Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FAST NEUTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Preliminary study of neutron absorption by concrete with boron carbide addition

Concrete has become a conventional material in construction of nuclear reactor due to its properties like safety and low cost. Boron carbide was added as additives in the concrete construction as it has a good neutron absorption property. The sample preparation for concrete was produced with different weight percent of boron carbide powder content. The neutron absorption rate of these samples was determined by using a fast neutron source of Americium-241/Be (Am-Be 241) and detection with a portable backscattering neutron detector. Concrete with 20 wt % of boron carbide shows the lowest count of neutron transmitted and this indicates the most neutrons have been absorbed by the concrete. Higher boron carbide content may affect the concrete strength and other properties.

07 ISOTOPE AND RADIATION SOURCES↗

Enrichment Determination of Uranium in Shielded Configurations

The determination of the enrichment of uranium is required in many safeguards and security applications. Typical methods of determining the enrichment rely on detecting the 186 keV gamma ray emitted by 235 U. In some applications, the uranium is surrounded by external shields, and removal of the shields is undesirable. In these situations, methods relying on the detection of the 186 keV gamma fail because the gamma ray is shielded easily. Oak Ridge National Laboratory (ORNL) has previously measured the enrichment of shielded uranium metal using active neutron interrogation. The method consists of measuring the time distribution of fast neutrons from induced fissions with large plastic scintillator detectors. To determine the enrichment, the measurements are compared to a calibration surface that is created from Monte Carlo simulations where the enrichment in the models is varied. In previous measurements, the geometry was always known. ORNL is extending this method to situations where the geometry and materials present are not known in advance. In the new method, the interrogating neutrons are both time and directionally tagged, and an array of small plastic scintillators measures the uncollided interrogating neutrons. Therefore, the attenuation through the item along many different paths is known. By applying image reconstruction techniques, an image of the item is created which shows the position-dependent attenuation. The image permits estimating the geometry and materials present, and these estimates are used as input for the Monte Carlo simulations. As before, simulations predict the time distribution of induced fission neutrons for different enrichments. Matching the measured time distribution to the closest prediction from the simulations provides an estimate of the enrichment. This presentation discusses the method and provides results from recent simulations that show the importance of knowing the geometry and materials from the imaging system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plastic neutron detectors.

This work demonstrated the feasibility and limitations of semiconducting {pi}-conjugated organic polymers for fast neutron detection via n-p elastic scattering. Charge collection in conjugated polymers in the family of substituted poly(p-phenylene vinylene)s (PPV) was evaluated using band-edge laser and proton beam ionization. These semiconducting materials can have high H/C ratio, wide bandgap, high resistivity and high dielectric strength, allowing high field operation with low leakage current and capacitance noise. The materials can also be solution cast, allowing possible low-cost radiation detector fabrication and scale-up. However, improvements in charge collection efficiency are necessary in order to achieve single particle detection with a reasonable sensitivity. The work examined processing variables, additives and environmental effects. Proton beam exposure was used to verify particle sensitivity and radiation hardness to a total exposure of approximately 1 MRAD. Conductivity exhibited sensitivity to temperature and humidity. The effects of molecular ordering were investigated in stretched films, and FTIR was used to quantify the order in films using the Hermans orientation function. The photoconductive response approximately doubled for stretch-aligned films with the stretch direction parallel to the electric field direction, when compared to as-cast films. The response was decreased when the stretch direction was orthogonal to the electric field. Stretch-aligned films also exhibited a significant sensitivity to the polarization of the laser excitation, whereas drop-cast films showed none, indicating improved mobility along the backbone, but poor {pi}-overlap in the orthogonal direction. Drop-cast composites of PPV with substituted fullerenes showed approximately a two order of magnitude increase in photoresponse, nearly independent of nanoparticle concentration. Interestingly, stretch-aligned composite films showed a substantial decrease in photoresponse with increasing stretch ratio. Other additives examined, including small molecules and cosolvents, did not cause any significant increase in photoresponse. Finally, we discovered an inverse-geometric particle track effect wherein increased track lengths created by tilting the detector off normal incidence resulted in decreased signal collection. This is interpreted as a trap-filling effect, leading to increased carrier mobility along the particle track direction. Estimated collection efficiency along the track direction was near 20 electrons/micron of track length, sufficient for particle counting in 50 micron thick films.

