Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Bed form-induced hyporheic exchange and geochemical hotspots

Small-scale bed form topographies control hyporheic exchange and biogeochemical processes within aquatic sediments, which ultimately affect water quality and nutrient cycling at the watershed scale. The impact of three-dimensional and small-scale bed form topographies on hyporheic exchange and solute mixing is investigated in the present work. The effect of bed form morphologies on the development of zones of enhanced reaction rates (i.e., hotspots) is also studied. A computational fluid dynamics model to simulate river flow over bed forms is combined with a subsurface flow and multicomponent reactive solute transport model. A wide variety of bed form topographies are generated using geometric models by varying parameters controlling curvature as well as bed form wavelength and amplitude. The results in this research suggest that out-of-phase bed forms generate more complex hyporheic flow patterns which reduce the efficiency of solute transformations. Higher phase shifts in bed form shapes result in overall higher average velocity, larger zones of enhanced pressure and reaction rates, and higher amounts of solute exchange. Moreover, the bed form shapes control the reaction process for a wide range of sediment conductivities. Here this study advances the understanding of the effects of complex and small scale morphological features on hyporheic exchange processes including the rate and spatio-temporal distribution of reaction hotspots.

54 ENVIRONMENTAL SCIENCES↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Intelligent multi-zone residential HVAC control strategy based on deep reinforcement learning

Residential heating, ventilation, and air conditioning (HVAC) has been considered as an important demand response resource. However, the optimization of residential HVAC control is no trivial task due to the complexity of the thermal dynamic models of buildings and uncertainty associated with both occupant-driven heat loads and weather forecasts. In this paper, we apply a novel model-free deep reinforcement learning (RL) method, known as the deep deterministic policy gradient (DDPG), to generate an optimal control strategy for a multi-zone residential HVAC system with the goal of minimizing energy consumption cost while maintaining the users’ comfort. Here, the applied deep RL-based method learns through continuous interaction with a simulated building environment and without referring to any prior model knowledge. Simulation results show that compared with the state-of-art deep Q network (DQN), the DDPG-based HVAC control strategy can reduce the energy consumption cost by 15% and reduce the comfort violation by 79%; and when compared with a rule-based HVAC control strategy, the comfort violation can be reduced by 98%. In addition, experiments with different building models and retail price models demonstrate that the well-trained DDPG-based HVAC control strategy has high generalization and adaptability to unseen environments, which indicates its practicability for real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Operator learning for energy-efficient building ventilation control with computational fluid dynamics simulation of a real-world classroom

Energy-efficient ventilation control plays an important role in reducing building energy consumption while ensuring occupant health and comfort. While Computational Fluid Dynamics (CFD) simulations provide detailed and physically accurate representations of indoor airflow, their high computational cost limits their use in real-time building control. In this work, we present a neural operator learning framework that combines the physical accuracy of CFD with the computational efficiency of machine learning to enable building ventilation control with the high-fidelity fluid dynamics models. Our method jointly optimizes the airflow supply rates and vent angles to reduce energy use and adhere to air quality constraints. We train an ensemble of neural operator transformer models to learn the mapping from building control actions to airflow fields using high-resolution CFD data. This learned neural operator is then embedded in an optimization-based control framework for building ventilation control. Experimental results show that our approach achieves significant energy savings compared to maximum airflow rate control, rule-based control, as well as data-driven control methods using spatially averaged CO 2 prediction and deep learning–based reduced-order models, while consistently maintaining safe indoor air quality. These results highlight the practicality and scalability of our method in maintaining energy efficiency and indoor air quality in real-world buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles

Heat transfer in directly-irradiated high-temperature solid–gas flows laden with polydisperse particles is investigated using a novel transient three-dimensional computational fluid dynamics model. The model couples particle–gas hydrodynamics of solid–gas flows laden with polydisperse particles, radiative heat transfer in non-grey absorbing, emitting and anisotropically-scattering multi-component participating media, conduction heat transfer in the gas phase, and interfacial convection heat transfer. The multiphase particle-in-cell method is used to predict high-fidelity solid–gas flow characteristics, such as the local discrete particle size distribution, with increased computational efficiency by combining the advantages of both Eulerian and Lagrangian methods. The multi-component radiative transfer model is implemented using an advanced collision-based Monte Carlo ray-tracing method. The number of the prescribed discrete particle components is found to be the key parameter affecting the computational accuracy and efficiency, which primarily depends on the size distribution of the particles. For the model particle–gas flow featuring free-falling Gamma-distributed ceramic particles exposed to concentrated solar irradiation, the particle volume fraction, radiative, fluid flow and thermal characteristics appear to converge with the increasing number of the discrete particle components. Five particle components are sufficient to obtain physically meaningful results. A further increase in the number of the particle components only slightly increases the accuracy of the numerical predictions at the expense of a rapidly increasing computational time. For five particle components, the particle vertical velocity at the receiver exit for particles with the diameter of 43.4 μm is 57% of that for the particles with the diameter of 202.8 μm. The temperatures of these two particle components increase from the initial ambient values by factors of 2 and 1.2, respectively, during the simulation time. In conclusion, the model developed allows for increased fidelity of particle–gas flow simulations with significant radiative effects.

