Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Virtual Flight through a Catalyst Particle

This visualization of the experimental data shows how scientists mapped the distribution of chemical elements in a single fluid catalytic cracking (FCC) particle and merged it with structural information about the pore networks. Because of the high resolution at which they mapped the catalyst, they were able to look deep into the pores and learn more about the metal poisoning reaction. The changing colors of the "fog" inside the pores reflect the changing chemistry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Intelligent Process Visualization through Nuclear Operation Process Modeling, Reasoning, and Object Detection from Field Videos (Final Report)

This report is a deliverable for the “Final Report” task of DOE NEET Project 19-16790, "Context-Aware Safety Information Display for Nuclear Field Workers." This project's overall goal is to test the hypothesis that integrating computer vision and process reasoning methods will enable proactive visualization of the safe operation and maintenance processes of Nuclear Power Plants (NPP) for field workers. Augmented Reality (AR) glasses adopting such proactive safety information visualization techniques can significantly increase personnel safety and reduce the NPP’s operating costs. The current practice of monitoring NPPs requires workers to switch between digital models, data, and physical workspaces in identifying relevant but potentially occluded objects and in assessing the risks of operation and maintenance processes. On the other hand, frequently changed field conditions require field workers to report to supervisors for real-time guidance. Such guidance is essential to ensure that changing conditions will not invalidate or endanger the work order and other ongoing processes that may jeopardize NPP operations. Additionally, incorrect recognition of equipment objects can result in communication errors and safety problems. AR techniques can assist engineers in viewing the physical workspaces with objects labeled with detailed operation procedures and safety reminders during field operations. The project team developed an “Intelligent Context-Aware Safety Information Display” (ICAD) for supporting Nuclear Power Plant (NPP) field workers in achieving safe and efficient execution of a series of operational tasks in uncertain and changing workspaces of an NPP. Before designing the ICAD-AR prototype, the project team synthesized NPP operational knowledge models through literature review studies, surveys, interviews with domain experts, and knowledge modeling. The project team conducted an extensive study of the operational procedures of various NPPs, and digital technologies that can support the safe and efficient execution of those procedures in different NPP operational contexts. This literature review helped the project team conduct surveys and interviews with nuclear engineers and field workers to identify three categories of information. The NPP knowledge modeling efforts reveal that the three categories of information identified have different levels of importance in a typical procedure of carrying out a series of tasks to achieve a specific NPP operation goal (e.g., shutdown, mode changes). These three categories of information include 1) Workspace dynamics – the changing spatial arrangements of workspaces, tools, protection equipment, and supporting materials, 2) Workflow prognostics – the dynamic dependencies between different parts of an NPP that functionally support and influence each other in terms of safety and efficiency, and 3) Hazards – objects and spaces that contain hazardous materials or physical conditions that can pose risks to workers or mechanical systems. The project team has profiled the importance levels of these categories of information into a knowledge model. This knowledge model specifies what types of information are more critical for a given task in a given workspace so that computers can automatically identify critical objects and sensors in a scene for delivering context-ware safety information to field workers through AR devices. Significant research development of this project results in technical research outcomes and a prototyping system that illustrates the technical feasibility of establishing an ICAD-AR system supporting the proactive safety information display for nuclear field workers. This final report summarizes the project team’s technological achievements in the past three years. Overall, the project team completed the development and integration of five techniques into a prototype ICAD Augmented Reality (ICAD-AR) system and demonstrated the developed system’s real-time execution in a mechanical room. The project team completed the analysis of using this prototype in other types of workspaces based on 3D image data and digital design models collected from two additional workspaces (a water treatment plant and a flow loop training facility). The integrated techniques include 1) Natural Language Processing (NLP) algorithms supporting the generation and updates of nuclear fieldwork process models based on text analysis of work packages and operation manuals; 2) sensor log analysis for predicting control actions in given sensor reading contexts; 3) computer vision algorithms for automatic localization and navigation of workers; 4) object detection algorithms for identifying task-related objects and correlated sensors for safety checking; 5) AR technique as a platform for supporting the integration. The testing results of these five techniques have shown that 1) the sensor log analysis model can predict the next control action with an accuracy of 0.883; 2) the trained natural language processing model can extract more than 80% of the critical information from paper-based procedures (PBPs); 3) the navigation algorithm with the integration of Visual Inertial Odometry (VIO) and Non-Recursive Bayesian Filter methods make operator’s trajectory estimation resilient to drift error; 4) the computer vision algorithm can detect task-specific and safety-critical objects with an average accuracy of 95.3%. The project team used work procedures collected from a flow loop training facility and two datasets collected from two mechanical rooms simulating the workspaces of NPPs to demonstrate the technical capabilities of the developed ICAD-AR prototype. The demonstration validated the technical feasibility of establishing the ICAD-AR system for nuclear field workers and identified the challenges in 1) automatic text analysis of work packages; 2) use of limited samples of sensor logs for predicting the proper timings of control actions; 3) reliably tracking workers and their task progress in mechanical rooms with many similar objects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-J-203: Reconstruction of the Treatment Area by Use of Sinogram in Helical Tomotherapy

