Software for Improved Extraction of Data From Tape Storage

A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are still used at Stennis Space Center but have been discontinued by the manufacturer. Whereas the original software could be activated by a command-line interface only, the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

Cheng, Chiu-Fu↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn s magnetosphere, and a steady flux of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager1 . The ubiquitous, surface- hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 Km altitude (approximately 1hPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 141Dalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

The Gas Chromatograph Mass Spectrometer for the Huygens Probe

Titan is unique in the solar system, the only moon that has a dense atmosphere. The major constituents of the atmosphere, nitrogen and methane, are continuously broken apart by a combination of solar UV, impinging electrons from Saturn's magnetosphere, and a steady flow of cosmic rays. The resulting molecular fragments recombine and form a variety of new species, many of which were detected for the first time by Voyager 1. The ubiquitous, surface-hiding aerosol blanket manifests the existence of still more complex compounds. In addition to hydrocarbons and nitriles, the atmosphere is known to contain CO, CO2 and externally delivered H2O. The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of the atmosphere of Titan from 170 km altitude (approximately lhPa) to the surface (approximately 1500hPa) and determine the isotope ratios of the major constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to obtain compositional information of several surface materials. The GCMS consists of a quadrupole mass spectrometer (QP) with a secondary electron multiplier ion detector, a three-column gas chromatograph (GC) and an elaborate gas sampling system. The gas sampling system will provide atmospheric samples to the QP for nearly continuous analysis during the Probe descent and batch samples at several altitudes for GC analysis. It also contains a chemical scrubber for noble gas analysis and an enrichment cell for trace constituent enhancement. In addition to the sampling of the atmosphere periodic gas samples, derived from the pyrolysis of aerosols, will be transferred from the ACP to the GCMS for direct QP and full GCMS analysis. The QP can analyze molecular masses from 2 to 14lDalton. The nominal detection threshold is at a mixing ratio of 10E-8. Data rate is 885 bits/sec. The mass of the instrument is 17.3 kg and the energy required for operation during the descent is 110 Watt-hours.

Niemann, H. B.↗

Protein crystals and their growth

Recent results on the associations between protein molecules in crystal lattices, crystal-solution surface energy, elastic properties, strength, and spontaneous crystal cracking are reviewed and discussed. In addition, some basic approaches to understanding the solubility of proteins are followed by an overview of crystal nucleation and growth. It is argued that variability of mixing in batch crystallization may be a source of the variation in the number of crystals ultimately appearing in the sample. The frequency at which new molecules join a crystal lattice is measured by the kinetic coefficient and is related to the observed crystal growth rate. Numerical criteria used to discriminate diffusion- and kinetic-limited growth are discussed on this basis. Finally, the creation of defects is discussed with an emphasis on the role of impurities and convection on macromolecular crystal perfection.

Review↗

Performance of the CELSS Antarctic Analog Project (CAAP) crop production system

Regenerative life support systems potentially offer a level of self-sufficiency and a decrease in logistics and associated costs in support of space exploration and habitation missions. Current state-of-the-art in plant-based, regenerative life support requires resources in excess of allocation proposed for candidate mission scenarios. Feasibility thresholds have been identified for candidate exploration missions. The goal of this paper is to review recent advances in performance achieved in the CELSS Antarctic Analog Project (CAAP) in light of the likely resource constraints. A prototype CAAP crop production chamber has been constructed and operated at the Ames Research Center. The chamber includes a number of unique hardware and software components focused on attempts to increase production efficiency, increase energy efficiency, and control the flow of energy and mass through the system. Both single crop, batch production and continuous cultivation of mixed crops production studies have been completed. The crop productivity as well as engineering performance of the chamber are described. For each scenario, energy required and partitioned for lighting, cooling, pumping, fans, etc. is quantified. Crop production and the resulting lighting efficiency and energy conversion efficiencies are presented. In the mixed-crop scenario, with 27 different crops under cultivation, 17 m2 of crop area provided a mean of 515 g edible biomass per day (85% of the approximate 620 g required for one person). Enhanced engineering and crop production performance achieved with the CAAP chamber, compared with current state-of-the-art, places plant-based life support systems at the threshold of feasibility. c2002 Published by Elsevier Science Ltd on behalf of COSPAR.

