Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Low-resolution gamma-ray spectrometry for an information barrier based on a multi-criteria template-matching approach

Gamma-ray spectrometry has been successfully employed to identify unique items containing special nuclear materials. Template information barriers have been developed in the past to confirm items as warheads by comparing their gamma signature to the signature of true warheads. Their development has, however, not been fully transparent, and they may not be sensitive to some relevant evasion scenarios. Here, we develop a fully open template information barrier concept, based on low-resolution measurements, which, by design, reduces the extent of revealed sensitive information. The concept is based on three signatures of an item to be compared to a recorded template. The similarity of the spectrum is assessed by a modification of the Kolmogorov–Smirnov test to confirm the isotopic composition. The total gamma count rate must agree with the template as a measure of the projected surface of the object. In order to detect the diversion of fissile material from the interior of an item, a polyethylene mask is placed in front of the detector. Neutrons from spontaneous and induced fission events in the item produce 2.223 MeV gamma rays from neutron capture by hydrogen-1 in the mask. This peak is detected and its intensity scales with the item's fissile mass. This analysis is based on MCNP Monte Carlo simulations of various plutonium configurations suggests that this concept can distinguish a valid item from a variety of invalid ones. The concept intentionally avoids any assumptions about specific spectral features, such as looking for specific gamma peaks of specific isotopes, thereby facilitating a fully unclassified discussion. Finally, by making all aspects public and allowing interested participants to contribute to the development and benchmarking, we enable a more open and inclusive discourse on this matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of neutron light output response functions in EJ-309 organic scintillators

An accurate model of the nonlinear detector response of organic scintillators to neutrons is required to correctly simulate fast neutron detection, as well as interpret measured pulse height data. Several empirical and semi-empirical models are available to fit measured scintillator light output data. In this work, EJ-309 light output data from neutrons depositing 1.15–5.15 MeV on hydrogen were analyzed using empirical models as well as semi-empirical models based on the work of Birks and Voltz. Although all tested models fit the experimental light output data well in the measured range, the models were observed to diverge in low-energy extrapolation. The models were then tested by comparing a measurement and MCNPX-PoliMi simulation of an EJ-309 detector response to fast neutrons from a 252 Cf spontaneous fission source. The agreement between the measured and simulated pulse height distributions varied significantly depending on the light output model used. The best agreement between simulated and measured neutron pulse height distributions was achieved by using the Birks model. The bin-by-bin agreement was better than 5% over the range 0.08–2.18 MeVee, and better than 10% from 2.18 to 3.13 MeVee. Furthermore, the integral count rate over the range 0.08–3.14 MeVee differed by less than 1% in absolute units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A low-background γγ-coincidence spectrometer for radioisotope studies

The performance of a new, low-background NaI(Tl) spectrometer, based on γγ-coincidence counting, is discussed. We present experimental coincidence efficiencies, timing resolutions, background count rates, and minimum detectable activities. The spectrometer has been simulated using Geant4, and the results are used for estimating coincidence efficiencies for volume sources. To test the device, we measured the cosmogenic 26 Al activity in a small (17.7 g) meteorite fragment. Here, we find a value of 52.9±7.8 dpm / kg, in agreement with the activity measured previously in a much larger fragment of the same meteorite using a HPGe detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing the Fork detector for quantitative spent nuclear fuel verification

The Fork detector is widely used by the safeguards inspectorate of the European Atomic Energy Community (EURATOM) and the International Atomic Energy Agency (IAEA) to verify spent nuclear fuel. Fork measurements are routinely performed for safeguards prior to dry storage cask loading. Additionally, spent fuel verification will be required at the facilities where encapsulation is performed for acceptance in the final repositories planned in Sweden and Finland. The use of the Fork detector as a quantitative instrument has not been prevalent due to the complexity of correlating the measured neutron and gamma ray signals with fuel inventories and operator declarations. A spent fuel data analysis module based on the ORIGEN burnup code was recently implemented to provide automated real-time analysis of Fork detector data. This module allows quantitative predictions of expected neutron count rates and gamma units as measured by the Fork detectors using safeguards declarations and available reactor operating data. This study describes field testing of the Fork data analysis module using data acquired from 339 assemblies measured during routine dry cask loading inspection campaigns in Europe. Assemblies include both uranium oxide and mixed-oxide fuel assemblies. More recent measurements of 50 spent fuel assemblies at the Swedish Central Interim Storage Facility for Spent Nuclear Fuel are also analyzed. An evaluation of uncertainties in the Fork measurement data is performed to quantify the ability of the data analysis module to verify operator declarations and to develop quantitative go/no-go criteria for safeguards verification measurements during cask loading or encapsulation operations. The goal of this approach is to provide safeguards inspectors with reliable real-time data analysis tools to rapidly identify discrepancies in operator declarations and to detect potential partial defects in spent fuel assemblies with improved reliability and minimal false positive alarms. Finally, the results are summarized, and sources and magnitudes of uncertainties are identified, and the impact of analysis uncertainties on the ability to confirm operator declarations is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a large-area iQID imager for safeguards applications

