SEARCH · Engineering Papers
Results for “Build System”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Building Confidence in Complex Systems Models for Reducing Population Health Risks.
Abstract not provided.
Building Battery Energy Storage System Performance Data into an Economic Assessment
Economic assessments of battery energy storage systems (BESSs) rely on optimal dispatch methods to capture temporal interdependency of BESS operations and coupling among different grid applications. Many existing BESS economic assessment studies are based on a simplified first-order scalar model using BESS nameplate numbers. Such a method cannot accurately capture varying capabilities and nonlinear dynamics of a BESS, leading to inaccurate assessment results. This paper presents a practical implementation of performance data into the economic assessment of the BESSs recently developed within the Snohomish Public Utility District system in Washington State. Extensive testing conducted over multiple seasons is used to assess the technical performance and develop high-fidelity models of the BESSs. A dynamic programming algorithm is proposed to optimally dispatch the BESSs and assess the potential benefits from stacked value streams. The proposed method can be adapted for the economic assessment of other BESSs with different applications.
Intelligently Manufactured Homes with Factory Integrated Solar Systems Delivered to the Build Site Enabling Dramatic Soft Cost Reductions (Final Report)
Explore the source record for details and available documents.
Preliminary Build Guide for the Geophysical Monitoring Systems Common Source Code. 2019 Release
The purpose of this document to provide an advance copy of a "Build Guide" for a Generic Runnable System (GRS) of the Geophysical Monitoring Systems' (GMS) common source code. This guide includes a list of software dependencies and licenses, hardware specifications, and related instructions for how to build the system from the source code. The document is written for individuals who are experienced as administrators of Linux systems. The intention is to support preparation activities prior to the open source release so that dependencies may be in place to build and run the system. This document will be updated and provided with the open source release on GitHub, accompanied by a "Run Guide" for the system. An additional "Configuration Guide" will also be provided after the open source release so that users may explore system configuration options.
Synthesis Report on the Implementation of Building Energy Codes in China
China is the new leader in the global construction market, with $1,000 billion invested into new construction projects in 2010. With its already significant building stock, high construction rate of new buildings, and strong governmental commitment to improving building energy efficiency, China is positioned to have great influence on global building energy use in the years to come. Building energy efficiency was first addressed in the mid 1980s, after China developed its new political doctrine of “Socialism with Chinese Characteristics” in the late 1970s and launched its unprecedented economic reform. Since then, the development of building energy efficiency policy has gone through into five stages: (1) early research and preparation, (2) pilots and demonstrations, (3) institution development and goal setting, (4) goal implementation, and (5) development and implementation of an array of policies and projects promoting building energy efficiency (Chapter 2). Building energy standards and codes are one important policy instrument targeted by Chinese government. Over three decades of governmental efforts, China has successfully established a comprehensive system of building energy standards and codes. The system covers the life cycle process of a building project, from design, construction and acceptance, inspection, evaluation, modification, products and selection of building materials to building operation. This project, the DOS project, is focused on the implementation of four building energy codes: three of which are design standards (two for residential buildings and one for public/commercial) and one is a code of construction and acceptance (Chapter 3). The current implementation status of building energy codes in China is a tale of two extremes: while there is no implementation in rural areas, the implementation in urban areas is very encouraging. The compliance rates of building energy codes in both the design and construction stages in the inspected large- and mid-size cities were a stunning 98% and 90%, respectively, in 2009. The impressive compliance rates come from establishing an implementation system that consists of a complete loop of the monitoring and inspection subsystem: building design companies, building inspection companies, construction companies, construction inspection companies, testing companies and labs (all of them are third parties), and semi-governmental quality supervision stations to oversee the implementation process (Sections 4.1 and 4.2). Besides the unique, active engagement of third parties, China’s implementation practices are also equipped with strict penalties for violations (Section 4.3), annual inspection for building energy efficiency (Section 4.4), and comprehensive national title exams for key stakeholders (Section 4.5.1). So, what are the challenges faced by key stakeholders when they implement building energy codes? Through stakeholder meetings, focus group meetings, training seminars, onsite construction visits, and personal communications, the project team concluded that training and information dissemination is the ignored, under-invested, and weak component in China’s current implementation practices (Section 6.1).