Lettuce/growth & development↗

An all-silicon single-wafer micro-g accelerometer with a combined surface and bulk micromachining process

This paper reports an all-silicon fully symmetrical z-axis micro-g accelerometer that is fabricated on a single-silicon wafer using a combined surface and bulk fabrication process. The microaccelerometer has high device sensitivity, low noise, and low/controllable damping that are the key factors for attaining micro g and sub-micro g resolution in capacitive accelerometers. The microfabrication process produces a large proof mass by using the whole wafer thickness and a large sense capacitance by utilizing a thin sacrificial layer. The sense/feedback electrodes are formed by a deposited 2-3 microns polysilicon film with embedded 25-35 microns-thick vertical stiffeners. These electrodes, while thin, are made very stiff by the thick embedded stiffeners so that force rebalancing of the proof mass becomes possible. The polysilicon electrodes are patterned to create damping holes. The microaccelerometers are batch-fabricated, packaged, and tested successfully. A device with a 2-mm x 1-mm proof mass and a full bridge support has a measured sensitivity of 2 pF/g. The measured sensitivity of a 4-mm x 1-mm accelerometer with a cantilever support is 19.4 pF/g. The calculated noise floor of these devices at atmosphere are 0.23 micro g/sqrt(Hz) and 0.16 micro g/sqrt(Hz), respectively.

Non-NASA Center↗

Reverse osmosis filtration for space mission wastewater: membrane properties and operating conditions

Reverse osmosis (RO) is a compact process that has potential for the removal of ionic and organic pollutants for recycling space mission wastewater. Seven candidate RO membranes were compared using a batch stirred cell to determine the membrane flux and the solute rejection for synthetic space mission wastewaters. Even though the urea molecule is larger than ions such as Na+, Cl-, and NH4+, the rejection of urea is lower. This indicates that the chemical interaction between solutes and the membrane is more important than the size exclusion effect. Low pressure reverse osmosis (LPRO) membranes appear to be most desirable because of their high permeate flux and rejection. Solute rejection is dependent on the shear rate, indicating the importance of concentration polarization. A simple transport model based on the solution-diffusion model incorporating concentration polarization is used to interpret the experimental results and predict rejection over a range of operating conditions. Grant numbers: NAG 9-1053.

Non-NASA Center↗

Composting on Mars or the Moon: II. Temperature feedback control with top-wise introduction of waste material and air

Whereas Earth-based composting reactors that effectively control the process are batch operations with bottom-to-top airflow, in extraterrestrial application both the fresh waste and the air need to be introduced from above. Stabilized compost and used air would exit below. This materials flow pattern permits the addition of waste whenever generated, obviating the need for multiple reactors, and the incorporation of a commode in the lid. Top loading in turn dictates top-down aeration, so that the most actively decomposing material (greatest need for heat removal and O2 replenishment) is first encountered. This novel material and aeration pattern was tested in conjunction with temperature feedback process control. Reactor characteristics were: working, volume, 0.15 m3; charge, 2 kg dry biomass per day (comparable to a 3-4 person self-sufficient bioregenerative habitat); retention time, 7 days. Judging from temperature profile, O2 level, air usage, pressure head loss, moisture, and odor, the system was effectively controlled over a 35-day period. Dry matter disappearance averaged 25% (10-42%). The compost product was substantially, though not completely, stabilized. This demonstrates the compatibility of top-wise introduction of waste and air with temperature feedback process control.

NASA Discipline Life Support Systems↗

Density and composition of microorganisms during long-term (418 day) growth of potato using biologically reclaimed nutrients from inedible plant biomass

A study evaluating alternative methods for long term operation of biomass production systems was recently completed at the Kennedy Space Center (KSC). The 418-day study evaluated repeated batch versus mixed-aged production of potato grown on either standard 1/2-strength Hoagland's nutrient solution or solutions including nutrients recycled from inedible plant material. The long term effects of closure and recycling on microbial dynamics were evaluated by monitoring the microbial communities associated with various habitats within the plant growth system (i.e., plant roots, nutrient solution, biofilms within the hydroponic systems, atmosphere, and atmospheric condensate). Plate count methods were used to enumerate and characterize microorganisms. Microscopic staining methods were used to estunate total cell densities. The primary finding was that the density and composition of microbial communities associated with controlled environmental plant growth systems are stable during long term operation. Continuous production resulted in slightly greater stability. Nutrient recycling, despite the addition of soluble organic material from the waste processing system, did not significantly increase microbial density in any of the habitats.

