Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capillary Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Consumption study and identification of methyl salicylate in spicy cassava chips

Spicy cassava chips is a popular snack. However, some news in electronic media reported addition of balsam which is a banned food additives in that product to give extra spicy flavor. This study aimed to determine ITB students’ pattern of consumption, health problems caused by spicy chips consumption, and knowledge about illicit use of food additives in that product, and identify the main content of balsam namely methyl salicylate in 10 samples of spicy cassava chips taken from inside and outside about ITB campus. A total of 300 questionnaires distributed to ITB students then data processing was performed. Spicy cassava chips sample macerated in 50 mL of methanol for 24 hours at room temperature, filtered and analyzed using gas chromatography capillary column with OV-1, nitrogen carrier gas and flame ionization detector. Based on questionnaires, 292 (97%) of 300 respondents had consumed spicy chips. A total of 247 (85%) from 292 respondents spicy chips consumed less than 3 times a week. A total of 195 respondents (67%) had experienced health problems after eating spicy chips. There were 137 (47%) of the 292 respondents who knew about the illicit addition of food additives into spicy chips; only 35 respondents (12%) who knew about balsam’s addition. There were 126 respondents (43%) who did not pay attention to their health because they will keep eating spicy chips despite the addition of banned food additives. Through the verification of the standard addition method in gas chromatography system with a hydrogen pressure of 1.5 bar, injector temperature 200 °C, detector temperature 230 °C, oven temperature 60 °C for 2 minutes and then increased to 230 °C with rate 6 °C/menit; linearity, limit of detection, limit of quantitation, accuracy, precision, and specificity parameters met the acceptance limits. From 10 spicy cassava chips samples which were analyzed, they did not reveal any content of methyl salicylate. Methyl salicylate contained in the positive control was 1.273 mg/mL.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compressional wave velocity and effective stress in unsaturated soil: Potential application for monitoring moisture conditions in vadose zone sediments

Compressional seismic (P-wave) velocities were measured experimentally at different water potentials and confining pressure states using a variety of sediments collected from the US Department of Energy Hanford Site in southeastern Washington State. P-wave velocity was measured in variably saturated sediments using ultrasonic piezoelectric transducers and water potential was measured with a heat dissipation sensor. We propose a model to relate changes in P-wave velocity to soil stress conditions using an effective stress formulation that includes capillary stress as well as adsorptive stress. We show that compressional wave velocities can be related to water potential and confining stress using a model with five fitted parameters. A single set of parameters provides an excellent fit to data acquired from all of the sediment samples. Under very dry conditions, corresponding to low water potentials, water flow occurs in adsorptive thin films associated with very low unsaturated hydraulic conductivities. The results presented here suggest the utility of seismic methods for establishing low water potential and flow conditions within variably saturated Hanford formation sediments and providing feedback on the performance of mitigation efforts such as soil desiccation and surface infiltration barriers. Seismic methods can provide minimally invasive, three-dimensional information on relevant flow conditions in vadose zone sediments as well as changes that occur over time.

Linneman, Dorothy C.↗

Evaporative capillary instability for flow in porous media under the influence of axial electric field

We study the linear analysis of electrohydrodynamic capillary instability of the interface between two viscous, incompressible and electrically conducting fluids in a fully saturated porous medium, when the phases are enclosed between two horizontal cylindrical surfaces coaxial with the interface and, when there is mass and heat transfer across the interface. The fluids are subjected to a constant electric field in the axial direction. Here, we use an irrotational theory in which the motion and pressure are irrotational and the viscosity enters through the jump in the viscous normal stress in the normal stress balance at the interface. A quadratic dispersion relation that accounts for the growth of axisymmetric waves is obtained and stability criterion is given in terms of a critical value of wave number as well as electric field. It is observed that heat transfer has stabilizing effect on the stability of the considered system while medium porosity destabilizes the interface. The axial electric field has dual effect on the stability analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Field Test Report: NETL Portable Raman Gas Composition Monitor Initial Industrial tests at NETL and General Electric (GE)

NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented for spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.

25 ENERGY STORAGE↗

Field Test Report: NETL Portable Raman Gas Composition Monitor - Initial Industrial tests at NETL and General Electric (GE)

NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented for spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.

