Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detect and Avoid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

The Shade Avoidance Syndrome in Arabidopsis: The Antagonistic Role of Phytochrome A and B Differentiates Vegetation Proximity and Canopy Shade

Light limitation caused by dense vegetation is one of the greatest threats to plant survival in natural environments. Plants detect such neighboring vegetation as a reduction in the red to far-red ratio (R:FR) of the incoming light. The low R:FR signal, perceived by phytochromes, initiates a set of responses collectively known as the shade avoidance syndrome, intended to reduce the degree of current or future shade from neighbors by overtopping such competitors or inducing flowering to ensure seed production. At the seedling stage these responses include increased hypocotyl elongation. We have systematically analyzed the Arabidopsis seedling response and the contribution of phyA and phyB to perception of decreased R:FR, at three different levels of photosynthetically active radiation. Our results show that the shade avoidance syndrome, induced by phyB deactivation, is gradually antagonized by phyA, operating through the so-called FR-High Irradiance Response, in response to high FR levels in a range that simulates plant canopy shade. The data indicate that the R:FR signal distinguishes between the presence of proximal, but non-shading, neighbors and direct foliar shade, via a intrafamily photosensory attenuation mechanism that acts to suppress excessive reversion toward skotomorphogenic development under prolonged direct vegetation shade.

59 BASIC BIOLOGICAL SCIENCES↗

Detection of Water Hazards for Autonomous Robotic Vehicles

Four methods of detection of bodies of water are under development as means to enable autonomous robotic ground vehicles to avoid water hazards when traversing off-road terrain. The methods involve processing of digitized outputs of optoelectronic sensors aboard the vehicles. It is planned to implement these methods in hardware and software that would operate in conjunction with the hardware and software for navigation and for avoidance of solid terrain obstacles and hazards. The first method, intended for use during the day, is based on the observation that, under most off-road conditions, reflections of sky from water are easily discriminated from the adjacent terrain by their color and brightness, regardless of the weather and of the state of surface waves on the water. Accordingly, this method involves collection of color imagery by a video camera and processing of the image data by an algorithm that classifies each pixel as soil, water, or vegetation according to its color and brightness values (see figure). Among the issues that arise is the fact that in the presence of reflections of objects on the opposite shore, it is difficult to distinguish water by color and brightness alone. Another issue is that once a body of water has been identified by means of color and brightness, its boundary must be mapped for use in navigation. Techniques for addressing these issues are under investigation. The second method, which is not limited by time of day, is based on the observation that ladar returns from bodies of water are usually too weak to be detected. In this method, ladar scans of the terrain are analyzed for returns and the absence thereof. In appropriate regions, the presence of water can be inferred from the absence of returns. Under some conditions in which reflections from the bottom are detectable, ladar returns could, in principle, be used to determine depth. The third method involves the recognition of bodies of water as dark areas in short-wavelength infrared (SWIR) images. This method is based on the fact, well known among experts in remote sensing, that water bodies of any appreciable depth appear very dark in near-infrared, overhead imagery. Even under a thick layer of marine fog, SWIR illumination is present. Hence, this method may work even in the presence of clouds, though it is unlikely to work at night. Snow and ice also exhibit very strong absorption at wavelengths greater than about 1.4 m. Hence, the wavelength range of about 1.5 to 1.6 m might be useable in this method for recognizing water, snow, and ice. One notable drawback of this method is that useful look-ahead distance could be limited by surface reflections. The fourth method, intended for use at night, involves the contrast between water and terrain in thermal-infrared (medium-wavelength infrared) imagery. This method is based on the fact that at night, water is usually warmer than the adjacent terrain. Look-ahead distance could be limited in this method because, for reasons not yet fully understood, water appears to darken in the thermal infrared with increasing distance.

Matthes, Larry↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

The Completion of a Geosynchronous Earth Orbit Survey with the Eugene Stansbery-Meter Class Autonomous Telescope

