Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Management System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Machine Learning-Assisted Stability Boundary Determination of Multiport Autonomous Reconfigurable Solar Power Plants

The multiport autonomous reconfigurable solar (MARS) power plant is a promising solution to integrate renewable resources and energy storage systems into the alternating current (ac) power grid and an high-voltage direct current (HVdc) link. In the MARS system, various input power sources are connected to the individual submodules (SMs) through direct current (dc)–dc converters. However, the presence of external power sources can result in unbalanced capacitor voltages of SMs, thereby violating stability constraints under multiple/diverse operating conditions. This article aims to address the gap by accurately determining the stability boundary of the MARS system. As such, a novel machine learning (ML)-assisted energy balancing control (EBC) criterion is proposed. Further, in conjunction with a refined EBC, this approach ensures balanced capacitor voltages across various types of SMs, significantly enhancing the overall system efficiency. The proposed EBC criterion effectively controls EBC activation and deactivation, achieving remarkable accuracy. Both power systems computer aided design (PSCAD)/electromagnetic transients including direct current (EMTDC) simulations and control hardware-in-the-loop (cHIL) tests are conducted to validate the feasibility and efficiency of the proposed method. By combining the EBC and ML-assisted EBC criterion, efficient energy management is achieved for systems featuring multiple input power sources, such as MARS. This approach enables the system to fully exploit its potential across an expanded operational range while upholding high-efficiency standards.

14 SOLAR ENERGY↗

Integrated Energy-Water Data for Cross-Sector Resilience

This white paper focuses on the “energy-for-water” domain, addressing the urgent need for integrated, empirical data to support regional management, benchmarking, and research on improving efficiency and developing technologies for water and wastewater management systems. The costs and energy required for the supply, treatment, and distribution of water and wastewater lack a standard data collection mechanism and centralized database or storage infrastructure, limiting data-driven decision-making across interdependent infrastructure systems.

42 ENGINEERING↗

Study on the application of NASA energy management techniques for control of a terrestrial solar water heating system

This paper addresses the potential for enhanced solar system performance through sophisticated control of the collector loop flow rate. Computer simulations utilizing the TRNSYS solar energy program were performed to study the relative effect on system performance of eight specific control algorithms. Six of these control algorithms are of the proportional type: two are concave exponentials, two are simple linear functions, and two are convex exponentials. These six functions are typical of what might be expected from future, more advanced, controllers. The other two algorithms are of the on/off type and are thus typical of existing control devices. Results of extensive computer simulations utilizing actual weather data indicate that proportional control does not significantly improve system performance. However, it is shown that thermal stratification in the liquid storage tank may significantly improve performance.

Swanson, T. D.↗

Federal Energy Management 101: Track 7, Session 1

Federal Energy Management 101: What are common building systems that use energy? This session will cover the basics of HVAC, Lighting, and Building Envelope and discuss how much energy each system tends to use within facilities - and how that changes across building types. Additionally, this session will cover identifying energy conservation measures (ECMs) and the process in which they are identified, funded, implemented, and savings are verified.

101↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

Developing Fuel Cell Electric Powertrain Architectures for Commercial Vehicles

Here, this article addresses the architecture development for a commercial vehicle fuel cell electric powertrain by establishing a clear multi-step formalized workflow that employs a unique technoeconomic solution for architecture selection. The power capability of the fuel cell, the energy capacity and chemistry of the electrical energy storage (battery), the DC-DC converter (including the input current rating and isolation resistance requirements), the traction drive solution, the on-board hydrogen storage solution, and the real-time power-split management of the fuel cell and the battery are all considered and developed in this effort. The methods were used to select architecture for Class 8 urban, regional, and line haul applications. When compared to traditional load-following power-split controllers, an energy management power-split controller can increase system energy efficiency by up to 19.5%. The energy-efficient power-split controller may increase the required battery capacity for an equivalent life by up to 2.6 times. The impact on the total cost of ownership (TCO) for a variety of financial cases demonstrates that high C-rate capable batteries have the potential to provide better TCO solutions over a six-year vehicle life than low C-rate capable batteries. To achieve TCO parity with the 600 A non-isolated DC-DC converter case, the specific choice of the fuel cell DC-DC converter to achieve a target power output based on current levels (from 500 A to 2400 A) shows that efficiency decreases and cost increases due to the higher current, requiring fuel cell prices to decrease by $50–$100/kW, $60–$110/kW, and $100–$220/kW for urban, regional, and line haul applications, respectively. Key recommendations for powertrain system architectures are provided, with specifics based on vehicle dynamics, mission and application characteristics, end customer use-case profile, critical powertrain component costs, and architecture selection cost function. This study rigorously demonstrates the interplay of the above parameters, with a focus on TCO, and provides application decision-makers with a mechanism and well-defined set of impact factors to consider as part of their architecture selection process.