Purpose: TomoTherapy (Accuray Co.) has an image-guided radiotherapy system with megavoltage (MV) X-ray source and the on-board imaging device. With the MV computed tomography (MVCT), it became feasible to perform the efficient daily-3D registration of the patient position before each treatment delivery. This system also allows one to acquire the delivery sinogram during the actual treatment, which partly includes the information of the irradiated object. In this study, we try to develop the image reconstruction during treatment in helical Tomotherapy. Methods: Sinogram data were acquired during helical Tomotherapy delivery using an arc-shaped detector array that consists of 738 xenon-gas filled detector cells. In preprocessing, these were normalized by full air-scan data. A software program was developed that reconstructs 3D images during treatment with corrections as; (1) the regions outside the field were masked not to be added in the backprojection (a masking correction), and (2) each voxel of the reconstructed image was divided by the number of the X-ray passing through its voxel (a ray-passing correction). Results: Without masking and ray-passing corrections, the image reconstruction was failed. The masking correction made the image clear, however, the streak artifact was accompanied. The ray-passing correction reduced this artifact. Although the SNR (the ratio of mean to standard deviation in homogeneous region) and the contrast of the reconstructed image were slightly improved with the ray-passing correction, the masking correction only is enough for the visualization purpose. Conclusion: The visualization of the treatment area was feasible by use of the sinogram in helical Tomotherapy. This proposed method can be utilized in the treatment verification. This work was partly supported by JSPS KAKENHI 24234567. No COI, but the data in this paper were prepared by collaborators in Accuray.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PROTEUS-MOC User Manual

The PROTEUS-MOC code is a three-dimensional (3D) neutron transport code based on the finite element mesh and the method of characteristics (MOC) which combines a 2D MOC with the discontinuous Galerkin finite element method for the axial direction. Thus, for PROTEUS-MOC, a 3D geometry is represented with by the implicit extrusion of a single 2D planar geometry with different material assignments allowable on each plane. The code requires four input files for a steady-state calculation without the thermal feedback: a driver input, a mesh input, a cross section input, and a material assignment input. With thermal feedback, a T/H input file is needed. For kinetics, a kinetics driver input file is required. The PROTEUS-MOC software produces a text output file as well as a data file which includes integral and average quantities such on fluxes, powers, temperatures, densities, etc. The detailed output file can be converted to the VTK format using the post processing code so that the outputs can be visualized using a visualization software such as VisIt.

97 MATHEMATICS AND COMPUTING↗

Extending a CAD-Based Cartesian Mesh Generator for the Lattice Boltzmann Method

This paper describes the development of a custom preprocessor for the PaRAllel Thermal Hydraulics simulations using Advanced Mesoscopic methods (PRATHAM) code based on an open-source mesh generator, CartGen [1]. PRATHAM is a three-dimensional (3D) lattice Boltzmann method (LBM) based parallel flow simulation software currently under development at the Oak Ridge National Laboratory. The LBM algorithm in PRATHAM requires a uniform, coordinate system-aligned, non-body-fitted structured mesh for its computational domain. CartGen [1], which is a GNU-licensed open source code, already comes with some of the above needed functionalities. However, it needs to be further extended to fully support the LBM specific preprocessing requirements. Therefore, CartGen is being modified to (i) be compiler independent while converting a neutral-format STL (Stereolithography) CAD geometry to a uniform structured Cartesian mesh, (ii) provide a mechanism for PRATHAM to import the mesh and identify the fluid/solid domains, and (iii) provide a mechanism to visually identify and tag the domain boundaries on which to apply different boundary conditions.

