Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charge coupled devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

TESS Lens-Bezel Assembly Modal Testing

The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

Modal Testing↗

DDOTI: the Deca-Degree Optical Transient Imager

DDOTI (Deca-Degree Optical Transient Imager) will be a wide-field robotic imager consisting of six 28-centimeter telescopes with prime focus CCDs (Charge-Coupled Devices) mounted on a common equatorial mount. Each telescope will have a field of view of 12 degrees squared, will have 2 arcsec pixels, and will reach a 10 sigma limiting magnitude in 60 seconds of r (redshift) equal to 18.7 in dark time and r (redshift) equal to 18.0 in bright time. The set of six will provide aninstantaneous field of view of about 72 degrees squared. DDOTI uses commercial components almost entirely. The first DDOTI willbe installed at the Observatorio Astronmico Nacional in Sierra San Pedro Martir, Baja California, Mexico in early 2017. The main science goals of DDOTI are the localization of the optical transients associated with GRBs (Gamma Ray Bursts) detected by the GBM (Gamma Ray Burst Monitor) instrument on the Fermi satellite and with gravitational-wave transients. DDOTI will also be used for studies of AGN (Active Galactic Nuclei) and YSO (Young Stellar Object) variability and to determine the occurrence of hot Jupiters. The principal advantage of DDOTI compared to other similar projects is cost: a single DDOTI installation costs only about US $500,000. This makes it possible to contemplate a global network of DDOTI installations. Such geographic diversity would give earlier access and a higher localization rate.We are actively exploring this option.

optical transients↗

X-Ray Diffraction on Mars: Scientific Discoveries Made by the CheMin Instrument

The Mars Science Laboratory Curiosity landed in Gale crater in August 2012 with the goal to identify and characterize habitable environments on Mars. Curiosity has been studying a series of sedimentary rocks primarily deposited in fluviolacustrine environments approximately 3.5 Ga. Minerals in the rocks and soils on Mars can help place further constraints on these ancient aqueous environments, including pH, salinity, and relative duration of liquid water. The Chemistry and Mineralogy (CheMin) X-ray diffraction and X-ray fluorescence instrument on Curiosity uses a Co X-ray source and charge-coupled device detector in transmission geometry to collect 2D Debye-Scherrer ring patterns of the less than 150 micron size fraction of drilled rock powders or scooped sediments. With an angular range of approximately 2.52deg 20 and a 20 resolution of approximately 0.3deg, mineral abundances can be quantified with a detection limit of approximately 1-2 wt. %. CheMin has returned quantitative mineral abundances from 16 mudstone, sandstone, and aeolian sand samples so far. The mineralogy of these samples is incredibly diverse, suggesting a variety of depositional and diagenetic environments and different source regions for the sediments. Results from CheMin have been essential for reconstructing the geologic history of Gale crater and addressing the question of habitability on ancient Mars.

Rampe, E. B.↗

Upwelling Radiance at 976 nm Measured from Space Using a CCD Camera

The Optical Payload for Lasercomm Science (OPALS) Flight System on-board the International Space Station uses a charge coupled device (CCD) camera for receiving a beacon laser from Earth. Relative measurements of the background contributed by upwelling radiance under diverse illumination conditions and varying terrain is presented. In some cases clouds in the field-of-view allowed a comparison of terrestrial and cloud-top upwelling radiance. In this paper we will report these measurements and examine the extent of agreement with atmospheric model predictions.

Biswas, Abhijit↗

Predicting Electron Population Characteristics in 2-D Using Multispectral Ground-Based Imaging

