Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Evaluating the Role of Pre-Application Reports in Improving Distributed Generation Interconnection Processes

Several tools have emerged in recent years to increase data exchange and transparency in the distributed generation interconnection process with the goal of reducing interconnection costs. One example is pre-application reports. These reports are generated by a utility at the request of prospective interconnection applicants to provide technical information about a specific point of interconnection. Formal pre-application report processes have been established in 12 states at the distribution system level as well as at the transmission level by the Federal Energy Regulatory Commission. These reports are a relatively low-cost method of informing applicants of grid conditions and potential interconnection limitations early in the interconnection process. Thus, this information may encourage interconnection in locations with little to no detrimental impact to the grid and low interconnection costs. Increasing transparency of these grid conditions may also enable applicants to better plan for interconnection costs and requirements, such as system modifications and complex engineering studies. By providing these benefits, pre-application reports are expected to reduce the number of canceled interconnection applications. This report evaluates this hypothesis by quantifying the impact pre-application report processes have on application approval rate. To evaluate this hypothesis this analysis uses utility-reported distributed generation interconnection data from four utilities in Massachusetts. The analysis considers a four-year time period before and a five-year period after pre-application report process were implemented. The results indicate that once pre-application reports were required for projects 500 kilowatts and larger the approval rate of applications increased by 24%. This suggests that pre-application reports may decrease the percentage of canceled projects. However, due to data and other limitations, these results do not necessarily connote causation. This analysis is an important first step and a prerequisite for future analyses regarding the impact of pre-application reports. Other potential impacts also recognized during this analysis included reducing sunk costs and reducing the number of projects requiring a complex review. Collection of additional data would allow for forming more robust conclusions about these impacts in the future. Such data include circuit-level data, interconnection cost data, policy and regulatory background, national-level data, and utility and developer attributes. These data provide necessary context to account for interrelated factors while evaluating pre-application reports. Filling such knowledge gaps ultimately aids regulators in applying best practices within the industry. As more and more distributed energy resources are interconnected, these best practices will become an integral aspect of efficiently transitioning to an electric grid capable of meeting the needs of the 21st century.

14 SOLAR ENERGY↗

SU-E-T-254: Development of a HDR-BT QA Tool for Verification of Source Position with Oncentra Applicator Modeling

Purpose: To develop a High Dose Rate Brachytherapy (HDR-BT) quality assurance (QA) tool for verification of source position with Oncentra applicator modeling, and to report the results of radiation source positions with this tool. Methods: We developed a HDR-BT QA phantom and automated analysis software for verification of source position with Oncentra applicator modeling for the Fletcher applicator used in the MicroSelectron HDR system. This tool is intended for end-to-end tests that mimic the clinical 3D image-guided brachytherapy (3D-IGBT) workflow. The phantom is a 30x30x3 cm cuboid phantom with radiopaque markers, which are inserted into the phantom to evaluate applicator tips and reference source positions; positions are laterally shifted 10 mm from the applicator axis. The markers are lead-based and scatter radiation to expose the films. Gafchromic RTQA2 films are placed on the applicators. The phantom includes spaces to embed the applicators. The source position is determined as the distance between the exposed source position and center position of two pairs of the first radiopaque markers. We generated a 3D-IGBT plan with applicator modeling. The first source position was 6 mm from the applicator tips, and the second source position was 10 mm from the first source position. Results: All source positions were consistent with the exposed positions within 1 mm for all Fletcher applicators using in-house software. Moreover, the distance between source positions was in good agreement with the reference distance. Applicator offset, determined as the distance from the applicator tips at the first source position in the treatment planning system, was accurate. Conclusion: Source position accuracy of applicator modeling used in 3D-IGBT was acceptable. This phantom and software will be useful as a HDR-BT QA tool for verification of source position with Oncentra applicator modeling.

