Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

A focussing iron line crystal spectrometer for Spacelab

A crystal spectrometer system is described which employs conical focusing of 12 curved LiF crystal panels to minimize the detector size and reduce the background counting rate. The wavelength range from 1.70 to 1.98 A is covered, including the resonance lines of Fe XXV and Fe XXVI as well as the Fe I K-alpha line and absorption edge. Operation of the spectrometer is discussed, noting that diffracted X-rays are registered in one-dimensional position-sensitive detectors and that the arrival position of a photon in a detector is related to its wavelength due to the fixed curvature of the crystal panels in the dispersion plane. Some characteristics of the multianode position-sensitive detectors are reviewed along with the crystal arrangement and mounting. The instrument sensitivity is evaluated in relation to the strengths of 6.7-keV emission features detected by the Ariel 5 and OSO 8 proportional-counter spectrometers.

Catura, R. C.↗

Analysis of spatial pseudodepolarizers in imaging systems

The objective of a number of optical instruments is to measure the intensity accurately without bias as to the incident polarization state. One method to overcome polarization bias in optical systems is the insertion of a spatial pseudodepolarizer. Both the degree of depolarization and image degradation (from the polarization aberrations of the pseudodepolarizer) are analyzed for two depolarizer designs: (1) the Cornu pseudodepolarizer, effective for linearly polarized light, and (2) the dual Babinet compensator pseudodepolarizer, effective for all incident polarization states. The image analysis uses a matrix formalism to describe the polarization dependence of the diffraction patterns and optical transfer function.

Mcguire, James P., Jr.↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses that may not be important in longer wavelength designs. This paper describes the design of multi- bandwidth filters operating in the 1-5 micrometer wavelength range. This work follows on a previous design. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using microlithographic techniques and used in spectral imaging applications will be presented.

Cwik, Tom↗

Neuregulin: First Steps Towards a Structure

Neuregulins are growth factor domain proteins with diverse bioactivities, such as cell proliferation, receptor binding, and differentiation. Neureguh- 1 binds to two members of the ErbB class I tyrosine kinase receptors, ErbB3 and ErbB4. A number of human cancers overexpress the ErbB receptors, and neuregulin can modulate the growth of certain cancer types. Neuregulin-1 has been shown to promote the migration of invasive gliomas of the central nervous system. Neuregulin has also been implicated in schizophrenia, multiple sclerosis and abortive cardiac abnormalities. The full function of neuregulin-1 is not known. In this study we are inserting a cDNA clone obtained from American Type Culture Collection into E.coli expression vectors to express neuregulin- 1 protein. Metal chelate affinity chromatography is used for recombinant protein purification. Crystallization screening will proceed for X-ray diffraction studies following expression, optimization, and protein purification. In spite of medical and scholarly interest in the neuregulins, there are currently no high-resolution structures available for these proteins. Here we present the first steps toward attaining a high-resolution structure of neuregulin- 1, which will help enable us to better understand its function

Ferree, D. S.↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses tha_ may not be important in longer wavelength designs. This paper describes the design of multi-bandwidth filters operating in the I-5 micrometer wavelength range. This work follows on previous design [1,2]. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using micro-lithographic techniques and used ir spectral imaging applications will be presented.

Cwik, Tom↗

Technology Development Roadmap for Habitable-Zone Exoplanet Observatory (HabEx) Baseline 4-M Primary Mirror

The Habitable Exoplanet Observatory (HabEx) is one of four mission concepts under study for the 2020 Astrophysics Decadal Survey. Its goal is to directly image and spectroscopically characterize planetary systems in the habitable zone around nearby sun-like stars. Additionally, HabEx will perform a broad range of general astrophysics science enabled by 115 to 2500 nm spectral range and 3 x 3 arc-minute FOV. Critical to achieving the HabEx science goals is a large, ultra-stable UV/Optical/Near-IR (UVOIR) telescope. The baseline HabEx telescope is 4-meter off-axis unobscured, diffraction limited at 400 nm with wavefront stability on the order of a few 10s of picometers. The technology readiness level (TRL) to manufacture and test the HabEx baseline primary mirror is assessed to be at TRL-6 for all but two TRL-4 technologies: 1) non-destructive process to quantify CTE homogeneity of a 4-m mirror substrate with a spatial sampling of at least 100 x 100 to better than +/- 1 ppb/K; and, 2) process to quantify self-weight gravity deflection to better than 4-nm rms over a 100 x 100 spatial sampling. This paper reviews the technology needs to manufacture the HabEx primary mirror, assesses their TRL and proposes a roadmap to mature the two remaining technologies to TRL-6.

