Gate control of electron correlations towards Mott field effect transistors (MottFET)

The modulation of channel conductance in field-effect transistors (FETs) via metal-insulator-semiconductor structures has revolutionized information processing and storage. However, the limitations of silicon-based FETs in electrical switching have driven the search for new materials capable of overcoming these constraints. Electrostatic gating of competing electronic phases in a Mott material near its metal-to-insulator transition (MIT) offers the prospects of substantial modulation of the conducting electrons and electrical resistivity through small changes in band filling. While electrostatic control of the MIT has been previously reported, the advancement of Mott materials toward novel Mott-based transistors, MottFETs requires the realization of their unique physical properties in a solid-state device. In this study, we present gate control of electron correlation using a solid-state device utilizing the oxide Mott system La 1-x Sr x VO 3 as a correlated FET channel. We report on a gate resistance response that cannot be explained in a purely electrostatic framework. This behavior suggests an enhancement in effective mass and a reduction in effective carrier density as the system approaches its insulating state, consistent with theoretical predictions for Mott systems, suggesting at least 100× charge gain originating from the correlated behavior. These preliminary results pave the way toward the development of highly efficient, low-power electronic devices that could surpass the performance bottlenecks of conventional FETs by leveraging the electronic phase transitions of correlated electron systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Hydrogen Fuel Cell Electric Vehicles

A hydrogen fuel cell electric vehicle (FCEV) is two to three times more efficient than a comparable vehicle powered by an internal combustion engine running on gasoline. Because of their efficient operation, FCEVs can travel long distances with less fueling. An FCEV also produces clean tailpipe exhaust, emitting only water vapor and warm air. FCEVs have driving ranges of more than 300 miles per tank of hydrogen. Drivers can fuel their FCEVs in less than five minutes at a dispenser that looks and feels similar to gasoline dispensers except for the high-pressure gaseous connection.1 In addition, FCEVs are propelled by an electric motor, so they are very quiet, have very few moving parts and fewer fluids to change, and have minimal maintenance requirements overall.

ADVANCED PROPULSION SYSTEMS,HYDROGEN

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY

Zero Emission Cargo Transport (ZECT) II Demonstration: South Coast Air Quality Management District (Final Report)

The South Coast Air Quality Management District (South Coast AQMD), California Air Resources Board (CARB) and Southern California Association of Governments (SCAG) — the agencies responsible for preparing the State Implementation Plan required under the federal Clean Air Act — have agreed that attainment of federal air quality standards for the region will require a transition to the broad use of zero and near-zero emission energy sources in cars, trucks and other equipment. Accordingly, the 2012 South Coast AQMD Air Quality Management Plan, the SCAG 2012 Regional Transportation Plan, and the “Vision for Clean Air: A Framework for Air Quality and Climate Control Planning” all identify the need to immediately enact a phasing in of zero and near-zero emission technologies to meet air quality goals. In 2014, South Coast AQMD was awarded grant funding under the US Department of Energy Zero Emission Cargo Transport (ZECT) II Demonstration program to develop and demonstrate zero-emission drayage trucks for goods movement operations between the Port of Los Angeles (POLA) and Port of Long Beach (POLB) near dock rail yards and warehouses: 1) development and demonstration of zero-emission fuel cell range extended electric drayage trucks and 2) development and demonstration of hybrid electric drayage trucks. The purpose of this project was to accelerate deployment of zero emission cargo transport technologies to reduce harmful diesel emissions, petroleum consumption and greenhouse gases in the surrounding communities along the goods movement corridors that are impacted by heavy diesel traffic and the associated air pollution. Between 2014 – 2024, six ZECT II zero-emission fuel cell drayage truck platforms, including fuel cell range extended and CNG hybrid trucks, were successfully designed, developed, integrated, built, tested, and demonstrated with drayage fleet operators in transportation corridors within areas of the South Coast AQMD jurisdiction in Southern California such as in and around POLA and POLB. Portable hydrogen refueling was deployed to support the fuel cell vehicles. The project had real-time improvement with on-going debugging and optimizations while the vehicles were under demonstration. All platforms demonstrated sufficient or excess power, torque, and energy to support 82,000lbs Gross Vehicle Weight Rating and gradeability to perform their daily duty cycles. Collectively, the trucks drove over 23,000 miles during their respective demonstration phases. The ZECT II project was the first of its kind to demonstrate the commercial viability that supported the additional technology breakthroughs for Class 8 zero emission trucks and validations as well as the regulatory basis for all the zero-emission regulation that we know today, such as the Innovative Clean Transit regulation, Advanced Clean Trucks and Clean Fleet regulations.

