Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Energy Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates, Cocoa, Florida

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heterogeneous damage in Li-ion batteries: Experimental analysis and theoretical modeling

We assess the heterogeneous electrochemistry and mechanics in a composite electrode of commercial batteries using synchrotron X-ray tomography analysis and microstructure-resolved computational modeling. We visualize the morphological defects at multi-scales ranging from the macroscopic composite, particle ensembles, to individual single particles. Particle fracture and interfacial debonding are identified in a large set of tomographic data of active particles. Mechanical failure in the regime near the separator is more severe than toward the current collector. The active particles close to the separator experience deeper charge and discharge over cycles and thus are more mechanically loaded. The difference in the Li activity originates from the polarization of the electrolyte potential and the non-uniform distribution of the activation energy for the charge transfer reaction. We model the kinetics of intergranular fracture and interfacial degradation to confirm that the various Li activities are the major cause of the heterogeneous damage. The interfacial failure may reconstruct the conductive network and redistribute the electrochemical activities that render a dynamic nature of electrochemistry and mechanics evolving over time in the composite electrode. We further quantify the influence of the mechanical damage on the metrics of battery performance. We simulate the electrochemical impedance profile to build a relationship between the interfacial debonding and the impedance of electron transport and surface charge transfer. Lastly, the mechanical failure disrupts the conduction path of electrons and results in significant polarization and capacity loss in batteries.

25 ENERGY STORAGE↗

Physiological Controls on Carbon Fluxes and Biomass Production in Miscanthus: Insights From a Process‐Based Agroecosystem Model

Biomass crops serve as essential feedstocks for renewable energy and bioproducts and play a critical role in achieving lower emissions in the transportation sector. However, dedicated perennial biomass crops such as Miscanthus × giganteus (Miscanthus) remain underrepresented in process-based agroecosystem models, limiting robust evaluation of their economic and environmental performance. In this study, we developed a data-constrained representation of the sterile triploid Miscanthus (IL clone) within the process-based model ecosys, integrating global sensitivity analysis, ensemble simulation, and parameter calibration. Planting, harvesting, and fertilization practices consistent with field management were incorporated, and phenology was constrained using PhenoCam-derived Green Chromatic Coordinate (GCC) data. Using the Morris global sensitivity analysis method, we identified 11 key physiological parameters governing plant carbon, water, and nutrient relations, particularly processes associated with CO 2 assimilation. We then conducted ensemble simulations by perturbing these parameters and calibrated the model against eddy covariance fluxes and field-measured biomass. Building on the calibrated operating state, parameter-response analyses show that different photosynthetic processes influence productivity in different ways. Protein allocation determines whether productivity increases toward a higher level, whereas electron transport capacity controls additional gains once protein allocation approaches saturation. These findings demonstrate that parameter importance depends on physiological context and on which photosynthetic processes remain limiting. Calibration and validation against observations show that ecosys can reliably reproduce carbon and water fluxes, as well as both above- and belowground biomass, with post-calibration GPP R 2 improving from 0.67 to 0.95 during the calibration period and remaining high during validation (R 2 = 0.95). These results provide a mechanistic foundation for regional simulations and sustainable bioenergy assessments.

ecosys↗

A Scalable Compact Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger for Solar Thermal Application

Design of an additively manufactured molten salt (MS) to supercritical carbon dioxide (sCO 2 ) primary heat exchanger (PHE) for solar thermal power generation is presented. The PHE is designed to handle temperatures up to 720 °C on the MS side and an internal pressure of 200 bar on the sCO 2 side. In the core, MS flows through a three-dimensional periodic lattice network, while sCO 2 flows within pin arrays. The design includes integrated sCO 2 headers located within the MS flow, allowing for a counterflow design of the PHE. The sCO 2 headers are configured to enable uniform flow distribution into each sCO 2 plate while withstanding an internal pressure of 200 bar and minimizing obstruction to the flow of MS around it. The structural integrity of the design is verified on additively manufactured (AM) 316 stainless steel sub-scale specimens. An experimentally validated, correlation-based sectional PHE core thermofluidic model is developed to study the impact of flow and geometrical parameters on the PHE performance, with varied parameters including the mass flowrate, surface roughness, and PHE dimensions. A process-based cost model is used to determine the impact of parameter variation on build cost. The model results show that a heat exchanger with a power density of 18.6 MW/m 3 (including sCO 2 header volume) and effectiveness of 0.88 can be achieved at a heat capacity rate ratio of 0.8. As a result, the impact of design and AM machine parameters on the cost of the PHE are assessed.

