Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes

PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Embolization of Type II Endoleaks after EVAR: The Role of Ethylene Vinyl Alcohol Copolymer (Onyx)

Purpose: To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx). Methods: Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37-83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinical success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans. Result: Mean follow-up time was 26.0 (range 6-50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels. Conclusion: Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrospective review of thoracic neural damage during lung ablation - what the interventional radiologist needs to know about neural thoracic anatomy

Background and Purpose: Radiofrequency ablation (RFA) is associated with low neural morbidity compared with surgery, which commonly causes debilitating long-term pain. The purpose was to review the thoracic neural anatomy relevant to percutaneous RFA and to retrospectively review symptomatic nerve injury after lung RFA at our institution. Materials and Methods: We retrospectively examined all symptomatic nerve injuries occurring after computed tomography (CT)-guided RFA treatment of lung tumors for 462 patients/509 procedures/708 lesions treated at our large tertiary referral centre during 10 years. Results: Eight patients experienced neurological complications after heating during the RFA procedure. These complications occurred in the phrenic (n = 1), brachial (n = 3), left recurrent (n = 1), and intercostal nerves (n = 2) and the stellate ganglion (n = 1). Three were grade 2, four grade 3 and one grade 4 injuries (CTCAE v3). Conclusion: Although rare, neurological complications can occur after RFA, and they can occasionally be severe. To prevent these complications, it is important for the interventional radiologist to be aware of the anatomy of nervous structures and to attempt to identify nerves on CT scans during the RFA procedure. Creating a pneumothorax can be useful to avoid nerve damage and related clinical complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfissural Route Used for Preoperative Localization of Small Pulmonary Lesions with a Short Hook Wire and Suture System

PurposeWe retrospectively evaluated the results of the transfissural route for preoperative localization with a short hook wire and suture system for video-assisted thoracoscopic surgery (VATS).MethodsEleven patients with 11 tumors underwent CT-guided transfissural placement of a hook wire before VATS. This route was selected for all patients, because the distance between the tumor and interlobar fissure was much shorter than the required distance traversed using the conventional approach. Complications were evaluated using the National Cancer Institute Common Terminology Criteria for Adverse Events Version 4.0.ResultsThe hook wire was successfully placed using the transfissural route in all but one case. Of these ten successful placements, two tumors needed a second puncture for optimal placement, because the CT scan showed that the first hook wire was not properly placed in the lung. In one patient, we did not attempt replacement after the first placement was incorrect. In ten successful procedures, the mean distance traversed in the parenchyma of the unaffected lung lobe was 27.9 mm. The distance between the pleura and placed hook wire was significantly shorter than the estimated distance between the pleura and hook wire using the conventional route (mean 16.3 vs. 40.9 mm; P = 0.0002). Grade 1 adverse events occurred (11 pneumothoraxes and 4 pulmonary hemorrhages). No grade 2 or higher adverse event was observed.ConclusionsThe transfissural route used for preoperative localization before VATS is useful for selected patients because this route may allow for more limited lung parenchyma resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Superior Mesenteric Venous Thrombosis: Transcatheter Thrombolysis and Aspiration Thrombectomy Therapy by Combined Route of Superior Mesenteric Vein and Artery in Eight Patients

PurposeTo assess the feasibility, effectiveness, and safety of catheter-directed thrombolysis and aspiration thrombectomy therapy by combined route of superior mesenteric vein and artery (SMV+SMA) for acute superior mesenteric venous thrombosis (ASMVT).MethodsThis retrospective study reviewed eight ASMVT patients with transcatheter direct thrombolysis and aspiration thrombectomy therapy via SMV and indirect thrombolysis via SMA during a period of 14 months. The demographics, etiology, risk factors, therapeutic effect, complications, mortality, and follow-up of the study population were assessed. Anatomic and imaging classification of location and extent of thrombus at diagnosis and degree of thrombus lysis were described.ResultsTechnical success was achieved with substantial improvement in symptoms and thrombus resolution after thrombolytic therapy in all patients. The local urokinase infusion by SMA and SMV was performed for 5–7 (6.13 ± 0.83) and 7–15 (12 ± 2.51) days. Anticoagulation was performed catheter-directed and then orally throughout hospitalization and after discharge. Four patients required delayed localized bowel resection after thrombolytic therapy with no death. Thrombolytic therapy was not interrupted despite minor bleeding at the puncture site in two patients and sepsis in another two postoperatively. Nearly complete removal of thrombus was demonstrated by contrast-enhanced CT scan and portography before discharge. Patients were discharged in 10–27 (19.25 ± 4.89) days after admission. No recurrence developed during the follow-up of 10–13 (12.13 ± 0.99) months.ConclusionsCatheter-directed thrombolytic and aspiration therapy via SMV+SMA is beneficial for ASMVT in avoiding patient death, efficient resolving thrombus, rapid improving symptoms, reversing extensive intestinal ischemia, averting bowel resection, or localizing infarcted bowel segment and preventing short bowel syndrome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory-Induced Haemodynamic Changes: A Contributing Factor to IVC Filter Penetration

