Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Conditional Normalizing Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Effect of tabs on the flow and noise field of an axisymmetric jet

The effect of vortex generators, in the form of small tabs projecting normally into the flow at the nozzle exit, on the characteristics of an axisymmetric jet is investigated experimentally over the jet Mach number range of 0.3-1.81. The tabs eliminate screech noise from supersonic jets and alter the shock structure drastically. They distort the jet cross section and increase the jet spread rate significantly. The distortion produced is essentially the same at subsonic and underexpanded supersonic conditions. Thus, the underlying mechanism must be independent of compressibility effects. A tab with a height as small as 2 percent of the jet diameter, but larger than the efflux boundary-layer thickness, is found to produce a significant effect. Flow visualization reveals that each tab introduces an 'indentation' into the high speed side of the shear layer via the action of streamwise vortices. These vortices are inferred to be of the 'trailing vortex' type rather than of the 'necklace vortex' type. It is apparent that a substantial pressure differential must exist between the upstream and the downstream sides of the tab to effectively produce these trailing vortices. This explains why the tabs are ineffective in the overexpanded flow, as in that case an adverse pressure gradient exists near the nozzle exit which reduces the pressure differential produced by the tab.

Samimy, M.↗

Process for Study of Micro-pilot Diesel-NG Dual Fuel Combustion in a Constant Volume Combustion Vessel Utilizing the Premixed Pre-burn Procedure

A constant volume spray and combustion vessel utilizing the pre-burn mixture procedure to generate pressure, temperature, and composition characteristic of near top dead center (TDC) conditions in compression ignition (CI) engines was modified here with post pre-burn gas induction to incorporate premixed methane gas prior to diesel injection to simulate processes in dual fuel engines. Two variants of the methane induction system were developed and studied. The first used a high-flow modified direct injection injector and the second utilized auxiliary ports in the vessel that are used for normal intake and exhaust events. Flow, mixing, and limitations of the induction systems were studied. As a finding of this study, the high-flow modified direct injection injector was selected because of its controlled actuation and rapid closure. Further studies of the induction system post pre-burn were conducted to determine the temperature limit of the methane auto-ignition. It was found that for sufficient induction and mixing time determined from experimental observations and CFD modeling studies, a maximum core temperature of 750 K at the time of micro-pilot diesel injection can be achieved. Although lower than TDC temperatures in diesel CI engines, this temperature is sufficient for studying dual fuel injection and auto-ignition with high cetane fuels. Results from this work confirm the feasibility of dual fuel combustion using the proposed CV process and provide constraints for further micro-pilot diesel-NG dual fuel combustion studies.

03 NATURAL GAS↗

The partially aligned gradient instability in the ionosphere

Ionization irregularities which are almost but not exactly aligned along the magnetic field may grow much more rapidly than purely aligned irregularities in the presence of a background gradient of ionization and current flow. The stability of these irregularities is considered, taking into account the finite thickness of the gradient and shear in the ion motion. It is shown in particular that the normal E region of the ionosphere is usually stable, whereas sporadic E is often unstable, and this may limit the compression of metallic ions to form such layers. The F region may sometimes be unstable. Temperate zone conditions are considered throughout.

Whitehead, J. D.↗

The performance of smooth-wall drag reducing outer-layer devices in rough-wall boundary layers

The boundary layer drag on a 0.28 m x 0.91 m flat-plate was measured to evaluate the performance of smooth-wall drag reducing outer-layer devices in rough-wall boundary layers up to a chord Reynolds number, Re(c) of 17,000. The devices were a pair of thin flat ribbons placed in tandem. The wall conditions examined were smooth, transverse-groove roughnesses having cavity width/depth ratios of 0.7 (d-type) and 3 (k-type), and sandpaper roughness (k-type) of grit sizes 180, 50 and 36. The area-averaged wall-drag was reduced compared to the respective normal levels for all wall conditions. All k-type rough walls exhibited a comparable level of drag reduction (about 7 percent) which was lower than that in the smooth-wall. The d-type rough-wall exhibited a transitional behavior in that the drag reduction dropped from the smooth-wall level to that of the k-type roughnesses with increase in the flow speed. In further experiments on a 6 meter long sandpaper roughened wall and with a pair of symmetric airfoil devices in tandem at an Re(c) of 77,500, it was possible to recover the device drag penalty fully, but no net drag reduction was achieved. The apparent loss of performance of the devices in a rough-wall is explained in terms of their inability to alter the pressure component of the drag in a significant way.

