Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Highly efficient photon detection systems for noble liquid detectors based on perovskite quantum dots

Abstract Wavelength shifting photon detection systems (PDS) are the critical functioning components in noble liquid detectors used for high energy physics (HEP) experiments and dark matter search. The vacuum ultraviolet (VUV) scintillation light emitted by these Liquid argon (LAr) and liquid Xenon (LXe) detectors are shifted to higher wavelengths resulting in its efficient detection using the state-of-the-art photodetectors such as silicon photomultipliers (SiPM). The currently used organic wavelength shifting materials [such as 1,1,4,4 Tetraphenyl Butadiene (TPB)] have several disadvantages and are unreliable for longterm use. In this study, we demonstrate the application of the inorganic perovskite cesium lead bromide (CsPbBr 3 ) quantum dots (QDs) as highly efficient wavelength shifters. The absolute photoluminescence quantum yield of the PDS fabricated using these QDs exceeds 70%. CsPbBr 3 -based PDS demonstrated an enhancement in the SiPM signal enhancement by up to 3 times when compared to a 3 µm-thick TPB-based PDS. The emission spectrum from the QDs was optimized to match the highest quantum efficiency region of the SiPMs. In addition, we have demonstrated the deposition of the QD-based wavelength shifting material on a large area PDS substrate using low capital cost and widely scalable solution-based techniques providing a pathway appropriate for meter-scale PDS fabrication and widespread use for other wavelength shifting applications.

47 OTHER INSTRUMENTATION↗

Recent Measurement of Flavor Asymmetry of Antiquarks in the Proton by Drell–Yan Experiment SeaQuest at Fermilab

A measurement of the flavor asymmetry of the antiquarks ($\bar{d}$ and $\bar{u}$) in the proton is described in this thesis. The proton consists of three valence quarks, sea quarks, and gluons. Antiquarks in the proton are sea quarks. They are generated from the gluon splitting: g → q + $\bar{q}$. According to QCD (Quantum Chromodynamics), the gluon splitting is independent of quark flavor. It suggests that the amounts of $\bar{d}$ and $\bar{u}$ should be the same in the proton. However, the NMC experiment at CERN found that the amount of $\bar{d}$ is larger than that of $\bar{u}$ in the proton using the deep inelastic scattering in 1991. This result is obtained for $\bar{d}$ and $\bar{u}$ integrated over Bjorken x. Bjorken x is the fraction of the momentum of the parton to that of the proton. The NA51 experiment (x ~ 0.2) at CERN and E866/NuSea experiment (0.015 < x < 0.35) at Fermilab measured the flavor asymmetry of the antiquarks ($\bar{d}$/$\bar{u}$) in the proton as a function of x using Drell–Yan process. The experiments reported that the flavor symmetry is broken over all measured x values. Understanding the flavor asymmetry of the antiquarks in the proton is a challenge of the QCD. The theo- retical investigation from the first principle of QCD such as lattice QCD calculation is important. In addition, the QCD effective models and hadron models such as the meson cloud model can also be tested with the flavor asymmetry of antiquarks. From the experimental side, it is important to measure with higher accuracy and in a wider x range. The SeaQuest (E906) experiment measures $\bar{d}$/$\bar{u}$ at large x (0.15 < x < 0.45) accurately to understand its behavior. The SeaQuest experiment is a Drell–Yan experiment at Fermi National Accelerator Laboratory (Fermilab). In the Drell–Yan process of proton-proton reaction, an antiquark in a proton and a quark in another proton annihilate and create a virtual photon, which then decays into a muon pair (q$\bar{q}$ → γ* → µ + µ - ). The SeaQuest experiment uses a 120 GeV proton beam extracted from Fermilab’s Main Injector. The proton beam interacts with hydrogen and deuterium targets. The SeaQuest spectrometer detects the muon pairs from the Drell–Yan process. The $\bar{d}$/$\bar{u}$ ratio at 0.1 < x < 0.58 is extracted from the number of detected Drell–Yan muon pairs. After the detector construction, commissioning run and detector upgrade, the SeaQuest experiment started the physics data acquisition from 2013. We finished so far three periods of physics data acquisition. The fourth period is in progress. The detector construction, detector performance evaluation, data taking and data analysis for the flavor asymmetry of the antiquarks $\bar{d}$/$\bar{u}$ in the proton are my contribution to SeaQuest. The cross section ratio of Drell–Yan process in p- p and p-d reactions is obtained from dimuon yields. In the experiment with high beam intensity, it is important to control the tracking efficiency of charged particles through the magnetic spectrometer. The tracking efficiency depends on the chamber occupancy, and the appropriate method for the correction is important. The chamber occupancy is the number of hits in drift chambers. A new method of the correction for the tracking efficiency is developed based on the occupancy, and applied to the data. This method reflects the real response of the drift chambers. Therefore, the systematic error is well controlled by this method. The flavor asymmetry of antiquarks is obtained at 0.1 < x < 0.58. At 0.1 < x < 0.45, the result is $\bar{d}$/$\bar{u}$ > 1. The result at 0.1 < x < 0.24 agrees with the E866 result. The result at x > 0.24, however, disagrees with the E866 result. The result at 0.45 < x < 0 the statistical errors. u¯ results extracted from experiments are used to investigate the validity of the theoretical models. The present experimental result provides the data points in wide x region. It is useful for understanding the proton structure in the light of QCD and effective hadron models. The present result has a practical application as well. Antiquark distributions are important as inputs to simulations of hadron reactions such as W± production in various experiments. The new knowledge on antiquark distributions helps to improve the precision of the simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Materials for Gamma Radiation Sensors