Ground-based imaging and in situ sounding rocket data are compared to electron transport modeling for an active inverted-V type auroral event. The Ground-to-Rocket Electrodynamics-Electrons Correlative Experiment (GREECE) mission successfully launched from Poker Flat, Alaska, on 3 March 2014 at 11:09:50 UT and reached an apogee of approximately 335 km over the aurora. Multiple ground-based electron-multiplying charge-coupled device (EMCCD) imagers were positioned at Venetie, Alaska, and aimed toward magnetic zenith. The imagers observed the intensity of different auroral emission lines (427.8, 557.7, and 844.6 nm) at the magnetic foot point of the rocket payload. Emission line intensity data are correlated with electron characteristics measured by the GREECE onboard electron spectrometer. A modified version of the GLobal airglOW (GLOW) model is used to estimate precipitating electron characteristics based on optical emissions. GLOW predicted the electron population characteristics with 20% error given the observed spectral intensities within 10 deg of magnetic zenith. Predictions are within 30% of the actual values within 20 deg of magnetic zenith for inverted-V-type aurora. Therefore, it is argued that this technique can be used, at least in certain types of aurora, such as the inverted-V type presented here, to derive 2-D maps of electron characteristics. These can then be used to further derive 2-D maps of ionospheric parameters as a function of time, based solely on multispectral optical imaging data.

multispectral ground-based imaging↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arc minute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arcminute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

Physics of the Cosmos (PCOS) Program Technology Development 2018

We present a final report on our program to raise the Technology Readiness Level (TRL) of enhanced charge‐coupled‐device (CCD) detectors capable of meeting the requirements of X‐ray grating spectrometers (XGS) and wide‐field X‐ray imaging instruments for small, medium, and large missions. Because they are made of silicon, all X‐ray CCDs require blocking filters to prevent corruption of the Xray signal by out‐of‐band, mainly optical and near‐infrared (near‐IR) radiation. Our primary objective is to demonstrate technology that can replace the fragile, extremely thin, free‐standing blocking filter that has been standard practice with a much more robust filter deposited directly on the detector surface. High‐performance, back‐illuminated CCDs have flown with free‐standing filters (e.g., one of our detectors on Suzaku), and other relatively low‐performance CCDs with directly deposited filters have flown (e.g., on the X‐ray Multi‐mirror Mission‐Newton, XMM‐Newton Reflection Grating Spectrometer, RGS). At the inception of our program, a high‐performance, back‐illuminated CCD with a directly deposited filter has not been demonstrated. Our effort will be the first to show such a filter can be deposited on an X‐ray CCD that meets the requirements of a variety of contemplated future instruments. Our principal results are as follows: i) we have demonstrated a process for direct deposition of aluminum optical blocking filters on back‐illuminated MIT Lincoln Laboratory CCDs. Filters ranging in thickness from 70 nm to 220 nm exhibit expected bulk visible‐band and X‐ray transmission properties except in a small number (affecting ≲ 1% of detector area) of isolated detector pixels ("pinholes"), which show higher‐than‐expected visible‐band transmission; ii) these filters produce no measurable degradation in soft‐X‐ray spectral resolution, demonstrating that direct filter deposition is compatible with the MIT Lincoln Laboratory back‐illumination process; iii) we have shown that under sufficiently intense visible and near‐IR illumination, out‐of‐band light can enter the detector through its sidewalls and mounting surfaces, compromising detector performance. This 'sidewall leakage' has been observed, for example, by a previous experiment on the International Space Station during its orbit‐day operations. We have developed effective countermeasures for this sidewall leakage; iv) we developed an exceptionally productive collaboration with the Regolith X‐ray Imaging Spectrometer (REXIS) team. REXIS is a student instrument now flying on the Origins Spectral Interpretation Resource Identification Security - Regolith Explorer (OSIRIS‐REx) mission. REXIS students participated in our filter development program, adopted our technology for their flight instrument, and raised the TRL of this technology beyond our initial goals. This Strategic Astrophysics Technology (SAT) project, a collaboration between the MKI and MIT Lincoln Laboratory, began July 1, 2012, and ended on June 30, 2018.