Space Telescope Technology↗

Aircraft System Noise Assessment of the NASA D8 Subsonic Transport Concept

Avehicle-level noise assessment has been performed for theNASAD8 concept aircraft (ND8) in the NASA Advanced Air Transport Technology Project portfolio. The NASA research-level Aircraft NOise Prediction Program (ANOPP-Research) was used to predict the noise from each source component on the ND8 to build up a noise estimate for the full aircraft. The propulsion airframe aeroacoustic (PAA) effects of the ND8, namely boundary layer ingestion (BLI) with its influence on fan noise, and the noise shielding, reflection, and diffraction mechanisms of the unconventional airframe, were empirically modeled using experimental data. Noise reduction technologies appropriate to the 2025-2035 time frame were included in this study. Including all technologies and PAA effects, the ND8 is predicted to have a cumulative margin to the Stage 4 certification metric of only 7.4 EPNdB. Boundary layer ingestion is predicted to have a detrimental impact on cumulative noise levels on the order of 15 EPNdB. Fan noise is seen to be the primary noise source at all three certification points, even if the BLI noise impact could be entirely suppressed. The impact of engine noise shielding by the airframe is limited by a lack of aft shielding and the presence of horizontal tail reflections in the aft direction. The physical constraint on engine size by the pi-tail is seen as a potential barrier to engine noise reduction through the corresponding limitation on fan bypass ratio. Mildly reduced climb performance (compared to similar reference aircraft) does not provide any benefit through increased noise propagation distance. If the boundary layer ingestion noise penalty could be suppressed such that BLI would have no effect on noise, the cumulative margin to Stage 4 would increase to 22.4 EPNdB, still below the NASA Mid Term goal of 32-42 EPNdB.

Clark, Ian A.↗

A spectral identification technique for adaptive attitude control and pointing of the Space Telescope

The Space Telescope is a 2.4 m class aperture optical telescope having near-diffraction-limited performance. It will be placed into earth orbit by 1980 via the Space Shuttle. The problem considered is how to achieve negligible degradation of the astronomy imaging capability (to 0.005 arc second) due to smearing by pointing motions during observations. Initially, pointing instability sources were identified and a linear stability was used to assess the magnitude of elastic body modes and to design control system compensation regions necessary for subsequent adaptive control. A spectral identification technique for this adaptive attitude control and pointing has been investigated that will alleviate requirements for comprehensive dynamic ground testing. Typical all-digital simulation results describing motions of the telescope line of sight are presented.

Teuber, D. L.↗

Procedures for dealing with certain types of noise and systematic errors common to many Hadamard transform optical systems

Sources of noise and error correcting procedures characteristic of Hadamard transform optical systems were investigated. Reduction of spectral noise due to noise spikes in the data, the effect of random errors, the relative performance of Fourier and Hadamard transform spectrometers operated under identical detector-noise-limited conditions, and systematic means for dealing with mask defects are among the topics discussed. The distortion in Hadamard transform optical instruments caused by moving Masks, incorrect mask alignment, missing measurements, and diffraction is analyzed and techniques for reducing or eliminating this distortion are described.

