Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Simulation-based assessment of ASHRAE Guideline 36, considering energy performance, indoor air quality, and control stability

This study assesses American Society of Heating, Refrigerating and Air-Conditioning Engineers Guideline 36 (G36) with a typical medium office building. Specifically, this study employed a Modelica model of a variable air volume (VAV) system that serves this building, which includes components for representing indoor virus transmission and filtration. It then implemented the G36 control sequences for both water-side and air-side equipment in Python. After that, this study conducted the assessment by co-simulating G36 and the Modelica model using the Building Operations Testing Framework. Unlike existing works, this work has three unique features: (1) It considers the interactions between control sequences for water-side and air-side equipment of the studied VAV system. (2) It assesses the performance of G36 from the perspective of IAQ. (3) It examines the short-term behaviors of the studied building under G36 to understand the control stability. This assessment confirms significant energy savings from G36, largely because of the interaction between supply air temperature and hot water controls. It also reveals a trade-off between the ability to slow the spread of virus and the energy performance via demand controlled ventilation. Lastly, it emphasizes the necessity of tuning local feedback control when implementing G36.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

Plasma shape and position control development for NSTX-U using the GSEvolve plasma simulator

NSTX-U discharges have been reproduced using the GSEvolve plasma simulator in order to improve their control and reduce oscillations during the plasma current (Ip) ramp-up phase, and with the ultimate goal of enabling reliable H-mode access with a double-null shape at high elongation, low internal inductance, and high plasma performance. The control objective is to eliminate undesired oscillations in the plasma shape and vertical position that start when the plasma diverts during the Ip ramp-up phase, and that happened recurrently during the first NSTX-U experimental campaign. Model-based control solutions have been developed, including alternative H-mode access recipes and a Multi-Input Multi-Output (MIMO) decoupling controller. These solutions have demonstrated their capability to reduce or eliminate the aforementioned oscillations in GSEvolve simulations, enabling reproducible H-mode access. The results of this work aim to inform NSTX-U experimental operations on potential control developments to maximize its scientific output, and highlight the powerful capabilities of high-fidelity control-simulation frameworks like GSEvolve.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coordinated Wind Power Plant and Battery Control for Active Power Services

This article considers joint active power control of wind turbines and battery storage to follow a plant-level power reference signal. The joint control dynamically curtails the energy from a subset of the wind turbines and stores or withdraws energy from the battery to meet the power reference setpoint while accounting for wind plant aerodynamic interactions, such as wake losses. As a use case, we study the performance of the controller in maintaining a constant power output over hourly periods. A wind plant operating in this way would rely much less on other grid resources to meet its contractual agreements, thereby improving grid reliability, especially in grids with high penetration of wind and solar generation. We compare the operation of the wind plant under joint active power control to standard power-maximizing control with battery support. We present an analysis of the performance of the control system architecture. To study the impact of the battery size on performance, we simulate a 50-MW wind plant supported by batteries ranging from 8 to 64?MWh. We then evaluate the over and undergeneration penalties incurred by the plant during the simulation period.

17 WIND ENERGY↗

Development and Evaluation of Occupancy-Aware Model Predictive Control for Residential Building Energy Efficiency and Occupant Comfort

The residential sector accounts for 25% of global primary energy consumption. Two methods have previously been proposed to reduce residential energy use associated with the provision of occupant thermal comfort: 1. Occupancy-based HVAC control, operating systems only during confirmed occupancy, and 2. model predictive control (MPC), harnessing a mathematical model and forecasts to find optimal operating strategies. Previous studies estimate the average energy savings of the two methods individually in the range of 21% and 16%, respectively. The research presented herein was carried out to evaluate the energy savings potential in residential buildings by combining both approaches across different climates, house vintages, and occupancy patterns. Occupancy and eight different physical modalities (e.g. CO2 and VOC) data were collected from five homes for time periods of 4–9 weeks. Collected data sets were used to train occupancy prediction models suggested by an extensive literature survey of occupancy model types. The trained prediction models were combined with MPC and detailed EnergyPlus building simulation models to evaluate residential building performance in terms of annual energy savings and thermal comfort, along with discomfort exceedance metrics. Multiple home types and regions were analyzed to understand regional and climate-dependent potential. Based on actual field data, the occupancy models had a prediction inaccuracy between 8% and 35% across the investigated homes. Average occupancy for the collected data ranged from 56% to 86%, a typical range reported in the literature. Building simulations were conducted for three control scenarios: conventional thermostatic control, occupancy-based, and occupancy-based MPC. The results indicate that all advanced strategies improve upon the conventional control, with some scenarios cutting energy use in half with only occasional incurrence of discomfort. The findings indicate that occupancy-aware model predictive residential building control has the potential to drastically reduce energy use and associated emissions while maintaining occupant comfort for both new and existing buildings.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Control and Grid Support Function Evaluation for a Three-Phase Back-to-Back Modular Multilevel Converter System

