Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CASE METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Application of State Quantization-Based Methods in HEP Particle Transport Simulation

Simulation of particle-matter interactions in complex geometries is one of the main tasks in high energy physics (HEP) research. An essential aspect of it is an accurate and efficient particle transportation in a non-uniform magnetic field, which includes the handling of volume crossings within a predefined 3D geometry. Quantized State Systems (QSS) is a family of numerical methods that provides attractive features for particle transportation processes, such as dense output (sequences of polynomial segments changing only according to accuracy-driven discrete events) and lightweight detection and handling of volume crossings (based on simple root-finding of polynomial functions). In this work we present a proof-of-concept performance comparison between a QSS-based standalone numerical solver and an application based on the Geant4 simulation toolkit, with its default Runge-Kutta based adaptive step method. In a case study with a charged particle circulating in a vacuum (with interactions with matter turned off), in a uniform magnetic field, and crossing up to 200 volume boundaries twice per turn, simulation results showed speedups of up to 6 times in favor of QSS while it being 10 times slower in the case with zero volume boundaries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sub-Rayleigh quantum imaging using single-photon sources

We propose a technique capable of imaging a distinct physical object with sub-Rayleigh resolution in an ordinary far-field imaging setup using single-photon sources and linear optical tools only. We exemplify our method for the case of a rectangular aperture and two or four single-photon emitters obtaining a resolution enhanced by a factor of 2 or 4, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Squeezed K{sup +}K{sup -} correlations in high energy heavy ion collisions

The hot and dense medium formed in high energy heavy ion collisions may modify some hadronic properties. In particular, if hadron masses are shifted in-medium, it was demonstrated that this could lead to back-to-back squeezed correlations (BBC) of particle-antiparticle pairs. Although well-established theoretically, the squeezed correlations have not yet been discovered experimentally. A method has been suggested for the empirical search of this effect, which was previously illustrated for {phi}{phi} pairs. We apply here the formalism and the suggested method to the case of K{sup +}K{sup -} pairs, since they may be easier to identify experimentally. The time distribution of the emission process plays a crucial role in the survival of the BBC's. We analyze the cases where the emission is supposed to occur suddenly or via a Lorentzian distribution, and compare with the case of a Levy distribution in time. Effects of squeezing on the correlation function of identical particles are also analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Linear point and sound horizon as purely geometric standard rulers

The baryon acoustic oscillations feature (BAO) imprinted in the clustering correlation function is known to furnish us cosmic distance determinations that are independent of the cosmological-background model and the primordial perturbation parameters. These measurements can be accomplished rigorously by means of the purely geometric BAO methods. To date two different purely geometric BAO approaches have been proposed. The first exploits the linear-point standard ruler. The second, called correlation-function model-fitting, exploits the sound-horizon standard ruler. A key difference between them is that, when estimated from clustering data, the linear point makes use of a cosmological-model-independent procedure to extract the ratio of the ruler to the cosmic distance, while the correlation-function model-fitting relies on a phenomenological cosmological model for the correlation function. Nevertheless the two rulers need to be precisely defined independently of any specific observable (e.g., the BAO). We define the linear point and sound horizon and we fully characterize and compare the two rulers’ cosmological-parameter dependence. We find that they are both geometrical (i.e., independent of the primordial cosmological parameters) within the required accuracy, and that they have the same parameter dependence for a wide range of parameter values. We estimate the rulers’ best-fit values and errors, given the cosmological constraints obtained by the Planck Satellite team from their measurements of the cosmic microwave background temperature and polarization anisotropies. We do this for three different cosmological models encompassed by the purely geometric BAO methods. In each case we find that the relative errors of the two rulers coincide and they are insensitive to the assumed cosmological model. Interestingly both the linear point and the sound horizon shift by 0.5σ when we do not fix the spatial geometry to be flat in Λ CDM. Finally, this points toward a sensitivity of the rulers to different cosmological models when they are estimated from the cosmic microwave background.