Bandyopadhyay, P. R.↗

Acoustic Absorption Characteristics of an Orifice With a Mean Bias Flow

The objective of the study reported here was to acquire acoustic and flow data for numerical validation of impedance models that simulate bias flow through perforates. The impedance model is being developed by researchers at High Technology Corporation. This report documents normal incidence impedance measurements a singular circular orifice with mean flow passing through it. All measurements are made within a 1.12 inch (28.5 mm) diameter impedance tube. The mean flow is introduced upstream of the orifice (with the flow and incident sound wave travelling in the same direction) with an anechoic termination downstream of the orifice. Velocity profiles are obtained upstream of the orifice to characterize the inflow boundary conditions. Velocity in the center of the orifice is also obtained. All velocity measurements are made with a hot wire anemometer and subsequent checked with mass flow measurements made concurrently. All impedance measurements are made using the Two-Microphone Method. Although we have left the analysis of the data to the developers of the impedance models that simulate bias flow through perforate, our initial examination indicates that our results follow the trends consistent with published theory on impedance of perforates with a steady bias flow.

Ahuja, K. K.↗

Design Guide for Bearings Used in Cryogenic Turbopumps and Test Rigs

Cryogenic bearings are a unique and specialized area of the overall group of bearings that are used every day in industrial and aerospace applications. Cryogenic bearings operate in a unique environment that is not experienced by most bearing applications. The high speeds of turbomachinery, flow of cryogenic coolants, use of nonstandard materials, and lack of lubrication place unique demands on cryogenic bearings that must be met for the safety and success of the mission. To meet the goals of safety and success, requirements are put on the designer, manufacturer, and user that are not normally applied to off-the-shelf bearings. The designer has to have knowledge of the operating conditions, rotational speeds, loads, stresses, installation methods, inspection criteria, dimensional requirements, and design and analytical tools. The manufacturer needs to be aware of the materials used for cryogenic bearings, special heat treatments required, cleanliness of the processes, and inspection techniques to ensure a good product. The user needs to be aware of the safe handling practices to eliminate corrosion and debris, correct installation and removal procedures, pre- and post-test inspections, and the documentation that follow the bearings. This guide is based on the experiences of engineers at NASA Marshall Space Flight Center (MSFC) that have been involved in bearing research and testing along with specific bearing references that have been written. It is not meant to be a bearing design textbook for cryogenic bearing applications. These are available from many authors. Its purpose is to help the designer, manufacturer, or user in the application of cryogenic bearings to better understand the requirements placed on these bearings.

H. G. Gibson↗

Application of Jacobian-free Newton–Krylov method in implicitly solving two-fluid six-equation two-phase flow problems: Implementation, validation and benchmark

This work represents a first-of-its-kind successful application to employ advanced numerical methods in solving realistic two-phase flow problems with two-fluid six-equation two-phase flow model. These advanced numerical methods include high-resolution spatial discretization scheme with staggered grids (high-order) fully implicit time integration schemes, and Jacobian-free Newton–Krylov (JFNK) method as the nonlinear solver. The computer code developed in this work has been extensively validated with existing experimental flow boiling data in vertical pipes and rod bundles, which cover wide ranges of experimental conditions, such as pressure, inlet mass flux, wall heat flux and exit void fraction. Additional code-to-code benchmark with the RELAP5-3D code further verifies the correct code implementation. The combined methods employed in this work exhibit strong robustness in solving two-phase flow problems even when phase appearance (boiling) and realistic discrete flow regimes are considered. Transitional flow regimes used in existing system analysis codes, normally introduced to overcome numerical difficulty, were completely removed in this work. As a result, this in turn provides the possibility to utilize more sophisticated flow regime maps in the future to further improve simulation accuracy.

42 ENGINEERING↗

Consumption of the electric power inside silent discharge reactors

An experimental study was made in this paper to investigate the relation between the places of the dielectric barriers, which cover the surfaces of the electrodes in the coaxial cylindrical reactors, and the rate of change of the electric power that is consumed in forming silent discharges. Therefore, silent discharges have been formed inside three coaxial cylindrical reactors. The dielectric barriers in these reactors were pasted on both the internal surface of the outer electrode in the first reactor and the external surface of the inner electrode in the second reactor as well as the surfaces of the two electrodes in the third reactor. The reactor under study has been fed by atmospheric air that flowed inside it with a constant rate at normal temperature and pressure, in parallel with the application of a sinusoidal ac voltage between the electrodes of the reactor. The electric power consumed in forming the silent discharges inside the three reactors was measured as a function of the ac peak voltage. The validity of the experimental results was investigated by applying Manley's equation on the same discharge conditions. The results have shown that the rate of consumption of the electric power relative to the ac peak voltage per unit width of the discharge gap improves by a ratio of either 26.8% or 80% or 128% depending on the places of the dielectric barriers that cover the surfaces of the electrodes inside the three reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupling conditions for integrating boundary layer and rotational inviscid flow

The matching of a boundary layer and a rotational inviscid flow is reexamined by extending the Johnson and Sockol (1979) coupling conditions to include the case where the boundary layer solution includes the second-order effects of the freestream vorticity and the total temperature gradient. It is pointed out that two of the three conditions are not independent. If the boundary layer solution satisfies the appropriate momentum and energy integral equations, it follows that the imposition of the normal mass flux condition insures that the conditions on a normal flux of streamwise momentum and total enthalpy will also be satisfied.