25 ENERGY STORAGE↗

Microbial Range Expansions on Liquid Substrates

Despite the importance of fluid flow for transporting and organizing populations, few laboratory systems exist to systematically investigate the impact of advection on their spatial evolutionary dynamics. To address this problem, we study the morphology and genetic spatial structure of microbial colonies growing on the surface of a nutrient-laden fluid 10 4 to 10 5 times more viscous than water in Petri dishes; the extreme but finite viscosity inhibits undesired thermal convection and allows populations to effectively live at the air-liquid interface due to capillary forces. We discover that S. cerevisiae (baker’s yeast) growing on a viscous liquid behave like “active matter”: They metabolically generate fluid flows many times larger than their unperturbed colony expansion speed, and that flow, in turn, can dramatically impact their colony morphology and spatial population genetics. We show that yeast cells generate fluid flows by consuming surrounding nutrients and decreasing the local substrate density, leading to misaligned fluid pressure and density contours, which ultimately generates vorticity via a thresholdless baroclinic instability. Numerical simulations with experimentally measured parameters demonstrate that an intense vortex ring is produced below the colony’s edge. As the viscosity of the substrate is lowered and the self-induced flow intensifies, we observe three distinct morphologies: At the highest viscosity, cell proliferation and movement produces compact circular colonies with, however, a stretched regime of exponential expansion; intermediate viscosities give rise to compact colonies with “fingers” that are usually monoclonal and then break into smaller cell clusters; at the lowest viscosity, the expanding colony fractures into many genetically diverse, mutually repelling, islandlike fragments that can colonize an entire 94-mm-diameter Petri dish within 36 hours. We propose a simple phenomenological model that predicts the early colony dynamics. Our results provide rich opportunities to study the interplay between fluid flow and spatial population genetics for future investigations.

36 MATERIALS SCIENCE↗

Confocal Raman Microscopy Investigation of the Wetting of Reversed-Phase Liquid Chromatographic Stationary Phase Particles

Wetting phenomena in reversed-phase liquid chromatographic (RPLC) stationary phase particles strongly influence the retention of solutes with high water-content mobile phases. To better understand these phenomena, this work reports the spectroscopic observation of the wetting of the interior of individual C 18 -silica stationary phase particles with acetonitrile–water mobile phase solutions by confocal Raman microscopy. It was found that the pores of dry C 18 silica do not wet when the concentration of acetonitrile is below 0.12 mol fraction (28% by volume). It was also found that there is a wetting hysteresis, where particles that had been previously exposed to acetonitrile solutions above the wetting transition remain filled with solution even at much lower concentrations of acetonitrile in the surrounding solution. Contact angles of acetonitrile–water solutions were measured at a planar C 18 -modified silica surface and used to predict the capillary wetting of the particles based on the Young–Laplace equation. The solution composition at the wetting transition detected by Raman microscopy is higher in acetonitrile concentration than predicted by the Young–Laplace equation, which may be due to the presence of a vapor or air gap at the interface between the hydrophobic pores and aqueous solution. Further evidence of this behavior is found in water porosimetry results, which show wetting pressures ~5 times greater than predicted by the Young–Laplace equation and are consistent with only 50% of a water interface being in contact with the C 18 surface. Furthermore, this fraction increases to 80% at an acetonitrile concentration of 0.12 mol fraction, leading to spontaneous and irreversible wetting of the hydrophobic pores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amphiphilic nanopores that condense undersaturated water vapor and exude water droplets

Condensation of water vapor in confined geometries, known as capillary condensation, is a fundamental phenomenon with far-reaching implications. While hydrophilic pores enable liquid formation from undersaturated vapor without energy input, the condensate typically remains confined, limiting practical utility. Here, we explore the use of amphiphilic nanoporous polymer-infiltrated nanoparticle films that condense and release liquid water under isothermal and undersaturated conditions. By tuning the polymer fraction and nanoparticle size, we optimize condensation and droplet formation. As vapor pressure increases, voids fill with condensate, which subsequently exudes onto the surface as microscopic droplets. This behavior, enabled by a balance of polymer hydrophobicity and capillarity, reveals how amphiphilic nanostructures can drive accessible water collection. Our findings provide design insights for materials supporting energy-efficient water harvesting and heat management without external input.

