Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SHAPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

SU-E-T-56: Brain Metastasis Treatment Plans for Contrast-Enhanced Synchrotron Radiation Therapy

Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The aim of this study is to compare dynamic stereotactic arc-therapy and iodineenhanced SSRT. Methods: Five patients bearing brain metastasis received a standard helical 3D-scan without iodine. A second scan was acquired 13 min after an 80 g iodine infusion. Two SSRT treatment plans (with/without iodine) were performed for each patient using a dedicated Monte Carlo (MC) treatment planning system (TPS) based on the ISOgray TPS. Ten coplanar beams (6×6 cm2, shaped with collimator) were simulated. MC statistical error objective was less than 5% in the 50% isodose. The dynamic arc-therapy plan was achieved on the Iplan Brainlab TPS. The treatment plan validation criteria were fixed such that 100% of the prescribed dose is delivered at the beam isocentre and the 70% isodose contains the whole target volume. The comparison elements were the 70% isodose volume, the average and maximum doses delivered to organs at risk (OAR): brainstem, optical nerves, chiasma, eyes, skull bone and healthy brain parenchyma. Results: The stereotactic dynamic arc-therapy remains the best technique in terms of dose conformation. Iodine-enhanced SSRT presents similar performances to dynamic arc-therapy with increased brainstem and brain parenchyma sparing. One disadvantage of SSRT is the high dose to the skull bone. Iodine accumulation in metastasis may increase the dose by 20–30%, allowing a normal tissue sparing effect at constant prescribed dose. Treatment without any iodine enhancement (medium-energy stereotactic radiotherapy) is not relevant with degraded HDVs (brain, parenchyma and skull bone) comparing to stereotactic dynamic arc-therapy. Conclusion: Iodine-enhanced SSRT exhibits a good potential for brain metastasis treatment regarding the dose distribution and OAR criteria.

60 APPLIED LIFE SCIENCES↗

An approximate solution for the free vibrations of rotating uniform cantilever beams

Approximate solutions are obtained for the uncoupled frequencies and modes of rotating uniform cantilever beams. The frequency approximations for flab bending, lead-lag bending, and torsion are simple expressions having errors of less than a few percent over the entire frequency range. These expressions provide a simple way of determining the relations between mass and stiffness parameters and the resultant frequencies and mode shapes of rotating uniform beams.

Peters, D. A.↗

DNA Break Clustering as a Predictor of Cell Death across Various Radiation Qualities: Influence of Cell Size, Cell Asymmetry, and Beam Orientation

Cosmic radiation, composed of high charge and energy (HZE) particles, causes cellular DNA damage that can result in cell death or mutation that can evolve into cancer. In this work, a cell death model is applied to several cell lines exposed to HZE ions spanning a broad range of linear energy transfer (LET) values. We hypothesize that chromatin movement leads to the clustering of multiple double strand breaks (DSB) within one radiation-induced foci (RIF). The survival probability of a cell population is determined by averaging the survival probabilities of individual cells, which is function of the number of pairwise DSB interactions within RIF. The simulation code RITCARD was used to compute DSB. Two clustering approaches were applied to determine the number of RIF per cell. RITCARD outputs were combined with experimental data from four normal human cell lines to derive the model parameters and expand its predictions in response to ions with LET ranging from ∼0.2keV/μmto∼3000keV/μm. Spherical and ellipsoidal nuclear shapes and two ion beam orientations were modeled to assess the impact of geometrical properties on cell death. The calculated average number of RIF per cell reproduces the saturation trend for high doses and high-LET values that is usually experimentally observed. The cell survival model generates the recognizable bell shape of LET dependence for the relative biological effectiveness (RBE). At low LET, smaller nuclei have lower survival due to increased DNA density and DSB clustering. At high LET, nuclei with a smaller irradiation area either because of a smaller size or a change in beam orientation have a higher survival rate due to a change in the distribution of DSB/RIF per cell. If confirmed experimentally, the geometric characteristics of cells would become a significant factor in predicting radiation-induced biological effects.

cell survival↗

Technical Note: A novel leaf sequencing optimization algorithm which considers previous underdose and overdose events for MLC tracking radiotherapy