79 ASTRONOMY AND ASTROPHYSICS↗

Critical line from imaginary to real baryonic chemical potentials in two-color QCD

The method of analytic continuation from imaginary to real chemical potentials {mu} is one of the few available techniques to study QCD at finite temperature and baryon density. One of its most appealing applications is the determination of the critical line for small {mu}: we perform a direct test of the validity of the method in this case by studying two-color QCD, where the sign problem is absent. The (pseudo)critical line is found to be analytic around {mu}{sup 2}=0, but a very large precision would be needed at imaginary {mu} to correctly predict the location of the critical line at real {mu}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrability of the symmetry reduced bosonic dynamics and soliton generating transformations in the low energy heterotic string effective theory

Integrable structure of the symmetry reduced dynamics of massless bosonic sector of the heterotic string effective action is presented. For string background equations that govern in the space-time of D dimensions (D{>=}4), the dynamics of interacting gravitational, dilaton, antisymmetric tensor and any number n{>=}0 of Abelian vector gauge fields, all depending only on two coordinates, we construct an equivalent (2d+n)x(2d+n)-matrix spectral problem (d=D-2). This spectral problem provides the base for the development of various solution constructing procedures (dressing transformations, integral equation methods). For the case of the absence of Abelian gauge fields, we present the soliton generating transformations of any background with interacting gravitational, dilaton, and the second rank antisymmetric tensor fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the effect of Ga and In substitutions in the Ca 11 Bi 10 and Yb 11 Bi 10 bismuthides crystallizing in the tetragonal Ho 11 Ge 10 structure type

The Ga- and In-substituted bismuthides Ca 11 Ga x Bi 10– x , Ca 11 In x Bi 10– x , Yb 11 Ga x Bi 10– x , and Yb 11 In x Bi 10– x ( x < 2) can be readily synthesized employing molten Ga or In metals as fluxes. They crystallize in the tetragonal space group I 4/ mmm and adopt the Ho 11 Ge 10 structure type (Pearson code tI 84; Wyckoff sequence n 2 m j h 2 e 2 d ). The structural response to the substitution of Bi with smaller and electron-poorer In or Ga has been studied by single-crystal X-ray diffraction methods for the case of Ca 11 In x Bi 10– x [ x = 1.73 (2); octabismuth undecacalcium diindium]. The refinements show that the In atoms substitute Bi only at the 8 h site. The refined interatomic distances show an unconventional – for this structure type – bond-length distribution within the anionic sublattice. The latter can be viewed as consisting of isolated Bi 3- anions and [In 4 Bi 8 20- ] clusters for the idealized Ca 11 In 2 Bi 8 model. Formal electron counting and first-principle calculations show that the peculiar bonding in this compound drives the system toward an electron-precise state, thereby stabilizing the observed bond-length pattern.

Chemistry↗

Intracavitary in vivo dosimetry based on multichannel fiber-coupled radioluminescence and optically stimulated luminescence of Al{sub 2}O{sub 3}:C

Fiber Optic Dosimetric Catheters (FODCs) composed of chains of alumina crystals are investigated by the CEA LIST within the French ANR-INTRADOSE Project in the purpose of intracavitary in vivo dosimetry (IVD) during Brachytherapy (BT) with iridium sources and Intensity-Modulated Radiation Therapy (IMRT) with linear accelerators. A dedicated process involving PMMA fibers, cast altogether forming hexagonal bundle, is demonstrated. Optically Stimulated Luminescence (OSL) signals are recorded on-line after irradiation and absorbed doses are compared to planned dose distribution. Real-time dose measurements may also be performed by recording the Radioluminescence (RL), spontaneously emitted by the crystals during irradiation. In this case, a correction method is implemented to correct for stem effect influence (Cerenkov and scintillation generated within the fibers). For BT, the dual-fiber subtraction method is used (using a reference fiber) whereas the time discrimination method is used for IMRT. The experimental dose distribution leads to an underestimation of the source-sensor distance presumably due to energy dependence of the alumina crystal at low photon energy. At the time being, Monte-Carlo modeling of the FODC is performed with the aim to estimate this energy dependence and finally correct for it. Finally, metrological and preclinical validations are still running at Centre Leon Berard (Lyon (France)) in the purpose of checking the compliance of the FODC prototypes with treatment specifications and medical constraints. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Let Each Quantum Bit Choose Its Basis Gates