97 MATHEMATICS AND COMPUTING↗

Scale-up of microwave-assisted, continuous flow, liquid phase reactors: Application to 5-Hydroxymethylfurfural production

Microwave (MW) technology can be powerful for the electrification and intensification of chemical manufacturing. However, very few examples of scaled MW processes exist. In this work, we build a scaled, MW-assisted, continuous flow reactor for the processing of liquid phase chemistries with specific application to 5-hydroxymethylfurfural (HMF) production. Here, we demonstrate a corresponding computational fluid dynamics model to simulate the reactor’s temperature profile and performance, both of which are in good agreement with experiments. We construct a surrogate model to relate operating parameters to performance for guiding experiments, without demanding simulations, via active learning. Heat recirculation is demonstrated in this scaled reactor, further extending its scale and reducing the energy demand. An HMF yield of ~55 % and a productivity of 0.1 kg/hr, 8x higher than any other reactor, at a flowrate >20x than prior work, are demonstrated while maintaining energy efficiency of >98 %. A basic economic analysis estimates a $1.85/kg cost of HMF from fructose and >60 % reduction in CO 2 emissions than a conventional system without considering the impact of green electricity. We demonstrate that MW technology is well-applied to systems larger than the laboratory scale, and strategies to further reduction in cost and CO 2 are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into the soft brittle-to-ductile transition from discrete dislocation dynamics

The Brittle-to-ductile transition (BDT) in body centered cubic metals exhibits a soft transition wherein the fracture toughness gradually rises to before the onset of ductility. The resultant brittle-to-ductile transition temperature can be described with an Arrhenius relationship whose activation energy is related to plasticity in the material. To provide further insight into the nature of the BDTT, in this work we utilized a discrete dislo- cation dynamics model with a crack to simulate the BDT and how it depends on the thermally activated nature of plasticity. The interrelationship between the BDT activation energy and the dislocation mobility parameters were determined via the calculation of first order sensitivity coefficients. This analysis allows us to demonstrate that the activation energy for the BDT is directly related to the activation energy for plasticity through an effective stress that defines this relationship. This effective stress physically is the average stress on the dislocations that move out of the crack. Lastly, we are able to show that this effective stress is dictated by the low temperature fracture toughness or cleave energy of the material and the source position, the latter of which can be affected by processing. Collectively, these results provide new insight into what controls the thermal activation of the BDT and what are the important parameters to control it.

36 MATERIALS SCIENCE↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Automated model generation and parameter estimation of building energy models using an ontology-based framework

This study presents a methodology for automated model generation and parameter estimation of building energy models using semantic modeling and Bayesian estimation. Semantic modeling techniques are used to represent the system components and their interactions, facilitating the automatic generation of a simulation model from dynamic component models. The proposed approach is applied to a case study of a ventilation system where a simulation model is generated, calibrated, and assessed through different performance metrics. These metrics demonstrate the accuracy and reliability of both model point estimates and probabilistic prediction intervals across all model outputs. Overall, the proposed methodology offers a systematic and automated approach to model development and calibration in building energy systems, with potential applications in building performance analysis, monitoring, and optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance analysis and tank test validation of a hybrid ocean wave-current energy converter with a single power takeoff

This paper introduces a hybrid ocean wave-current energy converter (HWCEC) that harvests energy from ocean waves and current simultaneously with a single power takeoff (PTO). Specifically, the wave energy is extracted through relative heaving motion between a floating buoy and a submerged second body, while the current energy is extracted using a marine current turbine (MCT). Energy from both sources are integrated by a hybrid PTO whose concept is based on a mechanical motion rectifier (MMR). The hybrid PTO with two one-way clutches converts bidirectional, up-and-down motion from the waves into unidirectional rotation of the generator. Meanwhile a third one-way clutch couples the MCT with the same generator. The wave and current can simultaneously or separately drive the same generator through different engagement and disengagement statuses of the one-way clutches. Time-domain simulation is conducted with hydrodynamic coefficients obtained from computational fluid dynamics analysis and boundary element method. Tank tests were conducted for a HWCEC under co-existing wave and current inputs. For comparison, separate baseline tests of a turbine and a two-body point absorber, each acting in isolation, are conducted. Experimental results validate the dynamic modeling and show that a HWCEC can increase the output power with a range between 29-87% over either current turbine and wave energy converter acting individually, and it can reduce by up to 70% the peak-to-average power ratio compared with the wave energy converter on the tested conditions.