14 SOLAR ENERGY↗

Supply Chain for Photovoltaics in the United States: 2024 in Review

Solar photovoltaic (PV) and battery energy storage system (BESS) technologies are two immediately available options for meeting U.S. electricity demands, which are increasing due to expansion of loads from end uses including data centers, buildings, vehicles, and factories. Globally, PV and BESS supply chains are dominated by products manufactured in China and elsewhere by Chinese companies. However, U.S. PV and BESS manufacturing have recently grown, with some capacity in each step of the PV supply chain, albeit not enough to currently meet demand with domestic manufacturing alone. This study analyzes U.S. PV supply chains and costs in 2024, for the crystalline silicon and cadmium telluride module supply chains. The full report additionally addresses the PV balance of system, inverter and BESS supply chains. The study concludes with an analysis of technology installation trends, government support for domestic manufacturing, manufacturing jobs, and the domestic content of PV systems installed in the United States in 2024.

14 SOLAR ENERGY↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗

Feasibility and strategic implications of deploying nuclear power reactors in Africa

This report assesses the feasibility and strategic implications of deploying nuclear power reactors, including large-scale plants, advanced small modular reactors (SMRs), and microreactors, in African countries. Case studies focus on South Africa, Egypt, Kenya, Ghana, and Nigeria, examining nuclear energy’s role in Africa’s rapidly evolving energy landscape, marked by fast-growing demand, significant electricity access gaps, increasing renewable penetration, and strong policy commitments to industrialization and energy security. Several U.S. reactor technologies and designs are considered based on their development status and readiness for deployment. The analysis finds that nuclear power can provide reliable, clean baseload and flexible generation, as well as high-temperature process heat for desalination, hydrogen production, and industrial applications. However, suitability is highly country-specific, depending on grid size and stability, transmission capacity, cooling water availability, regulatory readiness, and fuel supply chains. Near-term deployment opportunities are strongest for light-water reactors (such as NuScale, BWRX-300, AP300, and SMR-300) that use low-enriched uranium and build on proven technology. More advanced concepts, including gas-cooled, sodium-cooled, molten-salt cooled reactors, and microreactors, will likely be relevant for African deployment in the 2030s or later, contingent on demonstration projects, high-assay low-enriched uranium (HALEU) fuel availability, and mature international licensing frameworks. Economic analysis shows that SMRs are capital-intensive, with projected overnight costs for 300 MWe units in 2025 ranging from approximately 1.4 to 2.6 billion USD per module. The levelized cost of electricity (LCOE) is highly sensitive to the weighted average cost of capital (WACC). Given typically higher financing costs and utility balance-sheet weaknesses in many African countries, bankable project structures will require sovereign guarantees, robust offtake arrangements, and layered financing from export credit agencies, development finance institutions, and vendor nations. Comparisons with recent large nuclear projects in the United Arab Emirates (UAE) and Egypt underscore the central role of state-backed loans, long tenors, and concessional terms. Country case studies illustrate a spectrum of readiness and opportunity. South Africa operates two 920 MWe pressurized light water reactors (totaling 1,840 MWe) at Koeberg and has the most mature regulatory and industrial base, positioning it as a prime candidate for both large reactors and SMRs to replace coal, support desalination, and anchor industrial hubs. Egypt is constructing four VVER-1200 units at El Dabaa with strong state leadership and could later complement this fleet with SMRs for coastal and industrial applications. Kenya and Ghana are advancing through IAEA Milestones with growing institutional capacity and clear interest in SMRs that match their smaller grids and industrialization plans. Nigeria has the largest demand potential but faces acute constraints in grid reliability, project bankability, and regulatory capacity; targeted deployments of large reactors and SMRs near coastal or industrial sites could have high impact if accompanied by major grid upgrades and institutional reforms. The report identifies cross-cutting challenges such as financing, political continuity, public acceptance, nonproliferation and security, waste and back-end management, regulatory capacity, grid adequacy, and long deployment timelines for first-of-a-kind designs, and ANL/NSE-26/3 ii proposes broad directions for resolution. These include stronger multifaceted financing for nuclear, long-term national energy strategies that transcend electoral cycles, proactive stakeholder engagement, strengthened regional and national regulators, and systematic workforce development through centers of excellence and expanded training. The United States should develop partnerships with African countries and offer end-to-end nuclear package similar to those used effectively by competitors: coordinated project development, state-backed financing, long-term fuel services, and durable in-country support through regional offices and sustained workforce/regulatory training. With timely planning, sustained political commitment, and appropriate financing and institutional support, nuclear energy, both large reactors and advanced SMRs, can become a meaningful, though not dominant, pillar of Africa’s future power mix, enhancing energy security, enabling industrial growth, and supporting climate goals.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Offshore Renewable Energy R&D (Fact Sheet)

