Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSIVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Corrosion Testing of Brazed Space Station IATCS Materials

Increased nickel concentrations in the IATCS coolant prompted a study of the corrosion rates of nickel-brazed heat exchangers in the system. The testing has shown that corrosion is occurring in a silicon-rich intermetallic phase in the braze filler of coldplates and heat exchangers as the result of a decrease in the coolant pH brought about by cabin carbon dioxide permeation through polymeric flexhoses. Similar corrosion is occurring in the EMU de-ionized water loop. Certain heat exchangers and coldplates have more silicon-rich phase because of their manufacturing method, and those units produce more nickel corrosion product. Silver biocide additions did not induce pitting corrosion at silver precipitate sites.

Pohlman, Matthew J.↗

Corrosion-Prevention Capabilities of a Water-Borne, Silicone-Based, Primerless Coating

Comparative tests have been performed to evaluate the corrosion-prevention capabilities of an experimental paint of the type described in Water-Borne, Silicone-Based, Primerless Paints, NASA Tech Briefs, Vol. 26, No. 11 (November 2002), page 30. To recapitulate: these paints contain relatively small amounts of volatile organic solvents and were developed as substitutes for traditional anticorrosion paints that contain large amounts of such solvents. An additional desirable feature of these paints is that they can be applied without need for prior application of primers to ensure adhesion. The test specimens included panels of cold-rolled steel, stainless steel 316, and aluminum 2024-T3. Some panels of each of these alloys were left bare and some were coated with the experimental water-borne, silicone-based, primerless paint. In addition, some panels of aluminum 2024-T3 and some panels of a fourth alloy (stainless steel 304) were coated with a commercial solvent-borne paint containing aluminum and zinc flakes in a nitrile rubber matrix. In the tests, the specimens were immersed in an aerated 3.5-weight-percent aqueous solution of NaCl for 168 hours. At intervals of 24 hours, the specimens were characterized by electrochemical impedance spectroscopy (EIS) and measurements of corrosion potentials. The specimens were also observed visually. As indicated by photographs of specimens taken after the 168-hour immersion (see figure), the experimental primerless silicone paint was effective in preventing corrosion of stainless steel 316, but failed to protect aluminum 2024-T3 and cold-rolled steel. The degree of failure was greater in the case of the cold-rolled steel. On the basis of visual observations, EIS, and corrosion- potential measurements, it was concluded that the commercial aluminum and zinc-filled nitrile rubber coating affords superior corrosion protection to aluminum 2024-T3 and is somewhat less effective in protecting stainless steel 304.

Calle, Luz Marina↗

Accelerated Test Method for Corrosion Protective Coatings Project

This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

Technology Portfolio System↗

Tank 241-AY-102 Secondary Liner Corrosion Evaluation - 14191

In October 2012, Washington River Protection Solutions, LLC (WRPS) determined that the primary tank of 241-AY-102 (AY-102) was leaking. A number of evaluations were performed after discovery of the leak which identified corrosion from storage of waste at the high waste temperatures as one of the major contributing factors in the failure of the tank. The propensity for corrosion of the waste on the annulus floor will be investigated to determine if it is corrosive and must be promptly removed or if it is benign and may remain in the annulus. The chemical composition of waste, the temperature and the character of the steel are important factors in assessing the propensity for corrosion. Unfortunately, the temperatures of the wastes in contact with the secondary steel liner are not known; they are estimated to range from 45 deg C to 60 deg C. It is also notable that most corrosion tests have been carried out with un-welded, stress-relieved steels, but the secondary liner in tank AY-102 was not stress-relieved. In addition, the cold weather fabrication and welding led to many problems, which required repeated softening of the metal to flatten secondary bottom during its construction. This flame treatment may have altered the microstructure of the steel.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion and Chemical Characterization of Bio-Oils from Biomass with Varying Ash and Moisture Contents

As part of the Feedstock Conversion Interface Consortium four samples of pine chips (all combinations of low and high moisture and ash content) were collected and processed for fast pyrolysis. The prepared biomass samples were liquefied at the National Renewable Energy Laboratory (NREL) using the fast pyrolysis process. Following some characterization of the bio-oils at NREL, the bio-oils were shipped to Oak Ridge National Laboratory (ORNL) for corrosion testing and further characterization.The content and composition of ash in each bio-oil was determined. Corrosion testing consisted of exposing selected metallic and elastomer samples for 1000 hr at 50°C and for longer times at room temperature as well as electrochemical impedance spectroscopy measurements to assess relative corrosivity of the bio-oils. Chemical characterization was conducted to identify the corrosive component of the bio-oils as well as to define the chemical differences among the oils. It was hypothesized that there could be a catalytic effect from the higher ash content in two of the biomass sources. Results of these characterization and corrosion studies will be reported.