Sensors used for spectroscopic measurements of gamma radiation are most often scintillator or semiconductor materials. An overview is provided in this chapter on the materials and development techniques used in producing spectroscopic gamma radiation sensors. Challenges that prevent a perfect sensor are discussed along with the reasons why some sensor materials are ubiquitous despite their performance limitations. The types of sensors commonly used as detectors are discussed along with their key physical properties and electronic characteristics. Materials commonly utilized in radiation detectors are then reviewed to highlight how sensor materials have advanced since the earliest gamma detectors were developed

Johns, Paul M.↗

Pyroelectric Materials for Uncooled Infrared Detectors: Processing, Properties, and Applications

Uncooled pyroelectric detectors find applications in diverse and wide areas such as industrial production; automotive; aerospace applications for satellite-borne ozone sensors assembled with an infrared spectrometer; health care; space exploration; imaging systems for ships, cars, and aircraft; and military and security surveillance systems. These detectors are the prime candidates for NASA s thermal infrared detector requirements. In this Technical Memorandum, the physical phenomena underlying the operation and advantages of pyroelectric infrared detectors is introduced. A list and applications of important ferroelectrics is given, which is a subclass of pyroelectrics. The basic concepts of processing of important pyroelectrics in various forms are described: single crystal growth, ceramic processing, polymer-composites preparation, and thin- and thick-film fabrications. The present status of materials and their characteristics and detectors figures-of-merit are presented in detail. In the end, the unique techniques demonstrated for improving/enhancing the performance of pyroelectric detectors are illustrated. Emphasis is placed on recent advances and emerging technologies such as thin-film array devices and novel single crystal sensors.

Aggarwal, M. D.↗

Signal processing to reduce dark noise impact in precision timing

We introduce a technique to mitigate the effects of low frequency noise on precision timing. The example of Dark Count Noise Rate (DCR) in Silicon Photomultipliers (SiPMs) is emphasized. This technique exploits the correlation between time shifts on the leading edge of a signal and the residual slope of the baseline (due to noise) which remains after baseline subtraction. In fast timing applications (such as for Time-of-flight particle ID) the signal arrival time is typically captured on the signal leading edge. The signal risetime is often fixed by the physics of the sensor and input circuit. Then accurate pulse timing can be achieved by correcting a leading edge threshold time (depending on a slope proportional to both the Amplitude and the risetime) to a “constant fraction” time. This compensation for time walk due to amplitude fluctuations breaks down once we introduce interference from low frequency noise on the leading edge. In this paper we demonstrate that an additional measurement of the slope at threshold can be used to correct for this noise jitter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PandAna: A Python Analysis Framework for Scalable High Performance Computing in High Energy Physics

Modern experiments in high energy physics analyze millions of events recorded in particle detectors to select the events of interest and make measurements of physics parameters. These data can often be stored as tabular data in files with detector information and reconstructed quantities. Current techniques for event selection in these files lack the scalability needed for high performance computing environments. We describe our work to develop a high energy physics analysis framework suitable for high performance computing. This new framework utilizes modern tools for reading files and implicit data parallelism. Framework users analyze tabular data using standard, easy-to-use data analysis techniques in Python while the framework handles the file manipulations and parallelism without the user needing advanced experience in parallel programming. In future versions, we hope to provide a framework that can be utilized on a personal computer or a high performance computing cluster with little change to the user code.