PCOS↗

Focal Plane Geometry Characterization of the Kepler Mission

The Kepler Mission focal plane contains 42 charge-coupled device (CCD) photodetectors. Each CCD is composed of 2.2 million square pixels, 27 micrometers on a side, arranged in a grid of 2,200 columns by 1,044 rows. The science goals of the Kepler Mission require that the position of each CCD be determined with an accuracy of 0.1 pixels, corresponding to 2.7 micrometers or 0.4 seconds of arc, a level which is not achievable through pre-flight metrology. We describe a technique for determining the CCD positioning using images of the Kepler field of view (FOV) obtained in flight. The technique uses the fitted centroid row and column positions of 400 pre-selected stars on each CCD to obtain empirical polynomials which relate sky coordinates (right ascension and declination) to chip coordinates (row and column). The polynomials are in turn evaluated to produce constraints for a nonlinear model fit which directly determines the model parameters describing the location and orientation of each CCD. The focal plane geometry characterization algorithm is itself embedded in an iterative process which determines the focal plane geometry and the Pixel Response Function for each CCD in a self-consistent manner. In addition to the fully automated calculation, a person-in-the-loop implementation was developed to allow an initial determination of the geometry in the event of large misalignments, achieving a much looser capture tolerance for more modest accuracy and reduced automation.

ccd↗

Nonlinearity and Pixel Shifting Effects in HXRG Infrared Detectors

We study the nonlinearity (NL) in the conversion from charge to voltage in infrared detectors (HXRG) for use in precision astronomy. We present laboratory measurements of the NL function of a H2RG detector and discuss the accuracy to which it would need to be calibrated in future space missions to performcosmological measurements through the weak gravitational lensingtechnique. In addition, we present an analysis of archival data from the infrared H1RG detector of the Wide Field Camera 3 in the Hubble Space Telescope that provides evidence consistent with the existence of a sensor effect analogous to the “brighter-fatter” effect found in Charge-Coupled Devices. We propose a model in which this effect could be understood as shifts in the effective pixel boundaries, and discuss prospects of laboratory measurements to fully characterize this effect.

Plazas, A. A.↗

The Hitomi X-Ray Observatory, Part 2

When it was launched on 17 February 2016, the Hitomi X-ray Observatory carried four kinds of new-generation x-ray instruments—the Soft X-ray Spectrometer (SXS), the Soft X-ray Imager (SXI), the Hard X-ray Imager (HXI), and the Soft Gamma-ray Detector (SGD). All four instruments were turned on and were in the process of activation at the time of loss of contact on 26 March 2016. In the time it was operational, Hitomi was able to provide researchers with a trove of ground-breaking scientific results. Initial results demonstrated that the instruments were meeting or exceeding requirements and that Hitomi was on its way to pioneering a new era of broad-band and high-resolution x-ray spectroscopy. The results published here summarize the in-flight instrument performance, calibration, and data processing accomplishments of the observatory. Of the papers accepted for publication in this special section, 17 were presented in Part 1 in the January-March 2018 issue of JATIS (Journal of Astronomical Telescopes, Instruments, and Systems). Ten more papers are presented here as Part 2 in the April-June 2018 issue. These papers cover the detailed in-flight performance of the four state-of the-art instruments on-board the Hitomi X-Ray Observatory. These instruments were extremely diverse in their design and principles of operation, ranging from low temperature x-ray calorimeters for high-resolution spectroscopy, CCDs (Charge-Coupled Devices) for wide field imaging, high fill-factor grazing incidence x-ray optics, including multilayer x-ray optics and silicon strip and CdTe strip detectors for high-energy imaging, and a Si/CdTe Compton cameras for extending the bandpass out to 600 kiloelectronvolts. All of these instruments operated as expected and for sufficient time to validate their operating principles and carry out first light scientific investigations, published elsewhere. Collectively, these instruments, all co-aligned and operated simultaneously, provided a tool for astronomers with unprecedented resolution and broadband sensitivity for investigating high-energy processes throughout the universe. These papers serve as part of the Hitomi legacy and will guide the next generation of instruments planned for future missions.

Kelley, Richard L.↗

CCD Star Tracker Experience -- Key Results from Astro 1 flight

Charge-coupled devices (CCDs) have now flown successfully in a number of space scientific and engineering instruments, and have rapidly become the preferred technology for most imaging applications. One of their earliest planned applications in space was in the precision (subarcsecond) star tracker for the Astro series of UV missions.

