Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Attosecond transient absorption of argon atoms in the vacuum ultraviolet region: line energy shifts versus coherent population transfer

Using attosecond transient absorption, the dipole response of an argon atom in the vacuum ultraviolet (VUV) region is studied when an external electromagnetic field is present. An isolated attosecond VUV pulse populates Rydberg states lying 15 eV above the argon ground state. A synchronized few-cycle near infrared (NIR) pulse modifies the oscillating dipoles of argon impulsively, leading to alterations in the VUV absorption spectra. As the NIR pulse is delayed with respect to the VUV pulse, multiple features in the absorption profile emerge simultaneously including line broadening, sideband structure, sub-cycle fast modulations, and 5-10 fs slow modulations. These features indicate the coexistence of two general processes of the light-matter interaction: the energy shift of individual atomic levels and coherent population transfer between atomic eigenstates, revealing coherent superpositions. Finally, an intuitive formula is derived to treat both effects in a unifying framework, allowing one to identify and quantify the two processes in a single absorption spectrogram.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DISCOVERY OF A LARGE-SCALE GALAXY FILAMENT NEAR A CANDIDATE INTERGALACTIC X-RAY ABSORPTION SYSTEM

We present an analysis of the large-scale galaxy distribution around two possible warm-hot intergalactic medium (WHIM) absorption systems reported along the Markarian 421 sight line. Using the Sloan Digital Sky Survey (SDSS), we find a prominent galaxy filament at the redshift of the z = 0.027 X-ray absorption line system. The filament exhibits a width of 3.2 Mpc and a length of at least 20 Mpc, comparable to the size of WHIM filaments seen in cosmological simulations. No individual galaxies fall within 350 projected kpc so it is unlikely that the absorption is associated with gas in a galaxy halo or outflow. Another, lower-significance X-ray absorption system was reported in the same Chandra spectrum at z = 0.011, but the large-scale structure in its vicinity is far weaker and may be a spurious alignment. By searching for similar galaxy structures in 140 random smoothed SDSS fields, we estimate an {approx}5%-10% probability of the z = 0.027 absorber-filament alignment occurring by chance. If these two systems are indeed physically associated, this would represent the first known coincidence between a large-scale galaxy structure and a blind X-ray WHIM detection.

79 ASTRONOMY AND ASTROPHYSICS↗

THE END OF HELIUM REIONIZATION AT z {approx_equal} 2.7 INFERRED FROM COSMIC VARIANCE IN HST/COS He II Ly{alpha} ABSORPTION SPECTRA

We report on the detection of strongly varying intergalactic He II absorption in HST/COS spectra of two z{sub em} {approx_equal} 3 quasars. From our homogeneous analysis of the He II absorption in these and three archival sightlines, we find a marked increase in the mean He II effective optical depth from <{tau}{sub eff},He{sub ii}>{approx_equal}1 at z {approx_equal} 2.3 to <{tau}{sub eff},He{sub ii}>{approx}>5 at z {approx_equal} 3.2, but with a large scatter of 2{approx}<{tau}{sub eff},He{sub ii}{approx}<5 at 2.7 < z < 3 on scales of {approx}10 proper Mpc. This scatter is primarily due to fluctuations in the He II fraction and the He II-ionizing background, rather than density variations that are probed by the coeval H I forest. Semianalytic models of He II absorption require a strong decrease in the He II-ionizing background to explain the strong increase of the absorption at z {approx}> 2.7, probably indicating He II reionization was incomplete at z{sub reion} {approx}> 2.7. Likewise, recent three-dimensional numerical simulations of He II reionization qualitatively agree with the observed trend only if He II reionization completes at z{sub reion} {approx_equal} 2.7 or even below, as suggested by a large {tau}{sub eff},He{sub ii}{approx}>3 in two of our five sightlines at z < 2.8. By doubling the sample size at 2.7 {approx}< z {approx}< 3, our newly discovered He II sightlines for the first time probe the diversity of the second epoch of reionization when helium became fully ionized.

79 ASTRONOMY AND ASTROPHYSICS↗

VARIABLE REDDENING AND BROAD ABSORPTION LINES IN THE NARROW-LINE SEYFERT 1 GALAXY WPVS 007: AN ORIGIN IN THE TORUS

We report the discovery of an occultation event in the low-luminosity narrow-line Seyfert 1 galaxy WPVS 007 in 2015 February and March. In concert with longer timescale variability, these observations place strong constraints on the nature and location of the absorbing material. Swift monitoring has revealed a secular decrease since ∼2010 accompanied by flattening of the optical and UV photometry that suggests variable reddening. Analysis of four Hubble Space Telescope COS observations since 2010, including a Director’s Discretionary time observation during the occultation, shows that the broad-absorption-line velocity offset and the C iv emission-line width both decrease as the reddening increases. The occultation dynamical timescale, the BAL variability dynamical timescale, and the density of the BAL gas show that both the reddening material and the broad-absorption-line gas are consistent with an origin in the torus. These observations can be explained by a scenario in which the torus is clumpy with variable scale height, and the BAL gas is blown from the torus material like spray from the crest of a wave. As the obscuring material passes into our line of sight, we alternately see high-velocity broad absorption lines and a clear view to the central engine, or low-velocity broad absorption lines and strong reddening. WPVS 007 has a small black hole mass, and correspondingly short timescales, and so we may be observing behavior that is common in BALQSOs, but is not typically observable.