Editorial for Special Issue: Grid-Interactive Efficient Buildings—Part 2
This issue of the ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC) is fully dedicated to peer-reviewed papers specific to technologies and applications of Grid-interactive Efficient Buildings (GEBs). As defined by a series of publications by the U.S. Department of Energy (DOE) and outlined in Part 1 of the editorial of JESBC August 2020 issue, GEBs are efficient, connected, smart, and flexible buildings. This GEB special issue covers some technologies and applications for grid-connected buildings and communities. Some of technologies included in the special issue are dynamic insulation systems for building envelopes, building integrated fuel cells, and rooftop PV systems. Furthermore, the issue outlines the designs and cost-benefits of net-zero energy (NZE) buildings and carbon neutral communities in the United States.
Performance Simulation and Analysis of Occupancy-Based Control for Office Buildings with Variable-Air-Volume Systems
Variable-air-volume (VAV) systems are used in many office buildings. The minimum airflow rate setting of VAV terminal boxes has a significant impact on both energy consumption and indoor air quality. Conventional controls usually have the terminal’s minimum airflow rate at a constant (e.g., 30% or more of the terminal design airflow rate), irrespective of the occupancy status, which may cause problems, such as excessive simultaneous heating and cooling, under ventilation, and thermal comfort issues. This paper examines the potential of energy savings from occupancy-based controls (OBCs). The sensed occupancy information, either occupant presence or people count, is used to determine the airflow rate of terminal boxes, the thermostat setpoints, and the lighting control. Using EnergyPlus, a whole-building energy modeling software, the energy savings of OBC strategies are evaluated for representative existing medium office buildings in the U.S. The simulation results show that the conventional OBC, based on occupant presence sensing, can save 8% of whole-building energy use in Miami (hot climate) for systems without air-side economizer and about 13% in both Baltimore (mixed climate) and Chicago (cold climate). Comparatively, the advanced OBC, based on people counting, can save 8% in Miami to 23% in Baltimore for systems with economizers. The outdoor-air fraction of the supply air from air-handling units significantly affects the potential energy savings from the advanced OBC strategy. In addition to energy savings, the advanced OBC satisfies the zone ventilation during all occupied hours over the whole year.
Cybersecurity and Optimization in Smart “Autonomous” Buildings
Significant resources have been invested in making buildings “smart” by digitizing, networking and automating key systems and operations. Smart autonomous buildings create new energy efficiency, economic and environmental opportunities. But as buildings become increasingly networked to the Internet, they can also become more vulnerable to various cyber threats. Automated and Internet-connected buildings systems, equipment, controls, and sensors can significantly increase cyber and physical vulnerabilities that threaten the confidentiality, integrity, and availability of critical systems in organizations. Securing smart autonomous buildings presents a national security and economic challenge to the nation. Ignoring this challenge threatens business continuity and the availability of critical infrastructures that are enabled by smart buildings. In this chapter, the authors address challenges and explore new opportunities in securing smart buildings that are enhanced by machine learning, cognitive sensing, artificial intelligence (AI) and smart-energy technologies. The chapter begins by identifying cyber-threats and challenges to smart autonomous buildings. Then it provides recommendations on how AI enabled solutions can help smart buildings and facilities better protect, detect and respond to cyber-physical threats and vulnerabilities. Next, the chapter will provide case studies that examine how combining AI with innovative smart-energy technologies can increase both cybersecurity and energy efficiency savings in buildings. The chapter will conclude by proposing recommendations for future cybersecurity and energy optimization research for examining AI enabled smart-energy technology.
Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings
Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.
Quantification of Load Flexibility in Residential Buildings Using Home Energy Management Systems
With increasing penetration of renewable energy resources, the flexibility of operating behind-the-meter (BTM) resources plays a key role in enhancing grid reliability and resilience. Residential buildings with home energy management systems (HEMS) can provide desired flexibility for the distribution system operator (DSO) while considering customer comfort and preferences. This paper discusses a methodology to quantify the flexibility of BTM resources of residential buildings using HEMS. First, we propose a model predictive control framework to formulate the flexibility band comprising nominal, upper, and lower demand profiles. Second, the paper proposes a dispatch method for HEMS to compute the control signals for each BTM resource (e.g., air conditioner, water heater, home battery system) upon receiving a flexibility service request from the DSO. The case study provides insight into the flexibility provided at the whole-home level with different user preferences and seasons. The results demonstrate that HEMS is capable of providing flexibility service at the request of the DSO while delivering primary services to the building occupants.