60 APPLIED LIFE SCIENCES↗

SmartApps: Middle-ware for Adaptive Applications on Reconfigurable Platforms

There are several reasons why the performance of current distributed and heterogeneous systems is often disappointing. For example, the characteristics of the application may be input sensitive and evolve during execution causing dramatic changes in memory reference patterns, resource requirements, or degree of concurrency between different phases of the computation. Or, the system may change dynamically with nodes failing or appearing, some network links severed and other links established with different latencies and bandwidths. Another important reason for poor performance is the fairly compartmentalized approach to optimization: applications, compilers, operating systems and hardware configurations are designed and optimized in isolation and without the knowledge of instance specific information and needs of a running application. There is too little information flow across these boundaries and no global optimization is even attempted. For example, most operating systems services like paging, virtual-to-physical page mapping, I/O, or data layout in disks, provide little or no application customization. Similarly, the off-the-shelf hardware used by most commercial systems is optimized to give best average-case performance. To address this problem, we have proposed application-centric computing, or Smart Applications (SAS). In the SAS executable, the compiler embeds most run-time system services, and a performance-optimizing feedback loop that monitors the application's performance and adaptively reconfigures the application and the OS/system platform. At run-time, after incorporating the code's input and determining the system's resources and state, the SAS performs an *instance* specific optimization, which is more tractable than a global generic optimization between application, OS and system. The overriding philosophy of SAS is ``measure, compare, and adapt if beneficial.'' That is, the application will continually monitor its performance and the available resources to determine if, and by how much, performance could be improved if the application was restructured. Then, if the potential performance benefit outweighs the projected overhead costs, the application will restructure itself and the underlying system accordingly. The SAS framework includes performance monitoring and modeling components and mechanisms for performing the actual restructuring at various levels including: (i) algorithmic adaptation, (ii) run-time software optimization (e.g., input sensitivity analysis, etc.), (iii) tuning reconfigurable OS services (scheduling policy, page size, etc), and (iv) system configuration (e.g., selecting which, and how many, computational resources to use). SmartApps is being developed in the STAPL infrastructure. STAPL (the Standard Template Adaptive Parallel Library) is a framework for developing highly-optimizable, adaptable, and portable parallel and distributed applications. It consists of a relatively new and still evolving collection of generic parallel algorithms and distributed containers and a run-time system (RTS) through which the application and compiler interact with the OS and hardware.

97 MATHEMATICS AND COMPUTING↗

Wearable Sensor Application for Integrated Early Warning and Health Surveillance

Objective: The Wearable Sensor Application developed by Pacific Northwest National Laboratory (PNNL) provides an early warning system for stressors to individual and group health using physiologic and environmental indicators. The application integrates health monitoring parameters from wearable sensors, e.g., temperature and heart rate, with relevant environmental parameters, e.g., weather and landscape data, and calculates the corresponding physiological strain index. The information is presented to the analyst in a group and individual view with real-time alerting of abnormal health parameters. This application is the first of its kind being developed for integration into the Defense Threat Reduction Agency's Biosurveillance Ecosystem (BSVE).Introduction: Wearable devices are a low cost, minimally invasive way to monitor health. Sensor data provides real-time physiological indictors of an individual’s health status without the requirement of health care professionals or facilities. Information gleamed from wearable sensors can be used to better understand physiological stressors and prodromal symptoms. In addition, this data can be used to monitor individuals that are in high risk of health-related problems.However, raw data from wearable sensors can be overwhelming to process and laborious to monitor for an individual and, even more so, for a group of individuals. Often specific combination of ranges of sensor readings are indicative of changes to health status and need to be evaluated together or used to calculate specific signal parameters. In addition, the environment surrounding the individual needs to be considered when interpreting the data. To address these issues, PNNL has developed an application that collects, analyzes, and integrates wearable sensor data with geographic landscape and weather information to provide a real-time early alert and situational awareness tool for monitoring the health of groups and individuals.Methods: The prototype application described here was a product of PNNL’s BSVE Application Development Competition. The final product that will be deployed in the BSVE is currently under development by PNNL and will vary slightly in the exact design and architecture described.Data. Wearable sensor data was collected from the Rim2Rim (R2R) Watch Study of individuals hiking the Grand Canyon in Arizona [1]. Weather information was obtained from nearby weather stations and mapping features were derived from Google Maps.Calculations. A physiological Strain Index (PSI) was calculated using core temperature estimates derived through a Kalman Filter approach and heart rate [2,3].Application. The prototype backend application development was based in Python with a MongoDB. The front-end development was built using a scalable architecture and modular approach with components in React and D3.Results: A prototype application was developed this past summer through the PNNL BSVE App Competition (Fig 1). The application was aimed at visualizing wearable sensor data from the Grand Canyon R2R hike dataset. Simulated real-time analysis was used to calculate health status of individuals hiking based on measured physiological parameters and to alert to individuals with signs of physiologic health stress. Visualization tools were incorporated to enable sensor data for individuals and the group to be viewed simultaneously along with pertinent weather, geographic, and elevation data.Many features described in the prototype application will be incorporated into the final BSVE application. The key changes will be 1) the ability to select given time periods for viewing historical data as well as the real-time data collection, 2) environmental data and map view will come from BSVE internal data sources, and 3) the alerts will provide more information and have their own page for reviewing.Conclusions: The Wearable Sensor Application developed by PNNL for integration into the BSVE provides an early warning system for individual and group health using physiologic and environmental parameters. The application highlights health status from wearable sensors and relevant environmental parameters while monitoring a calculated physiological strain index. With this tool, an analyst can easily monitor the health of individuals and groups with the aid of real-time alerting tool for early detection of abnormal health parameters.