Purpose: Multileaf collimator (MLC) tracking radiotherapy is complex as the beam pattern needs to be modified due to the planned intensity modulation as well as the real-time target motion. The target motion cannot be planned; therefore, the modified beam pattern differs from the original plan and the MLC sequence needs to be recomputed online. Current MLC tracking algorithms use a greedy heuristic in that they optimize for a given time, but ignore past errors. To overcome this problem, the authors have developed and improved an algorithm that minimizes large underdose and overdose regions. Additionally, previous underdose and overdose events are taken into account to avoid regions with high quantity of dose events. Methods: The authors improved the existing MLC motion control algorithm by introducing a cumulative underdose/overdose map. This map represents the actual projection of the planned tumor shape and logs occurring dose events at each specific regions. These events have an impact on the dose cost calculation and reduce recurrence of dose events at each region. The authors studied the improvement of the new temporal optimization algorithm in terms of the L1-norm minimization of the sum of overdose and underdose compared to not accounting for previous dose events. For evaluation, the authors simulated the delivery of 5 conformal and 14 intensity-modulated radiotherapy (IMRT)-plans with 7 3D patient measured tumor motion traces. Results: Simulations with conformal shapes showed an improvement of L1-norm up to 8.5% after 100 MLC modification steps. Experiments showed comparable improvements with the same type of treatment plans. Conclusions: A novel leaf sequencing optimization algorithm which considers previous dose events for MLC tracking radiotherapy has been developed and investigated. Reductions in underdose/overdose are observed for conformal and IMRT delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Section 1. Method of determining mode shapes and natural frequencies of the NASA unmodified test structure. Section 2. Continuous beam closed from solution to the NASA-LSS astromast torsional vibration, appendix E

The methods used to determine the lower natural frequencies and their corresponding mode shapes of the NASA-LSS Astromast (Unmodified Test Structure), and the mass integrals associated with the mode shapes are illustrated. The test structure is modeled as a cantilever beam with 91 lumped masses and without the tip mass on the free end of the bram. This uncouples the torsion and bending modes and allows for them to be determined separately. The frequency range was limited to an upper bound of 100 rad/sec (15.92 Hz.). In this range from 0.-100. rad/sec, three bending frequencies and one torsion frequency was found.

Source record↗

Modeling and optimization of single-pass laser amplifiers for high-repetition-rate laser pulses

We propose a model for a continuously pumped single-pass amplifier for continuous and pulsed laser beams. The model takes into account Gaussian shape and focusing geometry of pump and seed beam. As the full-wave simulation is complex we have developed a largely simplified numerical method that can be applied to rotationally symmetric geometries. With the tapered-shell model we treat (focused) propagation and amplification of an initially Gaussian beam in a gain crystal. The implementation can be done with a few lines of code that are given in this paper. With this code, a numerical parameter optimization is straightforward and example results are shown. We compare the results of our simple model with those of a full-wave simulation and show that they agree well. A comparison of model and experimental data also shows good agreement. We investigate in detail different regimes of amplification, namely the unsaturated, the fully saturated, and the intermediate regime. Because the amplification process is affected by spatially varying saturation and exhibits a nonlinear response against pump and seed power, no analytical expression for the expected output is available. For modeling of the amplification we employ a four-level system and show that if the fluorescence lifetime of the gain medium is larger than the inverse repetition rate of the seed beam, continuous-wave amplification can be employed to describe the amplification process of ultrashort pulse trains. We limit ourselves to this regime, which implies that if titanium:sapphire is chosen as gain medium the laser repetition rate has to be larger than a few megahertz. We show detailed simulation results for titanium:sapphire for a large parameter set.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mini-beam collimator enables micro-crystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, 25-50 {micro}m (FWHM) in the vertical and 50-100 {micro}m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 {micro}m x 65 {micro}m at the sample position. To meet growing user demand for beams to study samples of 10 {micro}m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 {micro}m or 10 {micro}m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

36 MATERIALS SCIENCE↗

High-throughput injection-acceleration of electron bunches from a linear accelerator to a laser wakefield accelerator

Plasma-based accelerators (PBAs) driven by either intense lasers (laser wakefield accelerators, LWFAs) or particle beams (plasma wakefield accelerators, PWFAs), can accelerate charged particles at extremely high gradients compared to conventional radio-frequency (RF) accelerators. In the past two decades, great strides have been made in this field, making PBA a candidate for next-generation light sources and colliders. However, these challenging applications necessarily require beams with good stability, high quality, controllable polarization and excellent reproducibility. To date, such beams are generated only by conventional RF accelerators. As such, it is important to demonstrate the injection and acceleration of beams first produced using a conventional RF accelerator, by a PBA. In some recent studies on LWFA staging and external injection-acceleration in PWFA only a very small fraction (from below 0.1% to few percent) of the injected charge (the coupling efficiency) was accelerated. For future colliders where beam energy will need to be boosted using multiple stages, the coupling efficiency per stage must approach 100%. Here we report the first demonstration of external injection from a photocathode-RF-gun-based conventional linear accelerator (LINAC) into a LWFA and subsequent acceleration without any significant loss of charge or degradation of quality, which is achieved by properly shaping and matching the beam into the plasma structure. Furthermore, this is an important step towards realizing a high-throughput, multi-stage, high-energy, hybrid conventional-plasma accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