Cartesian Grid↗

Influence of Contrast Agent Dilution on Ballon Deflation Time and Visibility During Tracheal Balloon Dilation: A 3D Printed Phantom Study

PurposeTo determine the effect of contrast medium dilution during tracheal balloon dilation on balloon deflation time and visibility using a 3-dimensional (3D) printed airway phantom.Materials and MethodsA comparison study to investigate balloon deflation times and image quality was performed using two contrast agents with different viscosities, i.e., iohexol and ioxithalamate, and six contrast dilutions with a 3D printed airway phantom.ResultsCompared to 1:0 concentration, 3:1, 2:1, 1:1, 1:2, and 1:3, contrast/saline ratios resulted in a 46% (56.2 s), 59.8% (73.1 s), 74.9% (91.6 s), 81.7% (99.8 s), and 83.5% (102 s) reduction for iohexol, respectively, and a 51.8% (54.7 s), 63.8% (67.6 s), 74.7% (79.2 s), 80.5% (85.3 s), and 82.4% (87.4 s) reduction for ioxithalamate, respectively, in the mean balloon deflation time, although at the expense of decreased balloon opacity (3.5, 6.9, 11.1, 12.4, and 13.9%, for iohexol, respectively, and 3.2, 6, 9.6, 10.8, and 12.4%, for ioxithalamate, respectively).ConclusionsUse of a lower viscosity contrast agent and higher contrast dilution is considered to be able to reduce balloon deflation times and then simultaneously decrease visualization of balloons. The rapid balloon deflation time is likely to improve the safe performance of interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FLARE: field line analysis and reconstruction for 3D boundary plasma modeling

The FLARE code is a magnetic mesh generator that is integrated within a suite of tools for the analysis of the magnetic geometry in toroidal fusion devices. A magnetic mesh is constructed from field line segments and permits fast reconstruction of field lines in 3D boundary plasma codes such as EMC3-EIRENE. Both intrinsically non-axisymmetric configurations (stellarators) and those with symmetry breaking perturbations of an axisymmetric equilibrium (tokamaks) are supported. The code itself is written in Modern Fortran with MPI support for parallel computing, and it incorporates object-oriented programming for the definition of the magnetic field and the material surface geometry. Extended derived types for a number of different magnetohydrodynamic equilibrium and plasma response models are implemented. The core element of FLARE is a field line tracer with adaptive step-size control, and this is integrated into tools for the construction of Poincaré maps and invariant manifolds of X-points. A collection of high-level procedures that generate output files for visualization is build on top of that. The analysis modules are build with Python frontends that facilitate customization of tasks and/or scripting of parameter scans.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images were in general agreement with real human images. The Singlet approach offered more realistic contrast as compared to the Doublet approach, but at the expense of air bubbles and air pockets that formed during the filling process. Conclusions: The presented physical breast phantoms and their matching virtual breast phantoms offer realistic breast anatomy, patient variability, and ease of use, making them a potential candidate for performing both system quality control testing and virtual clinical trials.

60 APPLIED LIFE SCIENCES↗

Visualization and prediction of supercritical CO 2 distribution in sandstones during drainage: An in situ synchrotron X-ray micro-computed tomography study

Pore-scale distribution of supercritical CO 2 (scCO 2 ) exerts significant control on a variety of key hydrologic as well as geochemical processes, including residual trapping and dissolution. Despite such importance, only a small number of experiments have directly characterized the three-dimensional distribution of scCO 2 in geologic materials during the invasion (drainage) process. Here, we present a study which couples dynamic high-resolution synchrotron X-ray micro-computed tomography imaging of a scCO 2 /brine system at in situ pressure/temperature conditions with quantitative pore-scale modeling to allow direct validation of a pore-scale description of scCO2 distribution. The experiment combines high-speed synchrotron radiography with tomography to characterize the brine saturated sample, the scCO 2 breakthrough process, and the partially saturated state of a sandstone sample from the Domengine Formation, a regionally extensive unit within the Sacramento Basin (California, USA). The availability of a 3D dataset allowed us to examine correlations between grains and pores morphometric parameters and the actual distribution of scCO 2 in the sample, including the examination of the role of small-scale sedimentary structure on CO2 distribution. The segmented scCO 2 /brine volume was also used to validate a simple computational model based on the local thickness concept, able to accurately simulate the distribution of scCO 2 after drainage. The same method was also used to simulate Hg capillary pressure curves with satisfactory results when compared to the measured ones. Finally, this predictive approach, requiring only a tomographic scan of the dry sample, proved to be an effective route for studying processes related to CO 2 invasion structure in geological samples at the pore scale.

