Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coefficient of performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Feasibility Study for a Near Term Demonstration of Laser-Sail Propulsion from the Ground to Low Earth Orbit

This paper adds to the body of research related to the concept of propellant-less in-space propulsion utilizing an external high energy laser (HEL) to provide momentum to an ultra-lightweight (gossamer) spacecraft. It has been suggested that the capabilities of Space Situational Awareness assets and the advanced analytical tools available for fine resolution orbit determination make it possible to investigate the practicalities of a ground to Low Earth Orbit (LEO) demonstration at delivered power levels that only illuminate a spacecraft without causing damage to it. The degree to which this can be expected to produce a measurable change in the orbit of a low ballistic coefficient spacecraft is investigated. Key system characteristics and estimated performance are derived for a near term mission opportunity involving the LightSail 2 spacecraft and laser power levels modest in comparison to those proposed previously by Forward, Landis, or Marx. [1,2,3] A more detailed investigation of accessing LightSail 2 from Santa Rosa Island on Eglin Air Force Base on the United States coast of the Gulf of Mexico is provided to show expected results in a specific case.

Montgomery, Edward E., IV↗

Retrieval of Macro- and Micro-Physical Properties of Oceanic Hydrosols from Polarimetric Observations

Remote sensing has mainly relied on measurements of scalar radiance and its spectral and angular features to retrieve micro- and macro-physical properties of aerosols/hydrosols. However, it is recognized that measurements that include the polarimetric characteristics of light provide more intrinsic information about particulate scattering. To take advantage of this, we used vector radiative transfer (VRT) simulations and developed an analytical relationship to retrieve the macro and micro-physical properties of the oceanic hydrosols. Specifically, we investigated the relationship between the observed degree of linear polarization (DoLP) and the ratio of attenuation-to- absorption coefficients (c/a) in water, from which the scattering coefficient can be readily computed (b equals c minus a), after retrieving a. This relationship was parameterized for various scattering geometries, including sensor zenith/azimuth angles relative to the Sun's principal plane, and for varying Sun zenith angles. An inversion method was also developed for the retrieval of the microphysical properties of hydrosols, such as the bulk refractive index and the particle size distribution. The DoLP vs c/a relationship was tested and validated against in-situ measurements of underwater light polarization obtained by a custom-built polarimeter and measurements of the coefficients a and c, obtained using an in-water WET (Western Environmental Technologies) Labs ac-s (attenuation coefficients In-Situ Spectrophotometer) instrument package. These measurements confirmed the validity of the approach, with retrievals of attenuation coefficients showing a high coefficient of determination depending on the wavelength. We also performed a sensitivity analysis of the DoLP at the Top of Atmosphere (TOA) over coastal waters showing the possibility of polarimetric remote sensing application for ocean color.

PACE↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Remote monitoring of agricultural systems using NDVI time series and machine learning methods: a tool for an adaptive agricultural policy

This study aims to provide accurate information about changes in agricultural systems (AS) using phenological metrics derived from the NDVI time series. Use of such information could help land managers optimize land use choices and monitor the status of agricultural lands, under a variety of environmental and socioeconomic conditions. For this purpose, the Moderate Resolution Imaging Spectroradiometer (MODIS) NDVI data were used to derive phenological metrics over the Oum Er-Rbia basin (central Morocco). Random forest (RF), support vector machine (SVM), and K-nearest neighbor (KNN) classifiers were explored and compared on their ability to classify AS classes over the study area. Four main AS classes have been considered: (1) irrigated annual crop (IAC), (2) irrigated perennial crop (IPC), (3) rainfed area (RA), and (4) fallow (FA). By comparing the accuracy of the three classifiers, the RF method showed the best performance with an overall accuracy of 0.97 and kappa coefficient of 0.96.The RF method was then chosen to examine time variations in AS over a 16-year period (2000–2016). The AS main variations were detected and evaluated for the four AS classes. These variations have been found to be linked well with other indicators of local agricultural land management, as well as the historical agricultural drought changes over the study area. Overall, the results present a tool for decision makers to improve agricultural management and provide a different perspective in understanding the spatiotemporal dynamics of agricultural systems.