Near-term quantum computers are primarily limited by errors in quantum operations (or gates) between two quantum bits (or qubits). A physical machine typically provides a set of basis gates that include primitive 2-qubit (2Q) and 1-qubit (1Q) gates that can be implemented in a given technology. 2Q entangling gates, coupled with some 1Q gates, allow for universal quantum computation. In superconducting technologies, the current state of the art is to implement the same 2Q gate between every pair of qubits (typically an XX-or XY-type gate). This strict hardware uniformity requirement for 2Q gates in a large quantum computer has made scaling up a time and resource-intensive endeavor in the lab. We propose a radical idea – allow the 2Q basis gate(s) to differ between every pair of qubits, selecting the best entangling gates that can be calibrated between given pairs of qubits. This work aims to give quantum scientists the ability to run meaningful algorithms with qubit systems that are not perfectly uniform. Scientists will also be able to use a much broader variety of novel 2Q gates for quantum computing. We develop a theoretical framework for identifying good 2Q basis gates on “nonstandard” Cartan trajectories that deviate from “standard” trajectories like XX. We then introduce practical methods for calibration and compilation with nonstandard 2Q gates, and discuss possible ways to improve the compilation. To demonstrate our methods in a case study, we simulated both standard XY-type trajectories and faster, nonstandard trajectories using an entangling gate architecture with far-detuned transmon qubits. We identify efficient 2Q basis gates on these nonstandard trajectories and use them to compile a number of standard benchmark circuits such as QFT and QAOA. Furthermore, our results demonstrate an 8x improvement over the baseline 2Q gates with respect to speed and coherence-limited gate fidelity.

quantum computing↗

Muon Tracing and Image Reconstruction Algorithms for Cosmic Ray Muon Computed Tomography

Cosmic ray muon-computed tomography (μCT) is a new imaging modality with unique characteristics that could be particularly important for diverse applications including nuclear nonproliferation, spent nuclear fuel monitoring, cargo scanning, and volcano imaging. The strong scattering dependence of muons on atomic number Z in combination with high penetration range could offer a significant advantage over existing techniques when dense, shielded containers must be imaged. However, μCT reconstruction using conventional filtered back-projection is limited due to the overly simple assumptions that do not consider the curved path caused by multiple Coulomb scattering prompting the need for more sophisticated approaches to be developed. Here, we argue that the use of improved muon tracing and scattering angle projection algorithms as well as an algebraic reconstruction technique should produce muon tomographic images with improved quality–or require fewer muons to produce the same image quality–compared to the case where conventional methods are used. We report on the development and assessment of three novel muon tracing methods and two scattering angle projection methods for μCT. Simulated dry storage casks with single and partial missing fuel assemblies were used as numerical examples to assess and compare the proposed methods. The reconstructed images showed an expected improvement in image quality when compared with conventional techniques, even without muon momentum information, which should lead to improved detection capability, even for partial defects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real Time Data Analysis With the ATLAS Trigger at the LHC in Run-2

The trigger selection capabilities of the ATLAS detector have been significantly enhanced for the LHC Run- 2 in order to cope with the higher event rates and with the large number of simultaneous interactions (pile-up) per protonproton bunch crossing. A new hardware system, designed to analyse real time event-topologies at Level-1 came to full use in 2017. A hardware-based track reconstruction system, expected to be used real-time in 2018, is designed to provide track information to the high-level software trigger at its full input rate. The high-level trigger selections are largely relying on offline-like reconstruction techniques, and in some cases multivariate analysis methods. Despite the sudden change in LHC operations during the second half of 2017, which caused an increase in pile-up and therefore also in CPU usage of the trigger algorithms, the set of triggers (so called trigger menu) running online has undergone only minor modifications thanks to the robustness and redundancy of the trigger system, and the use of a levelling luminosity scheme in agreement with LHC and other experiments. Here, this presentation gives a brief yet comprehensive review of the real-time performance of the ATLAS trigger system in 2017. Considerations will be presented on the most relevant parameters of the trigger (efficiency to collect signal and output data rate) as well as details on some aspects of the algorithms which are run real-time on the High Level Trigger CPU farm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Framework for Robust Long-Term Voltage Stability of Distribution Systems