Early Warning↗

Proxy Applications for Converged Workloads: DMC LDRD Initiative

Modern scientific applications are complicated and require coordination of several components. Proxy application driven software-hardware co-design plays a vital role in driving innovation among the developments of applications, software infrastructure and hardware architecture. Proxy applications are self-contained and simplified codes that are intended to model the performance-critical computations within applications. Applications executing on modern High Performance Computing (HPC) systems are susceptible to network congestion, insufficient memory bandwidth within and across compute nodes, and inadvertent loss of performance due to bugs and unoptimized programming models. Modern numerical simulations and machine learning models play a critical role in studying physical phenomenon under myriad uncertainties. Such applications often exhibit irregular computation and memory accesses at specific regions of the application code, which can contribute to various performance bottlenecks at scale. To mitigate such issues and prepare the next generation hardware for a variety of computation and data movement contingencies, a well-known practice is to consider "proxy" applications as representative motifs for various classes of scientific applications. While there is disagreement in the HPC community on the mechanisms of construction of the proxy applications, there is a strong consensus on their positive impact in co-design. Proxy Applications for Converged Workloads (PACER) is about facilitating software-hardware co-design through proxy applications with the goal of improving the performance of converged science workflows on heterogeneous systems.

97 MATHEMATICS AND COMPUTING↗

Design and evaluation of a HDR skin applicator with flattening filter

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure the output of the applicators by the user using an insert into a well chamber. The MC GEANT4 code has been used to design the filters and to obtain the dose rate distributions in liquid water for the two Leipzig+filter applicators. In order to validate this specific application and to guarantee that realistic source-applicator geometry has been considered, an experimental verification procedure was implemented in this study, in accordance with the updated recommendations of the American Association of Physicists in Medicine Task Group No. 43 U1 Report. Thermoluminescent dosimeters, radiochromic film, and a pin-point ionization chamber in a plastic [polymethylmethacrylate (PMMA)] phantom were used to verify the MC results for the two applicators of a microSelectron-HDR afterloader with the mHDR-v2 source. To verify the output of the Leipzig+filter applicators, correspondence factors were deduced for the well chambers HDR100-plus (Standard Imaging, Inc., Middleton, WI) and TM33004 (PTW, Freiburg, Germany) using a specific insert for both applicators. The doses measured in the PMMA phantom agree within experimental uncertainties with the dose obtained by the MC calculations. Percentage depth dose and off-axis profiles were obtained normalized at a depth of 3 mm along the central applicator axis in a cylindrical 20x20 cm water phantom. A table of output factors, normalized to 1 U of source air kerma strength at this depth, is presented. Correspondence factors were obtained for the two well chambers considered. The matrix data obtained in the MC simulation with a grid separation of 0.5 mm has been used to build a data set in a convenient format to model these distributions for routine use with a brachytherapy treatment planning system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-26: The CT Compatibility of a Novel Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer

Purpose: To examine CT metal image artifact from a novel direction-modulated brachytherapy (DMBT) tandem applicator (95% tungsten) for cervical cancer using a commercially available orthopedic metal artifact reduction (O-MAR) algorithm. Comparison to a conventional stainless steel applicator is also performed. Methods: Each applicator was placed in a water-filled phantom resembling the female pelvis and scanned in a Philips Brilliance 16-slice CT scanner using two pelvis protocols: a typical clinical protocol (120kVp, 16×0.75mm collimation, 0.692 pitch, 1.0s rotation, 350mm field of view (FOV), 600mAs, 1.5mm slices) and a protocol with a higher kVp and mAs setting useful for larger patients (140kVp, 16×0.75mm collimation, 0.688 pitch, 1.5s rotation, 350mm FOV, 870mAs, 1.5mm slices). Images of each tandem were acquired with and without the application of the O-MAR algorithm. Baseline scans of the phantom (no applicator) were also collected. CT numbers were quantified at distances from 5 to 30 mm away from the applicator’s edge (in increments of 5mm) using measurements at eight angles around the applicator, on three consecutive slices. Results: While the presence of both applicators degraded image quality, the DMBT applicator resulted in larger streaking artifacts and dark areas in the image compared to the stainless steel applicator. Application of the O-MAR algorithm improved all acquired images, both visually and quantitatively. The use of low and high kVp and mAs settings (120 kVp/600mAs and 140 kVp/870mAs) in conjunction with the O-MAR algorithm lead to similar CT numbers in the vicinity of the applicator and a similar reduction of the induced metal artifact. Conclusion: This work indicated that metal artifacts induced by the DMBT and the stainless steel applicator are greatly reduced when using the O-MAR algorithm, leading to better quality phantom images. The use of a high dose protocol provided similar improvements in metal artifacts compared to the clinical protocol.

60 APPLIED LIFE SCIENCES↗

SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported.

60 APPLIED LIFE SCIENCES↗

SU-F-T-28: Evaluation of BEBIG HDR Co-60 After-Loading System for Skin Cancer Treatment Using Conical Surface Applicator

Purpose: To evaluate the possibility of utilizing the BEBIG HDR 60Co remote after-loading system for malignant skin surface treatment using Monte Carlo (MC) simulation technique. Methods: First TG-43 parameters of BEBIG-Co-60 and Nucletron Ir-192-mHDR-V2 brachytherapy sources were simulated using MCNP6 code to benchmark the sources against the literature. Second a conical tungsten-alloy with 3-cm diameter of Planning-Target-Volume (PTV) at surface for use with a single stepping HDR source is designed. The HDR source is modeled parallel to treatment plane at the center of the conical applicator with a source surface distance (SSD) of 1.5-cm and a removable plastic end-cap with a 1-mm thickness. Third, MC calculated dose distributions from HDR Co-60 for conical surface applicator were compared with the simulated data using HDR Ir-192 source. The initial calculations were made with the same conical surface applicator (standard-applicator) dimensions as the ones used with the Ir-192 system. Fourth, the applicator wall-thickness for the Co-60 system was increased (doubled) to diminish leakage dose to levels received when using the Ir-192 system. With this geometry, percentage depth dose (PDD), and relative 2D-dose profiles in transverse/coronal planes were normalized at 3-mm prescription-depth evaluated along the central axis. Results: PDD for Ir-192 and Co-60 were similar with standard and thick-walled applicator. 2D-relative dose distribution of Co-60, inside the standard-conical-applicator, generated higher penumbra (7.6%). For thick-walled applicator, it created smaller penumbra (<4%) compared to Ir-192 source in the standard-conicalapplicator. Dose leakage outside of thick-walled applicator with Co-60 source was approximately equal (≤3%) with standard applicator using Ir-192 source. Conclusion: Skin cancer treatment with equal quality can be performed with Co-60 source and thick-walled conical applicators instead of Ir-192 with standard applicators. These conical surface applicator must be used with a protective plastic end-cap to eliminate electron contamination and over-dosage of the skin.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-10: Feasibility of Newly Designed Applicator for High Dose Rate Brachytherapy Treatment of Patients with Vaginal Vault Recurrence