16 TIDAL AND WAVE POWER↗

Feedback Control Approaches for Restoration of Power Grids from Blackouts

The automated restoration of power systems with variable energy resources is a timely problem to tackle. Automated restoration advice can support operators in deciding on strategic actions to restore power grids from a blackout with a mix of conventional and renewable generation resources. To this end, this paper frames the restoration process of power grids with solar resources as a nonlinear dynamic model with algebraic constraints in discrete time which is steered by feedback control loops. We discuss two feedback-control strategies based on greedy and reinforcement learning algorithms, and contrast their performance with restoration plans generated by a mixed-integer linear program. We found that the reinforcement learning algorithm infers restoration actions faster than the greedy one. However, the tuning process of the reinforcement learning parameters is slower than for the greedy one.

machine learning↗

Thermal design analysis for SuperTruck II lithium-titanate battery pack

Here, this paper presents a systematic thermal management analysis for a new lithium-titanate-oxide battery pack to be installed in a SuperTruck II, Class 8 hybrid truck. The authors investigate the feasibility of mounting the battery pack inside the vehicle and air-cooling it with fans supplying conditioned air from the cabin. Moreover, the cells within each module are to be immersed in a heat-transfer fluid to improve temperature homogeneity. A multi-stage thermal analysis is performed to ensure adequate thermal regulation of the battery under the proposed design, considering installation and operational constraints. The authors perform thermal and electrical characterization tests on a single cell. Results inform the development of computational fluid dynamics models of the cells, modules, and pack. Module-level analysis shows that the cell temperatures can be maintained below their upper operational limit of 55 °C with module wall-to-air heat transfer coefficients between 10 and 20 Wm -2 K -1 . Pack-level analysis of distinct configurations determines effective airflow paths for adequate heat transfer and delivers a final battery pack design that achieves sufficient cooling and temperature uniformity. A reduced-order electrothermal model is developed to rapidly predict the transient battery performance and to develop a temperature control strategy.

25 ENERGY STORAGE↗

From MAST-U to STEP: Power exhaust control challenges and opportunities

This work explores the challenges and opportunities for power exhaust control in STEP, informed by dedicated MAST-U experiments. The STEP system primarily relies on hydrogenic and argon gas injection into the divertors, compensating for transients originating in the plasma core. Fast transients (>10 Hz) that evolve too quickly for actuators to compensate must be absorbed passively; the enhanced transient buffering of the foreseen long-legged divertor provides a clear advantage over conventional geometries, as demonstrated in the MAST-U Super-X divertor. Experiments further indicate that STEP’s tight divertor baffling enables near-independent control of the upper and lower divertors. The most challenging transients are expected from power-sharing fluctuations, as MAST-U experiments observed extremely fast dynamics. Fluctuations from core pellet fuelling remain relatively benign due to the small pellet size according to simulations. Exhaust control in a reactor like STEP requires an integrated approach befitting its machine-critical nature. A predictive control element, integrated with core plasma control, allows pre-emptive preparation of the divertor for incoming transients. An observer-based diagnostic approach is foreseen to monitor the divertor in the challenging reactor environment, supported by an extended diagnostic set in the non-nuclear phase to validate the required dynamic models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A workflow to assess the efficacy of brine extraction for managing injection-induced seismicity potential using data from a CO 2 injection site near Decatur, Illinois

Injection of CO 2 for storage in a geologic formation increases pore pressure and alters in situ stresses. Depending on the orientation of any existing fault and fracture planes, such as critically stressed planes, this stress alteration will modify normal stresses acting on planes and could result in frictional sliding and release stored energy in the form of seismicity. Brine extraction (BE) is a technique that can be applied prior to, or during, CO 2 injection to reduce pore pressure for increasing storage capacity and, potentially, for reducing the likelihood of frictional sliding. Here a workflow is described to assess the efficacy of BE for mitigating frictional sliding (i.e., seismicity) during injection and entails: site characterization, stress calculations and failure assessment, static and dynamic modeling, and BE operational planning. Site characterization describes the stress field used to calculate the Coulomb Failure Function (CFF) that constrains allowable pore pressure changes and injection rates in the numerical simulation of CO 2 injection scenarios. The inclusion of BE in the workflow allows for determination of the potential need for pressure reduction, and evaluation of the effectiveness of this operation. Example application of the workflow using an injection field dataset near Decatur, IL, provides insight on fracture planes and stresses at the site, formation properties and the impact of variable CO 2 injection-rate targets on whether BE plans are required. The study workflow indicates that BE could enhance CO 2 injection rate by 39% and correspondingly reduce the potential for injection-induced seismicity as indicated by a reduction in CFF.