This fact sheet describes the offshore renewable energy R&D efforts at NREL's NWTC. As the United States increases its efforts to tap the domestic energy sources needed to diversify its energy portfolio and secure its energy supply, more attention is being focused on the rich renewable resources located offshore. Offshore renewable energy sources include offshore wind, waves, tidal currents, ocean and river currents, and ocean thermal gradients. According to a report published by the National Renewable Energy Laboratory (NREL) in 2010,1 U.S. offshore wind resources have a gross potential generating capacity four times greater than the nation's present electric capacity, and the Electric Power Research Institute estimates that the nation's ocean energy resources could ultimately supply at least 10% of its electric supply. For more than 30 years, NREL has advanced the science of renewable energy while building the capabilities to guide rapid deployment of commercial applications. Since 1993, NREL's National Wind Technology Center (NWTC) has been the nation's premier wind energy research facility, specializing in the advancement of wind technologies that range in size from a kilowatt to several megawatts. For more than 8 years, the NWTC has been an international leader in the field of offshore floating wind system analysis. Today, researchers at the NWTC are taking their decades of experience and extensive capabilities and applying them to help industry develop cost-effective hydrokinetic systems that convert the kinetic energy in water to provide power for our nation's heavily populated coastal regions. The center's capabilities and experience cover a wide spectrum of wind and water energy engineering disciplines, including atmospheric and ocean fluid mechanics, aerodynamics; aeroacoustics, hydrodynamics, structural dynamics, control systems, electrical systems, and testing.

14 SOLAR ENERGY↗

Residential Battery Modeling for Control-Oriented Techno-Economic Studies: Preprint

Electrochemical batteries, which serve as electric energy storage devices, are becoming increasingly popular among residential buildings that incorporate solar photovoltaic (PV) systems to help meet their energy needs. Battery economics are affected by performance degradation over time, and managing this degradation can help extend the battery's lifespan. The tradeoff between operational costs/benefits and managing battery degradation is of significant research interest. One of the key factors for assessing battery degradation is the dispatch strategy used to control the charging and discharging of the battery. Conventional dispatch strategies typically use simple rule-based methods, and these overly aggressive charging/discharging cycles can significantly reduce a battery’s life span. Our research seeks to develop optimized dispatch strategies for grid-connected PV homes with a goal of extending battery life while simultaneously taking into consideration utility costs and occupant comfort. To achieve this goal, we adapted lithium-ion battery life- and cyclic-degradation models for use in high-fidelity building simulations, so whole-building and grid-interactive controllers can dispatch the batteries along with other flexible loads. With the help of a co-simulation platform, we performed a simulation study to compute the optimized dispatch strategies for relevant operating conditions brought about by changing geographical locations, weather conditions, and utility pricing. Comparing the optimized strategies with the conventional strategies resulted in a >50% decrease in capacity degradation and >10% average reduction in operational costs during the months of January and July in Fort Collins, Colorado; Phoenix, Arizona; and Portland, Oregon.

30 DIRECT ENERGY CONVERSION↗

Sharing the Sun: Community Solar Deployment and Subscriptions (As of January 2026)

The community solar market analysis presented here is based primarily on data collected through Sharing the Sun, an initiative of the National Community Solar Partnership+ (NCSP+). Sharing the Sun data collection and analysis are conducted by the National Laboratory of the Rockies (NLR) as part of its support for implementation of NCSP+. NLR first released a dataset of community solar projects in 2018 and updates it biannually. The January 2026 dataset, data collection methodology, and all the previous datasets are available from NLR's Data Catalog: https://data.nlr.gov/submissions/244. The dataset presents project-level information including location, capacity, operating utility, and year of interconnection. The dataset is created from multiple data sources such as utility data, public utility commissions, project developer websites, media releases, primary data collection by NLR, and data provided by developers under nondisclosure agreements. This presentation builds on a previous analysis of the community solar project dataset, Sharing the Sun: Community Solar Deployment and Subscriptions (as of June 2024). Dr. Gabriel Chan and his team at the University of Minnesota contribute to this effort. NCSP+ is led and funded by U.S. Department of Energy's Integrated Energy Systems Office (IESO).