Keiser, Jim↗

Mechanical Properties and Corrosion Behavior of As-Cast Mg-Zn-Zr-(La) Magnesium Alloys

The effects of La content on the mechanical properties and corrosion behavior of as-cast Mg-Zn-Zr (ZK) magnesium alloys were investigated. The results showed that La addition to ZK60 alloy resulted in a considerable grain refinement and an increase in the volume fraction of second phases by formation of Mg-Zn-La ternary phase. The tensile tests were performed at both room and elevated temperatures. At room temperature, the yield and tensile strengths and elongation-to-fracture significantly increased with 0.2 wt.% La addition, then deteriorated slightly with increasing La additions above 0.2 wt.%. At 200 °C, the yield and tensile strengths continually improved and elongation-to-fracture decreased with increasing La content due to the presence of thermally stable Mg-Zn-La phase. Immersion and electrochemical corrosion tests revealed that the formation of Mg-Zn-La phases led to a higher amount of cathodic sites and preferential corrosion propagation, and thus a decrease in the corrosion resistance of ZK60 alloys.

36 MATERIALS SCIENCE↗

Ca Addition Effects on the Microstructure, Tensile and Corrosion Properties of Mg Matrix Alloy Containing 8 wt.% Mg{sub 2}Si

The microstructure, tensile properties and corrosion behavior of the Mg-8 wt.% Mg{sub 2}Si-x%Ca alloy have been studied by the use of optical microscopy, scanning electron microscopy equipped with energy-dispersive spectroscopy, x-ray diffraction, standard tensile testing, polarization test and electrochemical impedance spectroscopy (EIS) measurements. Microstructural studies indicated that Ca modifies both primary and eutectic Mg{sub 2}Si phase. It was found that the average size of primary Mg{sub 2}Si particles is about 60 μm, which is dropped by about 82% in the alloy containing 0.05 wt.% Ca. By the addition of different Ca contents, Ca-rich intermetallics (i.e., CaSi{sub 2} and CaMgSi) were formed. The modification mechanism of adding Ca during solidification was found to be due to the strong effect of CaMgSi phase as a heterogonous nucleation site, apart from CaSi{sub 2} which was reported before, for Mg{sub 2}Si intermetallics. Tensile testing results ascertained that Ca addition enhances both ultimate tensile strength (UTS) and elongation values. The optimum amount of Ca was found to be 0.1 wt.%, which improved UTS and elongation values from about 130 MPa and 2% to 165 MPa and 5.5%, whereas more Ca addition (i.e., 3 wt.%) reduced the tensile properties of the alloy to about 105 MPa and 1.8%, which can be due to the formation of CaMgSi intermetallics with deteriorating needle-like morphology. Polarization and EIS tests also showed that the Mg-3%Si-0.5%Ca alloy pronounces as the best anti-corrosion alloy. Nevertheless, further added Ca (up to 3 wt.%) deteriorated the corrosion resistance due to predominance of worse galvanic coupling effect stemmed from the presence of stronger CaMgSi cathode in comparison with Mg{sub 2}Si. With higher Ca additions, an adverse effect was seen on corrosion resistance of the Mg-3%Si alloy, as a result of forming a weak film on the alloy specimen surface.

36 MATERIALS SCIENCE↗

Thermal Treatment, Sliding Wear and Saline Corrosion of Al In Situ Reinforced with Mg{sub 2}Si and Ex Situ Reinforced with TiC Particles

The main objective of this work is to produce a composite consisting of (a) a cast heat-treatable Al-Mg-Si alloy with high contents of Mg for corrosion resistance and Si to offset the Mg-due poor castability (in situ hypoeutectic Mg{sub 2}Si/Al composite) and (b) TiC particles at high enough volume fractions (≤ 15%), in order to achieve a satisfactory combination of wear and corrosion performance. TiCp/Al-7Mg-5Si (wt.%) composites were produced by flux-assisted casting followed by solution and aging heat treatment. Solution treatment led to a relatively uniform dispersion and shape rounding of Mg{sub 2}Si precipitates and Si particles. TiC particle addition resulted in refinement of primary Al, modification of the Mg{sub 2}Si Chinese script morphology and refinement/spheroidization of primary Mg{sub 2}Si. Heat treatment combined with TiC addition notably improved the sliding wear resistance of Al-7Mg-5Si. A wear mechanism has been proposed. The TiC/Al interfaces remained intact of corrosion during potentiodynamic polarization of the heat-treated materials in 3.5 wt.% NaCl. Different main forms of localized corrosion in 3.5 wt.% NaCl were identified for each TiC content (0, 5, 15 vol.%), depending on specific degradation favoring microstructural features (topology/size/interface wetting) at each composition.