08 HYDROGEN

Trends and 2025 Insights on the Rise of Electric Vehicles in the USA

Plug-in electric vehicles (EVs) are reshaping the transportation energy landscape, providing a practical alternative to petroleum fuels for a growing number of applications. EV sales grew 55x in the past decade (2014-2024) and 6x since 2020, driven by technological progress enabled by policies to reduce transportation emissions as well as industrial plans motivated by strategic value of EVs for global competitiveness, jobs and geopolitics. In 2024, 22% of passenger cars sold globally were EVs and opportunities for EVs beyond on-road applications are growing, including solutions to electrify off-road vehicles, maritime and aviation. This Review updates and expands our 2020 assessment of the scientific literature and describes the current status and future projections of EV markets, charging infrastructures, vehicle-grid integration and supply chains in the USA. EV is the lowest-emission motorized on-road transportation option, with life-cycle emissions decreasing as electricity emissions continue to decrease. Charging infrastructure grew in line with EV adoption but providing ubiquitous reliable and convenient charging remains a challenge. EVs are reducing electricity costs in several US markets and coordinated EV charging can improve grid resilience and reduce electricity costs for all consumers. The current trajectory of technology improvement and industrial investments points to continued acceleration of EVs.

33 ADVANCED PROPULSION SYSTEMS

Preliminary System Interface Failure Mode Analysis for Two Advanced Reactors

This study explores two distinct Balance of Plant (BOP) configurations: the Rankine cycle for a sodium-cooled fast reactor (SFR) and the Brayton cycle for a gas-cooled reactor (GCR). As representative designs, the Power Reactor Innovative Small Module (PRISM) by GE Hitachi Nuclear Energy was selected for the SFR, while the Gas Turbine Modular Helium Reactor (GT MHR) by General Atomics was chosen for the gas-cooled reactor. Both configurations were adapted to deliver high-quality heat for industrial applications. A Failure Modes and Effects Analysis (FMEA) was conducted for each system to identify critical failure modes affecting key components. This study marks the first phase of a two-step design optimization approach, integrating FMEA into the design process. Based on the analysis, design modifications and mitigation strategies were proposed to enhance system resilience. The second phase, to be detailed in a subsequent report, will focus on the role of the control system in mitigating these failures. The FMEA serves as a foundation for defining the control topology, ensuring system resilience against component failures that could compromise essential functions, such as electricity and heat production.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Solid oxide electrolysis cell and stack testing best practices

Solid oxide electrolyzer (SOE) technology is an emerging method for hydrogen production, noted for its superior electrical efficiency. Despite the significant progress made in recent years, the broad development of SOE technology is often constrained by the necessary and extensive "skill of the craft" required to successfully test simple single cell test articles. This may be linked to the dearth of practical and pragmatic guidance within the literature for safe, reliable, and performant test equipment and test procedures. Researchers at the Idaho National Laboratory (INL) have been actively testing SOEs ranging from button cells to stacks up to 500 kW, in collaboration with industry and other national laboratories. Based on operational experience, INL has developed system design procedures that ensure safe and reliable operation of SOE systems with the level of support required for each test. This paper presents key aspects of SOE stack and system testing, including safe design procedures, balance of plant components design, and specific implementations at INL. Practical design details of reactants, heat, and power management are presented along with lessons learned from the SOE test facility operations at INL.