EPICS Controlled Collimator for Controlling Beam Sizes in HIPPO

Controlling the beam spot size and shape in a diffraction experiment determines the probed sample volume. The HIPPO - High-Pressure-Preferred Orientation– neutron time-offlight diffractometer is located at the Lujan Neutron Scattering Center in Los Alamos National Laboratories. HIPPO characterizes microstructural parameters, such as phase composition, strains, grain size, or texture, of bulk (cm-sized) samples. In the current setup, the beam spot has a 10 mm diameter. Using a collimator, consisting of two pairs of neutron absorbing boron-nitride slabs, horizontal and vertical dimensions of a rectangular beam spot can be defined. Using the HIPPO robotic sample changer for sample motion, the collimator would enable scanning of e.g. cylindrical samples along the cylinder axis by probing slices of such samples. The project presented here describes implementation of such a collimator, in particular the motion control software. We utilized the EPICS (Experimental Physics Interface and Control System) software interface to integrate the collimator control into the HIPPO instrument control system. Using EPICS, commands are sent to commercial stepper motors that move the beam windows.

43 PARTICLE ACCELERATORS↗

Modulation of intensity emerging from zero effort (MIEZE) with extended Fourier time at large scattering angle

Modulation of Intensity Emerging from Zero Effort (MIEZE) is a neutron resonant spin echo technique that allows one to measure time correlation scattering functions in materials by implementing radio-frequency (RF) intensity modulation at the sample and the detector. The technique avoids neutron spin manipulation between the sample and the detector and, thus, could find applications in cases where the sample depolarizes the neutron beam. However, the finite sample size creates a variance in the path length between the locations where scattering and detection happen, which limits the contrast in intensity modulation that one can detect, in particular, toward long correlation times or large scattering angles. We propose a modification to the MIEZE setup that will enable one to extend those detection limits to longer times and larger angles. Furthermore, we use Monte Carlo simulations of a neutron scattering beamline to show that by tilting the RF flippers in the primary spectrometer with respect to the beam direction, one can shape the wave front of the intensity modulation at the sample to compensate for the path variance from the sample and the detector. The simulation results indicate that this change enables one to operate a MIEZE instrument at much increased RF frequencies, thus improving the effective energy resolution of the technique. For the MIEZE instrument simulated, it shows that for an incident beam with the maximum divergence of 0.33°, the maximum Fourier time can be increased by a factor of 3.

47 OTHER INSTRUMENTATION↗

Integrating Matrix Method for Determining the Natural Vibrations of a Rotating, Unsymmetrical Beam with Application to Twisted Propeller Blades

A numerical method is Presented for determining the natural vibration frequencies, and the corresponding mode shapes, of a rotating cantilever beam which has a nonuniform, unsymmetrical cross section. Two coupled fourth-order differential equations of motion with variable coefficients are derived which govern the motion of such a beam having deformations in two directions. Through the development and utilization of the integrating matrix, the solution of the differential equations is obtained in the form of an eigenvalue problem. The solutions to the eigenvalue problem are determined by an iteration method based upon a special orthogonality relationship which is derived. Numerical examples, including an application to a twisted propeller blade, are presented with the results of the integrating matrix solutions being compared to exact solutions and experimental data.

Hunter, William F.↗

Suppression of Deflecting Forces in Planar-Symmetric Dielectric Wakefield Accelerating Structures with Elliptical Bunches

Wakefield based accelerators capable of accelerating gradients two orders of magnitude higher than present accelerators offer a path to compact high energy physics instruments and light sources. However, for high gradient accelerators, beam instabilities driven by commensurately high transverse wakefields limit beam quality. It has been previously theoretically shown that transverse wakefields can be reduced by elliptically shaping the transverse sizes of beams in dielectric structures with planar symmetry. We report here experimental measurements that demonstrate reduced transverse wakefields for elliptical beams in planar symmetric structures which are consistent with theoretical models. Furthermore, these results may enable the design of gigavolt-per-meter gradient wakefield based accelerators that produce and stably accelerate high quality beams.