36 MATERIALS SCIENCE↗

Applications of neutron-absorbing structural amorphous metal (SAM) coatings for criticality safety controls of used fuel storage, transportation, and disposal - 14534

Used nuclear fuel contains fissionable materials ({sup 235}U, {sup 239}Pu, {sup 241}Pu, etc.). To prevent nuclear criticality in used fuel storage, transportation, and disposal, neutron-absorbing materials (or neutron poisons, such as borated stainless steel, Boral{sup TM}, Metamic{sup TM}, Ni-Gd, etc.) would have to be applied. Corrosion-resistant, iron-based structural-amorphous metals (SAMs) have been tested to determine their relative corrosion resistance. Many of these materials can be applied as coatings with advanced High Velocity Oxy-Fuel (HVOF) thermal-spray technology. SAM2X5, SAM1651, and other SAMs are amorphous-metal composite alloys that have been identified as having outstanding corrosion resistance. Because of its high boron content, SAM2X5 can be applied as the neutron-absorbing coatings to the metallic support structure for criticality-safety controls of used fuel in racks in wet storage pool and baskets inside the storage containers, the transportation cask, and eventually the disposal containers in repository disposal. Research and experiment conducted at Lawrence Livermore National Laboratory indicated that the high boron-containing SAM2X5 coating could be an effective criticality control material for used fuel management. The neutron irradiation experiments and the neutron transmission measurements conducted at McClellan Nuclear Radiation Center indicated that extensive fast neutron irradiation did not change the structure of the amorphous SAM2X5 melt-spun ribbons, and SAM2X5 exhibited effective neutron absorbing capability, similar to Boral{sup TM} and Metamic{sup TM}. (authors)

36 MATERIALS SCIENCE↗

Characterization of single crystal chemical vapor deposition diamond detectors for neutron spectrometry

Detectors made from artificial chemical vapor deposition single crystal diamond have shown great potential for fast neutron spectrometry. In this paper, we present the results of measurements made at the Physikalisch-Technische Bundesanstalt accelerator using neutron fields in the energy range from 7 MeV to 16 MeV. This study presents the first results of the characterization of the detector in this energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Baseline Postirradiation Examination of the FUTURIX-FTA Experiments

Postirradiation Examination (PIE) results from the baseline examination of the FUTURIX-FTA irradiation experiment are presented in this report. The FUTURIX-FTA irradiation was designed to study the fuel performance of candidate transmutation fuels. The FUTURIX-FTA experiment was conducted in the true fast neutron spectrum conditions of the Phénix sodium fast test reactor in France. FUTURIX-FTA contained several compositions that were also irradiated as part of the AFC-1 test in cadmium filtered positions in the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) that approximate the neutron spectrum of a fast reactor. This experiment was a joint collaboration between the Department of Energy (DOE) in the U.S. and the Commissariat á l'Energie Atomique et aux Energies Alternatives (CEA) in France. A joint agreement between DOE and CEA was established in 2004 to conduct an irradiation experiment of metallic and nitride fuels in the Phénix reactor at CEA. Both the FUTURIX-FTA tests and the AFC-1 tests were conducted for the DOE Advanced Fuels Campaign (AFC) that is part of Fuel Cycle Research & Development (FCRD) program. These programs seek to develop and demonstrate the technologies needed to transmute long-lived transuranic actinide isotopes contained in spent nuclear fuel via fast reactor technology. The long term goal of this work is to reduce the radiotoxicity of future high level waste repositories. Post-irradiation examination of irradiated fuels experiments provides data related to in reactor fuel performance and input into future fuel design choices. The compositions of the FUTURIX-FTA pins were designed to test if minor actinides could be incorporated into the fuel of a fast reactor without significantly changing fuel performance observed for previously well studied fuels. The fuel performance of metallic fuel in fast reactors has been well documented. Likewise the irradiation performance of nitride fuels in fast reactors has also been documented. However the existing database for nitride fuels is much smaller than the database for metal fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Subcritical Measurments Multiple HEU Metal Castings