Purpose: To compare the dose of an in-house 3D-printed gynecology applicator (TMHGA) for vaginal vault recurrence of corpus cancer patients after operation for high dose rate brachytherapy treatment with commercially available applicators. Methods: A newly designed applicator is made from 3D-printing methods using ABSM30i. The isodose of the applicator is compared with Elekta multi-channel (MC) applicator and titanium Rotterdam applicator with coupling central tube and vaginal cylinder (RC). Three plans are created using three applicators in a CT set of water phantom. The applicators are anchored using the applicator library and implant library in the Elekta Oncentra treatment planning system (ver.4.5). The rectum is mimicked by creating a 2cm diameter cylinder, with a distance 1mm posteriorly away from the high risk CTV (HR-CTV). Similarly, the bladder is replicated by a 6cm diameter cylinder with distance 1mm anteriorly from the HR-CTV. Three plans are all normalized 1.5cm superior, 0.5cm anterior and 0.5cm posterior of the applicator surface. By fixing D90 of HR-CTV to 6Gy, the D2cc of rectum and bladder of three plans are compared. Results: The D2cc of the bladder for using TMHGA is lower than MC and RC by 14.0% and 11.9% respectively. While the D2cc of the rectum for using TMHGA is lower than MC and RC by 18.9% and 12.4% respectively. The total treatment time of TMHGA plan is shorter than MC and RC by 11.2% and 12.9%. Conclusion: The applicator created via 3D printing delivers a lower dose to the bladder and the rectum while keeping the same coverage to HR-CTV as other commercially available applicators. Additionally, the new applicator resulted in a reduction of treatment time, which is always welcome.

60 APPLIED LIFE SCIENCES↗

Towards a Scalable and Adaptive Application Support Platform for Large-Scale Distributed E-Sciences in High-Performance Network Environments