47 OTHER INSTRUMENTATION↗

Effects of proton irradiation on the microstructure and shape recovery characteristics of a NiTi alloy

Highlights: • The complex multilayer structure can be induced by irradiation. • Phase constitution with increased fluence evolved as follows: B19’ → (B19’ + B2 + Ti{sub 2}Ni) → (B2 + Ti{sub 2}Ni + TiH{sub 2}). • The transformation temperature decreases remarkablly with the increasing of irradiation fluence. • The strain recovery characteristics deteriorated significantly with the irradiation fluence increasing. - Abstract: Herein, we investigate the effects of proton irradiation on the structure and shape recovery characteristics of a NiTi alloy and provide a mechanistic explanation of the observed phenomena. Detailed analysis revealed that bombardment with 3 MeV protons induced the formation of a complex multilayer structure comprising TiH{sub 2}, Ti{sub 2}Ni, austenite and austenite-martensite layers along the irradiation direction with increasing distance and the origin of the above structure was shown to be closely related to the preferential sputtering effect and irradiation-induced segregation. Finally, the shape recovery characteristics significantly deteriorated with increasing irradiation fluence, since the multilayer structure hindered the martensitic transformation.

36 MATERIALS SCIENCE↗

Wide-field turbulence imaging with beam emission spectroscopy

Imaging of the size, shape, time-averaged, and time-resolved dynamics of long-wavelength density turbulence structures is accomplished with an expanded, high-sensitivity, wide-field beam emission spectroscopy (BES) diagnostic on DIII-D. A 64-channel BES system is configured with an 8x8 grid of discrete channels that image an approximately 7x9 cm region at the outboard midplane. The grid covers multiple correlation lengths and each channel shape matches the measured radial-poloidal correlation length asymmetry of turbulent eddies. The wide field 8x8 imaging capability allows for sampling of essentially the full two-dimensional spatial correlation function for typical plasma conditions. The sampled area can be radially scanned over 0.4<r/a<1, including the core (n-tilde/n<1%), pedestal, and scrape-off-layer. The resulting time-resolved visualizations of turbulence and flows provide critical data on turbulence dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of Ko Displacement Theory to the Deformed Shape Predictions of the Doubly-Tapered Ikhana Wing

The Ko displacement theory, formulated for weak nonuniform (slowly changing cross sections) cantilever beams, was applied to the deformed shape analysis of the doubly-tapered wings of the Ikhana unmanned aircraft. The two-line strain-sensing system (along the wingspan) was used for sensing the bending strains needed for the wing-deformed shapes (deflections and cross-sectional twist) analysis. The deflection equation for each strain-sensing line was expressed in terms of the bending strains evaluated at multiple numbers of strain-sensing stations equally spaced along the strain-sensing line. For the preflight shape analysis of the Ikhana wing, the strain data needed for input to the displacement equations for the shape analysis were obtained from the nodal-stress output of the finite-element analysis. The wing deflections and cross-sectional twist angles calculated from the displacement equations were then compared with those computed from the finite-element computer program. The Ko displacement theory formulated for weak nonlinear cantilever beams was found to be highly accurate in the deformed shape predictions of the doubly-tapered Ikhana wing.