25 ENERGY STORAGE↗

Space power subsystem automation technology

The technology issues involved in power subsystem automation and the reasonable objectives to be sought in such a program were discussed. The complexities, uncertainties, and alternatives of power subsystem automation, along with the advantages from both an economic and a technological perspective were considered. Whereas most spacecraft power subsystems now use certain automated functions, the idea of complete autonomy for long periods of time is almost inconceivable. Thus, it seems prudent that the technology program for power subsystem automation be based upon a growth scenario which should provide a structured framework of deliberate steps to enable the evolution of space power subsystems from the current practice of limited autonomy to a greater use of automation with each step being justified on a cost/benefit basis. Each accomplishment should move toward the objectives of decreased requirement for ground control, increased system reliability through onboard management, and ultimately lower energy cost through longer life systems that require fewer resources to operate and maintain. This approach seems well-suited to the evolution of more sophisticated algorithms and eventually perhaps even the use of some sort of artificial intelligence. Multi-hundred kilowatt systems of the future will probably require an advanced level of autonomy if they are to be affordable and manageable.

Graves, J. R.↗

Modeling Control Strategies and Range Impacts for Electric Vehicle Integrated Thermal Management Systems with MATLAB/Simulink

The National Renewable Energy Laboratory's (NREL's) CoolSim MATLAB/Simulink modeling framework was used to explore control strategies for an electric vehicle combined loop system. Three system variants of increased complexity and efficiency were explored: a glycol-based positive temperature coefficient heater (PTC), PTC with power electronics and electric motor (PEEM) waste heat recovery, and PTC with PEEM waste heat recovery plus heat pump versions. Additionally, the benefit of electric motor preheating was considered. A two-level control strategy was developed where the mode selection and component control were treated separately. Only the parameters typically available by vehicle sensors were used to control the system. The control approach included a mode selection algorithm and controllers for the compressor speed, cabin blower flow rate, coolant flow rate, and the front-end heat exchanger coolant bypass rate. The electric motor was bypassed by the cooling circuit until its temperature exceeded the coolant inlet temperature. The impact of these thermal systems on electric vehicle range during warmup was simulated for the Urban Dynamometer Driving Schedule (UDDS) and Highway Fuel Economy Test (HWFET2X) drive cycles weighted 45%/55% respectively. A range of ambient temperatures from -20 degrees C to +20 degrees C was considered. NREL's Future Automotive Systems Technology Simulator (FASTSim) vehicle modeling tool showed up to a 10.9% improvement in range for the full system over the baseline during warmup from cold soak. The full system with preheat showed up to 17% improvement in range.

33 ADVANCED PROPULSION SYSTEMS↗

On the Path to SunShot. Emerging Issues and Challenges in Integrating Solar with the Distribution System

This report analyzes distribution-integration challenges, solutions, and research needs in the context of distributed generation from PV (DGPV) deployment to date and the much higher levels of deployment expected with achievement of the U.S. Department of Energy's SunShot targets. Recent analyses have improved estimates of the DGPV hosting capacities of distribution systems. This report uses these results to statistically estimate the minimum DGPV hosting capacity for the contiguous United States using traditional inverters of approximately 170 GW without distribution system modifications. This hosting capacity roughly doubles if advanced inverters are used to manage local voltage and additional minor, low-cost changes could further increase these levels substantially. Key to achieving these deployment levels at minimum cost is siting DGPV based on local hosting capacities, suggesting opportunities for regulatory, incentive, and interconnection innovation. Already, pre-computed hosting capacity is beginning to expedite DGPV interconnection requests and installations in select regions; however, realizing SunShot-scale deployment will require further improvements to DGPV interconnection processes, standards and codes, and compensation mechanisms so they embrace the contributions of DGPV to system-wide operations. SunShot-scale DGPV deployment will also require unprecedented coordination of the distribution and transmission systems. This includes harnessing DGPV's ability to relieve congestion and reduce system losses by generating closer to loads; minimizing system operating costs and reserve deployments through improved DGPV visibility; developing communication and control architectures that incorporate DGPV into system operations; providing frequency response, transient stability, and synthesized inertia with DGPV in the event of large-scale system disturbances; and potentially managing reactive power requirements due to large-scale deployment of advanced inverter functions. Finally, additional local and system-level value could be provided by integrating DGPV with energy storage and 'virtual storage,' which exploits improved management of electric vehicle charging, building energy systems, and other large loads. Together, continued innovation across this rich distribution landscape can enable the very-high deployment levels envisioned by SunShot.