Youssef Lebrini↗

Model Evaluation of Short-Lived Climate Forcers for the Arctic Monitoring and Assessment Programme: A Multi-Species, Multi-Model Study

While carbon dioxide is the main cause for global warming, modeling short-lived climate forcers (SLCFs) such as methane, ozone, and particles in the Arctic allows us to simulate near-term climate and health impacts for a sensitive, pristine region that is warming at 3 times the global rate. Atmospheric modeling is critical for understanding the long-range transport of pollutants to the Arctic, as well as the abundance and distribution of SLCFs throughout the Arctic atmosphere. Modeling is also used as a tool to determine SLCF impacts on climate and health in the present and in future emissions scenarios. In this study, we evaluate 18 state-of-the-art atmospheric and Earth system models by assessing their representation of Arctic and Northern Hemisphere atmospheric SLCF distributions, considering a wide range of different chemical species (methane, tropospheric ozone and its precursors, black carbon, sulfate, organic aerosol, and particulate matter) and multiple observational datasets. Model simulations over 4 years (2008-2009 and 2014-2015) conducted for the 2022 Arctic Monitoring and Assessment Programme (AMAP) SLCF assessment report are thoroughly evaluated against satellite, ground, ship, and aircraft-based observations. The annual means, seasonal cycles, and 3-D distributions of SLCFs were evaluated using several metrics, such as absolute and percent model biases and correlation coefficients. The results show a large range in model performance, with no one particular model or model type performing well for all regions and all SLCF species. The multi-model mean (mmm) was able to represent the general features of SLCFs in the Arctic and had the best overall performance. For the SLCFs with the greatest radiative impact (CH4, 03, BC, and SO(sup 2-)(sub 4)), the mmm was within ±25 % of the measurements across the Northern Hemisphere. Therefore, we recommend a multi-model ensemble be used for simulating climate and health impacts of SLCFs. Of the SLCFs in our study, model biases were smallest for C"4 and greatest for OA. For most SLCFs, model biases skewed from positive to negative with increasing latitude. Our analysis suggests that vertical mixing, long-range transport, deposition, and wildfires remain highly uncertain processes. These processes need better representation within atmospheric models to improve their simulation of SLCFs in the Arctic environment. As model development proceeds in these areas, we highly recommend that the vertical and 3-D distribution of SLCFs be evaluated, as that information is critical to improving the uncertain processes in models.

Arctic Monitoring and Assessment Programme↗

PM 2.5 Concentrations over Major Metropolitan Regions Inferred from Airborne High Spectral Resolution Lidar Measurements Using Machine Learning Regression

We use measurements of near-surface aerosol backscatter, extinction, and depolarization acquired by four NASA Langley Research Center airborne High Spectral Resolution Lidars (HSRLs) to develop a machine learning regression methodology to infer PM2.5 concentrations at the surface and aloft. These airborne HSRL measurements were acquired over major metropolitan regions in the United States and Asia during more than 170 flights since 2010. Hourly surface PM2.5 measurements from the EPA air quality system and similar networks in other countries acquired within 10 km and 15 minutes of these near-surface HSRL measurements are used to train models that compute PM2.5 concentrations from the HSRL measurements. We examine several regression methods and find that exponential Gaussian Process algorithms consistently give the best performance in terms of the lowest root-mean-square (RMS) errors and the highest correlations. Model performance varies significantly depending on various combinations of HSRL aerosol measurements (e.g., aerosol backscatter, extinction, depolarization, backscatter color ratios, lidar ratios, aerosol optical thickness) and retrievals (e.g., mixed layer height, aerosol type) used in the regressions. Models that use near-surface measurements of aerosol backscatter and aerosol intensive properties such as depolarization, backscatter color ratio, and lidar ratio typically give the best performance with RMS errors around 4 mg/m3 and correlation coefficients above 0.9. HSRL measurements were often acquired when the aircraft flew systematic “raster-scan” patterns for several hours over these cities. These flight patterns enabled measurements of the spatial, temporal, and vertical variabilities in the distributions of aerosol backscatter and aerosol intensive properties and allowed us to derive the corresponding variabilities in PM2.5 concentrations. We present examples of such variabilities over urban areas in the United States as well as Asia. We describe also how the distribution of surface PM2.5 varies with aerosol type and use these retrievals to examine model simulations of surface PM2.5 in these metropolitan regions. We also discuss how this methodology may be applied to measurements from satellite lidars such as CALIOP on CALIPSO and ATLID on EarthCARE.

lidar↗

MODELING, IMPLEMENTATION AND CONTROL OF A CVT BASED PTO FOR A SMALL SCALE MHK-TURBINE IN LOW FLOW SPEED OPERATION

Modeling, implementation, field testing and control of a power takeoff (PTO) device equipped with a ball-type continuously variable transmission (B-CVT) for a small marine hydrokinetic (MHK) turbine deployed from a floating unmanned autonomous mobile catamaran platform is described. The turbine is a partially submerged multi-blade undershot waterwheel (USWW). A validated numerical torque model for the MHK turbine has been derived and a speed controller has been developed, implemented and tested in the field. The dependance of the power generated as a function of number and submergence level of turbine blades has been investigated and the number of blades that maximizes power production is determined. Bench and field testing in support of characterizing the power conversion capabilities of MHK turbine and PTO are described. Detailed results of the final torque and power coefficient models, the controls architecture, and the MHK turbine performance with varying numbers of blades are provided.