Power injection uncertainties in distribution power grids, which are mostly induced by aggressive introduction of intermittent renewable sources, may drive the system away from normal operating regimes and potentially lead to the loss of long-term voltage stability (LTVS). Naturally, there is an ever increasing need for a tool for assessing the LTVS of a distribution system. This paper presents a fast and reliable tool for constructing inner approximations of LTVS regions in multidimensional injection space such that every point in our constructed region is guaranteed to be solvable. Numerical simulations demonstrate that our approach outperforms all existing inner approximation methods in most cases. Furthermore, the constructed regions are shown to cover substantial fractions of the true voltage stability region. In conclusion, the paper will later discuss a number of important applications of the proposed technique, including fast screening for viable injection changes, constructing an effective solvability index and rigorously certified loadability limits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the impact of dose rate variation upon RapidArc implementation of volumetric modulated arc therapy

Purpose: A study was carried out to evaluate the robustness and mutual interplay of two variables concurring to generate modulation patterns of the RapidArc (RapidArc) implementation of volumetric modulated arc therapy. Dose rate (DR) and gantry speed (GS) are free parameters optimized alongside field aperture shape by the RapidArc engine; however, they are limited by machine constraints and mutually compensate in order to deliver the proper MU/deg during the gantry rotation. Methods: Four test cases (one geometrical and three clinical) were selected and RapidArc plans were optimized using maximum allowed dose rates from 100 to 600 MU/min. The maximum gantry speed was fixed at 4.8 deg/s. Qualitative analysis of DR and GS patterns from these cases was summarized together with quantitative assessment of delivery parameters. Pretreatment quality assurance measurements and scoring of plan quality aimed to determine whether preferable initial conditions might be identified or the optimization engine might be invariant to those variables and capable of providing adequate plans independently from the limits applied. Results: The results of the study were: (i) High dynamic range in MU/deg is achievable across all dose rates by means of gantry speed modulation; (ii) there is a robust compensation mechanism between the two variables; (iii) from a machine delivery point-of-view, slightly improved accuracy is achieved when lower DRs are applied; however, this does not have practical consequences since measurements and plan evaluation showed a lack of clinically relevant deviation; and (iv) reduced total treatment time is a major advantage of high DR. Conclusions: A trend toward improved plan quality for clinical cases was observed with high DR but cannot be generalized, due to the limited amount of cases investigated and the consequent limited significance of the observed differences. As a minimum benefit, the reduced total treatment time should be considered as well.

60 APPLIED LIFE SCIENCES↗

FBP and BPF reconstruction methods for circular X-ray tomography with off-center detector

Purpose: Circular scanning with an off-center planar detector is an acquisition scheme that allows to save detector area while keeping a large field of view (FOV). Several filtered back-projection (FBP) algorithms have been proposed earlier. The purpose of this work is to present two newly developed back-projection filtration (BPF) variants and evaluate the image quality of these methods compared to the existing state-of-the-art FBP methods. Methods: The first new BPF algorithm applies redundancy weighting of overlapping opposite projections before differentiation in a single projection. The second one uses the Katsevich-type differentiation involving two neighboring projections followed by redundancy weighting and back-projection. An averaging scheme is presented to mitigate streak artifacts inherent to circular BPF algorithms along the Hilbert filter lines in the off-center transaxial slices of the reconstructions. The image quality is assessed visually on reconstructed slices of simulated and clinical data. Quantitative evaluation studies are performed with the Forbild head phantom by calculating root-mean-squared-deviations (RMSDs) to the voxelized phantom for different detector overlap settings and by investigating the noise resolution trade-off with a wire phantom in the full detector and off-center scenario. Results: The noise-resolution behavior of all off-center reconstruction methods corresponds to their full detector performance with the best resolution for the FDK based methods with the given imaging geometry. With respect to RMSD and visual inspection, the proposed BPF with Katsevich-type differentiation outperforms all other methods for the smallest chosen detector overlap of about 15 mm. The best FBP method is the algorithm that is also based on the Katsevich-type differentiation and subsequent redundancy weighting. For wider overlap of about 40-50 mm, these two algorithms produce similar results outperforming the other three methods. The clinical case with a detector overlap of about 17 mm confirms these results. Conclusions: The BPF-type reconstructions with Katsevich differentiation are widely independent of the size of the detector overlap and give the best results with respect to RMSD and visual inspection for minimal detector overlap. The increased homogeneity will improve correct assessment of lesions in the entire field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A hybrid electron and photon IMRT planning technique that lowers normal tissue integral patient dose using standard hardware