Groh, Micah↗

Belle II Detector: status and proposed US contributions

Conference proceedings for the 2012 American Physical Society, Division of Particles and Fields (DPF2012) conference. Paper is on the US contibutions to the Belle II detector upgrade. High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector and upgraded KEKB accelerator. The status of the Belle II detector and proposed role of the US Belle II collaborators are presented in this article. The B factory experiments, Belle at the KEKB collider at KEK and BaBar at the PEP II collider at SLAC, were built to measure the large mixing-induced CP violation in the B0 system predicted by the theory of Kobayashi and Maskawa. The successful confirmation of the prediction led to the Nobel Prize for both theorists. The B factories were built to answer the question Is the CKM description in the Standard Model correct? Most B factory results are in good agreement with the expectations from the Standard Model (SM) and confirm the CKM structure of quark mixing and CP violation, but some measurements show tensions with the SM prediction. The Super B factories will address the question In what way is the Standard Model wrong? Much larger datasets are needed for high-precision measurements to search for significant deviations from the SM which are expected to exist. The SuperKEKB and Belle II detector are being constructed to perform these high precision studies with a dataset 50ab{sup -1}. The SuperKEKB accelerator will operate at an instantaneous luminosity of 8 x 10{sup 35}cm{sup -2}s{sup -1}, a factor of 40 times higher than the luminosity of the KEKB accelerator at the end of the Belle physics program. The increased luminosity will derive primarily from shrinking the beam size at the interaction point (nano beams) utilizing new final focus quadrapole magnets in combination with a factor of 2 increase in beam currents. To counteract the increase in the beam-beam parameter due to the reduced beta functions, the beam emittance must also be reduced; this will be achieved with a new electron source and a new damping ring.

43 PARTICLE ACCELERATORS↗

Ring resonator with integrated detector for monitoring light comprising an annular detection region that is physically isolated from a waveguide core

Examples described herein relate to a ring resonator. The ring resonator may include an annular waveguide having a waveguide base and a waveguide core narrower than the waveguide base. Further, the ring resonator may include an outer contact region comprising a first-type doping and disposed annularly and at least partially surrounding an outer annular surface of the waveguide base. Furthermore, the ring resonator may include an inner contact region comprising a second-type doping and disposed annularly contacting an inner annular surface of the waveguide base. Moreover, the ring resonator may include an annular detector region disposed annularly at a distance from and covering at least a portion of a surface of the waveguide core and contacting the outer contact region.

Yuan, Yuan↗

Search for New Physics with Top and Bottom Quarks with ATLAS

The studies performed by the principal investigator during the period of the grant constitute the ground work for search for new physics in channels including top and bottom quarks with the ATLAS detector at the Large Hadron Collider. The PI has been involved in search for heavy charged Higgs bosons decaying into top and bottom quark pairs, and top quark rare decays involving Higgs bosons and c -quarks. Both channels have the top quark pair production as their main background, which was studied in detail. The search for heavy charged Higgs and top quark rare decays requires significant amount of data accumulated by the experiment. In case no signal is observed in the present data sample collected by ATLAS (5 fb -1 of integrated luminosity at proton-anti proton center-of-mass energy of 7 TeV and 20 fb -1 at 8 TeV), data from the upgraded detector running at 14 TeV needs to be analyzed. The PI has been working on physics and performance studies at upgraded detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon-neutrino disappearance with multiple liquid argon time projection chambers in the Fermilab Booster neutrino beam

The Short Baseline Neutrino (SBN) program consists of three liquid argon time projection chamber (LArTPC) experiments: SBND, MicroBooNE and ICARUS, with 110 m, 470 m and 600 m baselines respectively. The detectors are located in the Booster Neutrino Beam (BNB) at Fermilab which has a peak energy around 0.7 GeV and contains predominantly muon neutrinos. The baseline and energy range of the SBN program is conducive to measuring neutrino oscillation parameters under various sterile neutrino hypotheses. Sterile neutrinos have been proposed as a possible solution to the numerous short baseline anomalies. The proposed particles must be sterile in nature such that they do not interact via the weak force, however they may undergo oscillations with the active neutrino flavours. Their existence may consequently be confirmed through measurements of the appearance and disappearance of the active flavours. The analyses presented in this thesis aimed to calculate and understand the sensitivity of the SBN program to measuring the ?µ disappearance parameters under the (3+1) sterile neutrino oscillation hypothesis. The sensitivity of SBN to measuring the ?µ disappearance sterile oscillation parameters, sin2 2?µµ, ?m2 41, was calculated through semi-exclusive joint fits of the ?µ CC 0p and ?µ CC Other reconstructed neutrino energy spectra. The first iteration used truth-level Monte Carlo (MC) events, and determined that the 5s SBN sensitivity is comparable to the 90% MINOS/MINOS+ confidence level and supersedes the 90% MiniBooNE confidence level across entire phase space. Semi-exclusive joint fits of the aforementioned sample spectra were performed between the MC and multiple mock data sets in SBND. This analysis assessed the accuracy with which the near detector can disentangle systematic from physics effects in the oscillation analysis. The result was a 5.49% discrepancy between the ICARUS Monte Carlo and mock data event rates, when the systematic constraints from the near detector fit were extrapolated to the far detector. The second iteration of the SBN sensitivity analysis involved the application of an event selection procedure developed in SBND, following the full reconstruction chain. ?µ CC 0p events were selected from sample of neutrinos with 84.5% efficiency and 84.3% purity. The sterile neutrino sensitivity was determined once more at the near detector with these samples, and was shown to be consistent with the truth-level studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise propagation effects in power supply distribution systems for high-energy physics experiments