Environmental sampling and sample analyses by the International Atomic Energy Agency is a key method for verifying declarations in international safeguards agreements. Quantitative Digital Autoradiography for Environmental Samples is a system developed by Pacific Northwest National Laboratory to examine environmental swipe samples (ESS) prior to subsequent, destructive analysis. This approach is passive and noninvasive for imaging beta and gamma emissions, which transmit through the plastic bags containing the ESS. Alpha particle imaging is also possible with different ESS containers. This technology is based on a portable, real-time, event-counting, high spatial resolution system called iQID (ionizing-radiation Quantum Imaging Detector), which is made from commercial, off-the-shelf components. This includes a scintillator in direct contact with a micro-channel plate image intensifier and a lens for imaging the intensified scintillation events onto a CCD/CMOS camera. The QDARES large-area iQID includes a fiber-optic taper coupled to the image intensifier which increases the imaging area to a ~100 cm square with a 105 mm x 105 mm taper. In this study, we describe new characterization results, including spatial resolution, energy response, minimum detectable activity for several isotopes, detector uniformity, and count-rate capability.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Localization of a radioactive source in an urban environment using Bayesian Metropolis methods [Bayesian Metropolis methods for source localization in an urban environment]

Here, we present a method for localizing an unknown source of radiation in an urban environment using a distributed detector network. This method employs statistical parameter estimation techniques, relying on an approximation for the response of a detector to the source based on a simplified model of the underlying transport phenomena, combined with a Metropolis-type sampler that is modified to propagate the effect of fixed epistemic uncertainties in the material macroscopic cross sections of objects in the scene. We apply this technique to data collected during a measurement campaign conducted in a realistic analog for an urban scene using a network of six mobile detectors. Our initial results are able to localize the source to within approximately 8 m over a scene of size 300 m 200 m in two independent trials with 30 min count times, including a characterization of the uncertainty associated with the poorly known macroscopic cross sections of objects in the scene. In these measurements, the nearest detectors were between 20 m to 30 m from the source, and recorded count rates between approximately 3 and 13 times background. A few detectors had line-of-sight to the source, while the majority were obscured by objects present in the scene. After extending our model to account for the orientation of the detectors and correcting for anomalies in the measurement data we were able to further improve the localization accuracy to approximately 2 m in both trials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification and validation of atmospheric transport models with the UF Training Reactor

The University of Florida Training Reactor (UFTR) is a 100-kW ARGONAUT type reactor with a unique design such that a large volume of air passes through the core, producing and releasing significant quantities of 41 Ar. Once released, the radioargon is dispersed throughout the atmosphere and decays by a 1294 keV gamma ray emission. This quantified, validated, and controlled 41 Ar plume can be utilized to verify and validate atmospheric transport models (ATMs). This is accomplished by coupling an ATM with MCNP and comparing the results to experimental measurements. For this study, an in-house developed Gaussian dispersion model and the EPA approved Gaussian model AERMOD were coupled with MCNP to simulate the results of a six hour measurement taken on May 8th, 2018. For the measurements and simulations, a grid of seven NaI detectors were placed in four different rooftop locations near the UFTR plume stack. With easterly winds dominating during the morning and early afternoon, both the measurement results and simulations displayed a higher 41 Ar photon count rate on the detectors west of the plume stack throughout the day. Overall, the AERMOD simulations produced better results when compared to the in-house model, particularly for the detectors placed east and west of the plume stack. While some of the AERMOD data showed a strong correlation with the measurements, the results remain inconsistent. Here, due to the varying accuracy of the simulation results, it is theorized that the relationship between measurement results and simulations will improve with the use of localized weather information or the utilization of non-Gaussian dispersion models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision characterization of the neutron light output of stilbene along the directions of maximum and minimum response

The scintillation light output response of stilbene crystals has been calculated for protons recoiling along the a, b, and c' crystalline axes with energies between 1.3 and 10 MeV using neutrons produced with the tandem Van de Graaff accelerator at Triangle Universities Nuclear Laboratory. The proton recoil energy and direction were measured using the coincident detection of neutrons between a stilbene scintillator and an array of EJ-309 liquid scintillators spanning arranged neutron recoil angles. The maximum light output was discovered to coincide with proton recoils along the a-axis, in disagreement with other published measurements, which reported the b-axis as the direction of the maximum light output. Additional measurements were conducted using two different stilbene crystals to confirm these results: a second measurement using the coincident detection of neutrons; measurements of neutron full energy deposition events along the a and b axes; and measurements of the count rate for 252 Cf neutrons traveling along the a and b axes directions. All measurements found that recoils along the a-axis produce the maximum light output.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sensitivity of the simulation of passive neutron emission from UF 6 cylinders to the uncertainties in both 19 F(α,n) energy spectrum and thick target yield of 234 U in UF 6