3D quantitative morphometric analysis↗

Development of an accelerator-based neutron source to prototype Mo-99 production, part I: A liquid LBE windowless target

In this article, Molybdenum-99 (Mo-99)’s decay product, technetium-99 (Tc-99 m), is one of the most critical isotopes for medical diagnostics. To provide U.S. domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. This study discusses the development of the accelerator-based neutron source. The high-energy electrons from the accelerator irradiate a liquid lead-bismuth eutectic (LBE) target to produce neutrons. Part I of this work focuses on numerical and experimental analysis towards the development of a liquid LBE windowless target. Unlike the existing windowless targets in literature, the current design creates a vertical free surface for a beam to irradiate. First, a hydrodynamic analysis of the LBE windowless target is performed. Simplified analytical calculations are assisted by 2D computational fluid dynamics (CFD) simulations to design the target, with the focus on eliminating recirculation zones and avoiding cavitation. With the optimized geometry, the experimental study is performed to investigate the flow hydrodynamics using liquid LBE. The experiments (1) compare pressure drop in the system to correlation predictions; (2) visualize the free surface liquid LBE flow from the beam view; (3) validate the LBE flow profile using temperature sensitive paint from the side view; and (4) validate the liquid LBE film thickness using gamma densitometer measurements. Second, the power handling capability of the designed windowless target is investigated. The divider plate in the current design is susceptible to overheating due to the thin LBE film in front. As LBE erosion and corrosion is likely to occur at an LBE velocity of 2.0 m/s and temperature above 500 °C, a power limit of 10 kW of beam power was established to prevent this corrosion from occurring, which is calculated by a Nusselt number correlation. The divider plate surface temperature at 10 kW agrees well with the 3D CFD simulation results. Part I demonstrates the fundamental physics in liquid LBE windowless target design and associated testing. A companion paper, Part II will demonstrate how to couple this windowless target into the Mo-99 production system, including an accelerator system operating under an ultra-high vacuum and the UTA cooled by water at room temperature.

43 PARTICLE ACCELERATORS↗

Deep-learning-based workflow for boundary and small target segmentation in digital rock images using UNet++ and IK-EBM

We report three-dimensional (3D) X-ray micro-computed tomography (μCT) has been widely used in petroleum engineering because it can provide detailed pore structural information for a reservoir rock, which can be imported into a pore-scale numerical model to simulate the transport and distribution of multiple fluids in the pore space. The partial volume blurring (PVB) problem is a major challenge in segmenting raw μCT images of rock samples, which impacts boundaries and small targets near the resolution limit. We developed a deep-learning (DL)-based workflow for accurate and fast partial volume segmentation. The DL model's performance depends primarily on the training data quality and model architecture. This study employed the entropy-based-masking indicator kriging (IK-EBM) to segment 3D Berea sandstone images as training datasets. The comparison between IK-EBM and manual segmentation using a 3D synthetic sphere pack, which had a known ground truth, showed that IK-EBM had higher accuracy on partial volume segmentation. We then trained and tested the UNet++ model, a state-of-the-art supervised encoder-decoder model, for binary (i.e., void and solid) and four-class segmentation. We compared the UNet++ with the commonly used U-Net and wide U-Net models and showed that the UNet++ had the best performance in terms of pixel-wise and physics-based evaluation metrics. Specifically, boundary-scaled accuracy demonstrated that the UNet++ architecture outperformed the regular U-Net architecture in the segmentation of pixels near boundaries and small targets, which were subjected to the PVB effect. Feature map visualization illustrated that the UNet++ bridged the semantic gaps between the feature maps extracted at different depths of the network, thereby enabling faster convergence and more accurate extraction of fine-scale features. The developed workflow significantly enhances the performance of supervised encoder-decoder models in partial volume segmentation, which has extensive applications in fundamental studies of subsurface energy, water, and environmental systems.