14 SOLAR ENERGY↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Reporting: Device Demonstration, Communication Protocols, and Codes and Standards

Energy reporting is the principle that all energy-using devices in buildings should be able to track their own energy use and report this to the local network. Energy reporting can provide building owners with easy access to highly granular energy use data. This report makes the case that energy reporting should become a free basic feature of all devices, and reports on a project intended to move us towards that goal. The project collected a set of demonstration devices with energy reporting features, including products that were modified by the project team or the manufacturer, or are already available for sale. To show these devices operating live at meetings and conferences, the team created a management system that queries the energy reporting devices for their data, stores the data, and displays it in compelling visualizations. The devices covered a wide range, including heating, ventilation, and air conditioning (thermostat and air purifier); lighting (individual bulb, task light, and auto-dimming overhead light); a vehicle charger; a water heater; electronics (notebook personal computer and universal serial bus charger); and three external meters (one integral with a dimming light switch). The demonstration uses a variety of communication protocols. The report reviews existing communication protocols that support energy reporting and describes how to use them with a proposed reference data model for energy reporting. It also assesses ways that energy codes and standards processes can be leveraged to drive energy reporting technology into the market. Energy reporting could ultimately save California on the order of 2.5 terawatt-hours per year and about $0.8 billion per year. Energy reporting is a highly practical technology with minimal (sometimes no) cost to consumers and manufacturers. This report discusses creation of the energy reporting devices themselves, analysis and recommendations for data models and protocols for energy reporting, and energy codes and standards implications of energy reporting technology. While energy reporting does not directly save energy, it provides information for better decision-making to save energy in changing equipment operation, maintenance, and replacement.

devices↗

Optimal Power Scheduling for a Medium Voltage AC/DC Hybrid Distribution Network

With the great increase of renewable generation as well as the DC loads in the distribution network; DC distribution technology is receiving more attention; since the DC distribution network can improve operating efficiency and power quality by reducing the energy conversion stages. This paper presents a new architecture for the medium voltage AC/DC hybrid distribution network; where the AC and DC subgrids are looped by normally closed AC soft open point (ACSOP) and DC soft open point (DCSOP); respectively. The proposed AC/DC hybrid distribution systems contain renewable generation (i.e., wind power and photovoltaic (PV) generation); energy storage systems (ESSs); soft open points (SOPs); and both AC and DC flexible demands. An energy management strategy for the hybrid system is presented based on the dynamic optimal power flow (DOPF) method. The main objective of the proposed power scheduling strategy is to minimize the operating cost and reduce the curtailment of renewable generation while meeting operational and technical constraints. The proposed approach is verified in five scenarios. The five scenarios are classified as pure AC system; hybrid AC/DC system; hybrid system with interlinking converter; hybrid system with DC flexible demand; and hybrid system with SOPs. Results show that the proposed scheduling method can successfully dispatch the controllable elements; and that the presented architecture for the AC/DC hybrid distribution system is beneficial for reducing operating cost and renewable generation curtailment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An 85 nW IoT Node-Controlling SoC for MELs Power-Mode Management and Phantom Energy Reduction

This paper presents an ultra-low power (ULP) node-controlling system-on-chip (SoC) used for power-mode management and phantom energy reduction of miscellaneous electric loads (MELs). The SoC is powered from a single 2.5 V voltage supply enabled by the integrated power management unit (PMU) and can control up to 16 MELs due to the on-chip 16-channel correlator and the 32b RISC-V microprocessor. To further reduce the system power consumption, two clock domains have been adopted for the correlator and the processor separately. Fabricated in 65-nm CMOS, the measured minimum power consumption of the proposed SoC is only 85 nW at 0.45 V voltage supply and 1 kHz clock frequency. The measured maximum operating frequency can go up to 148 kHz with a 0.55 V supply. An application experiment successfully demonstrates that the SoC controls the power modes of MELs from wake-up to cut-off to save the average power and phantom energy.

power-mode management, phantom energy, phantom pow↗

Test-Bed Studies Examine PoE

As LED lighting efficacy has steadily improved, and as Power over Ethernet (PoE) standards have evolved to support larger loads, PoE has become viable for an increasing number of lighting devices and applications. As a result, a growing number of lighting manufacturers are introducing PoE lighting systems, making this a potentially disruptive technology. Such systems typically promise enhanced energy management capabilities including accurate reporting of energy use-but we're in the early stages of adoption and there is still a lot we don't know. For example, how exactly is energy use being reported? Which system components are included in reported energy? Is energy loss in PoE cables and connections being reported? Do PoE lighting system architectures vary, and if so, how does that affect their energy use?

Tuenge, Jason R.↗