Astro↗

Application of the Active Pixel Sensor Concept to Guidance and Navigation

Charge-coupled devices (CCDs) have been used extensively in the past in star trackers and fine guidance systems. A new technology, the active pixel sensor, is a possible successor to CCDs. This technology potentially features the same sensitivity and performance of the CCD with additional improvements. These improvements include random access capability, easy window-of-interest readout, non-destructive readout for signal-to-noise improvement, high radiation tolerance, simplified clocking voltages, and easy integration with other on-chip signal processing circuitry. The state-of-the-art of this emerging technology and its potential application to guidance and navigation systems is discussed.

Eisenman, Allan R.↗

A broadband superconducting detector suitable for use in large arrays

Cryogenic detectors are extremely sensitive and have a wide variety of applications (particularly in astronomy), but are difficult to integrate into large arrays like a modern CCD (charge-coupled device) camera. As current detectors of the cosmic microwave background (CMB) already have sensitivities comparable to the noise arising from the random arrival of CMB photons, the further gains in sensitivity needed to probe the very early Universe will have to arise from large arrays. A similar situation is encountered at other wavelengths.

Crogenic↗

Near-infrared Reflectance of Rocks at high Temperature: Preliminary Results and Implications for Near-infrared Emissivity of Venus's Surface

Light emitted from Venus’s surface can be viewed through spectral “windows” in its atmosphere, in the nearinfrared (NIR) around 1000 nanometer (nm) wavelengths. The NIR emissivity of Venus’s surface can constrain rock types and their weathering state; emissivities can be measured directly or calculated from reflectances. We measured the reflectances of igneous and sedimentary rocks at Venus’s surface temperature, 400 °C–500 °C at 850 and 950 nm; samples were heated in a box furnace in air, illuminated by light-emitting diodes (LEDs), and imaged with a modified charge-coupled device (CCD) camera. Reflectances were also measured at 25 °C from 350 to 1400 nm. Rock reflectances at 850 and 950 nm and 400 °C–500 °C are nearly identical to those at 25 °C, except for the effects of nanophase hematite forming on some surfaces. Fresh basalts have reflectances (high and low temperatures) near 7.5%; a leucogranite similarly has reflectances near 50%. Pigmentary hematite has nearly identical reflectances at high- and low-temperature at these wavelengths. Pigmentary hematite appears dark brown 400 °C–500 °C because its absorption edge has shifted to beyond the limit of human vision. These rock reflectances imply that basalts should have emissivities near 0.9, and granite (and similar felsic rocks) should have lower emissivities ∼0.5. Thus, basalt and felsic rock should be easily distinguished in NIR emissivity measurements of Venus’s surface, such as are baselined in recent Venus mission proposals. Other sedimentary rocks should have even lower emissivities: quartz sand at around ∼0.3, and anhydrite as low as 0.1.

Allan H Treiman↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Quality Assurance of ISS LIS lightning Data

Optical lighting detection from space has been ongoing since 1995 from the Optical Transient detector (1995-2000), then later by the Lightning Imaging Sensors (LIS) on the Tropical Rainfall Measuring Mission (TRMM) satellite (1997-2015) and the International Space Station (ISS) (ISS 2017-present). A rapid readout (2 ms) 128x128 pixel CCD (Charge-coupled Device) array detects optical transients from lightning (events) and transmits the observations to ground. Ground processing determines whether individual events are likely due to lightning or noise. Likely lightning events are then grouped into groups, flashes, and areas and their location on the earth are determined. The lightning data are saved in orbit files; each file containing the time, location, and intensity of the lightning events, groups, flashes, and areas detected during one orbit. Even after this processing anomalies may exist in some of the orbits. A manual quality assurance (QA) procedure is performed monthly to assess the data and omit orbits with obvious anomalies from the dataset. These files are not included in the final dataset that has undergone QA. The manual QA was developed during the OTD mission to identify artifacts that made it through ground processing algorithms. The manual QA process was continued for the TRMM and ISS LIS missions. Many anomalies have been identified and software updates now address many of them. However, some anomalies still occur in the processed datasets. The manual QA process examines the data for obvious issues in the lightning files that passed through the processing algorithms. These files are considered anomalous and are not included in the final QA dataset. Some issues that may cause an orbit to be considered anomalous include: obvious noise (excess events that make it through the processing), suspect geolocation, and excessive missing data packets. As an example, one way noise manifests is as “streaks” in lightning climatology plots. These streaks are especially apparent in low lightning rate regions (eg., over oceans). Since there is no method at present to extract these anomalies during processing, orbit files with significant anomalies are identified and removed from the final QA ISS LIS dataset. The final QA dataset can be obtained files from the Global Hydrometeorological Resource Center (GHRC). This presentation will provide examples of the various anomalies and examine how often the various anomalies occur and how much data is lost due to the omission of the anomalous orbits. Comparisons with OTD and TRMM LIS will also be examined.