The advent of large-scale collaborative scientific applications has demonstrated the potential for broad scientific communities to pool globally distributed resources to produce unprecedented data acquisition, movement, and analysis. System resources including supercomputers, data repositories, computing facilities, network infrastructures, storage systems, and display devices have been increasingly deployed at national laboratories and academic institutes. These resources are typically shared by large communities of users over Internet or dedicated networks and hence exhibit an inherent dynamic nature in their availability, accessibility, capacity, and stability. Scientific applications using either experimental facilities or computation-based simulations with various physical, chemical, climatic, and biological models feature diverse scientific workflows as simple as linear pipelines or as complex as a directed acyclic graphs, which must be executed and supported over wide-area networks with massively distributed resources. Application users oftentimes need to manually configure their computing tasks over networks in an ad hoc manner, hence significantly limiting the productivity of scientists and constraining the utilization of resources. The success of these large-scale distributed applications requires a highly adaptive and massively scalable workflow platform that provides automated and optimized computing and networking services. This project is to design and develop a generic Scientific Workflow Automation and Management Platform (SWAMP), which contains a web-based user interface specially tailored for a target application, a set of user libraries, and several easy-to-use computing and networking toolkits for application scientists to conveniently assemble, execute, monitor, and control complex computing workflows in heterogeneous high-performance network environments. SWAMP will enable the automation and management of the entire process of scientific workflows with the convenience of a few mouse clicks while hiding the implementation and technical details from end users. Particularly, we will consider two types of applications with distinct performance requirements: data-centric and service-centric applications. For data-centric applications, the main workflow task involves large-volume data generation, catalog, storage, and movement typically from supercomputers or experimental facilities to a team of geographically distributed users; while for service-centric applications, the main focus of workflow is on data archiving, preprocessing, filtering, synthesis, visualization, and other application-specific analysis. We will conduct a comprehensive comparison of existing workflow systems and choose the best suited one with open-source code, a flexible system structure, and a large user base as the starting point for our development. Based on the chosen system, we will develop and integrate new components including a black box design of computing modules, performance monitoring and prediction, and workflow optimization and reconfiguration, which are missing from existing workflow systems. A modular design for separating specification, execution, and monitoring aspects will be adopted to establish a common generic infrastructure suited for a wide spectrum of science applications. We will further design and develop efficient workflow mapping and scheduling algorithms to optimize the workflow performance in terms of minimum end-to-end delay, maximum frame rate, and highest reliability. We will develop and demonstrate the SWAMP system in a local environment, the grid network, and the 100Gpbs Advanced Network Initiative (ANI) testbed. The demonstration will target scientific applications in climate modeling and high energy physics and the functions to be demonstrated include workflow deployment, execution, steering, and reconfiguration. Throughout the project period, we will work closely with the science communities in the fields of climate modeling and high energy physics including Spallation Neutron Source (SNS) and Large Hadron Collider (LHC) projects to mature the system for production use.

97 MATHEMATICS AND COMPUTING↗

Accelerating Parallel Applications in Cloud Platforms via Adaptive Time-Slice Control

Cloud platforms can provide flexible and cost-effective environments for parallel applications. However, the resource over-commitment issues, i.e., cloud providers often provide much more executable virtual CPUs than available physical CPUs, still impede the synchronization operations of parallel applications, causing severe performance degradation. Existing methods optimize parallel applications by promoting the priorities of involved VMs. They cannot fully explore the performance of parallel applications, because they ignore the time-slice requirements of different phases of parallel applications. Furthermore, non-parallel applications experience unsatisfied performance because of low scheduling priorities. Given empirical analysis on time-slices of virtual machines (VMs), we find that shortening time-slices can mitigate synchronization overhead which incurs during communication phases, while over-short time-slices cause frequent cache misses in computation phases. Accordingly, we propose an Adaptive Time-slice Control (ATC) mechanism. ATC first detects the phases of parallel applications based on lock latency or cache misses. Then, ATC shortens time-slices during communication phases and prolongs time-slices during computation phases for parallel applications, and sets a uniform time-slice for non-parallel applications. Finally, we evaluate ATC using seven well-known benchmarks with 25+ applications. Experiments show that ATC obtains 1.5-75x performance gain for running parallel applications than state-of-the-art solutions, with nearly unaffected impact on non-parallel applications.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-297: Dosimetric Assessment of An Air-Filled Balloon Applicator in HDR Vaginal Cuff Brachytherapy Using the Monte Carlo Method