08 HYDROGEN

Utility Experience with Inverter-Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. This report identifies various protection challenges due to IBRs that industry is facing.

24 POWER TRANSMISSION AND DISTRIBUTION

MegaWatt Mayhem: Grid Operator Challenges Center Loads

This report provides a summary of the challenges faced by United States electricity grid operators in accommodating and anticipating the rapid deployment of large loads, particularly data centers, based on academic literature and industry working groups. The report highlights the unique requirements and operational characteristics of data centers, which differ significantly from traditional industrial loads. Key issues addressed utility planning considerations, with emphasis on the implications for grid operators, impacts to normal operations for grid operators, reliability considerations during periods of grid stress, and resilience considerations for the changing operational paradigms based on data centers. Real-world examples are used to highlight these challenges and the changes that grid operators must address. The findings underscore the necessity for coordinated efforts and innovative solutions from both grid operators and regulatory bodies to ensure the stable integration of large loads into the grid. This report is the first in a series that will explore the challenges of data center deployments based on several key power system perspectives.

24 - POWER TRANSMISSION AND DISTRIBUTION

Interconnected Risks in Electricity Systems: Understanding Research Challenges, Needs, and Partnerships

The U.S. federal government has a potential role in mitigating the most poorly addressed risks across electricity markets and interdependent systems. Electricity system risks stem from extreme acute shocks (e.g., cyberattacks, extreme weather, and supply chain disruptions) and chronic stressors (e.g., global economic competition, uncertainties surrounding emerging technologies, climate change, and related conflicts). These acute shocks and chronic stressors can result in dire consequences for society, underscoring the need for better information for decision makers in both public and private sectors. Best practices and a shared understanding of risk management and risk quantification must be rapidly developed and disseminated. Informed by a quantitative treatment of risk to electrical infrastructure and interdependent systems, decision makers can more prudently and efficiently prioritize mitigation initiatives to maximize benefits to government, businesses, and the public.

24 POWER TRANSMISSION AND DISTRIBUTION

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION

Spatially Resolved Domicile Charging Demands for Light-, Medium-, and Heavy-Duty Electric Vehicles in Virginia

The use of plug-in electric vehicles (PEVs) and resulting grid impacts are likely to grow rapidly, and evaluation of optimal smart charge management and grid integration strategies is warranted now. Evaluating distribution grid impacts requires fine-grained models of PEV operations to estimate charging loads across diverse vehicles at high spatial resolution. We propose such a model and consider a high-electrification scenario in Richmond and Newport News, Virginia. Our framework considers four categories of vehicle that are amenable to early aggressive electrification: light-duty passenger vehicles (LDV), trucks and vans with a focus on delivery or other local operations, school buses, and transit buses. These vehicles have a relatively consistent domicile, reducing the need for public charging infrastructure rollout to electrify. We apply a recent LDV model and propose new models for each vocation of medium- and heavy-duty vehicle, leveraging telematics data. We demonstrate our framework in Virginia and find energy demands in the region may total 15 GWh day, with most consumed by LDV. However, considering power demand at high spatial resolution reveals a different trend: LDVs have relatively small peak loads at specific sites (peak site demand around 800 kW) compared to average and high demand medium- and heavy-duty vehicle charging sites (peak site demand around 6,000 kW at a transit bus depot, 1,500 kW at a local freight hub, and 1,000 kW at a school). Our framework yields insights on the relative impacts of each vocation and enables future work to tailor grid integration strategies to each vehicle category.