NASA Center KSC↗

Simultaneous concentration and purification through gradient deformation chromatography

Mobile-phase additives, commonly used to modulate absorbate retention in gradient elution chromatography, are usually assumed to be either linearly retained or unretained. Previous theoretical work from our laboratory has shown that these modulators, such as salts in ion-exchange and hydrophobic interaction chromatography and organic modifiers in reversed-phase chromatography, can absorb nonlinearly, giving rise to gradient deformation. Consequently, adsorbate peaks that elute in the vicinity of the head of the deformed gradient may exhibit unusual shapes, form shoulders, and/or be concentrated. These effects for a reversed-phase sorbent with aqueous acetonitrile (ACN) as the modulator are verified experimentally. Gradient deformation is demonstrated experimentally and agrees with simulations based on ACN isotherm parameters that are independently determined from batch equilibrium studies using the layer model. Unusual absorbate peak shapes were found experimentally for single-component injections of phenylalanine, similar to those calculated by the simulations. A binary mixture of tryptophan and phenylalanine is used to demonstrate simultaneous concentration and separation, again in agreement with simulations. The possibility of gradient deformation in ion-exchange and hydrophobic interaction chromatography is discussed.

NASA Discipline Number 93-10↗

Solubility and cation exchange in phosphate rock and saturated clinoptilolite mixtures

Mixtures of zeolite and phosphate rock (PR) have the potential to provide slow-release fertilization of plants in synthetic soils by dissolution and ion-exchange reactions. This study was conducted to examine solubility and cation-exchange relationships in mixtures of PR and NH4- and K-saturated clinoptilolite (Cp). Batch-equilibration experiments were designed to investigate the effect of PR source, the proportion of exchangeable K and NH4, and the Cp to PR ratio on solution N, P, K, and Ca concentrations. The dissolution and cation-exchange reactions that occurred after mixing NH4- and K-saturated Cp with PR increased the solubility of the PR and simultaneously released NH4 and K into solution. The more reactive North Carolina (NC) PR rendered higher solution concentrations of NH4 and K when mixed with Cp than did Tennessee (TN) PR. Solution P concentrations for the Cp-NC PR mixture and the Cp-TN PR mixture were similar. Solution concentrations of N, P, K, and Ca and the ratios of these nutrients in solution varied predictably with the type of PR, the Cp/PR ratio, and the proportions of exchangeable K and NH4 on the Cp. Our research indicated that slow-release fertilization using Cp/PR media may provide adequate levels of N, P, and K to support plant growth. Solution Ca concentrations were lower than optimum for plant growth.

NASA Discipline Number 61-10↗

A direct viable count method for the enumeration of attached bacteria and assessment of biofilm disinfection

This report describes the adaptation of an in situ direct viable count (in situ DVC) method in biofilm disinfection studies. The results obtained with this technique were compared to two other enumeration methods, the plate count (PC) and conventional direct viable count (c-DVC). An environmental isolate (Klebsiella pneumoniae Kp1) was used to form biofilms on stainless steel coupons in a stirred batch reactor. The in situ DVC method was applied to directly assess the viability of bacteria in biofilms without disturbing the integrity of the interfacial community. As additional advantages, the results were observed after 4 h instead of the 24 h incubation time required for colony formation and total cell numbers that remained on the substratum were enumerated. Chlorine and monochloramine were used to determine the susceptibilities of attached and planktonic bacteria to disinfection treatment using this novel analytical approach. The planktonic cells in the reactor showed no significant change in susceptibility to disinfectants during the period of biofilm formation. In addition, the attached cells did not reveal any more resistance to disinfection than planktonic cells. The disinfection studies of young biofilms indicated that 0.25 mg/l free chlorine (at pH 7.2) and 1 mg/l monochloramine (at pH 9.0) have comparable disinfection efficiencies at 25 degrees C. Although being a weaker disinfectant, monochloramine was more effective in removing attached bacteria from the substratum than free chlorine. The in situ DVC method always showed at least one log higher viable cell densities than the PC method, suggesting that the in situ DVC method is more efficient in the enumeration of biofilm bacteria. The results also indicated that the in situ DVC method can provide more accurate information regarding the cell numbers and viability of bacteria within biofilms following disinfection.

