Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Note: Frequency-conversion photonic Doppler velocimetry with an inverted circulator

Photonic Doppler velocimetry (PDV) is a fiber-based interferometer used in dynamic compression research. Conventional PDV systems are simple to construct but do not perform well in all measurement conditions, while universal PDV systems that support many different configurations are complex and expensive. A simpler approach is the use of external, inverted circulators which can be added and removed in a modular fashion. This technique permits frequency-conversion measurements with a conventional PDV system. Using a correction to remove baseline effects, frequency conversion systems can resolve low velocity transients that conventional PDV cannot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution ion Doppler spectroscopy at Prairie View Rotamak

A fast ion Doppler spectroscopy (IDS) diagnostic system is installed on the Prairie View Rotamak to measure ion temperature and plasma flow. The diagnostic employs a single channel photomultiplier tube and a Jarrell-Ash 50 monochromator with a diffraction grating line density of 1180 lines/mm, which allows for first order spectra of 200-600 nm. The motorized gear of the monochromator allows spectral resolution of 0.01 nm. Equal IDS measurements are observed for various impurity emission lines of which carbon lines exhibit stronger intensities. Furthermore, the diagnostics is examined in an experiment where plasma experiences sudden disruption and quick recovery. In this case, the IDS measurements show {approx}130% increase in ion temperature. Flow measurements are shown to be consistent with plasma rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution spectroscopy for Doppler-broadening ion temperature measurements of implosions at the National Ignition Facility

Future implosion experiments at the national ignition facility (NIF) will endeavor to simultaneously measure electron and ion temperatures with temporal and spatial resolution in order to explore non-equilibrium temperature distributions and their relaxation toward equilibrium. In anticipation of these experiments, and with understanding of the constraints of the NIF facility environment, we have explored the use of Doppler broadening of mid-Z dopant emission lines, such as krypton He-{alpha} at 13 keV, as a diagnostic of time- and potentially space-resolved ion temperature. We have investigated a number of options analytically and with numerical raytracing, and we have identified several promising candidate spectrometer designs that meet the expected requirements of spectral and temporal resolution and data signal-to-noise ratio for gas-filled exploding pusher implosions, while providing maximum flexibility for use on a variety of experiments that potentially include burning plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2D full wave modeling for a synthetic Doppler backscattering diagnostic

Doppler backscattering (DBS) is a plasma diagnostic used in tokamaks and other magnetic confinement devices to measure the fluctuation level of intermediate wavenumber (k{sub {theta}}{rho}{sub s}{approx} 1) density fluctuations and the lab frame propagation velocity of turbulence. Here, a synthetic DBS diagnostic is described, which has been used for comparisons between measurements in the DIII-D tokamak and predictions from nonlinear gyrokinetic simulations. To estimate the wavenumber range to which a Gaussian beam would be sensitive, a ray tracing code and a 2D finite difference, time domain full wave code are used. Experimental density profiles and magnetic geometry are used along with the experimental antenna and beam characteristics. An example of the effect of the synthetic diagnostic on the output of a nonlinear gyrokinetic simulation is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision lifetime measurements of exotic nuclei based on Doppler-shift techniques

A recent progress in precision lifetime measurements of exotic nuclei at the National Superconducting Cyclotron Laboratory (NSCL), Michigan State University is presented. The Recoil Distance Doppler-shift (RDDS) technique has been applied to nuclear reactions involving intermediate-energy rare isotope (RI) beams, to determine absolute transition strengths between nuclear states model independently from level lifetimes of interest. As such an example, recent lifetime measurements of the first 2{sup +} states in the neutron-rich {sup 62,64,66}Fe isotopes at and around N=40 are introduced. The experiment was performed at the Coupled Cyclotron Facility at NSCL using a unique combination of several experimental instruments; the Segmented Germanium Array (SeGA), the plunger device, and the S800 spectrograph. The reduced E2 transition probabilities B(E2) are determined directly from the measured lifetimes. The observed trend of B(E2) clearly demonstrates that an enhanced collectivity persists in {sup 66}Fe despite the harmonic-oscillator magic number N=40. The present results are also discussed in comparison with the large-scale shell model calculations, pointing to a possible extension of the deformation region beyond N=40.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-channel Doppler backscattering measurements in the C-2 field reversed configuration

A versatile heterodyne Doppler Backscattering (DBS) system is used to measure density fluctuation levels (in the wavenumber range kρ{sub s} ≤ 50), and the toroidal E × B flow velocity in the C-2 Field-Reversed Configuration (FRC). Six tunable frequencies in three waveguide bands (26 GHz ≤ f ≤ 90 GHz) are launched using monostatic beam optics, via a quasi-optical beam combiner/polarizer and an adjustable parabolic focusing mirror (inside the vacuum enclosure) achieving Gaussian beam spot sizes of 3–5.5 cm at the X/O-mode cutoff. The DBS system covers plasma densities of 0.8 × 10{sup 13} ≤ n{sub e} ≤ 1 × 10{sup 14} cm{sup −3}, and provides access to the FRC core (up to the field null) and across the FRC separatrix into the scrape-off layer plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Velocity space evolution of a minority energetic electron population undergoing the anomalous Doppler instability