Interest in safeguards verification measurements using passive thermal neutron counting to assay 235 U content in large 30B UF 6 canisters has grown in recent years. Here, the prohibitively high cost and impracticality of using reference 30B calibration cylinders extensively will likely make accurate simulations of increasing interest. Accuracy of the simulated response will define the confidence in the predicted response and the extent to which simulations can reasonably be relied upon. With 234 U driven 19 F(α, n) reactions being the main neutron source in low enriched UF 6 the uncertainties of the 19 F(α, n) energy spectrum and the thick target yield of 234 U in UF 6 propagate into the uncertainty in the predicted response and represent a major influence of basic nuclear data. Here sensitivity of the simulated total (Singles) and coincidence (Doubles) count rates are assessed for the Passive Neutron Enrichment Meter using six potential 19 F(α, n) neutron energy spectra over a range of enrichments and material distributions. The results indicate that variations in the Singles and Doubles due to simulated (α, n) neutron spectrum are less than 1.5% for this set of simulated neutron spectra, with dependence varying inversely with enrichment. Singles uncertainty is only slightly less than that of the thick target 19 F(α, n) yield corresponding to the primary neutron source, whereas the 19 F(α, n) yield dependence of the Doubles is reduced by the non-negligible 238 U(SF) coincident neutron emissions. Based on available thick target 19 F(α, n) yield estimates the uncertainty is on the order of 5%, establishing this as the main nuclear data limitation when simulating thermal neutron detectors response for 30B UF 6 storage cylinders. Based on these findings, it appears that the measurement and evaluation of the thick target 19 F(α, n) yield for uranium hexafluoride is due.

19F(α,n) neutron spectrum↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density scaling approximation for Monte-Carlo simulations of radioactive plumes

The release of radioactive gas into the atmosphere can diffuse into large volumes of air downwind from the point of release. The extent of radioactivity can cover thousands of cubic meters of air. For such large volumes, the weather models used to predict the down-wind distribution of the plume and the radiation transport models used to predict the radiation reaching ground-level from the plume can take tens of hours of computer time on multi-node institutional High-Performance Computing facilities. In this paper we focus on the radiation transport aspect of plume modeling. Here, we describe a phenomenological method for approximating the amounts of radiation that reach ground level from large volumes of a static radioactive plume that can be calculated on a stand-alone personal computer in much shorter computation times than those usually needed for such large volume evaluations. We refer to this method as the Density Scaling Approximation (DSA). Its ability to approximate ground-level count rates of large plumes comes from using a small-plume volume with a scaled-up value of air density to simulate the same number of scatterings that occur during transport in larger plume volumes at normal air density. We demonstrate the DSA by using a 100 m-diameter air-filled hemispherical dome geometry with a uniform volumetric activity of 135 Xe gas throughout the air-filled volume. The DSA for a larger dome diameter is obtained by evaluating the 100 m dome with an air density scaled up by the linear ratio of the larger diameter to the 100 m diameter. We find that this approximation works well for dome diameters up to 1200 m – the largest diameter studied and a size more than sufficient for accounting for all the radiation from 135 Xe. Moreover, most of our DSA results can be calculated over 500 times faster than corresponding full-sized geometry with normal air density. To help evaluate the accuracy of the DSA and gain insight into how well it can reproduce different regions of the spectra, we use three, easily understood regions of interest to compare the DSA results to the full-sized geometry at normal air density results. These regions are the full-energy peak, the region of single-Compton scattering, and the region of multiple-Compton scattering. We show how the dominance of the Compton scattering mechanism determines this division and thus provides insight into how Compton scattering is manifested in spectra from photon scattering through air in general, and how well the DSA approximation works.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating the β-Ga 2 O 3 Schottky diodes for alpha radiation detection

Schottky barrier diodes were fabricated on (001) monoclinic β-Ga 2 O 3 wafers with low doped epitaxial layers of 7.0 × 10 15 cm −3 . Circular Ni Schottky contacts with area 2 mm 2 were deposited by electron beam evaporation. Devices were characterized electrically by performing forward and reverse current-voltage sweeps with a range of −100 V–2 V, as well as capacitance-voltage sweeps to −30 V. The breakdown voltage was also determined to be −180 V for the devices. Experiments measuring the electrical response from incident X-ray radiation was performed. A response time to X-ray radiation of less than 1 s was recorded and a decay time of approximately 2 s after removing X-ray source, which primarily attribute to X-ray switching on and off time. Energy spectra of alpha particles from a 0.9 μCi 241 Am button source was collected at various voltage biases using devices with the lowest measured leakage current while reverse biased. The total count rate was observed to increase linearly with increasing device bias. In conclusion, the peak channel number was observed to increase with increasing bias with the best resolution of 9.5% at −100 V reverse bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