Model predictive control for active insulation in building envelopes
Active insulation systems (AISs) refer to building envelopes with insulation materials that can change their thermal conductivity and are coupled with thermal mass to reduce building energy consumption and peak power. In this research, a novel optimal control approach is proposed to evaluate the maximum theoretical energy and cost-saving potential of AISs. A time-varying model predictive control (TV-MPC) controller was used to optimally select the AIS mode and simultaneously determine the operation of the heating, ventilation and air conditioning (HVAC) system so that the maximum saving potential of the entire system can be realized. To comprehensively evaluate the power shifting flexibility of AISs, two optimization objectives—minimizing weekly electric energy consumption and minimizing weekly electricity cost—were considered. The summer season simulation results show that under the first objective, more than 50% electric and thermal energy was saved when the upper boundary of the indoor air temperature was set to 25 °C. Furthermore under the second optimization objective, 38% of the cost was saved. It can be expected that the developed approach can be easily applied to multiple types of AISs with different mechanisms.
Stochastic Modeling of Overtime Occupancy and Its Application in Building Energy Simulation and Calibration
Overtime is a common phenomenon around the world. Overtime drives both internal heat gains from occupants, lighting and plug-loads, and HVAC operation during overtime periods. Overtime leads to longer occupancy hours and extended operation of building services systems beyond normal working hours, thus overtime impacts total building energy use. Current literature lacks methods to model overtime occupancy because overtime is stochastic in nature and varies by individual occupants and by time. To address this gap in the literature, this study aims to develop a new stochastic model based on the statistical analysis of measured overtime occupancy data from an office building. A binomial distribution is used to represent the total number of occupants working overtime, while an exponential distribution is used to represent the duration of overtime periods. The overtime model is used to generate overtime occupancy schedules as an input to the energy model of a second office building. The measured and simulated cooling energy use during the overtime period is compared in order to validate the overtime model. A hybrid approach to energy model calibration is proposed and tested, which combines ASHRAE Guideline 14 for the calibration of the energy model during normal working hours, and a proposed KS test for the calibration of the energy model during overtime. The developed stochastic overtime model and the hybrid calibration approach can be used in building energy simulations to improve the accuracy of results, and better understand the characteristics of overtime in office buildings.
Equation-based languages – A new paradigm for building energy modeling, simulation and optimization
Most of the state-of-the-art building simulation programs implement models in imperative programming languages. This complicates modeling and excludes the use of certain efficient methods for simulation and optimization. In contrast, equation-based modeling languages declare relations among variables, thereby allowing the use of computer algebra to enable much simpler schematic modeling and to generate efficient code for simulation and optimization. We contrast the two approaches in this paper. We explain how such manipulations support new use cases. In the first of two examples, we couple models of the electrical grid, multiple buildings, HVAC systems and controllers to test a controller that adjusts building room temperatures and PV inverter reactive power to maintain power quality. In the second example, we contrast the computing time for solving an optimal control problem for a room-level model predictive controller with and without symbolic manipulations. As a result, exploiting the equation-based language led to 2, 200 times faster solution
Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes
This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance (Rutkowski, H. Manual D -- Residential Duct Systems, 3rd edition, Version 1.00. Arlington, VA: Air Conditioning Contractors of America, 2009.). IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations (Beach, R., Prahl, D., and Lange, R. CFD Analysis of Flexible Duct Junction Box Design. Golden, CO: National Renewable Energy Laboratory, submitted for publication 2013). These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.
Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes
This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance. IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations. These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.
Building Datasets and Training Methods for ML Based Magnet Quench Detection
Detecting quenches in superconducting (SC) magnets during training is a challenging process that involves capturing physical events that occur at different frequencies and appear as various signal features. These events may be correlated across instrumentation type, thermal cycle, and ramp. These events together build a more complete picture of continuous processes occurring in the magnet, and may allow us to flag potential precursors for quench detection. We present our work on building an automatic machine learning (ML) based quench detection system. We build upon our existing work on unsupervised auto-encoders for acoustic sensors and quench antenna (QA) by first establishing a supervised ML training pipeline. We show the results of an event tagging, analysis, and simulation framework on our QA and acoustic data which are used concurrently to build a training dataset for a supervised implementation. We then show how this supervised training can be used as a prior in a semi-supervised framework and compare this to the unsupervised neural network auto-encoder performance.This allows us to have a more concrete understanding of the performance of our algorithms relative to physical events occurring in the magnet, and also provides a baseline software tool to generically evaluate our quench prediction autoencoders under completely unsupervised, supervised, and semi-supervised training conditions.
Building America Case Study: Trade-Friendly Retrofit Insulated Panels for Existing Buildings, Albany, New York
This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of building air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.