Science & Technology - Other Topics↗

Liquid Acquisition Strategies for Exploration Missions: Current Status 2010

NASA is currently developing the propulsion system concepts for human exploration missions to the lunar surface. The propulsion concepts being investigated are considering the use of cryogenic propellants for the low gravity portion of the mission, that is, the lunar transit, lunar orbit insertion, lunar descent and the rendezvous in lunar orbit with a service module after ascent from the lunar surface. These propulsion concepts will require the vapor free delivery of the cryogenic propellants stored in the propulsion tanks to the exploration vehicles main propulsion system (MPS) engines and reaction control system (RCS) engines. Propellant management devices (PMD s) such as screen channel capillary liquid acquisition devices (LAD s), vanes and sponges currently are used for earth storable propellants in the Space Shuttle Orbiter OMS and RCS applications and spacecraft propulsion applications but only very limited propellant management capability exists for cryogenic propellants. NASA has begun a technology program to develop LAD cryogenic fluid management (CFM) technology through a government in-house ground test program of accurately measuring the bubble point delta-pressure for typical screen samples using LO2, LN2, LH2 and LCH4 as test fluids at various fluid temperatures and pressures. This presentation will document the CFM project s progress to date in concept designs, as well ground testing results.

Chato, David J.↗

Lumped Parameter Models of the Central Nervous System for VIIP Research

INTRODUCTION: Current long-duration missions to the International Space Station and future exploration-class missions beyond low-Earth orbit, such as to Mars and asteroids, expose astronauts to increased risk of Visual Impairment and Intracranial Pressure (VIIP) syndrome [1]. It has been hypothesized that the headward shift of cerebral spinal fluid (CSF) and blood in microgravity may cause significant elevation of intracranial pressure (ICP), which in turn induces VIIP syndrome through biomechanical pathways [1, 2]. However, there is insufficient evidence to confirm this hypothesis. In this light, we are developing lumped-parameter models of fluid transport in the central nervous system (CNS) as a means to simulate the influence of microgravity on ICP. The CNS models will also be used in concert with the lumped parameter and finite element models of the eye described in the realted IWS abstracts submitted by Nelson et al., Feola et al. and Ethier et al. METHODS: We have developed a nine compartment CNS model (Figure 1) capable of both time-dependent and steady state fluid transport simulations, based on the works of Stevens et al. [3]. The breakdown of compartments within the model includes: vascular (3), CSF (2), brain (1) and extracranial (3). The boundary pressure in the Central Arteries [A] node is prescribed using an oscillating pressure function PA(t) simulating the carotid pulsatile pressure wave as developed by Linninger et al. [4]. For each time step, pressures are integrated through time using an adaptive-timestep 4th and 5th order Runga-Kutta solver. Once pressures are found, constitutive equations are used to solve for flowrates (Q) between each compartment. In addition to fluid flow between the different compartments, compliance (C) interactions between neighboring compartments are represented. We are also developing a second CNS model based on the works of Linninger et al. [4] which takes a more granular approach to represent the interactions of the intracranial and spinal compartments with the inclusion of arteries, arterioles, capillaries, venules, veins, venous sinus, and ventricles. The flow through the arteries, veins and CSF compartments are governed by continuity, momentum and distensibility balance equations. Furthermore, unlike the Stevens et al. approach, the Monro-Kellie doctrine of constant cranial volume and the bi-phasic nature of the brain parenchyma are implemented. These features appear to be more consistent with the physiologic and anatomical behavior of the CNS, and follow a modeling philosophy similar to the lumped parameter eye model that is intended to be integrated with the CNS model. However, Linninger’s approach has never been implemented to include hydrostatic gradient and microgravity simulation capabilities. Therefore, we aim at implement this modeling approach for spaceflight simulations and assess its overall applicability to VIIP research. OBJECTIVES: We will present verification and validation test results for both models, as well as head-to-head comparison to explore their strengths and limitations with respect to mathematical implementation and physiological significance for VIIP research. In doing so, we hope to provide some guidance to the HRP research community on how to appropriately leverage lumped parameter models for space biomedical research.

Vera, J.↗

A Local Condensation Analysis Representing Two-phase Annular Flow in Condenser/radiator Capillary Tubes

NASA's effort for the thermal environmental control of the Space Station Freedom is directed towards the design, analysis, and development of an Active Thermal Control System (ATCS). A two phase, flow through condenser/radiator concept was baselined, as a part of the ATCS, for the radiation of space station thermal load into space. The proposed condenser rejects heat through direct condensation of ATCS working fluid (ammonia) in the small diameter radiator tubes. Analysis of the condensation process and design of condenser tubes are based on the available two phase flow models for the prediction of flow regimes, heat transfer, and pressure drops. The prediction formulas use the existing empirical relationships of friction factor at gas-liquid interface. An attempt is made to study the stability of interfacial waves in two phase annular flow. The formulation is presented of a stability problem in cylindrical coordinates. The contribution of fluid viscosity, surface tension, and transverse radius of curvature to the interfacial surface is included. A solution is obtained for Kelvin-Helmholtz instability problem which can be used to determine the critical and most dangerous wavelengths for interfacial waves.