Experiments with the standard annular highly enriched uranium (HEU) metal castings at the Y-12 National Security Complex were performed in which up to five castings ({approx}90 kg) were assembled in a tightly packed array with minimal spacing between castings. The fission chain multiplication process was initiated by a time-tagged {sup 252}Cf spontaneously fissioning neutron source or by time and directionally tagged neutrons from a small portable DT neutron generator. The prompt neutron time behavior was measured with plastic scintillation detectors sensitive to the fast neutron (>1 MeV) and gamma ray without distinction. These experiments were performed to provide data to benchmark methods for the calculation of the prompt neutron time behavior. Previous measurements with a single casting have been reported. This paper presents the experimental results for multiple castings.

36 MATERIALS SCIENCE↗

Design Studies for a Multiple Application Thermal Reactor for Irradiation Experiments (MATRIX)

The Advanced Test Reactor (ATR) is a high power density test reactor specializing in fuel and materials irradiation. For more than 45 years, the ATR has provided irradiations of materials and fuels testing along with radioisotope production. Should unforeseen circumstances lead to the decommissioning of ATR, the U.S. Government would be left without a large-scale materials irradiation capability to meet the needs of its nuclear energy and naval reactor missions. In anticipation of this possibility, work was performed under the Laboratory Directed Research and Development (LDRD) program to investigate test reactor concepts that could satisfy the current missions of the ATR along with an expanded set of secondary missions. A survey was conducted in order to catalogue the anticipated needs of potential customers. Then, concepts were evaluated to fill the role for this reactor, dubbed the Multi-Application Thermal Reactor Irradiation eXperiments (MATRIX). The baseline MATRIX design is expected to be capable of longer cycle lengths than ATR given a particular batch scheme. The volume of test space in In-Pile-Tubes (IPTs) is larger in MATRIX than in ATR with comparable magnitude of neutron flux. Furthermore, MATRIX has more locations of greater volume having high fast neutron flux than ATR. From the analyses performed in this work, it appears that the lead MATRIX design can be designed to meet the anticipated needs of the ATR replacement reactor. However, this design is quite immature, and therefore any requirements currently met must be re-evaluated as the design is developed further.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New developments for the determination of the response function for a BC501A compact neutron spectrometer for fusion diagnostics

The compact neutron spectrometer project was initiated to develop a device able to study fast neutrons produced by fusion reactions in a tokamak. The goal is to provide a fully characterized BC501A detector using a digital acquisition system developed by ENEA. The pulse height resolution and the response matrix of the detector are determined using experimental data acquired at the PTB facility. To achieve this goal, methods of data analysis involving entropy maximization and new software were developed. The methods are described and the current results for the pulse height resolution are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FISSION NEUTRON IRRADIATION EFFECT ON INTERLAMINAR SHEAR STRENGTH OF CYANATE ESTER RESIN GFRP AT RT AND 77 K

A glass fiber reinforced plastic (GFRP) with cyanate ester resin was fabricated and neutron irradiation tests up to 1x10{sup 22} n/m{sup 2} of fast neutron with over 0.1 MeV energy were carried out in fission reactor. The fabrication process of cyanate ester GFRP was established and a collaboration network to perform investigations on irradiation effect of superconducting magnet materials was constructed. Three kinds of samples were fabricated. The first was CTD403 GFRP made by NIFS, the second was (cyanate ester+epoxy) GFRP provided by Toshiba, and the last was CTD403 GFRP made by Toshiba. The irradiation was carried out at JRR-3 in Japan Atomic Energy Agency using Rabbit capsules.After the irradiation, short beam tests were conducted at room temperature and 77 K and interlaminar shear strength (ILSS) was evaluated. The irradiation of 1x10{sup 21} n/m{sup 2} increased ILSS a little but 1x10{sup 22} n/m{sup 2} irradiation decreased ILSS to around 50 MPa. These tendencies were observed in all three kinds of GFRPs.