Pimentel, Hugo↗

Singular-Arc Time-Optimal Trajectory of Aircraft in Two-Dimensional Wind Field

This paper presents a study of a minimum time-to-climb trajectory analysis for aircraft flying in a two-dimensional altitude dependent wind field. The time optimal control problem possesses a singular control structure when the lift coefficient is taken as a control variable. A singular arc analysis is performed to obtain an optimal control solution on the singular arc. Using a time-scale separation with the flight path angle treated as a fast state, the dimensionality of the optimal control solution is reduced by eliminating the lift coefficient control. A further singular arc analysis is used to decompose the original optimal control solution into the flight path angle solution and a trajectory solution as a function of the airspeed and altitude. The optimal control solutions for the initial and final climb segments are computed using a shooting method with known starting values on the singular arc The numerical results of the shooting method show that the optimal flight path angle on the initial and final climb segments are constant. The analytical approach provides a rapid means for analyzing a time optimal trajectory for aircraft performance.

Nguyen, Nhan↗

Constraints on standard model effective field theory for a Higgs boson produced in association with W or Z bosons in the H → $\textrm{b}\overline{\textrm{b}}$ decay channel in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A standard model effective field theory (SMEFT) analysis with dimension-six operators probing nonresonant new physics effects is performed in the Higgs-strahlung process, where the Higgs boson is produced in association with a W or Z boson, in proton-proton collisions at a center-of-mass energy of 13 TeV. The final states in which the W or Z boson decays leptonically and the Higgs boson decays to a pair of bottom quarks are considered. The analyzed data were collected by the CMS experiment between 2016 and 2018 and correspond to an integrated luminosity of 138 fb −1 . An approach designed to simultaneously optimize the sensitivity to Wilson coefficients of multiple SMEFT operators is employed. Likelihood scans as functions of the Wilson coefficients that carry SMEFT sensitivity in this final state are performed for different expansions in SMEFT. The results are consistent with the predictions of the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Velocity reconstruction in the era of DESI and Rubin/LSST. I. Exploring spectroscopic, photometric, and hybrid samples

Peculiar velocities of galaxies and halos can be reconstructed from their spatial distribution alone. This technique is analogous to the baryon acoustic oscillations reconstruction, using the continuity equation to connect density and velocity fields. The resulting reconstructed velocities can be used to measure imprints of galaxy velocities on the cosmic microwave background like the kinematic Sunyaev-Zel’dovich effect or the moving lens effect. As the precision of these measurements increases, characterizing the performance of the velocity reconstruction becomes crucial to allow unbiased and statistically optimal inference. In this paper, we quantify the relevant performance metrics: the variance of the reconstructed velocities and their correlation coefficient with the true velocities. We show that the relevant velocities to reconstruct for kSZ and moving lens are actually the halo—rather than galaxy—velocities. We quantify the impact of redshift-space distortions, photometric redshift errors, satellite galaxy fraction, incorrect cosmological parameter assumptions and smoothing scale on the reconstruction performance. Here, we also investigate hybrid reconstruction methods, where velocities inferred from spectroscopic samples are evaluated at the positions of denser photometric samples. We find that using exclusively the photometric sample is better than performing a hybrid analysis. The 2 Gpc/ℎ length simulations from abacussummit with realistic galaxy samples for DESI and Rubin LSST allow us to perform this analysis in a controlled setting. In the companion paper [B. Hadzhiyska, S. Ferraro, B. Ried Guachalla, and E. Schaan, companion paper, Phys. Rev. D 109, 103534 (2024).], we further include the effects of evolution along the light cone and give realistic performance estimates for DESI luminous red galaxies, emission line galaxies, and Rubin LSST-like samples.