High-energy physics experiments are supplied by thousands of power supply units placed in distant areas from the front-end electronics. The power supply units and the front-end electronics are connected through long power cables that propagate the output noise from the power supplies to the detector. Here, this paper addresses the effect of long cables on the noise propagation and the impact that those cables have on the conducted emission levels required for the power supplies and the selection of EMI filters for the front-end electronic low-voltage input. Lastly, this analysis is part of the electromagnetic compatibility based design focused on functional safety to define the type of cable, shield connections, EMI filters and power supply specifications required to ensure the successful integration of the detector and, specifically, to achieve the designed performance of the front-end electronics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics Opportunities in the ORNL Spallation Neutron Source Second Target Station Era

The Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) First Target Station (FTS), used by the COHERENT experiment, provides an intense and extremely high-quality source of pulsed stopped-pion neutrinos, with energies up to about 50 MeV. Upgrades to the SNS are planned, including a Second Target Station (STS), which will approximately double the expected neutrino flux while maintaining quality similar to the FTS source. Furthermore, additional space for ten-tonne scale detectors may be available. We describe here exciting opportunities for neutrino physics, other particle and nuclear physics, and detector development using the FTS and STS neutrino sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

India-based neutrino observatory (INO): Physics reach and status report

We present a review of the physics reach and current status of the proposed India-based Neutrino Observatory (INO). We briefly outline details of the INO location and the present status of detector development. We then present the physics goals and simulation studies of the main detector, the magnetised Iron Calorimeter (ICAL) detector, to be housed in INO. The ICAL detector would make precision measurements of neutrino oscillation parameters with atmospheric neutrinos including a measurement of the neutrino mass hierarchy. Additional synergies with other experiments due to the complete insensitivity of ICAL to the CP phase are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SNO+: Physics program and status update

Joining the current generation of neutrinoless double beta decay experiments, SNO+ is a kilotonne-scale liquid scintillator neutrino detector housed 2 km underground in Vale Canada Ltd’s Creighton Mine near Sudbury, Ontario, Canada. Through re-purposing existing hardware in place for the now decommissioned Sudbury Neutrino Observatory (SNO), and employing a rigourous materials purification and selection program, SNO+ will investigate neutrinoless double beta decay of {sup 130}Te. Owing to its size, SNO+ expects a sensitivity to the effective Majorana neutrino mass near 100 meV with a 0.3% loading of natural Te and several years of data collection. Designed as a general purpose detector, SNO+ also has a robust physics program that includes investigations of solar and supernova neutrinos, and reactor and geo anti-neutrinos. Construction of the detector is nearly complete, with the first water-fill commissioning phase set to begin at the end of this year and the neutrinoless double beta decay phase following in late 2014.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for pairs of scalar leptoquarks decaying into quarks and electrons or muons in $ \sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector

A search for new-physics resonances decaying into a lepton and a jet performed by the ATLAS experiment is presented. Scalar leptoquarks pair-produced in pp collisions at s = 13 TeV at the Large Hadron Collider are considered using an integrated luminosity of 139 fb-1, corresponding to the full Run 2 dataset. They are searched for in events with two electrons or two muons and two or more jets, including jets identified as arising from the fragmentation of c- or b-quarks. The observed yield in each channel is consistent with the Standard Model background expectation. Leptoquarks with masses below 1.8 TeV and 1.7 TeV are excluded in the electron and muon channels, respectively, assuming a branching ratio into a charged lepton and a quark of 100%, with minimal dependence on the quark flavour. Upper limits on the aforementioned branching ratio are also given as a function of the leptoquark mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