This paper focuses on the evaluation of advanced inverter controls for a 500kW back-to-back (B2B), silicon carbide, multilevel modular converter (MMC) used as a direct-connected medium-voltage grid intertie. A decentralized hierarchical controller architecture for the MMC system is presented, which uses the main controller to implement higher level grid interconnection functions per the IEEE 1547–2018 standards and the local controllers to execute lower level closed-loop functionality of the MMC stages. This paper presents and elaborates on the grid functionalities are elaborated and presented. The back-to-back converter system is equipped with local controllers and their corresponding functionalities are presented. Case study results for the corresponding functionalities presented show the effectiveness of the proposed architecture. To enhance the operation capabilities of the system, a parameter update scheme has been implemented and utilized in unison with the controller.

decentralized control↗

Structural Controllability Assessment for Inverter-Based Microgrids

Enhanced inverter-based controls are considered for microgrids, which use additional actuation beyond a droop-like term. Shaping of the microgrid’s small-signal dynamics using such enhanced controls is posed as a structural controllability problem. A graph-theoretic characterization of structural controllability is obtained, in terms of the concept of zero-forcing sets.Two benchmark test systems are used to illustrate the selection of locations where enhanced controls should be applied, based on the graph-theoretic analysis. These examples indicate that small-signal characteristics can be shaped using a relatively small number of enhanced controls

microgrids, zero-forcing, structural controlabilit↗

Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

This paper presents the operational modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is briefly discussed. The case studies and real-time hardware-in-the-loop simulation results are provided using Typhoon HIL to back the theoretical investigation.

ancillary services↗

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual Representations and H ∞ -Optimal Control of Partial Differential Equations

We consider H ∞ -optimal state-feedback control of the class of linear Partial Differential Equations (PDEs) which admit a Partial Integral Equation (PIE) representation. While linear matrix inequalities are commonly used for optimal control of Ordinary Differential Equations (ODEs), the absence of a universal state-space representation and suitable dual form prevents such methods from being applied to optimal control of PDEs. Specifically, for ODEs, the controller synthesis problem is defined in state-space, and duality is used to resolve the bilinearity of that synthesis problem. Recently, the PIE representation was proposed as a universal state-space representation for linear PDE systems. In this paper, we show that any PDE system represented by a PIE admits a dual PIE with identical stability and I/O properties. This result allows us to reformulate the stabilizing and optimal state-feedback control problems as convex optimization over the cone of positive Partial Integral (PI) operators. Operator inversion formulae then allow us to construct feedback gains for the original PDE system. The results are verified through application to several canonical problems in optimal control of PDEs and indicate the resulting bounds on H ∞ norm are not conservative.

42 ENGINEERING↗

A Multiagent Deep Reinforcement Learning-Enabled Dual-Branch Damping Controller for Multimode Oscillation

Here, this study develops a multiagent deep reinforcement learning (MADRL)-enabled framework for the decentralized cooperative control of a novel dual-branch (DB) damping controller for both low-frequency oscillation (LFO) and ultralow-frequency oscillation (ULFO). It has two branches, each of which consists of a proportional resonance (PR) and a second-order polynomial that is designed to handle target oscillation modes. To improve the robustness of the controller to system uncertainties, MADRL is developed, where multiagents are centrally trained to obtain the coordinated adaptive control policy while being executed in a decentralized manner to provide the optimal parameter setting for each controller with only local states. Comparisons with the IEEE 10-machine 39-bus system demonstrate that the proposed method achieves better robustness to uncertainties, lower communication delay, and single-point failure, as well as damping control performances for both LFO and ULFO.

97 MATHEMATICS AND COMPUTING↗

EMI Mitigation of a Ćuk-Based Power-Electronic System Using Switching-Sequence-Based Control

