Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

3-D composite anodes for Li-ion batteries with high capacity and fast charging capability

A lithium-ion battery includes an electrode with a plurality of channels formed at least partially through its thickness. Each channel has a diameter in a range from 5 μm to 100 μm and/or is spaced apart from another channel by a distance in a range from 10 μm to 200 μm as measured between centerlines of the channels. The electrode may be an anode and includes carbonaceous material such as graphite and/or additional electrochemically active lithium host materials. The battery can be charged at a C-rate greater than 2 C.

Chen, Kuan-Hung↗

Quantifying the Solar Energy Resource for Puerto Rico

After Hurricane Maria, multiple U.S. Department of Energy laboratories studied the state of the electric grid in Puerto Rico and analyzed grid resilience and grid integration of renewable energy. As part of the work done at the National Renewable Energy Laboratory, researchers created new solar resource data, conducted a technical potential and supply curve analysis, and studied the interannual variability of the solar resource. A new methodology was developed to downscale solar resource data from the National Solar Radiation Data Base (NSRDB) from a 4-km x 4-km spatial and 30-minute temporal resolution to a 2 km x 2 km and 5-minute resolution. This methodology primarily used simple physical principles to develop high-resolution cloud properties which were then used to compute solar radiation. The high-resolution datasets were validated against ground measurements and the error metrics were found to be similar to the original lower resolution dataset. Using 20 years of downscaled data from the NSRDB multi-year capacity factors for photovoltaics (PV) were developed for both single-axis tracking and fixed latitude-tilt configurations. Use of the multi-year data provides the ability to understand variability in capacity factors due to variability in weather over a long period of time. For Puerto Rico the coastal regions were found to have significant higher capacity factors than inland. Using land-use and terrain information a technical potential analysis was conducted for Puerto Rico. This analysis restricted single PV plant development to a maximum of 100 MW nameplate capacity. The nameplate capacity for each municipality were then determined. Based on our assumptions, 56 of the 78 total municipalities of Puerto Rico contain some level of solar capacity. Most of the interior municipalities did not have any capacity because of the geographic exclusions used in this study. The lowest capacity for a PV plant observed in a municipality was 10 MW. The maximum capacity within a county was 2,000 MW. Further a supply curve analysis was conducted by taking the results of the technical potential and quantifying system and transmission costs. The levelized cost of energy (LCOE) was calculated for each theoretical PV plant site, and the levelized cost of transmission was added to the LCOE to produce a total cost estimate for each site. The results of the supply curve analysis allow for a relative comparison of the cost for integrating new PV capacity into the grid. This analysis indicates that cheaper total LCOE sites tend to be larger in capacity. The total capacity in this study was found to be far beyond the maximum peak load for the island. However, this study does not consider the economic and market potential for development. The cumulative capacity presented in this study assumes that the best locations are developed first and ignores the complex decision paths for new power plant development. Therefore, this analysis can only be treated as illustrative. Finally this study investigates the impact of inter-annual variability of resource using a variety of metrices including probability of exceedance and variation in capacity factor and LCOE. This study demonstrates that the capacity factor or LCOE could vary by over 10% year to year. This clearly indicates the risks involved in using any particular year of data and clearly points to the use of multi-year data to reduce some of the risks related to variability in weather.

14 SOLAR ENERGY↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2023 Edition [Slides]

Improving battery technology and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes “co-located hybrids” that pair two or more resources (e.g., multiple types of generation and/or generation with storage) that are operated largely independently behind a single point of interconnection, and “full hybrids” that also feature coordinated operations of the co-located resources. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis. Key findings from the latest briefing include: -At the end of 2022, there were 374 hybrid plants (>1 MW) operating across the United States (+25% compared to the end of 2021), totaling nearly 41 GW of generating capacity (+15%) and 5.4 GW/15.2 GWh of energy storage (+69%/+88%). PV+storage plants are by far the most common, dominating in terms of plant number (213), storage capacity (4.0 GW/12.5 GWh), storage:generator capacity ratio (49%), and storage duration (3.1 hours). But there are nearly twenty other hybrid plant configurations as well, including several different fossil hybrid categories (each dominated by the fossil component) as well as wind+storage, wind+PV, wind+PV+storage, geothermal+PV, and others. -Last year was another strong year for PV+storage hybrids in particular: 59 of the 62 hybrids added in 2022 were PV+storage. As of the end of 2022, there was roughly as much storage capacity operating within PV+storage hybrid plants as in standalone storage plants (~4 GW each). In storage energy terms, however, PV+storage edged out standalone storage by ~2 GWh (12.5 GWh vs. 10.4 GWh, respectively). -Interconnection queue data show continued strong developer interest in hybridization. At the close of 2022, there were 51% more hybrid plants—representing 59% more generating capacity—in interconnection queues across the United States than there were at the end of 2021. Solar dominates these proposed plants as well: at the close of 2022, there were 457 GW of solar capacity proposed as a hybrid (representing ~48% of all solar capacity in the queues), most typically pairing PV with battery storage. At the same time, there were 24 GW of wind capacity proposed as a hybrid (representing ~8% of all wind capacity in the queues), again most-often pairing wind with storage. Meanwhile, more than half of all storage in the queues is estimated to be part of a hybrid plant. While many of the plants proposed in the queues will not ultimately reach commercial operations, the depth of interest in hybrid plants—especially PV+storage—is notable, particularly in certain regions. For example, in CAISO, 97% of all solar capacity and 45% of all wind capacity in the queues is proposed as a hybrid. -The report also surveys power purchase agreement (PPA) price data from a sample of operating and proposed PV+storage plants. Though PV+storage PPA prices have fallen over time, “levelized storage adders” have recently increased somewhat to ~$\$ $7000/MW-month, ~$\$ $60/MWh-stored (assuming one full cycle per day), or ~$\$ $15/MWh-PV. Some of the recent price increase could simply reflect a trend towards higher battery:PV capacity ratios over time, which increases costs, all else being equal. The well-publicized impact of inflationary and supply chain pressures on battery prices is no doubt a contributor as well.