The kinetic evolution in velocity space of a minority suprathermal electron population that is undergoing the anomalous Doppler instability (ADI) is investigated using the results from fully nonlinear numerical simulations that self-consistently evolve particles and fields in a plasma. Electron trajectories in phase space during different stages of the ADI are captured, and are analysed in relation to the characteristics of the excited electric fields and of the overall distribution of particles. For some electrons, trapping and mirroring effects are observed during the saturation phase. A relationship between the second order moments of the perpendicular electron distribution function and time is established, and is used to investigate the range of applicability of analytical approximations drawn from classical theory, that involve a quasilinear wave-driven diffusion operator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Doppler-shifted photons on subnanosecond breakdown in high-voltage pulse discharge

The experiments in high-voltage open discharge in helium [1, 2] showed a controlled current growth rate of 500 A/(cm{sup 2}ns) for an applied voltage of 20 kV and gas pressure of 6 Torr. A kinetic model of the subnanosecond breakdown is developed to analyze the mechanism of current growth, which takes into account the kinetics of electrons, ions, fast atoms and photons with a Doppler shift (DS). DS photons appear in discharge due to collisions of heavy particles. Using particle in cell simulations, we show a critical role of DS photons in the electron emission from the cathode during the breakdown. Our experimental and calculation results show a decrease of the breakdown time with increasing gas pressure from 3 Torr to 16 Torr.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary measurements of the edge magnetic field pitch from 2-D Doppler backscattering in MAST and NSTX-U (invited)

The Synthetic Aperture Microwave Imaging (SAMI) system is a novel diagnostic consisting of an array of 8 independently phased antennas. At any one time, SAMI operates at one of the 16 frequencies in the range 10-34.5 GHz. The imaging beam is steered in software post-shot to create a picture of the entire emission surface. In SAMI’s active probing mode of operation, the plasma edge is illuminated with a monochromatic source and SAMI reconstructs an image of the Doppler back-scattered (DBS) signal. By assuming that density fluctuations are extended along magnetic field lines, and knowing that the strongest back-scattered signals are directed perpendicular to the density fluctuations, SAMI’s 2-D DBS imaging capability can be used to measure the pitch of the edge magnetic field. In this paper, we present preliminary pitch angle measurements obtained by SAMI on the Mega Amp Spherical Tokamak (MAST) at Culham Centre for Fusion Energy and on the National Spherical Torus Experiment Upgrade at Princeton Plasma Physics Laboratory. Lastly, the results demonstrate encouraging agreement between SAMI and other independent measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple new methods for deducing lifetimes in recoil distance Doppler-shift measurements

In this work, new approaches for lifetime determination using data from recoil distance Doppler-shift experiments are presented based on the fundamental properties of the functions describing the time evolution of the population of excited nuclear states. To some extent, one of them represents a contraction of the well-known Differential decay-curve method (DDCM) by using the most reliable data point [the maximum of the $n_i(t)$ function describing the population of level $\textit{i}$ in time] and a purely numerical procedure avoiding any fitting of decay curves. The combination with the standard DDCM analysis is promising for improving the reliability and the precision of the results for the lifetimes obtained. The novel part of the approach consists of using a chain of equations at the consecutive maxima of the ni(t) functions, which allow us to precisely determine the ratio of the lifetimes of two consecutive levels and, in the case where one of these lifetimes is known, to determine the unknown one. In addition, a simple integral derivation of the lifetime is presented involving the peak areas measured at different distances, and an application of the first moments (expectation values and centroids in time) of the $n_i(t)$ functions for determining lifetimes is also demonstrated to be useful.

47 OTHER INSTRUMENTATION↗

Evaluation of a new DIII-D Doppler backscattering system for higher wavenumber measurement and signal enhancement

The high density fluctuation poloidal wavenumber, k θ (k θ > 8 cm –1 , k θ ρ s > 5, ρs is the ion gyro radius using the ion sound velocity), measurement capability of a new Doppler backscattering (DBS) system at the DIII-D tokamak has been experimentally evaluated. In DBS, wavenumber (k) matching becomes more important at higher wavenumbers, owing to the exponential dependence of the measured signal loss factor on wave vector mismatch. Wave vector matching allows for the Bragg scattering condition to be satisfied, which minimizes the signal loss at higher k’s. In the previous DBS system, without toroidal wave vector matching, the measured DBS signal-to-noise ratio at higher k θ (>8 cm –1 ) is substantially reduced, making it difficult to measure higher k θ turbulence. The new DBS system has been optimized to access higher wavenumber, k θ ≤ 20 cm –1 , density turbulence measurement. The optimization hardware addresses fluctuation wave vector matching using toroidal steering of the launch mirror to produce a backscattered signal with improved intensity. The probe’s sensitivity to high-k density fluctuations has been increased by approximately an order of magnitude compared to the old system that has been in use at DIII-D. Note that typical measurement locations are above or below the tokamak midplane on the low field side with normalized radial ranges of 0.5–1.0. As a result, the new DBS probe system with the toroidal matching of fluctuation wave vectors is thought to be critical to understanding high-k turbulent transport in fusion-relevant research at DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel Doppler backscattering (DBS) system to simultaneously measure radio frequency plasma fluctuations and low frequency turbulence