58 GEOSCIENCES↗

Thermal management of a high temperature sodium sulphur battery stack

The sodium sulfur battery is an advanced secondary battery with high potential for grid-level storage due to their high energy density, low cost of the reactants, and high open-circuit voltage. However, as the operating temperature of the battery is high (about 300 °C), effective thermal management is required to prevent thermal runaway under high current density operation. Here, to develop efficient thermal management strategies, a detailed, thermo-electrochemical, non-isothermal, distributed dynamic model of a sodium-sulfur battery stack is developed. Models of three thermal management strategies are developed and analyzed in this work: active cooling, passive cooling, and hybrid cooling. The active cooling strategy uses air as the cooling medium whereas, the passive cooling strategy uses a phase change material. In the hybrid cooling strategy, both active and passive cooling strategies are used. Due to the high operating temperature of the sodium sulfur batteries, the rejected heat can be utilized effectively and consequently a high variability in the heat rejection rate may not be acceptable. Performance of these strategies is analyzed under high current density operation by evaluating the variability in the cell temperature during charge/discharge cycles, temperature difference between the cells based on their locations, and variability in the heat rejection rate. The phase change-based hybrid thermal management strategy with an embedded controller maintained the temperature variation within ±/- 2.8 °C. Considering the tradeoff between the capital cost for PCM, fan power requirement, and variability in the heat rejection rate, the optimal quantity of the PCM and the maximum air velocity for the maximum current density of 260 mA/cm 2 (0.55 C-rate) were found be 0.74 g/Wh and 3 m/s, respectively.

25 ENERGY STORAGE↗

Approximation of refrigerant thermophysical properties using neural networks to speed up transient thermofluid simulations

Accurate and efficient evaluations of refrigerant thermophysical properties and their partial derivatives are essential for transient simulations of thermofluid systems, where several computations need to be executed at each integration time step. Since the utilization of an Equation of State for retrieving properties based on a pair of independent inputs typically involves numerical iterations in solution procedures, when the input variables differ from the refrigerant state variables employed in dynamic models, a variety of approaches including lookup table interpolation and curve fitting have been developed to explicitly approximate these properties based on the state variables, and consequently eliminate internal iterations. This paper presents an alternative method that exploits derivative-informed neural networks to model refrigerant properties explicitly from inputs of pressure and enthalpy, while ensuring consistent partial derivatives generated by differentiating the neural networks. Computational speed and accuracy of the proposed approach are demonstrated via transient simulations of a discretized heat exchanger model in Modelica, and comparisons against other property evaluation routines. Simulation results indicate that the proposed approach can realize a significant speedup with negligible discrepancies in predicted transients. The method is implemented in an open-source Modelica library.

Ma, Jiacheng↗

Correlating inter-particle forces and particle shape to shear-induced aggregation/fragmentation and rheology for dilute anisotropic particle suspensions: A complementary study via capillary rheometry and in-situ small and ultra-small angle X-ray scattering

Predicting the stability of suspensions composed of anisotropic particles is difficult due to the complexity and interplay of hydrodynamic and colloidal forces. For example, it is not well understood how non-spherical particle shapes affect suspension-rheological responses. This study presents evidence showing how the stacking of boehmite platelets dispersed in aqueous solution leads to moderate shear thinning, even at low boehmite mass fractions. Wide angle X-ray, small angle X-ray, and ultra-small angle X-ray scattering were used to simultaneously monitor changes to the size and fractal dimensions of boehmite aggregates from 6 – 10,000 Å as the sample was recirculated through an in situ capillary rheometer. The latter also provided simultaneous measurements of the viscosity of the suspensions. Computational fluid dynamics modeling of the apparatus was used to provide a more rigorous analysis of the fluid flow. In addition to shear-induced aggregation/fragmentation correlated to a complicated balance between hydrodynamic and colloidal forces, the results indicate that orientationally-dependent interactions, arising from non-spherical boehmite aggregate sub-units, may explain the relatively large experimental viscosity when the hydrodynamic force is small compared to colloidal forces. Ultimately, the results from this study can provide a foundation for future work investigating particle shape effects on colloidal and hydrodynamics forces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