79 ASTRONOMY AND ASTROPHYSICS↗

Coherent control of two-photon transitions in a two-level system with broadband absorption

Multiphoton transition probability can be manipulated by tailoring the ultrashort laser pulses. In this paper, we theoretically and experimentally investigate the influence of the absorption bandwidth and line shape on the coherent control of two-photon transitions in two-level system by manipulating the femtosecond laser pulse with the {pi} spectral phase step. A coherent feature with a coherent peak and two coherent dips can be achieved if the absorption bandwidth is less than twice of the laser spectral bandwidth. The absorption bandwidth decides the coherent peak or dip intensity, and the absorption line shape affects the symmetry of the two coherent dips.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rapidly reconfigurable slow-light system based on off-resonant Raman absorption

We present a slow-light system based on dual Raman absorption resonances in warm rubidium vapor. Each Raman absorption resonance is produced by a control beam in an off-resonant {Lambda} system. This system combines all optical control of the Raman absorption and the low-dispersion broadening properties of the double Lorentzian absorption slow light. The bandwidth, group delay, and central frequency of the slow-light system can all be tuned dynamically by changing the properties of the control beam. We demonstrate multiple pulse delays with low distortion and show that such a system has fast switching dynamics and thus fast reconfiguration rates.

74 ATOMIC AND MOLECULAR PHYSICS↗

Transient absorption and reshaping of ultrafast XUV light by laser-dressed helium

We present a theoretical study of transient absorption and reshaping of extreme ultraviolet (XUV) pulses by helium atoms dressed with a moderately strong infrared (IR) laser field. We formulate the atomic response using both the frequency-dependent absorption cross section and a time-frequency approach based on the time-dependent dipole induced by the light fields. The latter approach can be used in cases when an ultrafast dressing pulse induces transient effects, and/or when the atom exchanges energy with multiple frequency components of the XUV field. We first characterize the dressed atom response by calculating the frequency-dependent absorption cross section for XUV energies between 20 and 24 eV for several dressing wavelengths between 400 and 2000 nm and intensities up to 10{sup 12} W/cm{sup 2}. We find that for dressing wavelengths near 1600 nm, there is an Autler-Townes splitting of the 1s{yields}2p transition that can potentially lead to transparency for absorption of XUV light tuned to this transition. We study the effect of this XUV transparency in a macroscopic helium gas by incorporating the time-frequency approach into a solution of the coupled Maxwell-Schroedinger equations. We find rich temporal reshaping dynamics when a 61-fs XUV pulse resonant with the 1s{yields}2p transition propagates through a helium gas dressed by an 11-fs, 1600-nm laser pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromagnetically induced absorption via incoherent collisions

We conduct theoretical studies on electromagnetically induced absorption via incoherent collisions in an inhomogeneously broadened ladder-type three-level system with the density-matrix approach. The effects of the collision-induced coherence decay rates as well as the probe laser field intensity on the probe field absorption are examined. It is shown that with the increase of the collisional decay rates in a moderate range, a narrow dip due to electromagnetically induced transparency superimposed on the Doppler-broadened absorption background can be turned into a narrow peak under the conditions that the probe field intensity is not very weak as compared to the pump field, which results from the enhancement of constructive interference and suppression of destructive interference between one-photon and multiphoton transition pathways. The physical origin of the collision-assisted electromagnetically induced absorption is analyzed with a power-series solution of the density-matrix equations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Probing autoionizing states of molecular oxygen with XUV transient absorption: Electronic-symmetry-dependent line shapes and laser-induced modifications

In this paper, we used extreme ultraviolet (XUV) transient absorption spectroscopy to study the autoionizing Rydberg states of oxygen in an electronically- and vibrationally-resolved fashion. XUV pulse initiates molecular polarization and near-infrared pulse perturbs its evolution. Transient absorption spectra show positive optical-density (OD) change in the case of $ns{{\sigma}}_{g}$ and $nd{{\pi}}_{g}$ autoionizing states of oxygen and negative OD change for $nd{{\sigma}}_{g}$ states. Multiconfiguration time-dependent Hartree-Fock (MCTDHF) calculations are used to simulate the transient absorption and the resulting spectra and temporal evolution agree with experimental observations. We model the effect of near-infrared perturbation on molecular polarization and find that the laser-induced phase-shift model agrees with the experimental and MCTDHF results, while the laser-induced attenuation model does not. Finally, we relate the electronic-state-symmetry-dependent sign of the OD change to the Fano parameters of the static absorption line shapes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Vibrational response and temperature of shock-compressed Pt: In situ extended x-ray absorption fine structure measurements to 325 GPa