36 MATERIALS SCIENCE↗

SU-E-T-594: Out-Of-Field Neutron and Gamma Dose Estimated Using TLD-600/700 Pairs in the Wobbling Proton Therapy System

Purpose: Secondary fast neutrons and gamma rays are mainly produced due to the interaction of the primary proton beam with the beam delivery nozzle. These secondary radiation dose to patients and radiation workers are unwanted. The purpose of this study is to estimate the neutron and gamma dose equivalent out of the treatment volume during the wobbling proton therapy system. Methods: Two types of thermoluminescent (TL) dosimeters, TLD-600 ({sup 6}LiF: Mg, Ti) and TLD-700 ({sup 7}LiF: Mg, Ti) were used in this study. They were calibrated in the standard neutron and gamma sources at National Standards Laboratory. Annealing procedure is 400°C for 1 hour, 100°C for 2 hours and spontaneously cooling down to the room temperature in a programmable oven. Two-peak method (a kind of glow curve analysis technique) was used to evaluate the TL response corresponding to the neutron and gamma dose. The TLD pairs were placed outside the treatment field at the neutron-gamma mixed field with 190-MeV proton beam produced by the wobbling system through the polyethylene plate phantom. The results of TLD measurement were compared to the Monte Carlo simulation. Results: The initial experiment results of calculated dose equivalents are 0.63, 0.38, 0.21 and 0.13 mSv per Gy outside the field at the distance of 50, 100, 150 and 200 cm. Conclusion: The TLD-600 and TLD-700 pairs are convenient to estimate neutron and gamma dosimetry during proton therapy. However, an accurate and suitable glow curve analysis technique is necessary. During the wobbling system proton therapy, our results showed that the neutron and gamma doses outside the treatment field are noticeable. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)

61 RADIATION PROTECTION AND DOSIMETRY↗

Laser annealing of neutron irradiated boron-10 isotope doped diamond

10B isotope doped p-type diamond epilayer grown by chemical vapor deposition on (110) oriented type IIa diamond single crystal substrate was subjected to neutron transmutation at a fluence of 2.4 9 1020 thermal and 2.4 9 1020 fast neutrons. After neutron irradiation, the epilayer and the diamond substrate were laser annealed using Nd YAG laser irradiation with wave length, 266 nm and energy, 150 mJ per pulse. The neutron irradiated diamond epilayer and the substrate were characterized before and after laser annealing using different techniques. The characterization techniques include optical microscopy, secondary ion mass spectrometry, X-ray diffraction, Raman, photoluminescence and Fourier Transform Infrared spectroscopy, and electrical sheet conductance measurement. The results indicate that the structure of the irradiation induced amorphous epilayer changes to disordered graphite upon laser annealing. The irradiated substrate retains the (110) crystalline structure with neutron irradiation induced defects.

36 MATERIALS SCIENCE↗

Microstructural evolution of Q12{sup TM} alloy irradiated in PWRs and comparison with other Zr base alloys - 2016-0061

Based on the M5{sup R}* alloy metallurgy, the Q12{sup TM} alloy (Zr-1Nb-0.5Sn-0.1Fe) was developed by AREVA NP for structural components, with ultra-low tin addition and slightly increased iron content. The behavior of this alloy was tested under irradiation in a pressurized water reactor (PWR) and has shown improvement in irradiation creep strength and similar free growth compared with M5. This paper provides results on dimensional stability and details the microstructural evolution of the Q12 alloy under neutron irradiation in PWRs. The Q12 microstructural evolution under irradiation was studied for fast neutron fluences up to 13 X 10{sup 25} n/m{sup 2} (E>1 MeV) with analytical transmission electron microscopy observations. We focused on radiation-enhanced needle-like particles, Laves phases, and the linear density of -component loops. These results are compared with other quaternary zirconium-niobium-tin-iron alloys and with M5. All these results allow a general discussion about microstructural evolution and behavior under irradiation of quaternary-type alloys compared to M5 alloy. This study, in agreement with previous works on Zr-1Nb and quaternary alloys, seems to show that increasing the iron content with the presence of niobium and tin will decrease the -component loop linear density and delay the growth breakaway. (authors)