Karimi, Amir↗

Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source for Elemental Mass Spectrometry: Preliminary Parametric Evaluation and Figures of Merit

A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A flexible gas flow reaction cell for in situ x-ray absorption spectroscopy studies

A capillary-based sample environment with hot air blower and integrated gas system was developed at Diamond to conduct X-ray absorption spectroscopy (XAS) studies of materials under time-resolved, in situ conditions. The use of a hot air blower, operating in the temperature range of 298-1173 K, allows introduction of other techniques e.g. X-ray diffraction (XRD), Raman spectroscopy for combined techniques studies. The flexibility to use either quartz or Kapton capillaries allows users to perform XAS measurement at energies as low as 5600 eV. To demonstrate performance, time-resolved, in situ XAS results of Rh catalysts during the process of activation (Rh K-edge, Ce L{sub 3}-edge and Cr K-edge) and the study of mixed oxide membrane (La{sub 0.6}Sr{sub 0.4}Co{sub 0.2}Fe{sub 0.8}O{sub 3−δ}) under various partial oxygen pressure conditions are described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic Nucleation of Supercooled Melts and Measurement of the Surface Tension and Viscosity

We investigate the phenomenon of acoustic pressure-induced nucleation by using a novel approach involving the large amplitude resonant radial oscillations and collapse of a single bubble intentionally injected into a supercooled liquid. Using a combination of previously developed and proven techniques, the bubble is suspended in a fluid host by an ultrasonic field which supplies both the levitation capability as well as the forcing of the radial oscillations. We observe the effects of an increase in pressure (due to bubble collapse) in a region no larger than 100 microns within the supercooled melt to rigorously probe the hypothesis of pressure-induced nucleation of the solid phase. The use of single bubbles operating in narrow temporal and spatial scales will allow the direct and unambiguous correlation between the origin and location of the generation of the disturbance and the location and timing of the nucleation event. In a companion research effort, we are developing novel techniques for the non-contact measurements of the surface tension and viscosity of highly viscous supercooled liquids. Currently used non-invasive methods of surface tension measurement for the case of undercooled liquids generally rely of the quantitative determination of the resonance frequencies of drop shape oscillations, of the dynamics of surface capillary waves, or of the velocity of streaming flows. These methods become quickly ineffective when the liquid viscosity rises to a significant value. An alternate and accurate method which would be applicable to liquids of significant viscosity is therefore needed. We plan to develop such a capability by measuring the equilibrium shape of levitated undercooled melt droplets as they undergo solid-body rotation. The experimental measurement of the characteristic point of transition (bifurcation point) between axisymmetric and two-lobed shapes will be used to calculate the surface tension of the liquid. Such an approach has already been validated through the experimental verification of numerical modeling results. The experimental approach involves levitation, melting, and solidification of undercooled droplets using a hybrid ultrasonic-electrostatic technique in both a gaseous as well as a vacuum environment. A shape relaxation method will be investigated in order to derive a reliable method to measure the viscosity of undercooled melts. The analysis of the monotonic relaxation to equilibrium shape of a drastically deformed and super-critically damped free drop has been used to derive interfacial tension of immiscible liquid combinations where one of the component has high viscosity. A standard approach uses the initial elongation of a droplet through shear flows, but an equivalent method could involve the initial deformation of a drop levitated in a gas by ultrasonic radiation pressure, electric stresses, or even solid body rotation. The dynamic behavior of the free drop relaxing back to equilibrium shape will be modeled, and its characteristic time dependence should provide a quantitative means to evaluate the liquid viscosity.

Trinh, E. H.↗

Dean vortex-enhanced blood plasma separation in self-driven spiral microchannel flow with cross-flow microfilters

Point-of-care (POC) diagnostic devices have been developing rapidly in recent years, but they are mainly using saliva instead of blood as a test sample. A highly efficient self-separation during the self-driven flow without power systems is desired for expanding the point-of-care diagnostic devices. Microfiltration stands out as a promising technique for blood plasma separation but faces limitations due to blood cell clogging, resulting in reduced separation speed and efficiency. These limitations are mainly caused by the high viscosity and hematocrit in the blood flow. A small increment in the hematocrit of the blood significantly increases the pressure needed for the blood plasma separation in the micro-filters and decreases the separation speed and efficiency. Addressing this challenge, this study explores the feasibility of diluting whole blood within a microfluidic device without external power systems. This study implemented a spiral microchannel utilizing the inertial focusing and Dean vortex effects to focus the red blood cells and extract the blood with lower hematocrit. The inertial migration of the particles during the capillary flow was first investigated experimentally; a maximum of 88% of the particles migrated to the bottom and top equilibrium positions in the optimized 350 × 60 μm (cross-sectional area, 5.8 aspect ratio) microchannel. With the optimized dimension of the microchannel, the whole blood samples within the physiological hematocrit range were tested in the experiments, and more than 10% of the hematocrit reduction was compared between the outer branch outlet and inner branch outlet in the 350 × 60 μm microchannel.