Purpose: To present a mixed electron and photon IMRT planning technique using electron beams with an energy range of 6-22 MeV and standard hardware that minimizes integral dose to patients for targets as deep as 7.5 cm. Methods: Ten brain cases, two lung, a thyroid, an abdominal, and a parotid case were planned using two planning techniques: a photon-only IMRT (IMRT) versus a mixed modality treatment (E + IMRT) that includes an enface electron beam and a photon IMRT portion that ensures a uniform target coverage. The electron beam is delivered using a regular cutout placed in an electron cone. The electron energy was chosen to provide a good trade-off between minimizing integral dose and generating a uniform, deliverable plan. The authors choose electron energies that cover the deepest part of PTV with the 65%-70% isodose line. The normal tissue integral dose, the dose for ring structures around the PTV, and the volumes of the 75%, 50%, and 25% isosurfaces were used to compare the dose distributions generated by the two planning techniques. Results: The normal tissue integral dose was lowered by about 20% by the E + IMRT plans compared to the photon-only IMRT ones for most studied cases. With the exception of lungs, the dose reduction associated to the E + IMRT plans was more pronounced further away from the target. The average dose ratio delivered to the 0-2 cm and the 2-4 cm ring structures for brain patients for the two planning techniques were 89.6% and 70.8%, respectively. The enhanced dose sparing away from the target for the brain patients can also be observed in the ratio of the 75%, 50%, and 25% isodose line volumes for the two techniques, which decreases from 85.5% to 72.6% and further to 65.1%, respectively. For lungs, the lateral electron beams used in the E + IMRT plans were perpendicular to the mostly anterior/posterior photon beams, generating much more conformal plans. Conclusions: The authors proved that even using the existing electron delivery hardware, a mixed electron/photon planning technique (E + IMRT) can decrease the normal tissue integral dose compared to a photon-only IMRT plan. Different planning approaches can be enabled by the use of an electron beam directed toward organs at risk distal to the target, which are still spared due the rapid dose fall-off of the electron beam. Examples of such cases are the lateral electron beams in the thoracic region that do not irradiate the heart and contralateral lung, electron beams pointed toward kidneys in the abdominal region, or beams treating brain lesions pointed toward the brainstem or optical apparatus. For brain, electron vertex beams can also be used without irradiating the whole body. Since radiation retreatments become more and more common, minimizing the normal tissue integral dose and the dose delivered to tissues surrounding the target, as enabled by E + IMRT type techniques, should receive more attention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical tomotherapy with dynamic running-start-stop delivery compared to conventional tomotherapy delivery

Purpose: Despite superior target dose uniformity, helical tomotherapy{sup ®} (HT) may involve a trade-off between longitudinal dose conformity and beam-on time (BOT), due to the limitation of only three available jaw sizes with the conventional HT (1.0, 2.5, and 5.0 cm). The recently introduced dynamic running-start-stop (RSS) delivery allows smaller jaw opening at the superior and inferior ends of the target when a sharp penumbra is needed. This study compared the dosimetric performance of RSS delivery with the fixed jaw HT delivery. Methods: Twenty patient cases were selected and deidentified prior to treatment planning, including 16 common clinical cases (brain, head and neck (HN), lung, and prostate) and four special cases of whole brain with hippocampus avoidance (WBHA) that require a high degree of dose modulation. HT plans were generated for common clinical cases using the fixed 2.5 cm jaw width (HT2.5) and WBHA cases using 1.0 cm (HT1.0). The jaw widths for RSS were preset with a larger size (RSS5.0 vs HT2.5 and RSS2.5 vs HT1.0). Both delivery techniques were planned based on identical contours, prescriptions, and planning objectives. Dose indices for targets and critical organs were compared using dose-volume histograms, BOT, and monitor units. Results: The average BOT was reduced from 4.8 min with HT2.5 to 2.5 min with RSS5.0. Target dose homogeneity with RSS5.0 was shown comparable to HT2.5 for common clinical sites. Superior normal tissue sparing was observed in RSS5.0 for optic nerves and optic chiasm in brain and HN cases. RSS5.0 demonstrated improved dose sparing for cord and esophagus in lung cases, as well as penile bulb in prostate cases. The mean body dose was comparable for both techniques. For the WBHA cases, the target homogeneity was significantly degraded in RSS2.5 without distinct dose sparing for hippocampus, compared to HT1.0. Conclusions: Compared to the fixed jaw HT delivery, RSS combined with a larger jaw width provides faster treatment delivery and improved cranial-caudal target dose conformity. The target coverage achieved by RSS with a large jaw width is comparable to the fixed jaw HT delivery for common cancer sites, but may deteriorate for cases where complex geometry is present in the middle part of the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-568: Improving Normal Brain Sparing with Increasing Number of Arc Beams for Volume Modulated Arc Beam Radiosurgery of Multiple Brain Metastases