36 MATERIALS SCIENCE↗

Effect of Low-Temperature Sensitization on the Corrosion Behavior of AISI Type 304L SS Weld Metal in Simulated Groundwater

The manuscript presents the investigations carried out on the effect of low-temperature sensitization (LTS) of 304L SS weld metal on its corrosion behavior in simulated groundwater, for its application as a canister material for long-term storage of nuclear vitrified high-level waste in geological repositories. AISI type 304L SS weld pad was fabricated by multipass gas tungsten arc welding process using 308L SS filler wire. The as-welded specimens were subsequently subjected to carbide nucleation and further to LTS at 500 °C for 11 days to simulate a temperature of 300 °C for 100-year life of the canister in geological repositories. Delta ferrite (δ-ferrite) content of the 304L SS weld metal substantially decreased on carbide nucleation treatment and further only a marginal decrease occurred on LTS treatment. The microstructure of the as-welded consisted of δ-ferrite as a minor phase distributed in austenite matrix. The δ-ferrite appeared fragmented in the carbide-nucleated and LTS-treated weld metal. The degree of sensitization measured by double-loop electrochemical potentokinetic reactivation method indicated an increase in carbide nucleation treatment when compared to the as-welded specimens, and further increase occurred on LTS treatment. Potentiodynamic anodic polarization investigations in simulated groundwater indicated a substantial decrease in the localized corrosion resistance of the carbide-nucleated and LTS 304L SS weld metals, when compared to the as-welded specimens. Post-experimental micrographs indicated pitting as the primary mode of attack in the as-welded, while pitting and intergranular corrosion (IGC) occurred in the carbide-nucleated weld metal. LTS-treated weld metal predominantly underwent IGC attack. The decrease in the localized corrosion resistance of the weld metal after LTS treatment was found to have a direct correlation with the degree of sensitization and the weld microstructure. The results are detailed in the manuscript.

36 MATERIALS SCIENCE↗

Effect of the Heat Treatment on the Corrosion Resistance of Duplex Stainless Steels

Duplex stainless steels (DSS) are biphasic austenitic-ferritic steels in which the best combination of mechanical and corrosion resistance properties is achieved for an almost equal volume fraction of the phases. In this work, the effect of secondary phases precipitation on the corrosion resistance of four DSS grades (2101, 2304, 2205 and 2507), after isothermal aging in the critical temperature range 750-900 °C, was studied. The corrosion resistance was investigated by potentiodynamic polarization tests in both 0.6 M NaCl solution (pH 7) and in an acid chlorinated solution (pH 3) at room temperature. Moreover, the critical pitting temperature was determined according to ASTM G150. The results showed that secondary phases precipitation mainly influenced the resistance to corrosion of the lean duplex grades.

36 MATERIALS SCIENCE↗

Effect of Different Zirconium Contents on the Corrosion Resistance of ZrO{sub 2}-TiO{sub 2} Film-Coated Stainless Steel

This work discusses the corrosion resistance of x%zirconia (ZrO{sub 2})–x%titania (TiO{sub 2}) nanocomposite films with different percentages of ZrO{sub 2} prepared on stainless steel by dipping the substrates in sol–gel solutions. The phase compositions and microstructures of the films were investigated by x-ray diffraction (XRD) and scanning electron microscopy (SEM). Tafel polarization curves and electrochemical impedance spectroscopy (EIS) were employed to investigate the corrosion resistance of the coated steel substrates during immersion in a 5% NaCl solution at room temperature. The results showed that when the percentage of ZrO{sub 2} in the sol–gel was relatively low, the film contained cracks, leading to a poor corrosion resistance. When the percentage of ZrO{sub 2} was higher, the corrosion resistance of the film was also affected by the sintering temperature; a sintering temperature of 650 °C gave the best protection of the metal surface, and the protection efficiency was 95%.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Grain Boundary and Crystallographic Orientation on the Stress Corrosion Behavior of an Al-Zn-Mg Alloy