Sockol, P. M.↗

Shock structure measured in a transonic fan using laser anemometry

Shock structure measurements acquired in a low aspect ratio transonic fan rotor are presented and analyzed. The rotor aspect ratio is 1.56 and the design tip relative Mach number is 1.38. The rotor flowfield was surveyed at near maximum efficiency and near stall operating conditions. Intra-blade velocity measurements acquired with a laser fringe anemometer on blade-to-blade planes in the supersonic region from 10 to 60 percent span are presented. The three-dimensional shock surface determined from the velocity measurments is used to determine the shock surface normal Mach number in order to properly calculate the ideal shock jump conditions. The ideal jump conditions are calculated based upon the Mach numbers measured on a surface of revolution and based upon the normal Mach number to indicate the importance of accounting for shock three dimensionality in turbomachinery design. Comparison of the shock locations with those predicted by a 3-D Euler code showed very good agreement and indicated the usefulness of integrating computational and experimental work to enhance the understanding of the flow physics occurring in transonic turbomachinery passages.

Wood, Jerry R.↗

Improved nonequilibrium viscous shock-layer scheme for hypersonic blunt-body flowfields

The nonequilibrium viscous shock-layer (VSL) solution scheme is revisited to improve its solution accuracy in the stagnation region and also to minimize and control errors in the conservation of elemental mass. The stagnation-point solution is improved by using a second-order expansion for the normal velocity, and the elemental mass conservation is improved by directly imposing the element conservation equations as solution constraints. These modifications are such that the general structure and computational efficiency of the nonequilibrium VSL scheme is not affected. This revised nonequilibrium VSL scheme is used to study the Mach 20 flow over a 7-deg sphere-cone vehicle under 0- and 20-deg angle-of-attack conditions. Comparisons are made with the corresponding predictions of Navier-Stokes and parabolized Navier-Stokes solution schemes. The results of these tests show that the nonequilibrium blunt-body VSL scheme is indeed an accurate, fast, and extremely efficient means for generating the blunt-body flowfield over spherical nose tips at zero-to-large angles of attack.

Bhutta, Bilal A.↗

Finite Difference Time Marching in the Frequency Domain: A Parabolic Formulation for Aircraft Acoustic Nacelle Design

An explicit finite difference iteration scheme is developed to study harmonic sound propagation in aircraft engine nacelles. To reduce storage requirements for large 3D problems, the time dependent potential form of the acoustic wave equation is used. To insure that the finite difference scheme is both explicit and stable, time is introduced into the Fourier transformed (steady-state) acoustic potential field as a parameter. Under a suitable transformation, the time dependent governing equation in frequency space is simplified to yield a parabolic partial differential equation, which is then marched through time to attain the steady-state solution. The input to the system is the amplitude of an incident harmonic sound source entering a quiescent duct at the input boundary, with standard impedance boundary conditions on the duct walls and duct exit. The introduction of the time parameter eliminates the large matrix storage requirements normally associated with frequency domain solutions, and time marching attains the steady-state quickly enough to make the method favorable when compared to frequency domain methods. For validation, this transient-frequency domain method is applied to sound propagation in a 2D hard wall duct with plug flow.

Baumeister, Kenneth J.↗

Finite Difference Time Marching in the Frequency Domain: A Parabolic Formulation for the Convective Wave Equation

An explicit finite difference iteration scheme is developed to study harmonic sound propagation in ducts. To reduce storage requirements for large 3D problems, the time dependent potential form of the acoustic wave equation is used. To insure that the finite difference scheme is both explicit and stable, time is introduced into the Fourier transformed (steady-state) acoustic potential field as a parameter. Under a suitable transformation, the time dependent governing equation in frequency space is simplified to yield a parabolic partial differential equation, which is then marched through time to attain the steady-state solution. The input to the system is the amplitude of an incident harmonic sound source entering a quiescent duct at the input boundary, with standard impedance boundary conditions on the duct walls and duct exit. The introduction of the time parameter eliminates the large matrix storage requirements normally associated with frequency domain solutions, and time marching attains the steady-state quickly enough to make the method favorable when compared to frequency domain methods. For validation, this transient-frequency domain method is applied to sound propagation in a 2D hard wall duct with plug flow.