14 SOLAR ENERGY↗

Cladding Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet)

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. The location of the insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. For thick layers of exterior insulation (more than 1.5 in.), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. Although the approach has proven effective, there is significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying Resolution Implications for Agent-based Distributed Energy Resource Customer Adoption Models

In this report we explore tradeoffs of top-down and bottom-up methods in their precision and computational burden using NREL's dGen model, an agent-based model of residential and non-residential distributed PV adoption. In particular, we assess the role of agent resolution in instantiating statistically-representative populations in the model--and the resulting variance of model projections at the state, sector and county levels. Running the model for a single state with fixed macroeconomic assumptions, we vary both the number of agents instantiated and the number of unique simulations. Notably, in each run we introduce sources of uncertainty in cumulative DPV adoption results during agent instantiation as we stochastically sample agent attributes from localized building characteristic and solar resource distributions. We find three key trends which guide what can be expected of results. First, precision of the model projections, as measured by the variance of the unique simulations increased as a function of the number of agents sampled, though with diminishing returns to scale. The result is expected given the Law of Large Numbers. Second, the mean or expected value of projections decreased as the number of agents instantiated increased. Empirically, aggregate DPV capacities projected by dGen are 7% lower on average at a 10-agent resolution compared to 1-agent resolutions, and up to 10% lower in the non-residential sector. We attribute this outcome to a system sizing scheme that biases lower cumulative installed capacity as agent resolution increases when roof size and load are not positively correlated. Finally, the variance of model projections differed by sector, where variance was substantially larger in the commercial sector, largely due to differences in parameterization by sector. We explain the larger variance in the non-residential sector as an outcome of the greater variance in building uses and load shapes as compared to the residential sector, and we find that a resolution on the order of 100-agents per county would be necessary to bring non-residential variance in line with residential variance at a 2-agent resolution. We propose that further research explore increasing precision and agent resolution in the non-residential sector. Moreover, given that days of intensive computing may be required to resolve a suitable estimate even at the extent of a single state within acceptable levels of precision, to promote computational efficiency we also suggest more clearly quantifying sources of variability at the county level such that resolution can by dynamically increased where county level results are least precise.

14 SOLAR ENERGY↗

Mesoporous TiO2 spheres with a nitridated conducting layer

Nitridated TiO2 mesoporous spheres have been synthesized by hydrothermal processing followed by post-nitridation with NH3. Characterization data reveal a nitridated conducting layer, in addition to a mesoporous, and nanosized building-block morphology resulting in a large surface area. The samples have an average pore size and surface area of, respectively, 10 nm and 87 m2/g. The nitridated TiO2 mesoporous spheres exhibit a high capacity of > 200 mAh/g with good cyclability and high rate capability, as the nitridated conducting layer and favorable morphology of nanosized spheres provides good electrical contact, accommodates cycling induced strain smoothly, and facilitates lithium-ion diffusion.

anode↗

An assessment of the economic impact of the wind turbine supply chain in Illinois

The enormous growth of wind energy in Illinois and around the country has led to a shortage of wind turbines. Turbine manufacturers have sold out their capacity into 2010. To the extent that Illinois manufacturing can integrate itself into the wind turbine supply chain, Illinois can enjoy the economic benefits from both having wind farms and supplying the parts to build them. (author)

17 WIND ENERGY↗

Assembling Si 2 BN nanoribbons into a 3D porous structure as a universal anode material for both Li- and Na-ion batteries with high performance

The development of anode materials is critical to the success of sodium ion batteries (SIBs). Because of the size difference between Li and Na, the commercial anode material graphite in Li-ion batteries does not work for Na-ion batteries. Thus, it will be ideal if some universal anode materials could work for both Li- and Na-ion batteries with high performance. Inspired by a recent study on the high performance of a 2D-Si 2 BN sheet as an anode material for Li-ion batteries, we design a three dimensional (3D) porous structure by using the nanoribbons of a Si 2 BN sheet as building blocks. Based on the state-of-the-art ab initio calculations, we find that the resulting 3D porous Si 2 BN structure is stable chemically, dynamically and thermally, exhibiting a high specific capacity of 512.42 (341.61 mA h g -1 ), a low voltage of 0.27 V (0.15 V), a small volume expansion of 2.5% (2.7%), and a low migration energy barrier of 0.44 eV (0.19 eV) for Li- (Na-) ion batteries. Finally, these intriguing features, together with the light mass and rich abundance of Si, B and N, suggest that the 3D porous Si2BN structure is a promising candidate for the anode material of both Li- and Na-ion batteries.

36 MATERIALS SCIENCE↗

Commercial Vehicle Electrification Evaluation Toolkit (CVEET)

The CVEET can identify and characterize charging and battery capacity challenges for class 3-8 commercial vehicle electrification, including battery electric and plug in hybrid vehicles for various trucks, vans and buses, over a wide range of vehicle operation. The tool can help build the understanding of the impact of commercial vehicle electrification on energy consumption, payload penalty, and GHG (i.e., CO2) emissions. The tool employs a quantitative approach to estimate electric vehicle energy consumption, characterize component performance and determine appropriate charging assumptions to conduct a comprehensive priority analysis of MD/HD vehicle electrification using public domain data.

Gao, Zhiming↗