79 ASTRONOMY AND ASTROPHYSICS↗

SNPP and N20 VIIRS Day/Night Band (DNB) Calibration and Performance

The first two Visible Infrared Imaging Radiometer Suite (VIIRS) instruments, on-board the Suomi National Polar-orbiting Partnership (SNPP) and the NOAA-20 (N20) satellites, have been operating for over 11 and 5 years since their launches on28 October 2011 and 18 November 2017 respectively. The day-night band (DNB) onboard VIIRS is a panchromatic visible/near-infrared (Vis/NIR) channel designed to detect radiance from the brightest daytime scenes down to very dim nighttime scenes illuminated by a quarter moon. In this paper, we present the SNPP and N20 VIIRS DNB calibration results performed by the NASA VIIRS Characterization Support Team (VCST) to generate the calibration coefficient look up tables (LUTs) for the latest NASA Level 1B Collection 2 products. The differing DNB straylight contamination between VIIRS instruments is discussed along with the correction methodology and performance.

Junqiang Sun↗

Fluid dynamics and convective heat transfer in impinging jets through implementation of a high resolution liquid crystal technique

A combined convective heat transfer and fluid dynamics investigation in a turbulent round jet impinging on a flat surface is presented. The experimental study uses a high resolution liquid crystal technique for the determination of the convective heat transfer coefficients on the impingement plate. The heat transfer experiments are performed using a transient heat transfer method. The mean flow and the character of turbulent flow in the free jet is presented through five hole probe and hot wire measurements, respectively. The flow field character of the region near the impingement plate plays an important role in the amount of convective heat transfer. Detailed surveys obtained from five hole probe and hot wire measurements are provided. An extensive validation of the liquid crystal based heat transfer method against a conventional technique is also presented. After a complete documentation of the mean and turbulent flow field, the convective heat transfer coefficient distributions on the impingement plate are presented. The near wall of the impingement plate and the free jet region is treated separately. The current heat transfer distributions are compared to other studies available from the literature. The present paper contains complete sets of information on the three dimensional mean flow, turbulent velocity fluctuations, and convective heat transfer to the plate. The experiments also prove that the present nonintrusive heat transfer method is highly effective in obtaining high resolution heat transfer maps with a heat transfer coefficient uncertainty of 5.7 percent.

Kim, K.↗

On the Accuracy of CFD-Based Pressure Drop Predictions for Right-Angle Ducts

The predictive capability of computational fluid dynamics (CFD) codes for turbulent flow through curved ducts is of significant importance to the design and performance analysis of modern rocket engine flowpaths. Code calibration and validation studies for this class of flow are desireable to estimate the performance margin and operating range of components designed using Navier-Stokes methods. Parametric experimental studies such as that of Weske (NACA ARR W-39) provided a wealth of performance data for the design of single- and compound elbow configurations with various cross-sections, curvature and aspect ratios at varying Reynolds numbers. In that work, the majority of data is presented in the form of loss coefficients, characterizing pressure losses due to duct curvature, and including losses due to wall friction. Using measured friction coefficients, losses of equivalent straight lengths of duct are subtracted, resulting in performance curves useful for design computations. These data are currently used in a CFD-based parametric study covering a broad range of operating conditions. Of particular interest for the accuracy of CFD predictions are the effects on pressure loss due to inlet boundary layer thickness (dependent on upstream development length), and the wall treatment for the turbulence equations (conventional wall functions vs. wall integration using a two-layer model). The experimental data are reassessed in the form of an error analysis, and are compared with CFD predictions for 18 computational cases. Grid-independence, grid spacing, and convergence requirements of the cases are discussed. Conclusions regarding the relative importance of the parametric variables will be presented.

Brankovic, Andreja↗

Surface-Normal Active Flow Control for Lift Enhancement and Separation Mitigation for High-Lift Common Research Model

This study explores the feasibility of using small surface-normal jets near the flap trailing edge as active aerodynamic load control on the high-lift Common Research Model wing/-body configuration. Chimera Grid Tools are utilized to generate structured curvilinear overset grids, and the Reynolds-averaged Navier-Stokes solver OVERFLOW is employed to solve for the flow-field around the geometry. The so-called microjet is initially employed across both the inboard and the outboard flaps on the pressure-side near the trailing edge. It is shown that implementing the microjet on the inboard flap is more effective compared to implementing it on the outboard flap. This is because, prior to microjet implementation, the flow on the outboard flap exhibits extensive separation, while the flow on the inboard flap exhibits moderate separation. For microjet implementation across the inboard flap only, the relationship between momentum coefficient of the microjet and lift-enhancement is found to be∆CL'1.66√Cμfor the rangeCμ= 0.00−0.012. We show that implementing a microjet with a jet velocity ratio of one, which corresponds toCμ= 0.003, can shift the linear region of the lift curve by ∆CL= 0.08. The linear shift in the lift curve is significant for enhancing airplane performance such as increasing its payload. Microjet implementation effects on the drag coefficient are also investigated through a drag decomposition analysis. Further, we employ an induced drag analysis based on the spanwise load distribution and show that the microjet-related increase in pressure drag coefficient is dominated by the increase in the induced drag while microjet implementation reduces the form drag. These preliminary results show that favorable changes in aerodynamic performance can be achieved by using the surface-normal jets presented in this study.

