of a model's suitability to predict heat flux from fires. Three components, namely, a scientific assessment, model verification, and model validation comprise the MEP. The evaluation of a model satisfying these three components is to be documented in the form of a model evaluation report (MER). Discussion of models for the prediction of fire, detailed information on each of the three MEP components, the MEP procedure regarding new versions of previously approved models, and the format of the model evaluation report (MER) are provided.

03 NATURAL GAS↗

Hanford Site Post-Fire Vegetation Monitoring Report for Calendar Year 2025

The Hanford Site and the surrounding greater Columbia Basin is comprised of an expanse of shrub-steppe habitats that provides exceptional ecological value to plants and animals. The U.S. Department of Energy, Hanford Field Office (HFO)-managed portion of the Hanford Site, referred to from herein as Central Hanford, has experienced repeated wildfires resulting in profound, often adverse, effects on the landscape. This report summarizes these fires and fire monitoring efforts that occurred in calendar year (CY) 2025 and analyzes the post-fire vegetation recovery in restored areas to inform future post-fire response actions.

54 ENVIRONMENTAL SCIENCES↗

Model Validation Database for Fires Involving Fuels at Liquefied Natural Gas Facilities (Version 2)

This document provides a description of the model evaluation protocol (MEP) database for fires involving liquefied natural gas (LNG) and processing fuels at LNG facilities. The purpose of the MEP is to provide procedures regarding the assessment of a model’s suitability to predict thermal exclusion zones resulting from a fire. The database includes measurements from pool fire, jet fire, and fireball experiments which are provided in a spreadsheet. Users are to enter model results into the spreadsheet which automatically generates statistical performance measures and graphical comparisons with the experimental data. The intent of this document is to provide a description of the experiments and of the procedure required to carry out the validation portion of the MEP. In addition, the statistical performance measures, measurements for comparisons, and parameter variation are provided.

03 NATURAL GAS↗

Model Evaluation Protocol for Fire Models Involving Fuels at Liquefied Natural Gas Facilities (Version 2)

This document provides a description of the model evaluation protocol (MEP) for pool fires, jet fires, and fireballs involving liquefied natural gas (LNG) and processing fuels at LNG facilities. The purpose of the MEP is to provide procedures regarding the assessment of a model’s suitability to predict heat flux from fires. Three components, namely, a scientific assessment, model verification, and model validation comprise the MEP. The evaluation of a model satisfying these three components is to be documented in the form of a model evaluation report (MER). Discussion of models for the prediction of fire, detailed information on each of the three MEP components, the MEP procedure regarding new versions of previously approved models, and the format of the model evaluation report (MER) are provided.

03 NATURAL GAS↗

Impacts of TMDLs on coal-fired power plants.

The Clean Water Act (CWA) includes as one of its goals restoration and maintenance of the chemical, physical, and biological integrity of the Nation's waters. The CWA established various programs to accomplish that goal. Among the programs is a requirement for states to establish water quality standards that will allow protection of the designated uses assigned to each water body. Once those standards are set, state agencies must sample the water bodies to determine if water quality requirements are being met. For those water bodies that are not achieving the desired water quality, the state agencies are expected to develop total maximum daily loads (TMDLs) that outline the maximum amount of each pollutant that can be discharged to the water body and still maintain acceptable water quality. The total load is then allocated to the existing point and nonpoint sources, with some allocation held in reserve as a margin of safety. Many states have already developed and implemented TMDLs for individual water bodies or regional areas. New and revised TMDLs are anticipated, however, as federal and state regulators continue their examination of water quality across the United States and the need for new or revised standards. This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements its overall research effort by evaluating water issues that could impact power plants. One of the program missions of the DOE's NETL is to develop innovative environmental control technologies that will enable full use of the Nation's vast coal reserves, while at the same time allowing the current fleet of coal-fired power plants to comply with existing and emerging environmental regulations. Some of the parameters for which TMDLs are being developed are components in discharges from coal-fired power plants. If a state establishes a new or revised TMDL for one of these pollutants in a water body where a power plant is located, the next renewal of the power plant's National Pollution Discharge Elimination System (NPDES) permit is likely to include more restrictive limits. Power generators may need to modify existing operational and wastewater treatment technologies or employ new ones as TMDLs are revised or new ones are established. The extent to which coal-fired power plants may be impacted by revised and new TMDL development has not been well established. NETL asked Argonne to evaluate how current and potential future TMDLs might influence coal-fired power plant operations and discharges. This information can be used to inform future technology research funded by NETL. The scope of investigation was limited to several eastern U.S. river basins rather than providing a detailed national perspective.