Baumeister, K. J.↗

Numerical Simulation of No Vent Chill and Fill of a Large Liquid Hydrogen Tank

On orbit transfer of cryogenic liquids is necessary for many future space missions. The techniques required to transfer cryogens in micro gravity are quite different from ground system applications. In normal gravity, cryogenic tanks are usually filled from the bottom at nearly atmospheric pressure. The vapor generated due to heat transfer from warm tank walls, is allowed to vent from the top of the tank while the tank is being filled. If the normal gravity technique is used on orbit, the uncertainty of liquid and vapor distributions in unsettled condition may result in dumping of large amounts of liquid propellant overboard. The Vented Chill and No Vent Fill (VCNVF) process is a methodology [1] used to reduce propellant loss by holding the vent valve open during initial wall chilldown, preventing over-pressurization of the tank and stalling of the incoming flow, but closing the tank vent valve after chilling the tank wall sufficiently. An accurate simulation of no vent tank chill and fill is necessary to estimate the amount of propellant necessary to chill the tank, determine the maximum sustainable flowrate to fill the tank without stalling, and establish a timeline for the filling process. Numerical modeling of filling a cryogenic tank is complex because the flow is two-phase and the process involves both boiling and condensation with heat transfer between solid and fluid. In recent years, progress has been made to develop a numerical modeling technique [2,3,4] that has been verified by comparing with the test data from a small flight tank using liquid nitrogen [5]. The purpose of the present paper is to apply this technique in a larger tank with liquid hydrogen and compare with the test data of Chato [1]. The K-site Test Facility [1], shown in Figure 1, consists of a Test Tank, spray system, instrumentation, and the vacuum chamber. The test tank selected was ellipsoidal with an 87 inch major diameter and a 1.2 to 1 major to minor axis ratio. The two ends are joined by a short 1.5 inch cylindrical section. The tank is made of 2219 aluminum chemically milled to a nominal thickness of 0.087 inches. The tank weighs 329.25 pounds, and the tank volume is 175 ft 3 . The GFSSP model of the Test Tank is shown in Figure 2. Node 13 is a boundary node that represents the supply tank which is supplying liquid hydrogen at a given pressure and temperature. The total measured flowrate is evenly distributed through Branches 131 through 139. Nodes 1 through 9 represent the test tank and they are connected with metal solid nodes 14 through 22 through fluid-to-solid conductors that allow convective heat transfer between the solid and fluid nodes. The predicted tank pressure, filling rate, wall temperature and fluid temperature will be compared with test data.

Alok Majumdar↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Interaction between a normal shock wave and a turbulent boundary layer at high transonic speeds. II - Wall shear stress

Asymptotic methods are used to calculate the shear stress at the wall for the interaction between a normal shock wave and a turbulent boundary layer on a flat plate. A mixing length model is used for the eddy viscosity. The shock wave is taken to be strong enough that the sonic line is deep in the boundary layer and the upstream influence is thus very small. It is shown that unlike the result found for laminar flow an asymptotic criterion for separation is not found; however, conditions for incipient separation are computed numerically using the derived solution for the shear stress at the wall. Results are compared with available experimental measurements.

Liou, M. S.↗

Dissipation of thick accretion disks

A thick accretion disk which is isentropic cannot have simple laminar flow because fluid elements follow orbits which intersect the orbits of other fluid elements, leading to turbulence in astrophysical disks which have very large Reynolds numbers. The turbulence in such disks is estimated using molecular analogies for the behavior of the fluid elements. The usual empirical dissipation parameter 'alpha' is found to be equal to 0.25 under normal circumstances. Characteristic local disk parameters are calculated for a variety of conditions at different distances from a central star of one solar mass. Circumstances involving low midplane optical depths or external heating which can lead to large reductions in the turbulence are discussed.

Cameron, A. G. W.↗

Modeling the use of a binary mixture as a control scheme for two-phase thermal systems

Two-phase thermal loops using mechanical pumps, capillary pumps, or a combination of the two have been chosen as the main heat transfer systems for the space station. For these systems to operate optimally, the flow rate in the loop should be controlled in response to the vapor/liquid ratio leaving the evaporator. By substituting a mixture of two non-azeotropic fluids in place of the single fluid normally used in these systems, it may be possible to monitor the temperature of the exiting vapor and determine the vapor/liquid ratio. The flow rate would then be adjusted to maximize the load capability with minimum energy input. A FLUINT model was developed to study the system dynamics of a hybrid capillary pumped loop using this type of control and was found to be stable under all the test conditions.

Benner, S. M.↗