33 ADVANCED PROPULSION SYSTEMS

Unlocking load growth at the grid edge: Practices for managing, recovering, and allocating distribution system investments

Utilities and utility regulators are preparing to make significant investments in the electricity distribution system driven by expected load growth in coming years and decades. Regulators will be tasked with vetting investment proposals and implementing cost recovery and allocation mechanisms. In particular, state regulators are anticipating the need to make proactive distribution system investments, building the capability to serve new load in advance of demand. This report focuses on load growth from homes and businesses that adopt electric vehicles and heat pump heating technologies. Through a review of legislation and regulatory dockets in a subset of states, we provide insights into emerging utility and regulatory practices to recover and allocate costs of electrification-driven distribution system investments necessary to accommodate these technologies. Our review focused on utility electrification programs, line extension policies, and proactive investments. Our report is largely descriptive, offering detailed information about approaches different state commissions and utilities have implemented to inform future decision-making.

24 POWER TRANSMISSION AND DISTRIBUTION

Particle Beam Acceleration Using 3 Petawatt Laser Pulses

The Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) is presently operational at the Gerard Mourou Center for Ultrafast Optical Science (CUOS) at the University of Michigan. ZEUS is a significant upgrade of the previous high power laser systems at CUOS and consists of two beamlines thatoperate in perfect synchronization. The 500 TW beamline became operational in 2023, 2 PW operation started in 2025 and full 3 PW power levels will be available in 2026. It is presently the highest power laser system in the US. In this grant the high field science group at CUOS has leveraged this unique high power laser facility to investigate laser wake field acceleration (LWFA) in ultra-high power laser plasma interactions and have shown how this can scale for future electron–positron colliders at high energy. The dual beam experimental configuration enables flexibility for many frontier experiments in laser-driven acceleration research, in particular, enabling extended channelling/acceleration experiments, positron generation/acceleration experiments and proof-of-principle transverse pumping “dephasingless” electron acceleration experiment and theory. LWFA may be able to miniaturize particle accelerators for high energy physics and also enable new sources of ultrafast, extreme brightness and precise x-rays for a wide variety of applications. In laser wake field acceleration, an electron bunch “surfs” on the electron plasma wave (the “wake field”) generated by the ponderomotive force of an intense laser. The plasma wave has a strong longitudinal electric field that stays in phase with the relativistic driver. A relativistic charged particle may, therefore, remain in phase with the accelerating field over long distances and gain ultra-relativistic energies. The accelerating electric field strength that the plasma wave can support can be many orders of magnitude higher than that of conventional accelerators, which makes laser wakefield acceleration an exciting prospect as an advanced accelerator concept. In this research project we have investigated the scaling of this mechanism to laser powers of 2 PW and have measured the x-ray emission and radio frequency emission resulting from the acceleration process. We have also performed theoretical investigation of mechanisms to scale laser driven accelerators to much higher energy using dephasingless acceleration processes.

43 PARTICLE ACCELERATORS

How well are hazards associated with derechos reproduced in regional climate simulations?