The effect of grain boundary and crystallographic orientation on the stress corrosion behavior of an Al-4.5Zn-1.4Mg alloy was investigated by comparing the performance of constant load stress corrosion test (CLSCT) and tensile test of specimens parallel to the longitudinal and transverse directions of the extruded plate. The results revealed that the strength of the longitudinal and transverse specimens decreased by 9.68 and 18.13%, respectively, after 10-day CLSCT. The transverse specimens show poor resistance to stress corrosion cracking (SCC). The grain boundaries (GB) of the longitudinal section are less dense, and more of them are distributed along the extrusion direction compared with the cross section with selected areas of the same size. The SCC of all specimens starts from the side faces of the specimen, and it is dominated by intergranular cracking. But the corrosion of the transverse specimens was more serious. The cracks of all specimens tend to propagate along the GBs with misorientation of about 50°-60°, and the difference of Schmidt factor (SF) values of grains on both sides of the crack is significantly large. The crack of longitudinal specimens propagates relatively parallel to the tensile direction, while propagation of the crack in transverse specimens is more zigzag.

36 MATERIALS SCIENCE↗

Aqueous Corrosion Behavior of Cast CoCrFeMnNi Alloy

CoCrFeMnNi high-entropy alloy demonstrates good mechanical properties and can be further strengthened by thermomechanical processes. A sample alloy prepared by vacuum casting in a graphite mold was further investigated for its corrosion resistance. One-millimeter thin strips of cast alloy were used to investigate its corrosion behavior at room temperature. Linear potentiodynamic tests of the alloy in sodium chloride solution confirmed uniform corrosion property comparable to stainless steel AISI 304. However, a positive cyclic hysteresis loop indicated susceptibility to pitting corrosion. In sodium hydroxide solution, metastable pit formation was observed, while sulfuric acid solution passivated the alloy. In both cases, the alloy did not show any spontaneous pitting tendency.

36 MATERIALS SCIENCE↗

The study of stress application and corrosion cracking on Ni-16 Cr-9 Fe (Alloy 600) C-ring samples by polychromatic X-ray microdiffraction

Microscopic strains associated with stress corrosion cracks have been investigated in stressed C-rings of Ni-16 Cr-9 Fe (Alloy 600) boiler tubing. Polychromatic X-ray microdiffraction was used to measure deviatoric strain tensors and the distribution of dislocations near cracks that had been propagated in electrochemically accelerated corrosion tests. An associated investigation of the C-ring-induced strains prior to corrosion showed significant tensile strain in the stress axis direction by the torsional closure of the alloy tube section in the C-ring test. Significant grain lattice rotation and pronounced plastic strain at some grain boundaries were noted. Stress-corrosion-cracking-generated intergranular cracks were produced in two Alloy 600 specimens after 6 h and 18 h tests. The diffraction patterns and resultant strain tensors were mapped around the cracked area to a 1 μm spatial resolution. The strain tensor transverse to the crack growth direction showed tensile strain at the intergranular region just ahead of the crack tip for both specimens. Both cracks were found to follow grain boundary pathways that had the lowest angle of misorientation. Dislocation distributions within each grain were qualitatively obtained from the shapes of the diffraction spots and the effect of 'hard' and 'soft' grains on the crack pathway was explored for both 6 h and 18 h specimens. The Schmid factor of one of the grains adjacent to the crack at the 6 h and 18 h initiation sites was found to be the lowest, compared to Schmid factors calculated for surface grains away from the initiation site, and also along the crack path into the bulk.

36 MATERIALS SCIENCE↗

Understanding a novel form of intergranular corrosion of stainless steel 316L exposed to molten LiCl-Li 2 O-Li

We report stainless steel 316 L exposed to LiCl-Li2O molten salt containing Li metal for 500 and 1000 h experiences deep intergranular attack and bulk void formation. This degradation is due to a synergistic corrosion mechanism, different than other forms of molten salt corrosion, where Cr and Mn oxides and carbides form along grain boundaries and are dissolved by Li metal. Synchrotron transmission X-ray microscopy 3D imaging is used to show corrosion morphology and Cr enrichment and depletion in a novel format that has not previously been used for bulk corrosion samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrochemical stability and corrosion behavior of Ni-Cr alloy in molten LiCl-KCl salt