NASA Discipline Number 04-10↗

Versatile Software Package For Near Real-Time Analysis of Experimental Data

This paper provides an overview of a versatile software package developed for time- and frequency-domain analyses of experimental wind-tunnel data. This package, originally developed for analyzing data in the NASA Langley Transonic Dynamics Tunnel (TDT), is applicable for analyzing any time-domain data. A Matlab-based software package, TDT-analyzer, provides a compendium of commonly-required dynamic analysis functions in a user-friendly interactive and batch processing environment. TDT-analyzer has been used extensively to provide on-line near real-time and post-test examination and reduction of measured data acquired during wind tunnel tests of aeroelastically-scaled models of aircraft and rotorcraft as well as a flight test of the NASA High Alpha Research Vehicle (HARV) F-18. The package provides near real-time results in an informative and timely manner far exceeding prior methods of data reduction at the TDT.

Wieseman, Carol D.↗

Characterizing the Hazard of a Wake Vortex Encounter

The National Aeronautics and Space Administration (NASA) is conducting research with the goal of enabling safe improvements in the capacity of the nation's air transportation system. The wake vortex upset hazard is an important factor in establishing the minimum safe spacing between aircraft during landing and take-off operations, thus impacting airport capacity. Static and free-flight wind tunnel tests and flight tests have provided an extensive data set for improved understanding of vortex encounter dynamics and simulation. Piloted and batch simulation studies are also ongoing to establish a first-order hazard metric and determine the limits of an operationally acceptable wake induced upset. This paper outlines NASA's research in these areas.

Vicroy, Dan D.↗

An Investigation to Improve Quality Evaluations of Primers and Propellant for 20mm Munitions

To reduce the frequency of electrically initiated, 20mm munition hangfires (delayed ignitions), a joint Army/NASA investigation was conducted to recommend quality evaluation improvements for acceptance of both primers and gun propellant. This effort focused only on evaluating ignition and combustion performance as potential causes of hangfires: poor electrical initiation of the primer, low output performance of the primer, low ignition sensitivity of the gun propellant, and the effects of cold temperature. The goal was to determine the "best" of the Army and NASA test methods to assess the functional performance of primers and gun propellants. The approach was to evaluate the performance of both high-quality and deliberately defective primers to challenge the sensitivity of test methods. In addition, the ignition sensitivity of different manufacturing batches of gun propellants was evaluated. The results of the investigation revealed that improvements can be made in functional evaluations that can assist in identifying and reducing ignition and performance variations. The "best" functional evaluation of primers and propellant is achieved through a combination of both Army and NASA test methods. Incorporating the recommendations offered in this report may provide for considerable savings in reducing the number of cartridge firings, while significantly lowering the rejection rate of primer, propellant and cartridge lots. The most probable causes for ignition and combustion-related hangfires were the lack of calcium silicide in the primer mix, a low output performance of primers, and finally, poor ignition sensitivity of gun propellant. Cold temperatures further reduce propellant ignition sensitivity, as well as reducing burn rate and chamber pressures.

Bement, L. J.↗

A Numerical Simulation Study to Develop an Acceptable Wake Encounter Boundary for a B737-100 Airplane

The National Aeronautics and Space Administration (NASA) is conducting research with the goal of enabling safe improvements in the capacity of the nation's air transportation system. The wake-vortex upset hazard is an important factor in establishing the minimum safe spacing between aircraft during landing and take-off operations, thus impacting airport capacity. A batch simulation study was conducted to assess the sensitivity of various safe landing criteria in the development of an acceptable wake encounter boundary. A baseline six-degree-of-freedom simulation of a B737-100 airplane was modified to include a wake model and the vortex-induced forces and moments. The guidance and control input for the airplane was provided by an auto-land system. The wake strength and encounter geometry were varied. A sensitivity study was also conducted to assess the effects of encounter modeling methods and accuracy.

Vicroy, Dan D.↗

A Grid Generation System for Multi-Disciplinary Design Optimization

A general multi-block three-dimensional volume grid generator is presented which is suitable for Multi-Disciplinary Design Optimization. The code is fast, robust, highly automated, and written in ANSI C for platform independence. Algebraic techniques are used to generate and/or modify block face and volume grids to reflect geometric changes resulting from design optimization. Volume grids are generated/modified in a batch environment and controlled via an ASCII user input deck. This allows the code to be incorporated directly into the design loop. Generated volume grids are presented for a High Speed Civil Transport (HSCT) Wing/Body geometry as well a complex HSCT configuration including horizontal and vertical tails, engine nacelles and pylons, and canard surfaces.

Jones, William T.↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