36 MATERIALS SCIENCE↗

A revisitation of the ENEA TAPIRO Fast Source Reactor neutronic capabilities

This work is devoted to the analysis of the neutronic characterization of the ENEA-Casaccia center RSV TAPIRO fast neutrons source reactor performed during the 80's in the frame of a joint ENEA-SCK-CEN Mol collaboration. The Belgian scientist Albert Fabry, who was available to investigate a fast research reactor to perform a full characterization of the system neutron flux, led the TAPIRO experimental campaign. In particular, the paper is focused on the comparison between some 'recommended' Fabry experimental reaction rates traverses and nowadays MCNP Monte Carlo and ERANOS deterministic calculation results. It appears that the quality of the results depends on the penetration depth into the copper reflector. The influence of copper nuclear data are more evident in the ERANOS results. Massimo Salvatores has provided a great contribution to the interpretation of the TAPIRO neutronics: this humble work is dedicated to him.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analytical expressions for the gate utilization factors of passive multiplicity counters including signal build-up

In the realm of nuclear safeguards, passive neutron multiplicity counting using shift register pulse train analysis to nondestructively quantify Pu in product materials is a familiar and widely applied technique. The approach most commonly taken is to construct a neutron detector consisting of {sup 3}He filled cylindrical proportional counters embedded in a high density polyethylene moderator. Fast neutrons from the item enter the moderator and are quickly slowed down, on timescales of the order of 1-2 {micro}s, creating a thermal population which then persists typically for several 10's {micro}s and is sampled by the {sup 3}He detectors. Because the initial transient is of comparatively short duration it has been traditional to treat it as instantaneous and furthermore to approximate the subsequent capture time distribution as exponential in shape. With these approximations simple expressions for the various Gate Utilization Factors (GUFs) can be obtained. These factors represent the proportion of time correlated events i.e. Doubles and Triples signal present in the pulse train that is detected by the coincidence gate structure chosen (predelay and gate width settings of the multiplicity shift register). More complicated expressions can be derived by generalizing the capture time distribution to multiple time components or harmonics typically present in real systems. When it comes to applying passive neutron multiplicity methods to extremely intense (i.e. high emission rate and highly multiplying) neutron sources there is a drive to use detector types with very fast response characteristics in order to cope with the high rates. In addition to short pulse width, detectors with a short capture time profile are also desirable so that a short coincidence gate width can be set in order to reduce the chance or Accidental coincidence signal. In extreme cases, such as might be realized using boron loaded scintillators, the dieaway time may be so short that the build-up (thermalization transient) within the detector cannot be ignored. Another example where signal build-up might be observed is when a {sup 3}He based system is used to track the evolution of the time correlated signal created by a higher multiplying item within a reflective configuration such as the measurement of a spent fuel assembly. In this work we develop expressions for the GUFs which include signal build-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancing Neutron Beam Production with a Convoluted Moderator

We describe a new concept for a neutron moderating assembly resulting in the more efficient production of slow neutron beams. The Convoluted Moderator, a heterogeneous stack of interleaved moderating material and nearly transparent single-crystal spacers, is a directionally-enhanced neutron beam source, improving beam effectiveness over an angular range comparable to the range accepted by neutron beam lines and guides. We have demonstrated gains of 50% in slow neutron intensity for a given fast neutron production rate while simultaneously reducing the wavelength-dependent emission time dispersion by 25%, both coming from a geometric effect in which the neutron beam lines view a large surface area of moderating material in a relatively small volume. Additionally, we have confirmed a Bragg-enhancement effect arising from coherent scattering within the single-crystal spacers. We have not observed hypothesized refractive effects leading to additional gains at long wavelength. In addition to confirmation of the validity of the Convoluted Moderator concept, our measurements provide a series of benchmark experiments suitable for developing simulation and analysis techniques for practical optimization and eventual implementation at slow neutron source facilities.