Switching-sequence-based control (SBC) laws when designed based on topological switching behavior can have positive effects on slow- and fast-scale dynamics of a power-electronic system (PES). The slow-scale control can encompass fast PES state regulation and tracking, based on predefined objective, while fastscale control can address differential-mode (DM) and commonmode (CM) spectral-peak energy associated with PES switching operation. Such control laws may offer enhanced programmability to conventional PES design where bulky electromagnetic interference (EMI) filters have been traditionally used to reduce EMI of switching power converters to meet EMI regulatory standards. An EMI filter is always a less programmable solution since it is usually designed for the worst-case EMI mitigation and usually overkill for a PES operating under reduced load condition. The control scheme outlined in this article offers EMI mitigation across wide operating regions without compromising PES regulation. Moreover, it does so by use of switching sequences that guarantee the reachability of the PES dynamics using an advanced Lyapunov-function-based approach. SBC is a powerful tool to generate control actions for a PES based on multivariate PES state constraints. Hence, contemporary EMI regulatory standards are used as constraints in the SBC formulation to operate the PES under wide operating regime while autonomously mitigating the EMI levels. The work may be of paramount importance for operating the ultra-fast-transition recent wide-bandgap semiconductor devices like GaN–FET and SiC MOSFET under higher power with increasing switching frequencies, which is usually desirable for increased power density and reduced switching losses. Here, a hardware Cuk–PES operated ´ with GaN–FETs is fabricated and is used for case illustration. It is shown by experimental results how SBC mitigate DM and CM EMI noise of the PES while maintaining regulation even for the higher order nonminimum phase PES, while reducing sensor requirements using state observer derived from the switching model of the PES.

42 ENGINEERING↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear Multiple Models Adaptive Secondary Voltage Control of Microgrids

This article proposes a model-free secondary voltage control (SVC) for microgrids (MG) using nonlinear multiple models adaptive control. Firstly, a linear robust adaptive controller is designed to guarantee the voltage stability in the bounded-input- bounded-output (BIBO) manner so as to meet the operation requirements of MGs. Secondly, a nonlinear adaptive controller is developed to improve the voltage tracking performance with the help of artificial neural networks (ANNs). A switching mechanism for coordinating such two controllers is designed to guarantee the closed-loop stability while achieving accurate voltage tracking. Here, by an online identification based on the input and output data of MGs, the proposed method does not resort to any apriori information of system model and primary control, thus exhibiting good robustness, ease of deployment and disturbance rejection.

17 WIND ENERGY↗

Stochastic Adaptive Droop Control in Frequency Regulation of Power Systems With Intermittent Generators

Modern power systems (MPSs), including microgrids (MGs), are increasingly incorporating multiple renewable energy sources (RESs) such as wind and solar power, as well as battery storage and controllable loads. While environmentally beneficial, these sources pose challenges for control and management due to their intermittent and stochastic nature, especially in maintaining frequency stability with multiple interconnected generators of varying capacities. Traditional droop control methods are effective in systems with generators that are dispatchable and have fixed generation capacities, but they fall short when applied to systems with RESs, where generation capacities are dynamic and affected by unpredictable environmental conditions. To address these challenges, this paper introduces a novel stochastic adaptive droop control (SADC) method for load frequency control (LFC). The proposed method adapts droop coefficients in real time, based on the measured stochastic data of power generation capacities, enabling more effective frequency regulation in systems with variable and intermittent power generation. Unlike traditional adaptive control methods, which assume constant or slowly-varying system parameters, this approach accounts for stochastic processes by modeling them as Markov chains, enabling robust performance under highly dynamic and unpredictable conditions. The key contributions of this work include the development of real-time droop coefficient adaptation algorithms, derivation of their stability and convergence properties, and the demonstration of the advantages of the method through simulations. Case studies highlight the improved performance of frequency regulation, particularly in addressing the impact of stochastic weather conditions and the benefits of reducing dependence on battery reserves in dealing with intermittency of RESs. Finally, this paper provides a comprehensive analysis of the theoretical foundations of the method, as well as practical implementation insights for future power systems with high penetration of RESs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling Interoperable SCADA Communications for PV Inverters through Embedded Controllers

The percentage integration of photovoltaic (PV) inverters in the field has increased significantly in the past 5 years. Regardless of the size of the PV plants and the inverters (residential vs. commercial), it is becoming crucial that these devices have the capability to communicate with peers (other smart devices) and with components that are at a hierarchy above the inverters (e.g., supervisory control and data acquisition (SCADA) systems, distributed controllers, and data managers). This project aims to develop a standard SCADA software code for inverters’ embedded controllers that will enable interoperability with other components in the system. To achieve this, the code will be developed using two different protocols: Distributed Network Protocol 3 and International Electrotechnical Commission 61850. The developed code is aimed to be deployed in simple embedded controllers. It will be tested in the National Renewable Energy Laboratory’s (NREL’s) Energy Systems Integration Facility. The tested code will then be made available through Triangle MicroWorks’s (TMW’s) software platform. The primary objectives of this project include training the NREL team with TMW’s embedded controller libraries, developing an interoperable communication code for embedded controllers, successfully testing and deploying the code, and demonstrating the newly developed code in a conference.

14 SOLAR ENERGY↗