PurposeThe purpose of the study is to evaluate the influence of respiratory-induced vena caval hemodynamic changes on filter migration/penetration.Materials and MethodsAfter placement of either a Gunther Tulip or Celect IVC filter, 101 consecutive patients scheduled for filter retrieval were prospectively enrolled in this study. Pre-retrieval CT scans were used to assess filter complications and to calculate cross-sectional area in three locations: at level of filter strut fixation, 3 cm above and 3 cm below. A 3D finite element simulation was constructed on these data and direct IVC pressure was recorded during filter retrieval. Cross-sectional areas and pressures of the vena cava were measured during neutral breathing and in Valsalva maneuver and identified filter complications were recorded. A statistical analysis of these variables was then performed.ResultsDuring Valsalva maneuvers, a 60 % decrease of the IVC cross-sectional area and a fivefold increase in the IVC pressure were identified (p < 0.001). There was a statistically significant difference in the reduction of the cross-sectional area at the filter strut level (p < 0.001) in patient with filter penetration. Difficulty in filter retrieval was higher in penetrated or tilted filters (p < 0.001; p = 0.005). 3D computational models showed significant IVC deformation around the filter during Valsalva maneuver.ConclusionCaval morphology and hemodynamics are clearly affected by Valsalva maneuvers. A physiological reduction of IVC cross-sectional area is associated with higher risk of filter penetration, despite short dwell times. Physiologic data should be used to improve future filter designs to remain safely implanted over longer dwell times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Splenic Arterial Embolization in the Treatment of Severe Portal Hypertension Due to Pancreatic Diseases: The Primary Experience in 14 Patients

ObjectiveThis retrospective study reports our experience using splenic arterial particle embolization and coil embolization for the treatment of sinistral portal hypertension (SPH) in patients with and without gastric bleeding.MethodsFrom August 2009 to May 2012, 14 patients with SPH due to pancreatic disease were diagnosed and treated with splenic arterial embolization. Two different embolization strategies were applied; either combined distal splenic bed particle embolization and proximal splenic artery coil embolization in the same procedure for acute hemorrhage (1-step) or interval staged distal embolization and proximal embolization in the stable patient (2-step). The patients were clinically followed.ResultsIn 14 patients, splenic arterial embolization was successful. The one-step method was performed in three patients suffering from massive gastric bleeding, and the bleeding was relieved after embolization. The two-step method was used in 11 patients, who had chronic gastric variceal bleeding or gastric varices only. The gastric varices disappeared in the enhanced CT scan and the patients had no gastric bleeding during follow-up.ConclusionsSplenic arterial embolization, particularly the two-step method, proved feasible and effective for the treatment of SPH patients with gastric varices or gastric variceal bleeding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arterial Embolization in the Management of Mesenteric Bleeding Secondary to Blunt Abdominal Trauma