01 COAL, LIGNITE, AND PEAT↗

The Co-Firing of Pine Biomass and Waste Coal in 100 and 600 MW Power Plants: A Sustainable Approach to Reduce GHG Emissions

Climate change is a global issue that has gained much attention recently. Co-firing biomass with coal/waste coal reduces the electricity sector’s GHG emissions sustainably. This study uses commercial software to model waste coal and biomass co-firing in 100 MW and 600 MW power plants. The objective is to assess the effects of fluid types (subcritical and supercritical), plant capacities (100 MW and 600 MW), boiler types (pulverized coal and circulating fluidized bed boilers), biomass and waste coal co-firing ratios (0:100, 20:80, 40:60, 60:40, 80:20, and 100:0), and carbon capture and storage efficiencies (0%, 90%, 95%, and 97%) on performance parameters such as net plant efficiency, heat rate, net plant CO2 and SO2, and particulate matter emissions. The feedstocks selected for this investigation include anthracite waste coal and loblolly pine biomass. As the biomass fraction increases from 0% to 100%, co-fired power plants net efficiency increases by 3–8%. Supercritical plants had a 6% higher net plant efficiency than the subcritical plants. The study found that the biomass’s high heating value decreased the fuel flow rate and reduced plant CO2 emissions by 10–16%. With 100% biomass power plant feed and 90% carbon capture and storage efficiency, CO2 emissions drop by 83% and SO2 and PM emissions drop to zero.

Bhoi, Prakashbhai R. (ORCID:0000000333104888)↗

Data accompanying the publication "Sensitivity of grass fires burning in marginal conditions to atmospheric turbulence" in the Journal of Geophysical Research-Atmospheres

Data accompanying Jonko, Yedinak, Conley, and Linn (2021): "Sensitivity of grass fires burning in marginal conditions to atmospheric turbulence", JGR-Atmospheres. LA-UR-21-24832. The following files were generated from simulations performed with Los Alamos National Laboratory coupled atmosphere-fire behavior model FIRETEC v1.3: -area_burned.csv contains the area burned per second in m^2 for 45 CORE simulations, 20 INIT simulations and 20 BOUND simulations (85 columns), and 600 seconds of simulation (600 rows). -fire_perimeter.csv containing the fire perimeters in m for 45 CORE simulations, 20 INIT simulations and 20 BOUND simulations (85 columns), and 600 seconds of simulation (600 rows). -consumption_per_second.csv containing consumption in kg/s for 45 CORE simulations, 20 INIT simulations and 20 BOUND simulations (85 columns), and 600 seconds of simulation (600 rows). -rate_of_spread.csv containing the distance of the fire front from the ignition line in m for 45 CORE simulations, 20 INIT simulations and 20 BOUND simulations (85 columns), and 600 seconds of simulation (600 rows). -CORE1_u_10m_300_sec.hdf, INIT3_u_10m_300_sec.hdf, and BOUND3_u_10m_300_sec.hdf contain u wind speeds at 10 m height for 300 seconds (3D: time, x, y) of simulation for simulations CORE1, INIT3, and BOUND3, respectively. -CORE.final.fuel.density.hdf contains final fuel densities in the surface layer of the model (3D: ensemble member, x, y) for all 45 CORE simulations. -CORE{1-45}_3D_u_120_sec.hdf: 45 files containing vertically and horizontally resolved u winds for 120 seconds of simulation (4D: time, x, y, z) for the 45 CORE ensemble members. For additional information about this data, please contact the corresponding author at ajonko@lanl.gov.

54 ENVIRONMENTAL SCIENCES↗

Method and apparatus for checking fire detectors

A fire detector checking method and device are disclosed for nondestructively verifying the operation of installed fire detectors of the type which operate on the principle of detecting the rate of temperature rise of the ambient air to sound an alarm and/or which sound an alarm when the temperature of the ambient air reaches a preset level. The fire alarm checker uses the principle of effecting a controlled simulated alarm condition to ascertain wheather or not the detector will respond. The checker comprises a hand-held instrument employing a controlled heat source, e.g., an electric lamp having a variable input, for heating at a controlled rate an enclosed mass of air in a first compartment, which air mass is then disposed about the fire detector to be checked. A second compartment of the device houses an electronic circuit to sense and adjust the temperature level and heating rate of the heat source.

Clawson, G. T.↗