Purpose: As an alternative to cylindrical applicators, air inflated balloon applicators have been introduced into HDR vaginal cuff brachytherapy treatment to achieve sufficient dose to vagina mucosa as well as to spare rectum and bladder. In general, TG43 formulae based treatment planning systems do not take into account tissue inhomogeneity, and air in the balloon applicator can cause higher delivered dose to mucosa than treatment plan reported. We investigated dosimetric effect of air in balloon applicator using the Monte Carlo method. Methods: The thirteen-catheter Capri applicator with a Nucletron Ir-192 seed was modeled for various balloon diameters (2cm to 3.5cm) using the MCNP Monte Carlo code. Ir-192 seed was placed in both central and peripheral catheters to replicate real patient situations. Existence of charged particle equilibrium (CPE) with air balloon was evaluated by comparing kerma and dose at various distances (1mm to 70mm) from surface of air-filled applicator. Also mucosa dose by an air-filled applicator was compared with by a water-filled applicator to evaluate dosimetry accuracy of planning system without tissue inhomogeneity correction. Results: Beyond 1mm from air/tissue interface, the difference between kerma and dose was within 2%. CPE (or transient CPE) condition was deemed existent, and in this region no electron transport was necessary in Monte Carlo simulations. At 1mm or less, the deviation of dose from kerma became more apparent. Increase of dose to mucosa depended on diameter of air balloon. The increment of dose to mucosa was 2.5% and 4.3% on average for 2cm and 3.5cm applicators, respectively. Conclusion: After introduction of air balloon applicator, CPE fails only at the proximity of air/tissue interface. Although dose to mucosa is increased, there is no significant dosimetric difference (<5%) between air and water filled applicators. Tissue inhomogeneity correction is not necessary for air-filled applicators.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-07: Dosimetric Verification of the Valencia Skin Applicator Using Gafchromic EBT3 Film

Purpose: The Valencia applicators have recently been introduced for HDR treatment of small and shallow superficial skin lesions (< 20 mm diameter and 3-mm depth). Per AAPM TG 56, any HDR applicator internal dimensions must be verified prior to clinical use. However radiographic and tomographic imaging to validate the Valencia applicators is impractical due to the Tungsten alloy housing and flattening filter. In this study, we propose to use EBT3 film to indirectly confirm the physical integrity of the Valencia applicators. Methods: Treatment plans were created using the Oncentra MasterPlan TPS v4.5 for the H2 (20-mm dia.) and H3 (30-mm dia.) Valencia Applicators. A virtual CT phantom (2-mm slice thickness) was created with one source position in water. The published effective depth method was used for each applicator to delivery 500 cGy to a 3-mm depth using the TG-43 formalism. Film measurements (n=3) at 3-mm depth and vertical plane in solid water were performed for each applicator to verify the prescribed dose calculated by the TPS. Percent depth dose curves and off-axis profiles (phantom surface and 3-mm depth) were measured and compared to published data. Films were analyzed using an in-house written program and RIT113 v6 software. Film calibration was performed per TG-55 protocol using the Ir-192 source with NIST-traceable calibration. Results: The prescription absolute dose difference was 1% for the Valencia H2 applicator and 4% for the Valencia H3 applicator. The measured percent depth dose curves and off-axis dose profiles measured for the H2 and H2 Valencia applicators are in excellent agreement with the Granero et al. Monte Carlo results{sup 1}. Conclusion: Gafchromic EBT3 film can be used to indirectly verify the internal components of special HDR skin applicators constructed from high Z materials.{sup 1}Granero et al. “Design and evaluation of a HDR skin applicator with flattening filter”, Med. Phys. 35(2), 495–503, 2008.

60 APPLIED LIFE SCIENCES↗

Monitoring applications once they are in the user community

Once an application is released into the user community, obtaining prompt and high quality information on application usage, applicability and reliability can be a challenge. Most Linux and Solaris applications used at RHIC and associated accelerators have been instrumented so that application and crash information is gathered, stored and forwarded to the appropriate developer for immediate analysis. To support this process, databases were created to track developer and application information. In order to keep these databases relevant, a web based application release procedure was created to collect information and automatically update the database. Additional capabilities have been developed that utilize and expand on the various components of this system to promote communication between developers and users, and to monitor applications. An application feedback feature allows users to instantly communicate with application developers. An application history system records application usage and reliability.