IntroductionMesenteric bleeding is a rare but potentially life-threatening complication of blunt abdominal trauma. It can induce active hemorrhage and a compressive hematoma leading to bowel ischemia. Emergency laparotomy remains the gold standard treatment. We aimed to study the effectiveness and complications of embolization in patients with post-traumatic mesenteric bleeding.Materials and MethodsThe medical records of 7 consecutive patients with active mesenteric bleeding treated by embolization in a level-one trauma center from 2007 to 2014 were retrospectively reviewed. All patients presented with active mesenteric bleeding on CT scans without major signs of intestinal ischemia. We focused on technical success, clinical success, and the complications of embolization.ResultsSix endovascular procedures were successful in controlling hemorrhage but 1 patient had surgery to stop associated arterial and venous bleeding. One patient suffered from bowel ischemia, a major complication of embolization, which was confirmed by surgery. No acute renal failure was noted after angiography. For 1 patient we performed combined management as the endovascular approach allowed an easier surgical exploration.ConclusionIn mesenteric trauma with active bleeding, embolization is a valuable alternative to surgery and should be considered, taking into account the risk of bowel ischemia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I/II Study of Radiofrequency Ablation for Malignant Renal Tumors: Japan Interventional Radiology in Oncology Study Group 0701

PurposeThis multicenter phase I/II study evaluated the safety, feasibility, and initial efficacy of radiofrequency ablation (RFA) for small malignant renal tumors.MethodsThirty-three patients were enrolled in the study. A single session of RFA was performed in patients with a renal tumor of 1–3 cm in greatest diameter, with the exception of lesions adjacent to the renal hilum. The primary endpoint was the safety of renal RFA, and the secondary endpoints were its feasibility and initial efficacy for local control, as well as the incidence and grade of adverse events. Clinical efficacy was evaluated by CT scans within 1 week and at a further 4 weeks after the procedure using the criteria adapted from the Response Evaluation Criteria in Solid Tumors.ResultsThe RFA procedure was completed in 100 % (95 % confidence interval [CI] 89–100 %) of all 33 patients. There were no severe adverse events (0 % [95 % CI 0–11 %]). Among the 33 patients, a complete response, partial response, progressive disease, and stable disease were seen in 28 (85 %), 0 (0 %), one (3 %), and one (3 %) patient(s), respectively, with a tumor response rate of 85 % [95 % CI 68–95 %]). Three patients (9 %), including one ineligible patient (3 %), were not evaluable. Out of 30 evaluable patients, a complete response was achieved in 28 (93 %).ConclusionThe current multicenter trial revealed that RFA is a safe, feasible, and effective treatment for small malignant renal tumors in patients who are not candidates for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Influence of Preoperative Aneurysmal Thrombus Quantity and Distribution on the Development of Type II Endoleaks with Aneurysm Sac Enlargement After EVAR of AAA

PurposeTo determine the influence of preoperative aneurysmal thrombus quantity and distribution on the development of type II endoleak with aneurysm sac enlargement after endovascular aneurysm repair (EVAR).Materials and MethodsWe retrospectively analyzed the pre- and postoperatively performed CT scans of 118 patients who had follow-up imaging for at least 1 year after EVAR available. We assessed preoperative thrombus perimeter (T{sub Peri}), diameter (T{sub Dia}), cross-sectional area (T{sub CSA}), and volume (T{sub Vol}). The preoperative thrombus distribution was classified into no thrombus, semilunar-shaped (anterior, right side, left side, posterior) thrombus, and circumferential type thrombus. The number of preoperative patent aortic side branches (ASB) was identified. Endpoint was type II endoleak with aneurysm volume (A{sub Vol}) increase of ≥5 % during follow-up.ResultsDuring follow-up (2 years, range 1–9 years), 17 patients with type II endoleak had significant A{sub Vol} increase. Less preoperative T{sub Peri}, T{sub Dia}, T{sub CSA}, and T{sub Vol} were associated with A{sub Vol} increase. A circumferential thrombus distribution significantly protected against aneurysm enlargement (p = 0.028). The variables with the strongest significance for A{sub Vol} increase were preoperative T{sub Vol}/A{sub Vol} ratio (OR 0.95; p = 0.037) and number of patent ASB (OR 3.52; p < 0.001).ConclusionA low preoperative T{sub Vol}/A{sub Vol} ratio and a high number of patent ASB were associated with aneurysm sac enlargement after EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Severe Gastrointestinal Haemorrhage: Summary of a National Quality of Care Study with Focus on Radiological Services