The Eugene Stansbery-Meter Class Autonomous Telescope (ES-MCAT) is the primary optical sensor used by the NASA Orbital Debris Program Office (ODPO) to statistically characterize the geosynchronous Earth orbit (GEO) debris environment and support future Orbital Debris Engineering Model (ORDEM) releases. The ES-MCAT completed its first optical survey of the GEO region from 2020 to 2022. The primary goal of this survey was to autonomously collect and process GEO data with calculated photometric and astrometric uncertainties. A pointing plan was developed to provide uniform sampling within the region of interest (ROI) while accounting for predicted downtime due to insufficient observing conditions. Detections are autonomously correlated to the Space Surveillance Network (SSN) catalog to determine if objects are correlated targets (CTs) or uncorrelated targets (UCTs), the latter of which are of interest for modeling the GEO orbital debris environment. To assess the size detection sensitivity over time and monitor the general performance of the telescope’s optics and software, the optical throughput of the system and limiting magnitudes are evaluated on a routine basis. While the telescope’s ability to operate autonomously and remotely allowed for the GEO survey to continue throughout the COVID-19 pandemic, travel restrictions hampered routine cleaning of the optics during this time, and the primary mirror degraded enough to require recoating. The mirror was removed in 2022, concluding the first GEO survey. The primary mirror received a new coating designed to be more robust against the harsh environment surrounding the ES-MCAT’s location on Ascension Island, accounting for experience gained during operations over the first GEO survey. In early 2023, the recoated primary mirror was reinstalled, and the second GEO survey was initiated. The primary goal of the second GEO survey is to characterize the evolving GEO debris environment with updated optics, software, and pointing strategies while allowing for the inclusion of non-GEO regimes or those that are outside of the ROI. While the pointing method implemented in the first survey allowed for adequate coverage of the ROI over two years, it has been improved to include pointings that avoid the Moon’s position and the galactic plane to reduce software processing time and maximize the detection capabilities of fainter objects. This method also accounts for the changing weather patterns throughout the year and reduces coverage gaps in the ROI. Provided the success of the first two-year GEO survey using autonomous operations, the ODPO is actively collaborating with the United States Space Force (USSF) to make the ES-MCAT a contributing sensor to the SSN. This paper presents results from the first GEO survey including magnitude distributions and orbital parameters for CTs and UCTs. Details are provided for the automated processing pipeline and the optical system throughput for the previous and current primary mirror coatings. In addition, an updated strategy for the second GEO survey to optimize coverage over the ROI is discussed, as are preliminary results from the ongoing second survey.

Corbin Cruz↗

The Completion of a Geosynchronous Earth Orbit Survey with the Eugene Stansbery-Meter Class Autonomous Telescope

The Eugene Stansbery-Meter Class Autonomous Telescope (ES-MCAT) is the primary optical sensor used by the NASA Orbital Debris Program Office (ODPO) to statistically characterize the geosynchronous Earth orbit (GEO) debris environment and support future Orbital Debris Engineering Model (ORDEM) releases. The ES-MCAT completed its first optical survey of the GEO region from 2020 to 2022. The primary goal of this survey was to autonomously collect and process GEO data with calculated photometric and astrometric uncertainties. A pointing plan was developed to provide uniform sampling within the region of interest (ROI) while accounting for predicted downtime due to insufficient observing conditions. Detections are autonomously correlated to the Space Surveillance Network (SSN) catalog to determine if objects are correlated targets (CTs) or uncorrelated targets (UCTs), the latter of which are of interest for modeling the GEO orbital debris environment. To assess the size detection sensitivity over time and monitor the general performance of the telescope’s optics and software, the optical throughput of the system and limiting magnitudes are evaluated on a routine basis. While the telescope’s ability to operate autonomously and remotely allowed for the GEO survey to continue throughout the COVID-19 pandemic, travel restrictions hampered routine cleaning of the optics during this time, and the primary mirror degraded enough to require recoating. The mirror was removed in 2022, concluding the first GEO survey. The primary mirror received a new coating designed to be more robust against the harsh environment surrounding the ES-MCAT’s location on Ascension Island, accounting for experience gained during operations over the first GEO survey. In early 2023, the recoated primary mirror was reinstalled, and the second GEO survey was initiated. The primary goal of the second GEO survey is to characterize the evolving GEO debris environment with updated optics, software, and pointing strategies while allowing for the inclusion of non-GEO regimes or those that are outside of the ROI. While the pointing method implemented in the first survey allowed for adequate coverage of the ROI over two years, it has been improved to include pointings that avoid the Moon’s position and the galactic plane to reduce software processing time and maximize the detection capabilities of fainter objects. This method also accounts for the changing weather patterns throughout the year and reduces coverage gaps in the ROI. Provided the success of the first two-year GEO survey using autonomous operations, the ODPO is actively collaborating with the United States Space Force (USSF) to make the ES-MCAT a contributing sensor to the SSN. This paper presents results from the first GEO survey including magnitude distributions and orbital parameters for CTs and UCTs. Details are provided for the automated processing pipeline and the optical system throughput for the previous and current primary mirror coatings. In addition, an updated strategy for the second GEO survey to optimize coverage over the ROI is discussed, as are preliminary results from the ongoing second survey.

Corbin Cruz↗

Terrestrial Gamma-ray Flash (TGF) Observations with the Gamma-ray Burst Monitor on the Fermi Observatory

Terrestrial Gamma-ray Flashes (TGFs) have now been detected with four different orbiting spacecraft. The latest observations are being made with the scintillation detectors of Gamma-ray Burst Monitor (GBM) on the Fermi Gamma-ray Space Telescope Observatory (Fermi). Although this experiment was designed and optimized for the observation of cosmic gamma-ray bursts (GRBs), it has unprecedented capabilities for TGF observations, surpassing those of the experiment that discovered TGFs, the BATSE experiment on the Compton Gamma-ray Observatory. Launched in June 2008 from the Kennedy Space Center, the Fermi-GBM has been detecting about one TGF every four weeks. The thick bismuth germinate (BGO) scintillation detectors of the GBM have now observed photon energies from TGFs at energies up to approx.40 MeV. Individual photons are detected with an absolute timing accuracy of 2 microsec. Unlike the BATSE instrument, the GBM data system allows higher counting rates to be recorded and deadtime characteristics are well-known and correctable; thus the saturation effects seen with BATSE are avoided. TGF pulses as narrow as approx.0.1ms have been observed with the GBM. Like BATSE (and unlike RHESSI) an on-board trigger is required to detect TGFs. The minimum time window for this trigger is 16ms. A trigger window this wide greatly reduces the number of detected TGFs, since they most often have a much shorter duration than this window, thus reducing the signal-to-background. New on-board trigger algorithms based on detected photon energies are about to be implemented; this should increase the number of TGF triggers. High-energy spectra from TGFs observed with Fermi-GBM will be described.

Fishman, Gerald J.↗

Insights into the Enhanced Reversibility of Graphite Anode Upon Fast Charging Through Li Reservoir

Increasing the charging rate and reducing the charging time for Li-ion batteries are crucial to realize the mainstream of electric vehicles. However, it is formidable to avoid the Li plating on graphite anode upon fast charging. Despite the tremendous progress in Li detection techniques, the fundamental mechanism of Li plating and its chemical/electrochemical responses upon cycling still remains elusive. Herein, we present a comprehensive electrochemical method to investigate the fast charging behavior of graphite electrode. A detailed analysis is directed toward understanding the changes in phase, composition, and morphology of the fast-charged graphite. By applying a resting process, we scrutinize the further reactions of the plated Li, which readily transforms into irreversible (dead) Li. We further develop a modified graphite electrode with a thin Ag coating as the Li reservoir. The plated Li can be "absorbed" by the Ag layer to form the Li-Ag solid solution that suppresses the formation of dead Li and provides structural stability, thus promoting the further lithiation of graphite and enhancing the reversibility. Here this work not only provides additional insights into the fast charging behavior of graphite electrode but also demonstrates a potential strategy to improve the fast charging performance of graphite anode.

25 ENERGY STORAGE↗

SU-G-BRB-06: Commissioning and Evaluation of EPID-Based in Vivo Dosimetry Software Using a Tissue-Maximum Ratio Approach

Purpose: To commission and evaluate an in vivo EPID-based transit dosimetry software (EPIgray, DOSIsoft, Cachan, France) using simple fields and TG119-based IMRT treatment plans. Methods: EPIgray was commissioned on a Truebeam based on finite tissue-maximum ratio (fTMR) measurements with solid water blocks of thicknesses between 0 and 37 cm. Field sizes varied from 2×2 to 20×20 cm{sup 2}. Subsequently, treatment plans of single and opposed beams with field sizes between 4×4 and 15×15 cm{sup 2} as well as IMRT plans were measured to evaluate the dose reconstruction accuracy. Single field dose predictions were made for anterior-posterior and lateral beams. IMRT plans were created based on TG119 recommendations. The reconstructed dose was compared to the planned dose for selected points at isocenter and away from isocenter. Results: For single square fields, the dose in EPIgray was reconstructed within 3% accuracy at isocenter relative to the planned dose. Similarly, the relative deviation of the total dose was accurately reconstructed within 3% for all IMRT plans with points placed inside a high dose region near the isocenter. Predictions became less accurate than 5% when the evaluation point was outside the majority of IMRT beam segments. Additionally, points 5 cm or more away from the isocenter or within an avoidance structure were predicted less reliably. Conclusion: EPIgray formalism accuracy is adequate for an efficient error detection system. It provides immediate intra-fractional feedback on the delivery of treatment plans without affecting the treatment beam. Besides the EPID, no additional hardware is required, which makes it accessible to all clinics. The software evaluates point dose measurements to verify treatment plan delivery and patient positioning within 5% accuracy, depending on the placement of evaluation points. EPIgray is not intended to replace patient-specific quality assurance but should be utilized as an additional layer of safety for continuous patient treatment verification. This research is supported by DOSIsoft.

60 APPLIED LIFE SCIENCES↗

Feature-based Anomaly Detection System

SAND2022-7963 O The Feature-Based Anomaly Detection System detects anomalies in video data based on features derived from pre-trained image models to avoid the need for training. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Hannasch, David↗

Kinetics of the gas-phase reaction between hydroxyl and carbonyl sulfide over the temperature range 300-517 K

By use of a discharge-flow resonance-fluorescence method the rate constant for the title reaction has been measured at five temperatures in the range 300-520 K. The Arrhenius expression is k(OH + OCS) = (1.3 + or - 0.3) x 10 to the -12th exp/-(2300 + or - 100)/T/ cu cm/s. Mass spectrometry has been used to detect the product HS and to collect some information about its reactivity. This study has carefully avoided the pitfalls associated with possible photolysis of reactants and complications due to H2S impurity in carbonyl sulfide that may have marred previous studies. This study has confirmed that the rate constant for this reaction is so much lower than the value originally used in computer modeling of the upper and lower atmosphere that conclusions about the relative importance of photolysis of OCS and of the reaction OH + OCS in the stratosphere must now be reassessed. The reaction OH + OCS has little significance for atmospheric chemistry.

Leu, M.-T.↗

The implementation and use of Ada on distributed systems with reliability requirements

The issues involved in the use of the programming language Ada on distributed systems are discussed. The effects of Ada programs on hardware failures such as loss of a processor are emphasized. It is shown that many Ada language elements are not well suited to this environment. Processor failure can easily lead to difficulties on those processors which remain. As an example, the calling task in a rendezvous may be suspended forever if the processor executing the serving task fails. A mechanism for detecting failure is proposed and changes to the Ada run time support system are suggested which avoid most of the difficulties. Ada program structures are defined which allow programs to reconfigure and continue to provide service following processor failure.

Reynolds, P. F.↗

0.87-micron CSP diode lasers for spaceborne communications

Index-guided channeled-substrate-planar (CSP) AlGaAs diode lasers are being developed for reliable, high-power operation for use as sources in spaceborne optical communications systems. Although most work on this AlGaAs structure has been aimed at optimizing performance at output wavelengths less than 8400 A, emission in the 8700 A regime is also of interest. In particular, such wavelengths are required for use in the direct detection laser transceiver to be incorporated into NASA's advanced communications technology satellite, in order to avoid absorption of the light by the atmosphere when communicating with ground-based terminals. Lowest order spatial mode and substantially single longitudinal mode output has been observed in 0.87-micron CSP devices in excess of 50 mW cw and 100 mW 50 percent duty-cycle, with rms phase-front aberrations measured to be about lambda/40.

Carlin, D. B.↗

Trabecular Bone Mechanical Properties and Fractal Dimension

Countermeasures for reducing bone loss and muscle atrophy due to extended exposure to the microgravity environment of space are continuing to be developed and improved. An important component of this effort is finite element modeling of the lower extremity and spinal column. These models will permit analysis and evaluation specific to each individual and thereby provide more efficient and effective exercise protocols. Inflight countermeasures and post-flight rehabilitation can then be customized and targeted on a case-by-case basis. Recent Summer Faculty Fellowship participants have focused upon finite element mesh generation, muscle force estimation, and fractal calculations of trabecular bone microstructure. Methods have been developed for generating the three-dimensional geometry of the femur from serial section magnetic resonance images (MRI). The use of MRI as an imaging modality avoids excessive exposure to radiation associated with X-ray based methods. These images can also detect trabecular bone microstructure and architecture. The goal of the current research is to determine the degree to which the fractal dimension of trabecular architecture can be used to predict the mechanical properties of trabecular bone tissue. The elastic modulus and the ultimate strength (or strain) can then be estimated from non-invasive, non-radiating imaging and incorporated into the finite element models to more accurately represent the bone tissue of each individual of interest. Trabecular bone specimens from the proximal tibia are being studied in this first phase of the work. Detailed protocols and procedures have been developed for carrying test specimens through all of the steps of a multi-faceted test program. The test program begins with MRI and X-ray imaging of the whole bones before excising a smaller workpiece from the proximal tibia region. High resolution MRI scans are then made and the piece further cut into slabs (roughly 1 cm thick). The slabs are X-rayed again and also scanned using dual-energy X-ray absorptiometry (DEXA). Cube specimens are then cut from the slabs and tested mechanically in compression. Correlations between mechanical properties and fractal dimension will then be examined to assess and quantify the predictive capability of the fractal calculations.

Hogan, Harry A.↗

NASA Tech Briefs, May 2013

Topics include: Test Waveform Applications for JPL STRS Operating Environment; Pneumatic Proboscis Heat-Flow Probe; Method to Measure Total Noise Temperature of a Wireless Receiver During Operation; Cursor Control Device Test Battery; Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex; ESD Test Apparatus for Soldering Irons; FPGA-Based X-Ray Detection and Measurement for an X-Ray Polarimeter; Sequential Probability Ratio Test for Spacecraft Collision Avoidance Maneuver Decisions; Silicon/Carbon Nanotube Photocathode for Splitting Water; Advanced Materials and Fabrication Techniques for the Orion Attitude Control Motor; Flight Hardware Packaging Design for Stringent EMC Radiated Emission Requirements; RF Reference Switch for Spaceflight Radiometer Calibration; An Offload NIC for NASA, NLR, and Grid Computing; Multi-Scale CNT-Based Reinforcing Polymer Matrix Composites for Lightweight Structures; Ceramic Adhesive and Methods for On-Orbit Repair of Re-Entry Vehicles; Self-Healing Nanocomposites for Reusable Composite Cryotanks; Pt-Ni and Pt-Co Catalyst Synthesis Route for Fuel Cell Applications; Aerogel-Based Multilayer Insulation with Micrometeoroid Protection; Manufacturing of Nanocomposite Carbon Fibers and Composite Cylinders; Optimized Radiator Geometries for Hot Lunar Thermal Environments; A Mission Concept: Re-Entry Hopper-Aero-Space-Craft System on-Mars (REARM-Mars); New Class of Flow Batteries for Terrestrial and Aerospace Energy Storage Applications; Reliability of CCGA 1152 and CCGA 1272 Interconnect Packages for Extreme Thermal Environments; Using a Blender to Assess the Microbial Density of Encapsulated Organisms; Mixed Integer Programming and Heuristic Scheduling for Space Communication; Video Altimeter and Obstruction Detector for an Aircraft; Control Software for Piezo Stepping Actuators; Galactic Cosmic Ray Event-Based Risk Model (GERM) Code; Sasquatch Footprint Tool; and Multi-User Space Link Extension (SLE) System.

Source record↗

Establishing and Monitoring an Aseptic Workspace

When are aseptic operations necessary? In order to meet certain bioburden requirements, some components must undergo dry heat microbial reduction (DHMR) or other sterilizing procedures. If sensitive surfaces must be re-exposed after DHMR, this could compromise the bioburden levels. Recontaminating sterilized surfaces could be costly both in time by requiring repeated DHMR and risk to the hardware, which may not be compatible with repeated high temperature bakes. In order to prevent recontamination of the sensitive surfaces, an aseptic environment and sterile technique must be employed. Aseptic environments mean working in a space with almost no detectable bioburden in the air or on surfaces. Ideally, DHMR happens as late as possible to avoid requiring aseptic operations, as it can be considered a high-risk operations. Preparing the cleanroom for aseptic operations Establishing an ISO (International Organization for Standardization) class 5 space to minimize airborne particles. Maintain low bioburden in the cleanroom by using biocidal cleaners. Using multiple biocidal techniques decreases the likelihood of selecting for resistant microorganisms. 70% Isopropyl Alcohol (IPA) denatures the proteins in a microorganism (note: 70% IPA is better at killing microorganisms than 100% IPA) 7% hydrogen peroxide: damages DNA and proteins through oxygen radical damage. Ultraviolet-C (UV-C) lamps: causes crosslinking in DNA which prevents replication. Monitor cleanroom regularly for bioburden trending: Standard bioassay: Swab or wipe samples of cleanroom surfaces processed for colony forming unity (viable or spore selected); Rapid bioassay: Adenosine triphosphate (ATP) or Limulus amebocyte lysate (LAL) for a bioburden snapshot. High levels can signal an immediate re-cleaning before standard bioassay samples are taken. Airborne monitoring: Active (pulling air through a filter) or passive (particle fallout) for bioburden. Verify bioburden levels just before aseptic operation. Test hardware and cleanroom surfaces and air 3 days before the planned aseptic operation. Rapid bioburden just before aseptic operation to ensure room was not re-contaminated. Preparing personnel and tools: Personnel training. Everyone in the cleanroom: Standard cleanroom certification Everyone on the team: 1 day Planetary Protection overview. Aseptic operators only: Half-day aseptic operations training. Covers sterile garmenting/gloves, Sterile handling with a focus on contact transfer risk, tool/GSE preparation, and two-operator system for opening sterilized tools/components. Tool sterilization: All tools to be used during an aseptic operation need to be identified. Compatible tools are sterilized by DHMR or Autoclave. Double wrapped so that the exterior bag can be handled by a non-sterile operator, and the sterile. Tools that are not compatible with high heat do not come in contact with sensitive surfaces: either substitutes are found, or tools are isolated by wrapping in sterile foil. During an aseptic operation. Pre-task to make sure everyone understands the operations, who is handling what, and when the most critical surfaces will be exposed. Monitoring during the operation. Bioburden: active and passive airborne bioburden sampling, glove-tip dabs onto a plate after completion of operation (3 days for results). Particles: real time particle counter constantly running, with alarm for exceeding ISO 5 conditions.

aseptic processing↗

Avoiding Selection Bias in Generating Examples of Plans in the Presence of Heuristic Error

It is generally understood that heuristic error hurts the performance of search algorithms, measured in terms of search effort. Hence there is an interest in understanding how to reduce heuristic error. One way to do this is to learn a heuristic from a set of examples of plans generated offline, e.g. bootstrapping methods. In this paper, we consider how some methods for generating examples of plans may skew the training set in the presence of heuristic errors. Initial theoretical results show that duplicate detection is one source of selection bias in the canonical A* algorithm. We introduce a duplicate selection scheme for A* that avoids selection bias in generating cost-optimal examples, without compromising memory efficiency, and develop ideas in the satisficing setting. We evaluate our approach on n x m grids with multiple cost-optimal solutions and synthetic heuristic error. Finally, we attempt to extend these ideas to the problem of generating extreme examples of plans.

Alison S Paredes↗

A Facile Approach to High Precision Detection of Cell-to-Cell Variation for Li-ion Batteries

Abstract Over the past decade, it has been repeatedly demonstrated that homogeneity in electrochemical performance of lithium-ion cells plays a major role in determining the life and safety of lithium-ion battery modules or packs. Generally, the homogeneity of a battery pack is evaluated by characterizing the cells individually in terms of capacity, mass, impedance. Particularly, high quality electrochemical data heavily relies on the availability of high precision current source to minimize the discrepancy induced by the channel-to-channel variation. Here, a facile and precise measurement method is reported for screening cell-to-cell variations, in which voltage is the only indicator parameter independent of high precision current source. In detail, by connecting the cells in series (CiS), the measurement error of electrochemical data caused by stability and discrepancy of current sources among different charge/discharge equipment can be effectively avoided. The findings of this work showed that the cell-to-cell variations can be simply and sensitively detected with CiS configuration. For example, the relative standard deviation, which is the evaluation criterion of battery homogeneity, was 2.14% based on CiS while it was 0.43% based on individual measurements. The simple and precise CiS measurement is promising for evaluation of cell quality or module integration quality. In addition, this work can also provide a solid foundation for the development of detection algorithms for battery management systems to rapidly monitor battery homogeneity.

25 ENERGY STORAGE↗

Vision-based obstacle detection for rotorcraft flight

An obstacle detection approach to rotorcraft flight is described which is based on feature tracking and recursive range estimation. Flight characteristics are taken into account. A range map derived on the basis of this approach provides an advisory display to the pilot and can serve as input to an automatic obstacle-avoidance guidance system. A NASA CH-47 Chinook helicopter was used to develop an image and rotorcraft flight data base for verification of obstacle detection concepts. The performance of the passive range estimation algorithms is demonstrated using both laboratory image and flight image data.

Sridhar, Banavar↗