A novel quadrature Doppler Backscattering (DBS) system has been developed and optimized for the E-band (60–90 GHz) frequency range using either O-mode or X-mode polarization in DIII-D plasmas. In general, DBS measures the amplitude of density fluctuations and their velocity in the lab frame. The system can simultaneously monitor both low-frequency turbulence (f < 10 MHz) and radiofrequency plasma density fluctuations over a selectable frequency range (20–500 MHz). Detection of high-frequency fluctuations has been demonstrated for low harmonics of the ion cyclotron frequency (e.g., 2f ci ~ 23 MHz) and externally driven high-frequency helicon waves (f = 476 MHz) using an adjustable frequency down conversion system. Importantly, this extends the application of DBS to a high-frequency spectral domain while maintaining important turbulence and flow measurement capabilities. This unique system has low phase noise, good temporal resolution (sub-millisecond), and excellent wavenumber coverage (k θ ~ 1–20 cm –1 and kr ≲ 30 cm –1 ). As a demonstration, localized internal DIII-D plasma measurements are presented from turbulence (f ≤ 5 MHz), Alfvenic waves (f ~ 6.5 MHz), ion cyclotron waves (f ≥ 20 MHz), as well as fluctuations around 476 MHz driven by an external high-power 476 MHz helicon wave antenna. In the future, helicon measurements will be used to validate GENRAY and AORSA modeling tools for prediction of helicon wave propagation, absorption, and current drive location for the newly installed helicon current drive system on DIII-D.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗

Laser Doppler visualisation of the velocity field by excluding the influence of multiparticle scattering

The method of laser Doppler visualisation and measurement of the velocity field in gas and liquid flows by suppressing the influence of multiparticle scattering is discussed. The cross section of the flow under study is illuminated by a laser beam transformed by an anamorphic optical system into a laser sheet. The effect of multiparticle scattering is eliminated by obtaining differential combinations of frequency-demodulated images of the laser sheet in different regions of the angular spectrum of scattered light. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dependence of emergence of the collapse and revival effect of Doppler - Rabi osciallations on the initial state of the moving-atom - electromagnetic-field system

The quantum dynamics of a system consisting of a moving two-level atom and a single-mode electromagnetic field in the standing-wave resonator is studied by using the stationary phase approximation. The conditions resulting in the emergence of the collapse - revival effect of Doppler - Rabi oscillations are analysed for the initial coherent state of the electromagnetic field in the resonator. It is shown that both the character and the possibility of this effect emergence directly depend on the initial parameters of the system: the rate of the atomic centre-of-mass motion, coupling constants of the atom with the field, the mean number of photons in the resonator. Under conditions when the collapse - revival effect is absent, the system dynamics qualitatively depends on the intial electronic state of the atom. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Doppler optical mixing spectroscopy in multiparticle scattering fluids

We discuss the basic scheme of laser Doppler optical mixing spectroscopy for the analysis of media with multiparticle scattering. It is shown that the Rayleigh scheme, in contrast to the heterodyne and differential schemes, is insensitive to the effects of multiparticle scattering. (laser applications and other aspects of quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent population trapping resonances at lower atomic levels of Doppler broadened optical lines

We have detected and analysed narrow high-contrast coherent population trapping (CPT) resonances, which are induced in absorption of a weak monochromatic probe light beam by counterpropagating two-frequency pump radiation in a cell with rarefied caesium vapour. The experimental investigations have been performed by the example of nonclosed three level Λ-systems formed by spectral components of the D{sub 2} line of caesium atoms. The applied method allows one to analyse features of the CPT phenomenon directly at a given low long-lived level of the selected Λ-system even in sufficiently complicated spectra of atomic gases with large Doppler broadening. We have established that CPT resonances in transmission of the probe beam exhibit not only a higher contrast but also a much lesser width in comparison with well- known CPT resonances in transmission of the corresponding two-frequency pump radiation. The results obtained can be used in selective photophysics, photochemistry and ultra-high resolution atomic (molecular) spectroscopy. (laser applications and other topics in quantum electronics)

74 ATOMIC AND MOLECULAR PHYSICS↗