ARMD↗

Horizontal mixing coefficients for two-dimensional chemical models calculated from National Meteorological Center Data

Calculations of the two-dimensional, species-independent mixing coefficients for two-dimensional chemical models for the troposphere and stratosphere are performed using quasi-geostrophic potential vorticity fluxes and gradients from 4 years of National Meteorological Center data for the four seasons in both hemispheres. Results show that the horizontal mixing coefficient values for the winter lower stratosphere are broadly consistent with those currently employed in two-dimensional models, but the horizontal mixing coefficient values in the northern winter upper stratosphere are much larger than those usually used.

Newman, P. A.↗

Tribological performance of Al2O3-B2O3 composites: Role of CuOand CaO constituents

Al2O3-B2O3 based composites for wear resistant applications (e.g., seal rings and bearings) were manufactured using powder metallurgy route. Four different compositions were considered to control amount of in situ phases, mainly aluminum borate, formed during sintering. The fabricated composites were characterized using X-ray diffraction to identify the phases. Hardness was measured in terms of micro-hardness. The tribological performance of the composites were evaluated by conducting dry sliding tests against alumina balls at different humidity levels (10 – 95% relative humidity). The X-ray spectrum revealed that increase in B2O3 content in the composites increased the amount of aluminum borate phase that enhanced the micro-hardness. Results revealed that aluminum borate enhanced the wear resistance of the composites, whereas the humidity-sensitive alumina phase reduced friction at higher humidity levels. Furthermore, CuO and CaO (2-5 wt.%) were added separately to the composite, resulting in increased density by 22-48 %. Athough the addition of CuO and CaO led to increase in hardness and wear resistance of the composites, the coefficient of friction was negatively affected. The friction and wear performance along with wear mechanism are discussed with respect to observed phases in the composites.

Ashish K. Kasar↗

Modeling of particle transport, neutrals and radiation in magnetically-confined plasmas with Aurora

In this work, we present Aurora, an open-source package for particle transport, neutrals and radiation modeling in magnetic confinement fusion plasmas. Aurora's modern multi-language interface enables simulations of 1.5D impurity transport within high-performance computing frameworks, particularly for the inference of particle transport coefficients. A user-friendly Python library allows simple interaction with atomic rates from the Atomic Data and Atomic Structure database as well as other sources. This enables a range of radiation predictions, both for power balance and spectroscopic analysis. We discuss here the superstaging approximation for complex ions, as a way to group charge states and reduce computational cost, demonstrating its wide applicability within the Aurora forward model and beyond. Aurora also facilitates neutral particle analysis, both from experimental spectroscopic data and other simulation codes. Leveraging Aurora's capabilities to interface SOLPS-ITER results, we demonstrate that charge exchange is unlikely to affect the total radiated power from the ITER core during high performance operation. Finally, we describe the ImpRad module in the one modeling framework for integrated task framework, developed to enable experimental analysis and transport inferences on multiple devices using Aurora.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Flat-Plate Heat Pipe Functionality for Fuel Cell Application

For many exothermic systems such as proton exchange membrane (PEM) fuel cells, cooling is necessary to maintain consistent and uniform operating temperatures which are generally in the range of 60 to 80°C. A potential solution is a heat pipe employing the principle of conduction in combination with a phase change. The purpose of this study was to fully characterize the operation of a heat pipe with unique geometry designed for fuel cell heat removal at operating temperatures up to 100°C and to assess the suitability of the resulting performance for cooling system integration. Test variables consist of cold sink thermal contact conductance coefficient improving material usage, heat rejection temperature, contact pressure and area, heat pipe orientation, operational hours, and variability between units. The test results showed that heat pipe performance improves through increased condenser and heat sink contact pressure, thermal contact coating usage, greater condenser area utilization, and colder heat sink temperature. Higher initial heat pipe temperature and greater age or operation time reduce the heat pipe capabilities. Placing the condenser lower than the evaporator is the only heat pipe orientation that affects evaporator plate temperature. Condensing fluid in the lower section reduces heat transfer capacity as that orientation requires liquid water to transport by wicking against gravity.

Smith, Phillip J.↗