Purpose: Intensity modulated arc beams have been newly reported for treating multiple brain metastases. The purpose of this study was to determine the variations in the normal brain doses with increasing number of arc beams for multiple brain metastases treatments via the TrueBeam Rapidarc system (Varian Oncology, Palo Alto, CA). Methods: A patient case with 12 metastatic brain lesions previously treated on the Leksell Gamma Knife Perfexion (GK) was used for the study. All lesions and organs at risk were contoured by a senior radiation oncologist and treatment plans for a subset of 3, 6, 9 and all 12 targets were developed for the TrueBeam Rapidarc system via 3 to 7 intensity modulated arc-beams with each target covered by at least 99% of the prescribed dose of 20 Gy. The peripheral normal brain isodose volumes as well as the total beam-on time were analyzed with increasing number of arc beams for these targets. Results: All intensisty modulated arc-beam plans produced efficient treatment delivery with the beam-on time averaging 0.6–1.5 min per lesion at an output of 1200 MU/min. With increasing number of arc beams, the peripheral normal brain isodose volumes such as the 12-Gy isodose line enclosed normal brain tissue volumes were on average decreased by 6%, 11%, 18%, and 28% for the 3-, 6-, 9-, 12-target treatment plans respectively. The lowest normal brain isodose volumes were consistently found for the 7-arc treatment plans for all the cases. Conclusion: With nearly identical beam-on times, the peripheral normal brain dose was notably decreased when the total number of intensity modulated arc beams was increased when treating multiple brain metastases. Dr Sahgal and Dr Ma are currently serving on the board of international society of stereotactic radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-09: Is It Sufficient to Use Only Low Density Tissue-Margin to Compensate Inter-Fractionation Setup Uncertainties in Lung Treatment?

Purpose: In lung radiation treatment, PTV is formed with a margin around GTV (or CTV/ITV). Although GTV is most likely of water equivalent density, the PTV margin may be formed with the surrounding low-density tissues, which may lead to unreal dosimetric plan. This study is to evaluate whether the concern of dose calculation inside the PTV with only low density margin could be justified in lung treatment. Methods: Three SBRT cases were analyzed. The PTV from the original plan (Plan-O) was created with a 5–10 mm margin outside the ITV to incorporate setup errors and all mobility from 10 respiratory phases. Test plans were generated with the GTV shifted to the PTV edge to simulate the extreme situations with maximum setup uncertainties. Two representative positions as the very posterior-superior (Plan-PS) and anterior-inferior (Plan-AI) edge were considered. The virtual GTV was assigned a density of 1.0 g.cm−3 and surrounding lung, including the PTV margin, was defined as 0.25 g.cm−3. Also, additional plan with a 1mm tissue-margin instead of full lung-margin was created to evaluate whether a composite-margin (Plan-Comp) has a better approximation for dose calculation. All plans were generated on the average CT using Analytical Anisotropic Algorithm with heterogeneity correction on and all planning parameters/monitor unites remained unchanged. DVH analyses were performed for comparisons. Results: Despite the non-static dose distribution, the high-dose region synchronized with tumor positions. This might due to scatter conditions as greater doses were absorbed in the solid-tumor than in the surrounding low-density lungtissue. However, it still showed missing target coverage in general. Certain level of composite-margin might give better approximation for the dosecalculation. Conclusion: Our exploratory results suggest that with the lungmargin only, the planning dose of PTV might overestimate the coverage of the target during treatment. The significance of this overestimation might warrant further investigation.

60 APPLIED LIFE SCIENCES↗