Grooved moderator↗

INL Report: Multiphysics Modeling and Simulation of Deimos, an Advanced Reactor Experiment

When designing a novel reactor, nuclear experiments are essential to validate the predictive capability of modeling/simulation tools and to justify the investment of a full-scale prototype. Being able to accurately predict temperature reactivity coefficients is of high importance to reactor designers as it impacts the safety and performance of the system. Deimos is a proposed graphite-moderated, beryllium-reflected, high assay low-enriched uranium (HALEU) tri-structural isotropic (TRISO) fueled experiment for NCERC. Deimos is a valuable experiment for validating the predictive performance of modeling and simulation tools since it comprises a relatively thermal energy spectrum with 84% thermal neutrons causing fission, 15% epithermal neutrons causing fission, and 1% fast neutrons causing fission. Additionally, by electrically heating the experiment, reactivity can be validated at various temperatures. Deimos will serve as a testbed for future advanced reactor concepts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing and Characterization to Develop a Mechanistic Explanation for Unsaturated Drift of Fiber Optic Sensors during High-Dose Irradiation

The primary limitation for any optical fiber-based sensor for nuclear reactor applications is radiation-induced attenuation (RIA) of the transmitted and/or reflected signals. Based on several recent studies, RIA is tolerable for some fused silica optical fibers with the proper choice of sensing wavelength and fiber dopants. For extreme temperature applications (> 1000°C), sapphire optical fibers have been proposed; however, recent optical transmission measurements performed on bulk sapphire samples showed prohibitively large RIA. For some sensors, radiation-induced dimensional changes in the fiber materials can also cause significant drift. Moreover, the drift that was observed in numerous experiments performed in the High Flux Isotope Reactor (HFIR), the Advanced Test Reactor, the Massachusetts Institute of Technology Reactor, and other international facilities far exceeded what would be expected based on compaction of fused silica glass. Clearly, additional work is needed to better understand the origins of both RIA and radiation-induced drift in both silica and sapphire optical fiber-based sensors before these sensors can be reliably deployed for nuclear applications. This work evaluated the underlying mechanisms that may be responsible for RIA and drift in silica and sapphire materials. First, detailed characterization was performed on bulk fused silica glass samples that were previously irradiated to different neutron fluences at different temperatures to better understand the structural changes that drive radiation-induced drift in the absence of coating effects that are discussed later. Results show that the non-monotonic compaction that occurs with increasing neutron fluence continues up to fast neutron fluences approaching 10 22 n/cm 2 , which has important implications for physics-based models that may be used to compensate for the sensor drift. Initial Raman spectroscopy and synchrotron x-ray diffraction provide insights into the nature of the structural changes. Next, detailed characterizations were performed on silica fibers with various coatings that were subjected to several different thermal treatments. The hypothesis is that the coatings convert to carbon-rich materials that compact under irradiation, putting a large compressive strain on the fiber. Out-of-pile testing confirms that both polyimide and acrylate fiber coatings convert to glassy carbon (GC) materials when heated under inert conditions, and the degree of order (i.e., graphitization) increases with increasing temperature. The results provide increasingly strong evidence that the combination of polymeric coatings and inert (or vacuum) conditions render fiber optic sensors susceptible to significant radiation-induced drift that would not otherwise exist in uncoated fibers. Finally, transmission electron microscopy was performed on bulk sapphire samples that were irradiated to two neutron fluences at different temperatures to gain insights into the potential mechanisms driving the prohibitive RIA at higher neutron fluences and temperatures. Contrary to previous hypotheses, results show that scattering from radiation-induced voids cannot explain the observed RIA. Similarly, models for scattering losses from dislocation loops also do not agree with the experimental results. Instead, fitting to the experimental data shows that increased absorption from aluminum vacancy centers is the most likely explanation for the the prohibitively large RIA that was observed at high irradiation temperature and dose. In addition, the voids that formed in these single-crystal samples were found to align along the basal plane (a-axis) as opposed to that seen in previous observations of c-axis alignment in polycrystalline samples, which could have important implications for anisotropic swelling and other phenomena that could affect sensor performance at high neutron fluence.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