Single pulse (~100 ps duration) extended x-ray absorption fine structure (EXAFS) measurements were obtained in laser shocked Pt to examine atomic vibrational properties and to determine temperatures for shock pressures from 72-325 GPa. Pt x-ray absorption spectra were recorded while a planar shock wave was propagating through the Pt sample. The absorption spectrum corresponding to the shocked Pt was obtained by subtracting the ambient Pt contribution from the measured absorption spectrum. Fits to the shocked state EXAFS data provided Pt lattice parameters consistent with the known Pt Hugoniot and the mean squared relative displacements (MSRDs) for nearest neighbor Pt atoms. Pt temperatures in the shocked state, estimated from the MSRDs using the correlated Debye model and correlated Einstein models, were consistent with both the Hugoniot temperatures calculated by integration along the Hugoniot and with the Hugoniot temperatures from published first-principles calculations. However, the agreement between the Hugoniot temperatures from EXAFS measurements and the calculated Hugoniot temperatures is not as good above 200 GPa, likely due to anharmonic effects. Furthermore, the present results demonstrate that single-pulse synchrotron EXAFS measurements in laser-shocked solids are useful for quantitative temperature determination and for examination of vibrational properties, including anharmonicity, at extreme pressure-temperature conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distance redshift from an optical metric that includes absorption

We show that it is possible to equate the intensity reduction of a light wave caused by weak absorption with a geometrical reduction in intensity caused by a 'transverse' conformal transformation of the spacetime metric in which the wave travels. We are consequently able to modify Gordon's optical metric to account for electromagnetic properties of ponderable material whose properties include both refraction and absorption. Unlike refraction alone, however, including absorption requires a modification of the optical metric that depends on the eikonal of the wave itself. We derive the distance-redshift relation from the modified optical metric for Friedman-Lemaitre-Robertson-Walker spacetimes whose cosmic fluid has associated refraction and absorption coefficients. We then fit the current supernovae data and provide an alternate explanation (other than dark energy) of the apparent acceleration of the Universe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Redshifted intergalactic {sup 3}He{sup +} 8.7 GHz hyperfine absorption

Motivated by recent interest in redshifted 21 cm emission of intergalactic hydrogen, we investigate the 8.7 GHz {sup 2}S{sub 1/2} F=0-1 hyperfine transition of {sup 3}He{sup +}. While the primordial abundance of {sup 3}He relative to hydrogen is 10{sup -5}, the hyperfine spontaneous decay rate is 680 times larger. Furthermore, the antenna temperature is much lower at the frequencies relevant for the {sup 3}He{sup +} transition compared to that of z>6 21 cm emission. We find that the spin temperature of this 8.7 GHz line in the intergalactic medium is approximately the cosmic microwave background temperature, such that this transition is best observed in absorption against high-redshift, radio-bright quasars. We show that intergalactic 8.7 GHz absorption is a promising, unsaturated observable of the ionization history of intergalactic helium (for which He II{yields}He III reionization is believed to complete at z{approx}3) and of the primordial {sup 3}He abundance. Instruments must reach {approx}1 {mu}Jy RMS noise in bands of 1 MHz on a 1 Jy source to directly resolve this absorption. However, in combination with H i Ly{alpha} forest measurements, an instrument can statistically detect this absorption from z>3 with 30 {mu}Jy RMS noise in 0.1 MHz spectral bands over 100 MHz, which may be within the reach of present instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Inverse Bremsstrahlung Absorption

Inverse bremsstrahlung absorption was measured based on transmission through a finite-length plasma that was thoroughly characterized using spatially resolved Thomson scattering. Expected absorption was then calculated using the diagnosed plasma conditions while varying the absorption model components. To match data, it is necessary to account for: (1) the Langdon effect; (2) laser-frequency (rather than plasma-frequency) dependence in the Coulomb logarithm, as is typical of bremsstrahlung theories but not transport theories; and (3) a correction due to ion screening. Radiation-hydrodynamic simulations of inertial confinement fusion implosions have to date used a Coulomb logarithm from the transport literature and no screening correction. Here, we anticipate that updating the model for collisional absorption will substantially revise our understanding of laser-target coupling for such implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

TU-A-9A-07: X-Ray Acoustic Computed Tomography (XACT): 100% Sensitivity to X-Ray Absorption