Biochemistry & Molecular Biology↗

Experiment K-7-28: Lung Morphology Study

There are no previous studies investigating the effect of microgravity exposure during spaceflight on lung tissue. We examined the ultrastructure of the left lungs of 5 Czechoslovakian Wistar rats flown on the 13 day, 19+ hr. Cosmos 2044 mission, and compared them to 5 vivarium and 5 synchronous controls at 1-g conditions, and 5 rats exposed to 14 days of tail-suspension. Within 10 minutes of sacrifice by decapitation, the lungs were removed and immersed in 3% glutaraldehyde in 0.1M phosphate buffer (total osmolarity of the fixative: 560 mOsm; pH = 7.4). The tissue stored at 5 C was transported to our laboratory where it was processed for light and electron microscopy. No significant perivascular cuffing caused by interstitial edema was present in the tissue samples. Some of the flight, tail-suspended, and synchronous control rats showed alveolar edema, while vivarium controls did not. The pulmonary capillaries appeared to be more congested in the flight animals than in the other groups. This could be related to the increased hematocrit due to the microgravity exposure. In all 5 flight, 4 tail-suspended, and 3 synchronous rats, red blood cells (RBC) were present in the alveolar spaces. The RBC were either suspended free in the alveoli or observed lining the alveolar wall. The frequency of RBC lining the alveolar walls appeared greater in the dorsal (gravity non-dependent) than in ventral (gravity dependent) regions of the lung in these three animal groups. In 3 of the vivarium controls, a few RBC were found in the alveolar spaces. Intra-capillary fluid-filled vesicles were observed in the flight, tail-suspended and synchronous animals, but not in the vivarium controls. The formation of intra-capillary fluid-filled vesicles has been previously associated with pulmonary hypertension induced by high altitude exposure and mitral stenosis. In conclusion, pulmonary hemorrhage and alveolar edema of unknown origin occurred to a greater extent in the flight, tail-suspended, and synchronous control animals, and in the dorsal regions of the lung when compared to the vivarium controls. The etiology of these changes, which are possibly due to an increase in pulmonary vascular pressure, requires further investigation.

West, J. B.↗

Microchip capillary electrophoresis absent electrokinetic injection

Microchip capillary electrophoresis (CE) utilizing a sample injector based on a mechanical valve rather than electrokinetic injection can provide improved sample injections, enhanced capabilities, and can eliminate the need for changing the electric field in the separation channel to induce sample injection. In one instance CE electrodes continuously apply an electric field for CE separation along a separation channel. A sample channel is connected to the separation channel at an intersection and has a sample pressure that is greater than that which is present in the separation channel near the intersection. The sample channel does not have electrodes that apply voltages for electrokinetic injection. A sample injector in the sample channel or at the intersection comprises a mechanical valve to control sample injection from the sample channel to the separation channel.

Sun, Xuefei↗

Elastocapillary levelling of thin viscous films on soft substrates

A thin liquid film with nonzero curvature at its free surface spontaneously flows to reach a flat configuration, a process driven by Laplace pressure gradients and resisted by the liquid's viscosity. Inspired by recent progresses on the dynamics of liquid droplets on soft substrates, we here study the relaxation of a viscous film supported by an elastic foundation. Experiments involve thin polymer films on elastomeric substrates, where the dynamics of the liquid-air interface is monitored using atomic force microscopy. A theoretical model that describes the coupled evolution of the solid-liquid and the liquid-air interfaces is also provided. In this soft-levelling configuration, Laplace pressure gradients not only drive the flow, but they also induce elastic deformations on the substrate that affect the flow and the shape of the liquid-air interface itself. This process represents an original example of elastocapillarity that is not mediated by the presence of a contact line. We discuss the impact of the elastic contribution on the levelling dynamics and show the departure from the classical self-similarities and power laws observed for capillary levelling on rigid substrates.

42 ENGINEERING↗