Ko, William L.↗

Three-Flavor Neutrino Oscillations with MINOS+

This dissertation presents the analysis of the last two years of data from the MINOS+ long-baseline neutrino oscillation experiment. The analysis explores the data above the first oscillation maximum for neutrinos in the standard three-flavor neutrino oscillation model, adding significantly more neutrino events and constraining the model with increased precision. The analysis of the high-energy region of the MINOS+ data set, where previously there has been limited study, can help constrain alternative models or possibly show evidence of new phenomena. The predecessor to MINOS+, the MINOS experiment, measured $\nu_\mu$ disappearance and $\nu_{e}$ appearance using Fermilab's NuMI $\nu_\mu$ beam from 2005 to 2012. During this period the neutrino beam's energy spectrum was focused to peak near the first oscillation maximum. In addition to measuring accelerator beam neutrinos, the MINOS Far Detector collected a sample of atmospheric neutrinos from 2003 to 2011. With the se two samples, MINOS measured the atmospheric mass splitting, $\Delta{m}^2_{32}$, at the 5\% level and the value of $\sin^2\theta_{23}$ at the 15\% level. The data also constrained the CP violating parameter $\delta_{\rm CP}$. The MINOS+ experiment exposed the MINOS detectors to a neutrino beam peaked at energies above the oscillation maximum from 2013 to 2016. With this higher energy neutrino beam, MINOS+ measures the shape of the $\nu_\mu$ survival probability away from the oscillation maximum with unprecedented precision. Measuring the shape of the oscillation probability as a function of neutrino energy is an essential test of the three-flavor oscillation model. At these higher energies where the standard oscillation probability decreases, the neutrino energy spectrum is sensitive to potential perturbations from mixing with additional sterile neutrinos or non-standard neutrino interactions. This analysis of the complete data set from MINOS+ finds no significant deviatio ns from the three-flavor oscillation probability in the ener! gy region of 4 to 10\,GeV covered by the neutrino beam. This provides increased confidence in the three-flavor model in this region and provides new constraints of the atmospheric oscillation parameters, $\Delta{m}^2_{32}$ and $\sin^2\theta_{23}$, by combining the MINOS and MINOS+ data sets. The hierarchy of the neutrino masses is related to the sign of $\Delta{m}^2_{32}$. When $\Delta{m}^2_{32} > 0$, the mass hierarchy is classified as normal. When $\Delta{m}^2_{32} < 0$, the mass hierarchy is classified as inverted. This analysis cannot rule out either of the mass hierarchies. For the normal mass hierarchy, the combined analysis measures $\lvert{\Delta{m}^2_{32}}\rvert = 2.41\pm 0.09 \times 10^{-3}\,{\mathrm{eV}^2}$ at 68\% C.L. and $\sin^2\theta_{23} = 0.42_{-0.06}^{+0.23}$ at 90\% C.L. For the inverted mass hierarchy, this analysis measures $\lvert{\Delta{m}^2_{32}}\rvert = 2.47_{-0.10}^{+0.08} \times 10^{-3}\,{\mathrm{eV}^2}$ at 68\% C.L. and $\sin^2\theta_{23} = 0.42_{ -0.06}^{+0.23}$ at 90\% C.L. In addition to the analysis and measurement of the atmospheric oscillation parameters using MINOS+, this work updates the constraint on $\delta_{\rm CP}$ from MINOS and performs an exploratory combination using $\nu_\mu$ disappearance data from the NOvA experiment. The NOvA experiment uses the NuMI beam in an off-axis strategy that results in a narrow flux of muon neutrinos at the first oscillation maximum and allows precision measurements of the three-flavor parameters. Since NOvA and MINOS+ shared the same neutrino beam, their data can be combined taking advantage of common beam related uncertainties. Combined, the data from the MINOS, MINOS+, and NOvA experiments precisely map $\nu_\mu$ oscillation probabilities using the same neutrino beam in a way that could not be attempted before.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low energy, high power hydrogen neutral beam for plasma heating

A high power, relatively low energy neutral beam injector was developed to upgrade of the neutral beam system of the gas dynamic trap device and C2-U experiment. The ion source of the injector produces a proton beam with the particle energy of 15 keV, current of up to 175 A, and pulse duration of a few milliseconds. The plasma emitter of the ion source is produced by superimposing highly ionized plasma jets from an array of four arc-discharge plasma generators. A multipole magnetic field produced with permanent magnets at the periphery of the plasma box is used to increase the efficiency and improve the uniformity of the plasma emitter. Multi-slit grids with 48% transparency are fabricated from bronze plates, which are spherically shaped to provide geometrical beam focusing. The focal length of the Ion Optical System (IOS) is 3.5 m and the initial beam diameter is 34 cm. The IOS geometry and grid potentials were optimized numerically to ensure accurate beam formation. The measured angular divergences of the beam are ±0.01 rad parallel to the slits and ±0.03 rad in the transverse direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of a throttlable 15 cm hollow cathode ion thruster

The use of dished high perveance grids on a 15 cm modified SERT 2 thruster is shown to facilitate throttled operation over a beam current range from 60 to 600 mA. Effects of increasing the radial component of the magnetic field in the main discharge chamber and decreasing the dimensions of the cathode discharge region are examined and found to degrade performance to the extent that primary electrons are forced in toward the center-line of the thruster. Studies of the baffle aperture region of two thrusters indicate that the electric potential gradient vector is perpendicular to the local magnetic field lines when the thruster is operating properly. The correlation between the shape of the ion beam current density and that of the ion density at the screen grid within the thruster is shown to be 94%. Additional experimental studies on maximum propellant utilization, plasma ion production cost, neutral density in the cathode discharge region, double ion production in hollow cathode thrusters and thermal flow meter performance are discussed.

Wilbur, P. J.↗