ISS↗

In-Situ XRD/XRF to Support Life Detection on Mars

X-ray diffraction / X-ray fluorescence (XRD/XRF) analysis provides the most comprehensive mineralogical / compositional characterization of rocks and soils of any flight-capable technique. XRD data provide quantitative mineralogy (including abundance of X-ray amorphous materials) and crystal chemistry (structure, elemental composition and valence state), and XRF data provide complimentary major, minor, and some trace element abundances. Both types of data are important in evaluating habitability (environment of formation) and biosignature preservation/degradation (post-depositional diagenetic change). Whether or not a relict biosignature is detected, the mineral assemblage and its geochemistry can be used to determine the habitability of an ancient environment (e.g., salinity, pH, temperature), and to identify potential sources of energy for life (e.g., elements in different redox states). In this respect, a null result (a habitable environment lacking evidence of life) can play an important role in constraining the parameters of the search. Conversely, diagenetic alteration (taphonomic change) resulting from post-depositional variations in temperature, pressure or fluid chemistry can preserve evidence of biogenicity, erase such evidence completely or indeed can provide for post-depositional habitable conditions in the subsurface. XRD / XRF data are critical to these determinations. The CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover is the first XRD instrument flown in space. CheMin operates in transmission geometry with a Co X-ray source to minimize fluorescence from iron. Diffracted photons are collected with an energy-sensitive charge-coupled device (CCD). The position of the diffracted photons provides structural information for minerals, whereas the energy of sample-generated X-ray fluorescence photons provides elemental information, though these XRF data are qualitative. Mineralogical data from the CheMin XRD identified the three circumstances above: habitable depositional environments (e.g., Yellowknife Bay), habitable subsurface/diagenetic environments (e.g., throughout the Murray formation), and diagenetic conditions that may destroy evidence of habitability (e.g., oxidative and acidic environments at Vera Rubin ridge). Technological advances in X-ray technology and lessons learned from the operation of CheMin on Mars have resulted in a next-generation XRD/XRF, called CheMinX. Replacement of CheMin’s CCD with an array of hybrid pixel detectors and improvements in focusing optics dramatically decrease analysis time (15 minutes vs. 22 hours for MSL-CheMin) and result in a better angular resolution (0.18 vs. 0.30 °2θ for MSL-CheMin). This increased resolution improves mineral detection, including discrimination between types of pyroxenes, which is not possible with MSL-CheMin data. The hybrid pixel detectors do not require cooling like the MSL-CheMin CCD, therefore reducing the power needed to operate CheMinX. CheMinX has a silicon-drift detector (SDD) to measure fluoresced photons, enabling the quantification of major, minor, and some trace elements via XRF. XRD/XRF data are collected simultaneously in CheMinX, obviating the need for multiple compositional instruments. The CheMinX design also improves upon MSL-CheMin’s sample handling. Instead of sample cells on wheel, which are often not reusable and add complexity in commanding the instrument, CheMinX has single-use cells in a cartridge/dispenser configuration. Because of these improvements, CheMinX is an ideal instrument for Discovery-class life-detection missions, including Mars Life Explorer that was recommended for development in the Planetary Science and Astrobiology Decadal Survey 2023-2032.

E B Rampe↗