Purpose of StudyTo identify the remediable factors in the quality of care provided to patients with severe gastrointestinal (GI) bleeding.MethodAll hospital admissions in the first four months of 2013 with ICD10 coding for GI bleeding who received a transfusion of 4 units or more of blood. Up to five cases/hospital randomly selected for structured case note peer review. National availability of GI bleeding services data derived from organisational questionnaire completed by all hospitals.Results4563/29,796 (15.3%) of GI bleeds received 4 or more units of blood with a mortality rate of 20.2% compared to 7.3% without blood transfusion. 30.8% of GI bleeds received a blood transfusion. 32% (60/185) of hospitals admitting acute GI bleeds lacked 24/7 endoscopy. 26% (48/185) had on-site embolisation 24/7 with a further 34% (64/185) accessing embolisation by transfer within a validated formal network. Blood product use was inappropriate in 20% (84/426). Improved management, principally earlier senior gastroenterologist review and/or endoscopy, would have reduced blood product use in 25% (113/457). 14.5% (90/618) had a CT scan which identified the site of bleeding in 32% (29/90). 7.8% (36/459) underwent an Interventional Radiology (IR) procedure but a further 6.3% (21/33) should have had IR. 6% (36/586) underwent surgery with 21/36 for uncontrolled bleeding. In 20/35 IR was not considered despite the majority being suitable for IR. Overall 44% (210/476) received an acceptable standard of care according to peer review.Conclusions26 recommendations were made to improve the quality of care in GI bleeding, with six principle recommendations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chitosan–Sodium Tetradecyl Sulfate Hydrogel: Characterization and Preclinical Evaluation of a Novel Sclerosing Embolizing Agent for the Treatment of Endoleaks

PurposeTo compare the efficacy of an embolization agent with sclerosing properties (made of chitosan and sodium tetradecyl sulfate, CH–STS) with a similar embolization agent but without sclerosing properties (made of chitosan, CH) in treating endoleaks in a canine endovascular aneurysm repair model.MethodsTwo chitosan-based radiopaque hydrogels were prepared, one with STS and one without STS. Their rheological, injectability, and embolizing properties were assessed in vitro; afterwards, their efficacy in occluding endoleaks was compared in a canine bilateral aneurysm model reproducing type I endoleaks (n = 9 each). The primary endpoint was endoleak persistence at 3 or 6 months, assessed on a CT scan and macroscopic examination. Secondary endpoints were the occurrence of stent-graft (SG) thrombosis, the evolution of the aneurysm mean diameter, as well as aneurysm healing and inflammation scores in pathology examinations.ResultsIn vitro experiments showed that both products gelled rapidly and presented initial storage moduli greater than 800 Pa, which increased with time. Both gels were compatible with microcatheter injection and occlude flow up to physiological pressure in vitro. In a type I endoleak model, the injection of CH–STS sclerosing gel tended to reduce the risk of occurrence of endoleaks, compared to CH non-sclerosing agent (2/9 vs. 6/9, p = 0.069). No case of SG thrombosis was observed. Moderate inflammation was found around both gels, with a comparable intensity score in both CH and CH–STS groups (2.6 ± 0.9 and 2.7 ± 0.9, respectively; p = 0.789).ConclusionsFlow occlusion combined with chemical endothelial denudation appears promising for the treatment of endoleaks.Level of EvidenceN/A.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Median Arcuate Ligament Syndrome: A Single-Center Experience with 23 Patients

BackgroundMedian arcuate ligament syndrome (MALS) is a rare entity that occurs when the median arcuate ligament of the diaphragm is low-lying, causing a compression to the underlying celiac trunk. We reviewed the vascular changes associated with MALS in an effort to emphasize the seriousness of this disease and the complications that may result.MethodsThis is a retrospective descriptive analysis of 23 consecutive patients diagnosed with MALS between January 1, 2012 and December 31, 2015 at a tertiary medical center. Computed tomographic (CT) scans, medical records, and patient follow-up were reviewed.ResultsThe number of patients included herein was 23. The median age was 56 years (17–83). Sixteen patients (69.6%) had a significant arterial collateral circulation. Eleven patients (47.8%) were found to have visceral artery aneurysms; 4 patients (36.4%) bled secondary to aneurysm rupture. All ruptured aneurysms were treated with endovascular approach. The severity of the hemodynamic changes appears to be greater with complete occlusion,ConclusionsMALS causes pathological hemodynamic changes within the abdominal vasculature. Follow-up is advised for patients who develop a collateral circulation. Resulting aneurysms should preferably be treated when the size ratio approaches three. Treatment of these aneurysms can be done via an endovascular approach coupled with possible celiac artery decompression to restore physiologic blood flow.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Onyx Embolization for Occlusion of the Proximal Internal Iliac Artery During EVAR in Patients with Unsuitable Landing Zones in the Common Iliac Artery