25 ENERGY STORAGE↗

Managing Solar Photovoltaic Integration in the Western United States: Resource Adequacy Considerations

This study examines the impact of reserve margin-based reliability assessment, as commonly used in capacity expansion models, on planning resource-adequate power systems under high penetrations of solar photovoltaics (PV). As a generation resource, PV is operationally different from the conventional dispatchable resources for which most capacity expansion models were designed. The question this study attempts to answer is whether large amounts of PV on a system (in this case, the Western Interconnection of North America) would bias the results of conventional reserve margin-based capacity expansion modeling towards an over- or under-provisioning of resource adequacy. This analysis used NREL’s Resource Planning Model (RPM) for capacity expansion modeling and NREL’s Probabilistic Resource Adequacy Suite (PRAS) for resource adequacy assessment. RPM uses a reserve margin requirement to enforce resource adequacy. PRAS, a collection of tools for studying the resource adequacy of power systems and the adequacy contributions of individual resources on a probabilistic basis, was used to compute multiple resource adequacy metrics across a number of simulated scenarios and system representations with differing regional detail. In all cases, including high PV penetrations (up to 33% annual generation from PV, interconnection-wide), RPM was able to produce resource-adequate systems as measured by normalized expected unserved energy and loss-of-load expectation results from PRAS. The accuracy of reserve margin approaches depends heavily on the underlying assumptions informing the capacity credit assigned to variable and energy-limited resources, particularly when such resources are abundant in the modeled system. RPM’s standard methodology for estimating variable and flexible resources’ capacity contributions, which is based on the top 100 hours of net load, did not appear to systematically undervalue or overvalue variable generation relative to a more rigorous equivalent firm capacity assessment using PRAS, although both over- and under-valuations were observed in specific scenarios. In the worst cases, the top 100 hour method underestimated the equivalent firm capacity of PV by two percentage points, and overestimated the equivalent firm capacity of PV by five percentage points. Calculating capacity contributions based on the top 10 hours of net load systematically underestimated equivalent firm capacities at more modest PV penetrations, but was often a better approximation of equivalent firm capacity than the existing 100-hour approach in scenarios with higher PV penetrations.

14 SOLAR ENERGY↗

A Highly Effective Polysulfide-Trapping Approach for the Development of High Energy Density, Scalable Lithium-Sulfur Batteries

Lithium-sulfur (Li-S) batteries are identified as one of the most promising next-generation battery technologies owing to their high theoretical specific energy, sustainability, and affordability. However, the commercialization of Li-S batteries has been hindered by severe technical challenges, including the lithium polysulfide (PS) dissolution/shuttling effect, a major cause of fast capacity degradation over cycling. We demonstrated that, for the first time, nanolayer polymer coated high surface area porous carbons (NPCs) were coated directly on sulfur electrodes (NPC-S), which led to a high specific capacity of ∼1,600 mAh g −1 approaching the theoretical specific capacity limit in the NPC-S based Li-S batteries. The NPC-S based Li-S batteries maintained their large initial specific capacity gain compared with the Baseline-S based Li-S batteries (control) over extended cycles. A follow-on study indicated that the NPC-S approach is a necessary and critical step to boost the near-theoretical specific capacity while being stabilized over long cycles with a synergistic strategy. Our experimental and computational results suggest that NPC coated on sulfur electrodes provides not only an effective and strong PS-trapping power but also an increased redox reaction kinetics for sulfur ↔ PS’s conversions during battery charge and discharge, rendering the realization of near-theoretical discharge specific capacity in the NPC-S based Li-S batteries. The findings presented in this study may inspire a new, simple, low-cost, and commercially scalable approach, without adding any appreciable dead weight or volume to the batteries, in the effort to tackle the technical challenges facing SOA Li-S batteries.

25 ENERGY STORAGE↗

Active Reconditioning of Retired Lithium-ion Battery Packs from Electric Vehicles for Second Life Applications

Utilizing the remaining capacity in retired lithium-ion (Li-ion) batteries from electric vehicles (EVs) for second-life applications has shown economic and environmental benefits. However, achieving homogeneity among the capacities of cells before their second life is critical to exploit the benefits. This article proposes a new active reconditioning approach with the potential to make short-term reconditioning of batteries before second life feasible. A control objective map determines each cell's state-of-charge (SOC) operating window based on its capacity relative to other cells. The SOC reference translates into distinct differential currents through the cells, wherein the higher-capacity cells undergo more frequent and deep charge and discharge cycles than their lower-capacity counterparts. The proposed solution achieves capacity homogeneity within the battery pack with low reconditioning time and minimal fade in the overall pack capacity. The feasibility of the reconditioning approach under varying load and environmental conditions is assessed through simulations, encompassing factors such as the number of cycles per day, depth-of-discharge, battery pack temperature, and cell resting time at different SOCs. Furthermore, the simulation model employs a battery pack with sixteen series-connected 75 Ah Kokam lithium nickel manganese cobalt oxide (NMC) cells with a 3.6% initial capacity imbalance. A reconditioning time of 1.3 months is achieved with a final capacity imbalance of 0.1% and an overall capacity fade of 0.005%, thereby confirming the viability of the reconditioning process. Moreover, experimental validation using eight retired battery cells from a Nissan Leaf demonstrates a substantial decrease in the capacity imbalance of cells from 9.4% to 2.15% within 78 days, effectively affirming the efficacy of the proposed reconditioning scheme.

25 ENERGY STORAGE↗