Harwit, M.↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

Fazio, Giovanni G.↗

James Webb Space Telescope: The First Light Machine

NASA James Webb Space Telescope (JWST) will search for the first luminous objects of the Universe to help answer fundamental questions about how the Universe came to look like it does today. At 6.5 meters in diameter, JWST will be the world's largest space telescope. Its architecture, e.g. aperture, wavelength range and operating temperature, is driven by JWST's science objectives. Introduction: Scheduled to start its 5 year mission after 2018, JWST will study the origin and evolution of galaxies, stars and planetary systems. Its science mission is to: Identify the first bright objects that formed in the early Universe, and follow the ionization history. Determine how galaxies form. Determine how galaxies and dark matter, including gas, stars, metals, overall morphology and active nuclei evolved to the present day. Observe the birth and early development of stars and the formation of planets. And, study the physical and chemical properties of solar systems for the building blocks of Life. Principle: To accomplish the JWST science objectives requires a larger aperture infrared cryogenic space telescope. A large aperture is required because the objects are very faint. The infrared spectral range is required because the objects are so far away that their ultraviolet and visible wavelength spectral lines are red-shifted into the infrared. Because the telescope is infrared, it needs to be cryogenic. And, because of the telescope is infrared, it must operate above the Earth's atmosphere, i.e. in space. JWST is probably the single most complicated mission that humanity has attempted. It is certainly the most difficult optical fabrication and testing challenge of our generation. The JWST 6.5 m diameter primary mirror is nearly a parabola with a conic constant of -0.9967 and radius of curvature at 30K of 15.880 m. The primary mirror is divided into 18 segments with 3 different prescriptions; each with its own off-axis distance and aspheric departure. The radius of curvature for all 18 segments must match to +/- 0.150 mm at 30K. JWST is diffraction limited at 2 micrometers which translates into a transmitted wavefront specification of 156 nm rms. Of that amount, 50 nm rms is allocated to the primary mirror. Each segment is allocated 22 nm rms surface error. At the start of the JWST program, the capability to make such a mirror did not exist. In 1996, NASA began a systematic and comprehensive mirror technology development effort which resulted in JWST. This program resulted in a qualified mirror fabrication process being approved in 2006. Today, all JWST primary mirror segments meet their requirements and are on schedule for a 2018 launch. The next step is system level assembly, integration and test. Ambient tests will be conducted at Goddard Space Flight Center and cryogenic system level testing will be performed in Chamber A at the Johnson Space Center.

Stahl, H. Philip↗

Plans for a large deployable reflector for submillimeter and infrared astronomy from space

Continuing plans for a large deployable reflector (LDR), conceived as a 10- to 30-m-diameter clear-aperture telescope, operating at wavelengths from 1000 microns to a diffraction-limited 30 microns, and to be placed in orbit for a life of 10 years by the Space Shuttle, are discussed. The primary reflector will be composed of a number of closely packed hexagonal segments of glass or lightweight composite material and attached to a truss integrating structure through position actuators providing three degrees of freedom for each segment. Technical aspects of optical design, surface measurement systems, deployment, and detectors are discussed, as are practical and fiscal limitations.

Swanson, P. N.↗

Real-time optical correlator using photorefractive GaAs

A real-time optical correlator based on GaAs and liquid-crystal TV (LCTV) is demonstrated. The demonstrated system has a video-frame rate limited by the speed of the LCTVs; if faster spatial-light modulators are used, the potential frame rate of a GaAs-based correlator can be as fast as 1000 frames/sec under experimental conditions. Comparisons are made between VanderLugt and joint transform and between degenerate and nondegenerate four-wave mixing. The edge-enhancement effect and the Bragg diffraction effect are discussed.

Liu, Duncan T. H.↗

Commercial researcher perspective

Protein crystallography--a research tool used to study the structure of the complex building blocks of living systems--has a lot to gain from space-based research. In order to know how a protein works in the human body, researchers must understand its molecular structure. Researchers have identified 150,000 different proteins in the body, but they now know the structure of less than a third of them. The only viable technique for analyzing the structure of these proteins is x-ray diffraction of the proteins in their crystal form. The better the quality of a protein crystal, the more useful it is to researchers who are trying to delineate its structure. The microgravity environment of space allows protein crystals to grow nearly undisturbed by convection and other gravity-driven forces that cause flaws to form in them on the ground. In space, lack of convection enables protein crystals to grow more slowly than they do on Earth, and the slower a protein crystal grows, the fewer flaws it will have. Protein crystal growth experiments have already flown on 14 Space Shuttle missions. This year's USML-1 Spacelab mission included protein crystal growth experiments conducted for commercial researchers. The results of protein crystal experiments flown thus far have been larger crystals with more uniform morphologies. The Center for Macromolecular Crystallography (A NASA-cosponsored CCDS) currently builds flight hardware to meet researchers' needs and handles sample loading and retrieval for flight experiments. Protein crystallography enables 'rational drug design': the development of drugs that bind only with the target protein and, hence, do not cause side effects. For example, pharmaceutical companies presently are interested in developing drugs that can inhibit purine nucleoside phosphorylase (PNP), a protein that plays a role in auto-immune diseases. To continue these kinds of investigations, researchers need a constant supply of protein crystals that are as free of flaws as possible. Space Station Freedom will provide the kind of research environment that will enable the production of such supplies. In addition, Freedom will provide the kind of long-duration facility required by protein crystal researchers: 40 percent of proteins require more than two weeks to crystallize.