Background: Twenty percent of the patients with AAA have an aneurysm involving the common iliac arteries. Large common iliac diameter can be treated with an iliac branched device or extension of the stent graft to the external iliac artery with occlusion of the ipsilateral internal iliac artery (IIA) to prevent type 2 endoleaks. This study describes and evaluates a embolization technique using Onyx in conjunction with EVAR in aneurysms with poor landing zones in the common iliac arteries. Methods: Patients with Onyx IIA embolization during EVAR, identified from the hospital operating code database, constitute the study population. Onyx embolization was performed by injection at the IIA origin. Peri- and postoperative complications were collected from the medical records. Thin-sliced CT scan was performed 1 month and 1 year after the procedure. Results: Thirty-six patients with complex iliac anatomy and insufficient landing zones (without sealing possibility for standard stent grafts) were identified out of 243 consecutive EVAR treatments during a 13-year period. In seventeen patients (7%), the IIA was embolized with Onyx. Technical success was obtained in all 17 patients, without adverse event or procedural complication. No complication related to the embolization procedure was noted during follow-up. Conclusions: During EVAR treatment of patients with aneurysm involving the common iliac artery, Onyx embolization of IIA is a feasible option without need of selective catheterization of the IIA orifice, potentially preserving important branches of the IIA and simplifying emergency procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Lung Contour with Closed Principal Curve and Machine Learning

Radiation therapy plays an essential role in the treatment of cancer. In radiation therapy, the ideal radiation doses are delivered to the observed tumor while not affecting neighboring normal tissues. In three-dimensional computed tomography (3D-CT) scans, the contours of tumors and organs-at-risk (OARs) are often manually delineated by radiologists. The task is complicated and time-consuming, and the manually delineated results will be variable from different radiologists. We propose a semi-supervised contour detection algorithm, which firstly uses a few points of region of interest (ROI) as an approximate initialization. Then the data sequences are achieved by the closed polygonal line (CPL) algorithm, where the data sequences consist of the ordered projection indexes and the corresponding initial points. Finally, the smooth lung contour can be obtained, when the data sequences are trained by the backpropagation neural network model (BNNM). We use the private clinical dataset and the public Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset to measure the accuracy of the presented method, respectively. To the private dataset, experimental results on the initial points which are as low as 15% of the manually delineated points show that the Dice coefficient reaches up to 0.95 and the global error is as low as 1.47 × 10{sup −2}. The performance of the proposed algorithm is also better than the cubic spline interpolation (CSI) algorithm. While on the public LIDC-IDRI dataset, our method achieves superior segmentation performance with average Dice of 0.83.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A deep learning framework for layer-wise porosity prediction in metal powder bed fusion using thermal signatures

Abstract Part quality manufactured by the laser powder bed fusion process is significantly affected by porosity. Existing works of process–property relationships for porosity prediction require many experiments or computationally expensive simulations without considering environmental variations. While efforts that adopt real-time monitoring sensors can only detect porosity after its occurrence rather than predicting it ahead of time. In this study, a novel porosity detection-prediction framework is proposed based on deep learning that predicts porosity in the next layer based on thermal signatures of the previous layers. The proposed framework is validated in terms of its ability to accurately predict lack of fusion porosity using computerized tomography (CT) scans, which achieves a F1-score of 0.75. The framework presented in this work can be effectively applied to quality control in additive manufacturing. As a function of the predicted porosity positions, laser process parameters in the next layer can be adjusted to avoid more part porosity in the future or the existing porosity could be filled. If the predicted part porosity is not acceptable regardless of laser parameters, the building process can be stopped to minimize the loss.

42 ENGINEERING↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Letter to the Editor: Use of Publicly Available Image Resources

Here we write with regard to the Academic Radiology article entitled, “Computer-aided Diagnosis for Lung Cancer: Usefulness of Nodule Heterogeneity” by Drs. Nishio and Nagashima (1). The authors also report on a computerized method to classify as benign or malignant lung nodules present in computed tomography (CT) scans.

60 APPLIED LIFE SCIENCES↗