This study investigated the electrochemical properties and potential-dependent stability of Cr(II) and Ni(II) in a eutectic LiCl-KCl molten salt at 500 °C under an argon atmosphere using a three-electrode cell configuration with a glassy carbon working electrode, Ag/Ag + reference electrode, and graphite counter electrode. Cyclic voltammetry was employed to characterize the Cr(0)/Cr(II)/Cr(III) and Ni(0)/Ni(II) redox transitions, yielding diffusion coefficients of 0.50 (±0.01) × 10 −5 cm 2 s −1 for Cr(II) and 0.91 (±0.16) × 10 −5 cm 2 s −1 for Ni(II) at 500 °C. The redox stability domains of these species provided insight into the corrosion mechanisms of a Ni-Cr alloy (80–20 wt %) in LiCl-KCl salt. The measured open circuit potential of the alloy corresponded to the range of potentials where the Ni(0) and Cr(II) species are stable, indicating a preferential dissolution of Cr. Immersion testing of the alloy for 336 h confirmed significant Cr depletion (or Ni-enrichment) at the surface layer, corroborating Cr dealloying as the dominant corrosion reaction under open circuit conditions. Additionally, the application of a small anodic overpotential (0.11 V) resulted in selective Cr dissolution while a large anodic overpotential (0.25 V) resulted in co-dissolution of both Cr and Ni. Furthermore, these results demonstrate that the corrosion mechanisms of a Ni-Cr alloy in LiCl-KCl depend upon the applied potential, and thus the redox conditions of the molten salt should be carefully controlled in the design of a redox buffer to mitigate corrosion in molten salt environments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Corrosion of 316 SS in direct contact with Zircaloy-4 in repository relevant conditions

The effects of interfacial contact between 316 stainless steel (316 SS) waste canister and spent fuel cladding material (Zircaloy-4) in case of water intrusion into a deep geological repository are investigated. Hydrothermal corrosion experiments of 316 SS and Zircaloy-4 in direct contact were performed at elevated temperatures in MilliQ water and simulated Mont Terri groundwater. Hematite, magnetite, chromite, and baddeleyite form as secondary phases. pH of the Mont Terri solution increases with corrosion duration and magnetite forms preferentially instead of hematite. Thermodynamic modeling shows that iron oxidation in 316 SS controls the pH and redox potential of the aqueous environment and is in good agreement with experimental Mont Terri results, showing that experimental Mont Terri results trend to equilibrium. All oxides except hematite are predicted to exist at thermodynamic equilibrium based on calculations, implying that experimentally formed hematite will be reduced or transformed to magnetite at equilibrium. The thermodynamically predicted chromite was observed to form only at the interface where 316 SS was in contact with Zircaloy-4 at 250°C, showing that contact with Zircaloy-4 seems to accelerate the 316 SS corrosion to thermodynamic equilibrium. Finally, Mont Terri groundwater readily trends towards thermodynamic equilibrium, leading to a pH and redox buffered system that is dominated by iron in solution coming from the accelerated corrosion of 316 SS caused by Zircaloy-4 contact.

316 stainless steel↗

Friction stir welded AM50 and AZ31 Mg alloys: Microstructural evolution and improved corrosion resistance

One of the major drawbacks of Mg alloys is poor weldability, caused by porosity formation during conventional fusion welding processes. Friction Stir Welding (FSW) is promising technique in this context since it is a solid state technique. Contradicting results were published in the literature regarding the FSWed Mg alloys joint's properties. Current research was performed in order to investigate the microstructure and corrosion properties of FSWed Mg alloys, studying representatives of two commercial families: wrought AZ31-H24 and die cast AM50. It was found that in both alloys recrystallization occurred during the FSW. In AM50 the mechanism of the recrystallization was continuous, manifested by dislocation rearrangement into sub grain boundaries. In AZ31 discontinuous recrystallization had occurred through grain boundaries migration - twins rotated with respect to the matrix, turning into low angle grain boundaries. Corrosion resistance has improved during the FSW in both alloys to different extents. In the AM50 alloy, the nugget exhibited significantly higher surface potential than the base metal mainly due to the higher Al concentration in the matrix of the nugget, resulting from the dissolution of Al-enrichment and β-Mg{sub 17}Al{sub 12} phase. In the AZ31 alloy, no change in Al concentration had occurred, and the surface potential measured in the nugget was only slightly higher than in the base metal. These results underline the appropriateness of the FSW for Mg alloys since during the conventional welding deterioration of the corrosion resistance occurs. - Highlights: • Following FSW, AZ31-H24 experienced discontinuous recrystallization. • In AZ31 grain boundaries migration occurred, thus twins rotated. • In die cast AM50 continuous recrystallization occurred during the FSW. • In AM50 - dislocations rearranged into sub grain boundaries. • Corrosion resistance has improved during the FSW in both alloys to different extent.

36 MATERIALS SCIENCE↗