Abstract. A 15-member ensemble of convection-permitting regional simulations of the fast-moving and destructive derecho of 29–30 June 2012 that impacted the northeastern urban corridor of the USA is presented. This event generated 1100 reports of damaging winds, generated significant wind gusts over an extensive area of up to 500 000 km2, caused several fatalities, and resulted in widespread loss of electrical power. Extreme events such as this are increasingly being used within pseudo-global-warming experiments to examine the sensitivity of historical, societally important events to global climate non-stationarity and how they may evolve as a result of changing thermodynamic and dynamic contexts. As such it is important to examine the fidelity with which such events are described in hindcast experiments. The regional simulations presented herein are performed using the Weather Research and Forecasting (WRF) model. The resulting ensemble is used to explore simulation fidelity relative to observations for wind gust magnitudes, spatial scales of convection (as is manifest in high composite reflectivity, cREF), and both rainfall and hail production as a function of model configuration (microphysics parameterization, lateral boundary conditions (LBCs), start date, use of nudging, compiler choice, damping, and number of vertical levels). We also examine the degree to which each ensemble member differs with respect to key mesoscale drivers of convective systems (e.g., convective available potential energy and vertical wind shear) and critical manifestations of deep convection, e.g., vertical velocities, cold-pool generation, and how those properties relate to the correct characterization of the associated atmospheric hazards (wind gusts and hail). Use of a double-moment, seven-class scheme with number concentrations for all species (including hail and graupel) results in the greatest fidelity of model-simulated wind gusts and convective structure to the observations of this event. All ensemble members, however, fail to capture the intensity of the event in terms of the spatial extent of convection and the production of high near-surface wind gusts. We further show very high sensitivity to the LBCs employed and specifically that simulation fidelity is higher for simulations nested within ERA-Interim compared to ERA5. Excess convective available potential energy (CAPE) in all ensemble members after the derecho passage leads to excess production of convective cells, wind gusts, cREF > 40 dBZ, and precipitation during a frontal passage on the subsequent day. This event proved very challenging to forecast in real time and to reproduce in the 15-member hindcast simulation ensemble presented here. Future work could examine if simulations with other initial and lateral boundary conditions can achieve greater fidelity.

Shepherd, Tristan (ORCID:0000000186276419)

Optimizing district energy systems under uncertainty: Insights from a case study from Washington D.C., USA

This study investigates solutions for delivering affordable heating and cooling to a brownfield site, focusing on a case study in Washington, DC. Moving towards more diverse and resilient energy systems, we identify the optimal portfolio for a district energy system with diverse energy sources to meet the area’s energy demands. Our methodological approach integrates two detailed models: one calculating building-level energy demand and the other optimizing district energy technology choices based on their demand profiles, accounting for uncertainties in energy prices, policies, and other parameters. The results provide an economic comparison of district and individual supply options at the building level, emphasizing the flexibility district systems can offer to the electricity sector. District energy systems demonstrate cost-stabilization benefits amidst volatile energy prices and external uncertainties. For heating, district systems yield significant cost savings compared to individual solutions, driven by fuel flexibility and the use of local renewable energy sources. For cooling, district systems also show advantages, though individual systems may remain more cost-effective for smaller buildings. Additionally, district systems exhibit considerable flexibility on the heating side, as evidenced by variations in electricity consumption. We recommend future research to explore the relationship between the economics of district energy systems, particularly at the building level, and their flexibility potential for the electricity sector across diverse geographic contexts to reduce overall grid costs and promote grid reliability. This includes areas with distinct zoning laws, municipal priorities, utility structures, and funding mechanisms, such as the United States, and regions like Europe with pronounced electricity price volatility.

24 POWER TRANSMISSION AND DISTRIBUTION

Business Models for Scaling Demand Flexibility Volume III – Stakeholder ecosystem management challenges, and lessons learned from U.S. programs

Load growth at the grid edge is driving increased attention to the distribution system and its ability to enable customer technology adoption in an affordable and timely manner. Key industry stakeholders, including electric utilities and regulators, can benefit from strategies to manage and balance customer needs with infrastructure investments, such as demand flexibility. This report focuses on demand flexibility—the ability to reduce, shift, shed, generate, or modulate loads in response to building and grid needs—to reduce the need for costly grid upgrades by deferring investment needs and increase system reliability by shifting electricity usage during periods of high risk. Specifically, we focus on the emerging characteristics of business models for demand flexibility as a framework to understand how demand flexibility programs generate value. In this report, we focus on demand flexibility program stakeholder ecosystem management strategies, which provide information on value delivery and describe how program implementers leverage partner capabilities and collaborate to deliver customer and grid benefits. This report discusses the role of stakeholder ecosystem management in demand flexibility programs, identifies existing challenges to effective stakeholder management, and describes lessons learned. This report is part of a series that includes reports on value propositions, customer relationship management strategies, and program life cycle.

24 POWER TRANSMISSION AND DISTRIBUTION

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION