Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Discriminating between a stochastic gravitational wave background and instrument noise

The detection of a stochastic background of gravitational waves could significantly impact our understanding of the physical processes that shaped the early Universe. The challenge lies in separating the cosmological signal from other stochastic processes such as instrument noise and astrophysical foregrounds. One approach is to build two or more detectors and cross correlate their output, thereby enhancing the common gravitational wave signal relative to the uncorrelated instrument noise. When only one detector is available, as will likely be the case with the Laser Interferometer Space Antenna (LISA), alternative analysis techniques must be developed. Here we show that models of the noise and signal transfer functions can be used to tease apart the gravitational and instrument noise contributions. We discuss the role of gravitational wave insensitive ''null channels'' formed from particular combinations of the time delay interferometry, and derive a new combination that maintains this insensitivity for unequal arm-length detectors. We show that, in the absence of astrophysical foregrounds, LISA could detect signals with energy densities as low as {Omega}{sub gw}=6x10{sup -13} with just one month of data. We describe an end-to-end Bayesian analysis pipeline that is able to search for, characterize and assign confidence levels for the detection of a stochastic gravitational wave background, and demonstrate the effectiveness of this approach using simulated data from the third round of Mock LISA Data Challenges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Top-Quark Pairs at High Invariant Mass: A Model-Independent Discriminator of New Physics at the Large Hadron Collider

We study top-quark pair production to probe new physics at the CERN Large Hadron Collider. We propose reconstruction methods for tt semileptonic events and use them to reconstruct the tt invariant mass. The angular distribution of top quarks in their c.m. frame can determine the spin and production subprocess for each new physics resonance. Forward-backward asymmetry and CP-odd variables can be constructed to further delineate the nature of new physics. We parametrize the new resonances with a few generic parameters and show high invariant mass top pair production may provide an early indicator for new physics beyond the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Raman spectroscopy of thermally perturbed carbon fibers: Discriminating spectral responses of modulus classes and defect types

The mechanical strength properties of carbon fibers are generally thought to be correlated with the presence of underlying atomic-level defects. These defects serve to break the underlying translational symmetry of the graphitic or graphene subunits of the fiber construction, resulting in the emergence of new Raman-active spectral features. However, historical attempts to classify the precise origin of defect contributions to the Raman spectra have been challenging because of indistinct and overlapping features in the carbon fiber Raman spectra. Further, while substantial research exists on high-temperature exposure in inert atmospheres for carbon fiber composites, comparatively less addresses microscale behaviors and Raman spectral alterations to monofilament carbon fibers exposed to high-temperature atmospheric environments. Here, we report Raman spectral responses of nine commercially available high-performance, polyacrylonitrile-based carbon fibers exposed to various atmospheric heat treatments. In this work, we introduce a model-independent characterization method, the integrated absolute difference, to quantify the spectral responses to heat treatment of different fiber modulus classes. We combine this new method with a newly reported strategy to standardize spectral fitting for carbon fibers. With this approach, we show that atomic-scale defects in the underlying fiber microstructure manifest in measurably distinct manners and have distinct responses to thermal perturbation. These combined approaches may lay the foundation for disentangling contributions from specific defects in the Raman spectra of carbon fibers.

36 MATERIALS SCIENCE↗

Detecting sub-MeV neutrons in solid plastic scintillator with gamma-ray discrimination

We report on recent efforts to design a solid plastic scintillation hodoscope to measure neutron production cross sections at low energies. Our program includes not only the development of the detector itself, but also a set of auxiliary measurements which will help characterize its low-energy response. A novel scintillation counter has been developed to detect sub-MeV neutrons while rejecting gamma-ray backgrounds with good efficiency. The detector uses multiple layers of thin solid scintillator, with optical isolation between the adjacent layers. Incident low-energy neutrons produce ionizing recoil particles which remain within just one of the scintillator layers, while background gamma rays create electrons which most often cross the boundary between layers. By observing the trigger pattern within the layers, most gamma-ray backgrounds can be distinguished from the low-energy neutrons of interest. We report on the results of our Monte Carlo studies of this design, as well as on the operation of a prototype detector unit. We also have undertaken a new measurement of the neutron-proton total cross section below 1 MeV. Calculations of the efficiency for detecting low energy neutrons in plastic scintillator rely on accurate low energy n-p cross sections, yet surprisingly few such data currently exist. New measurements which span the region from 150 to 800 keV neutron (lab) energy are reported and discussed. Additionally, we have measured the light response of BC 418 scintillator for recoil proton energies as low as 100 keV. Recoil protons are produced at a known energy in the scintillator by placing it in a neutron beam and detecting in coincidence the elastically scattered neutrons at fixed angle. Our new results extend the energy range of previous measurements of the light response of solid organic scintillators, and may indicate a significantly modified response at the lowest observed energies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-10 Doped Polysiloxanes as Matrix Materials for Application in the Simultaneous Detection and Discrimination of Gamma Rays and Fast and Thermal Neutrons

Three boron-10 enriched aromatic molecules have been synthesized and incorporated into two different commercial polysiloxane resins, Shin Etsu KER-6000 and Wacker SilRes H62-C. Scintillating fluorophores, 9,9-dimethyl-2-phenylfluorene (PhF) and 2,5-diphenyloxazole (PPO), were tested in combination with each resin and boron-10 molecule for the simultaneous detection of gamma rays, fast neutrons, and thermal neutrons. Here, the H62-C resin was able to solubilize a large amount of PhF, in excess of 20 wt%. Cure kinetics were controlled through the addition of divinylbenzene and phenyl tris(dimethylsiloxy)silane cross-linker solution to the H62-C resin, with rheology experiments demonstrating a large reduction in time to gelation when 20 wt% cross-linker solution was added, from more than 4 hours to less than 1 hour. These polysiloxane resins can be cured in 3 hours under air, while common poly(vinyltoluene) scintillators require at least 4 days of heating and oxygen-free conditions. PhF-doped KER-6000 with tolyl boronate pinacol ester exhibited the best overall performance with a light yield of 62% relative to EJ-200 and thermal neutron capture at energies up to 103 keVee (84 keVee for EJ254B-5). Additionally, four samples exhibited light yields surpassing an industry-standard boron-doped plastic scintillator, Eljen’s EJ254B-5. Over the course of ten months, the KER-6000 samples showed precipitation of dopant molecules, which reduced their light yield by 15% on average, while H62-C proved to be more stable with only a 6% reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Avoiding the False Peaks in Correlation Discrimination

Fiducials imprinted on laser beams are used to perform video image based alignment of the 192 laser beams in the National Ignition Facility (NIF) of Lawrence Livermore National Laboratory. In many video images, matched filtering is used to detect the location of these fiducials. Generally, the highest correlation peak is used to determine the position of the fiducials. However, when the signal to-be-detected is very weak compared to the noise, this approach totally breaks down. The highest peaks act as traps for false detection. The active target images used for automatic alignment in the National Ignition Facility are examples of such images. In these images, the fiducials of interest exhibit extremely low intensity and contrast, surrounded by high intensity reflection from metallic objects. Consequently, the highest correlation peaks are caused by these bright objects. In this work, we show how the shape of the correlation is exploited to isolate the valid matches from hundreds of invalid correlation peaks, and therefore identify extremely faint fiducials under very challenging imaging conditions.

42 ENGINEERING↗

Infrared Signatures to Discriminate Viability of Autoclaved Bacillus Spores

Optical methods can offer good sensitivity for detecting small amounts of chemicals and biologicals, and as these methods mature, are some of the few techniques that can offer true standoff detection. For detection of biological species, determining the viability is clearly important: Certain species of gram-positive bacteria are capable of forming endospores, specialized structures that arise when living conditions become unfavorable or little growth medium is available, being resistant to many chemicals as well as changes in heat or pH. Such spores can remain dormant from months to years until more favorable conditions arise, resulting in germination back to the vegetative state. This persistence characteristic of bacterial spores allows for contamination of a surface (e.g. food or medical equipment) even after the surface has been nominally cleaned. Bacterial spores have also been used as biological weapons, as in the case with B. anthracis. Thus, rapid analysis to determine a spore's viability in a given environment or after attempts to sterilize a given environment is crucial. The increasing availability of portable spectrometers may provide a key to such rapid onsite analysis. The present study was designed to determine whether infrared spectroscopy may be used to differentiate between viable vs. dead B. subtilis and B. atrophaeus spores. Preliminary results show that the reproducible differences in the IR signatures can be used to identify viable vs. autoclaved (dead) B. subtilis and B. atrophaeus bacterial spores.

Schneider, Matthew D↗