43 PARTICLE ACCELERATORS↗

Understanding the Impact of Dynamic Power Capping on Application Progress

Electrical power has become an important design constraint in high-performance computing (HPC) systems. On future HPC machines, power is likely to be a budgeted resource and thus managed dynamically. Power management software needs to reliably measure application performance at runtime in order to respond effectively to changes in application behavior. Execution time tells us little about how the science in the application is progressing toward an application-defined end goal. To the best of our knowledge, no study has defined or categorized online application progress in the context of power management. Based on semi-structured interviews with HPC application-specialists, we define an online notion of progress—an application-specific metric that can be monitored at runtime to provide a sense of the rate at which application science is being performed. Using instrumentation, we characterize and categorize the progress of various production scientific applications and benchmarks. We propose a model of the impact of dynamic power capping on application progress. By experimental evaluation, we show that our model accurately captures the general behavior of the progress of different classes of applications under a power cap. We believe that such a model is an important first step toward the design of more dynamic power management policies for HPC systems.

application progress↗

Development of a high precision dosimetry system for the measurement of surface dose rate distribution for eye applicators

Purpose: The therapeutic outcome of the therapy with ophthalmic applicators is highly dependent on the application of a sufficient dose to the tumor, whereas the dose applied to the surrounding tissue needs to be minimized. The goal for the newly developed apparatus described in this work is the determination of the individual applicator surface dose rate distribution with a high spatial resolution and a high precision in dose rate with respect to time and budget constraints especially important for clinical procedures. Inhomogeneities of the dose rate distribution can be detected and taken into consideration for the treatment planning. Methods: In order to achieve this, a dose rate profile as well as a surface profile of the applicator are measured and correlated with each other. An instrumental setup has been developed consisting of a plastic scintillator detector system and a newly designed apparatus for guiding the detector across the applicator surface at a constant small distance. It performs an angular movement of detector and applicator with high precision. Results: The measurements of surface dose rate distributions discussed in this work demonstrate the successful operation of the measuring setup. Measuring the surface dose rate distribution with a small distance between applicator and detector and with a high density of measuring points results in a complete and gapless coverage of the applicator surface, being capable of distinguishing small sized spots with high activities. The dosimetrical accuracy of the measurements and its analysis is sufficient (uncertainty in the dose rate in terms of absorbed dose to water is <7%), especially when taking the surgical techniques in positioning of the applicator on the eyeball into account. Conclusions: The method developed so far allows a fully automated quality assurance of eye applicators even under clinical conditions. These measurements provide the basis for future calculation of a full 3D dose rate distribution, which then can be used as input for a refined clinical treatment planning system. The improved dose rate measurements will facilitate a clinical study, which could correlate the therapeutic outcome of a brachytherapy treatment with an applicator and its individual dose rate distribution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric optimization of a conical breast brachytherapy applicator for improved skin dose sparing

Purpose: Both the AccuBoost D-shaped and round applicators have been dosimetrically characterized and clinically used to treat patients with breast cancer. While the round applicators provide conformal dose coverage, under certain clinical circumstances the breast skin dose may be higher than preferred. The purpose of this study was to modify the round applicators to minimize skin dose while not substantially affecting dose uniformity within the target volume and reducing the treatment time. Methods: In order to irradiate the intended volume while sparing critical structures such as the skin, the current round applicator design has been augmented through the addition of an internal truncated cone (i.e., frustum) shield. Monte Carlo methods and clinical constraints were used to design the optimal cone applicator. With the cone applicator now defined as the entire assembly including the surrounding tungsten-alloy shell holding the HDR {sup 192}Ir source catheter, the applicator height was reduced to diminish the treatment time while minimizing skin dose. Monte Carlo simulation results were validated using both radiochromic film and ionization chamber measurements based on established techniques. Results: The optimal cone applicators diminished the maximum skin dose by 15%-32% (based on the applicator diameter and breast separation) with the tumor dose reduced by less than 3% for a constant exposure time. Furthermore, reduction in applicator height diminished the treatment time by up to 30%. Radiochromic film and ionization chamber dosimetric results in phantom agreed with Monte Carlo simulation results typically within 3%. Larger differences were outside the treatment volume in low dose regions or associated with differences between the measurement and Monte Carlo simulation environments. Conclusions: A new radiotherapy treatment device was developed and dosimetrically characterized. This set of applicators significantly reduces the skin dose and treatment time while retaining uniform target dose.

60 APPLIED LIFE SCIENCES↗