Delucas, Larry↗

The Evolution of the Deformation Substructure in a Ni-Co-Cr Equiatomic Solid Solution Alloy

The equiatomic NiCoCr alloy exhibits an excellent combination of strength and ductility, even greater than the FeNiCrCoMn high entropy alloy, and also displays a simultaneous increase in strength and ductility with decreasing the testing temperature. To systemically investigate the origin of the exceptional properties of NiCoCr alloy, which are related to the evolution of the deformation substructure with strain, interrupted tensile testing was conducted on the equiatomic NiCoCr single-phase solid solution alloy at both cryogenic and room temperatures at five different plastic strain levels of 1.5%, 6.5%, 29%, 50% and 70%. The evolution of deformation substructure was examined using electron backscatter diffraction (EBSD), transmission Kikuchi diffraction (TKD), conventional transmission electron microscopy (CTEM), diffraction contrast imaging using STEM (DCI-STEM) and atomic resolution scanning transmission electron microscopy. While the deformation substructure mainly consisted of planar dislocation slip and the dissociation of dislocations into stacking faults at small strain levels (≤6.5%), at larger strain levels, additional substructures including nanotwins and a new phase with hexagonal close packed (HCP) lamellae also appeared. The volume fraction of the HCP lamellae increases with increasing deformation, especially at cryogenic temperature. First principles calculations at 0 K indicate that the HCP phase is indeed energetically favorable relative to FCC for this composition. The effects of the nanotwin and HCP lamellar structures on hardening rate and ductility at both cryogenic and room temperature are qualitatively discussed.

Twinning↗

Controllable Planar Optical Focusing System

An optical device has a first metasurface disposed over a substrate. A high-contrast pattern of the first metasurface is operable for modifying, over a first phase profile, a phase front of an incident light beam. A second metasurface, is disposed over a plane parallel to the first metasurface with a second high-contrast pattern and operable for shaping, over a second phase profile, the modified phase front of the incident light beam into a converging spherical phase front. A spacer layer, in which the modified phase front of the incident light beam diffracts, is disposed in a controllably changeable separation between the first and second metasurfaces. Controllably changing the separation between the first and the second metasurfaces by a first distance correspondingly changes the position of the focus point of the converging spherical phase front by a second distance significantly greater than the first distance.

Arbabi, Amir↗

Requirements and Technology Advances for Global Wind Measurement with a Coherent Lidar: A Shrinking Gap

Early concepts to globally measure vertical profiles of vector horizontal wind from space planned on an orbit height of 525 km, a single pulsed coherent Doppler lidar system to cover the full troposphere, and a continuously rotating telescope/scanner that mandated a vertical line of sight wind profile from each laser shot. Under these conditions system studies found that laser pulse energies of approximately 20 J at 10 Hz pulse repetition rate with a rotating telescope diameter of approximately 1.5 m was required. Further requirements to use solid state laser technology and an eyesafe wavelength led to the relatively new 2-micron solid state laser. With demonstrated pulse energies near 20 mJ at 5 Hz, and no demonstration of a rotating telescope maintaining diffraction limited performance in space, the technology gap between requirements and demonstration was formidable. Fortunately the involved scientists and engineers set out to reduce the gap, and through a combination of clever ideas and technology advances over the last 15 years, they have succeeded. This paper will detail the gap reducing factors and will present the current status.

Kavaya, Michael J.↗

Faster Processing for Inverting GPS Occultation Data

A document outlines a computational method that can be incorporated into two prior methods used to invert Global Positioning System (GPS) occultation data [signal data acquired by a low-Earth-orbiting satellite as either this or the GPS satellite rises above or falls below the horizon] to obtain information on altitude-dependent properties of the atmosphere. The two prior inversion methods, known as back propagation and canonical transform, are computationally expensive because for each occultation, they involve numerical evaluation of a large number of diffraction-like spatial integrals. The present method involves an angular-spectrum-based phase-extrapolation approximation in which each data point is associated with a plane-wave component that propagates in a unique direction from the orbit of the receiving satellite to intersect a straight line tangent to the orbit at a nearby point. This approximation enables the use of fast Fourier transforms (FFTs), which apply only to data collected along a straight-line trajectory. The computation of the diffraction-like integrals in the angular-spectrum domain by use of FFTs takes only seconds, whereas previously, it took minutes.

Ao, Chi↗