Purpose: To assess whether X-ray acoustic computed tomography (XACT) is more sensitive to X-ray absorption than that of the conventional X-ray imaging. Methods: First, a theoretical model was built to analyze the X-ray absorption sensitivity of XACT imaging and conventional X-ray imaging. Second, an XACT imaging system was developed to evaluate the X-ray induced acoustic signal generation as well as the sensitivity improvement over transmission x-ray imaging. Ultra-short x-ray pulses (60-nanosecond) were generated from an X-ray source operated at the energy of 150 kVp with a 10-Hz repetition rate. The X-ray pulse was synchronized with the acoustic detection via a x-ray scintillation triggering to acquire the X-ray induced acoustic signal. Results: Theoretical analysis shows that X-ray induced acoustic signal is sensitive only to the X-ray absorption, while completely insensitive to out the X-ray scattering and fluorescence. XACT has reduced background and increased contrast-to-noise ratio, and therefore has increased sensitivity compared to transmission x-ray imaging. For a 50-μm size, gadolinium insertion in tissue exposed to 40 keV X-rays; the sensitivity of XACT imaging is about 28.9 times higher than that of conventional X-ray imaging. Conclusion: X-ray acoustic computer tomography (XACT) as a new imaging modality combines X-ray absorption contrast and high ultrasonic resolution in a single modality. It is feasible to improve the imaging sensitivity with XACT imaging compared with conventional X-ray imaging. Taking advantage of the high ultrasonic resolution, it is possible to perform 3-D imaging with a single x-ray pulse with arrays of transducers without any mechanical motion of the imaging system. This single-shot capability offers the potential of reducing radiation dose by a factor of 1000, and imaging 100 times faster when compared to the conventional X-ray CT, and thus revolutionizing x-ray imaging applications in medicine and biology. The authors gratefully acknowledge the Department of Defense Prostate Cancer Research Programs W81XWH-13-1-0481 (LX), the National Institutes of Health 1R01 CA133474 and 1R21 A153587, and SRFDP (20124407120012) for funding.

60 APPLIED LIFE SCIENCES↗

CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and phantom axis but were insensitive to tube voltage. H(L) was insensitive to tube voltage and CT scanner model. As phantom diameter increased from 6 to 55 cm, E{sub in}/E generally decreased but asymptotically approached constant levels on the peripheral axes of large phantoms. The curve of E{sub in}/E versus scan length was almost identical to that of H(L). Similarly, E{sub out}/E increased with scan length and asymptotically approached the equilibrium for large scan lengths. E{sub out}/D{sub eq} was much less than the equilibrium length L{sub eq} where H(L) = 0.98, even with scan lengths much larger than L{sub eq}. Conclusions: The polyethylene phantom designed by ICRU Report No. 87 Committee and AAPM Task Group 200 is adequately long for assessing the midpoint dose and its equilibration in CT scanning. The short-to-long phantom dose ratios and the H(L) data provided in this paper allow easy evaluations of the midpoint dose, longitudinal dose distribution, and energy absorption in polyethylene phantoms. The results of dose equilibration and energy absorption presented herein may be insightful for the clinical CT scans with various subject sizes and scan lengths.

07 ISOTOPE AND RADIATION SOURCES↗

Dependence of the Two-Photon Absorption Coefficient of Steel on the Pulse Duration During Its Ablation by Femto- and Picosecond Laser Pulses

The dependences of the depth of single-pulse ablation of the steel surface on the energy density of ultrashort laser pulses (0.3–12 ps) with a wavelength of 515 nm have the form different from the usual logarithmic one for linear absorption of radiation. Since the density of states of free conduction electrons in the s band is low, and the d band of strongly bound electrons with a high density of states is located around the Fermi level, these dependences have been approximated within the two-photon absorption model. The two-photon absorption coefficient increases almost linearly with the duration of laser pulses, which indicates the saturation of absorption and allows estimating the corresponding parameters of the electronic subsystem. © 2019, Pleiades Publishing, Inc.

60 APPLIED LIFE SCIENCES↗

The Effect of an Antirelaxation Coating on Absorption in the D{sub 2} Lines of Alkali Metals

The specific features of absorption in a cell with an antirelaxation coating related to optical pumping and a finite rate of laser-frequency scanning are studied. The internal state of an atom in such cells is likely to remain unaltered after a collision with a wall. This results in optical pumping of an atomic ensemble over all velocities and the entire cell volume. Both the frequency corresponding to the maximum absorption in the D{sub 2} line of {sup 133}Cs and the absorption maximum itself depend on the sign of laser-frequency scanning. A theoretical model attributing the power dependence of asymmetry of the absorption contour of the {sup 133}Cs D{sub 2} line to the presence of cyclic transition levels in the system is presented.

74 ATOMIC AND MOLECULAR PHYSICS↗