02 PETROLEUM↗

Role of Valine 464 in the Flavin Oxidation Reaction Catalyzed by Choline Oxidase

The oxidation of reduced flavin cofactors by oxygen is a very important reaction that is central to the chemical versatility of hundreds of flavoproteins classified as monooxygenases and oxidases. These enzymes are characterized by bimolecular rate constants {ge} 10{sup 5} M{sup -1} s{sup -1} and produce water and hydrogen peroxide, respectively. A hydrophobic cavity close to the reactive flavin C(4a) atom has been previously identified in the 3D structure of monooxygenases but not in flavoprotein oxidases. In the present study, we have investigated by X-ray crystallography, mutagenesis, steady-state, and rapid reaction approaches the role of Val464, which is <6 {angstrom} from the flavin C(4a) atom in choline oxidase. The 3D structure of the Val464Ala enzyme was essentially identical to that of the wild-type enzyme as shown by X-ray crystallography. Time-resolved anaerobic substrate reduction of the enzymes showed that replacement of Val464 with alanine or threonine did not affect the reductive half-reaction. Steady-state and rapid kinetics as well as enzyme-monitored turnovers indicated that the oxidative half-reaction in the Ala464 and Thr464 enzymes was decreased by 50-fold with respect to the wild-type enzyme. We propose that the side chain of Val464 in choline oxidase provides a nonpolar site that is required to guide oxygen in proximity of the C(4a) atom of the flavin, where it will subsequently react via electrostatic catalysis. Visual analysis of available structures suggests that analogous nonpolar sites are likely present in most flavoprotein oxidases. Mechanistic considerations provide rationalization for the differences between sites in monooxygenases and oxidases.

59 BASIC BIOLOGICAL SCIENCES↗

Critical point cancellation in 3D vector fields: Robustness and discussion

Vector field topology has been successfully applied to represent the structure of steady vector fields. Critical points, one of the essential components of vector field topology, play an important role in describing the complexity of the extracted structure. Simplifying vector fields via critical point cancellation has practical merit for interpreting the behaviors of complex vector fields such as turbulence. However, there is no effective technique that allows direct cancellation of critical points in 3D. This work fills this gap and introduces the first framework to directly cancel pairs or groups of 3D critical points in a hierarchical manner with a guaranteed minimum amount of perturbation based on their robustness, a quantitative measure of their stability. In addition, our framework does not require the extraction of the entire 3D topology, which contains non-trivial separation structures, and thus is computationally effective. Furthermore, our algorithm can remove critical points in any subregion of the domain whose degree is zero and handle complex boundary configurations, making it capable of addressing challenging scenarios that may not be resolved otherwise. Here, we apply our method to synthetic and simulation datasets to demonstrate its effectiveness.

97 MATHEMATICS AND COMPUTING↗

MO-F-CAMPUS-J-05: Toward MRI-Only Radiotherapy: Novel Tissue Segmentation and Pseudo-CT Generation Techniques Based On T1 MRI Sequences

Purpose: To develop and validate a 4 class tissue segmentation approach (air cavities, background, bone and soft-tissue) on T1 -weighted brain MRI and to create a pseudo-CT for MRI-only radiation therapy verification. Methods: Contrast-enhanced T1-weighted fast-spin-echo sequences (TR = 756ms, TE= 7.152ms), acquired on a 1.5T GE MRI-Simulator, are used.MRIs are firstly pre-processed to correct for non uniformity using the non parametric, non uniformity intensity normalization algorithm. Subsequently, a logarithmic inverse scaling log(1/image) is applied, prior to segmentation, to better differentiate bone and air from soft-tissues. Finally, the following method is enrolled to classify intensities into air cavities, background, bone and soft-tissue:Thresholded region growing with seed points in image corners is applied to get a mask of Air+Bone+Background. The background is, afterward, separated by the scan-line filling algorithm. The air mask is extracted by morphological opening followed by a post-processing based on knowledge about air regions geometry. The remaining rough bone pre-segmentation is refined by applying 3D geodesic active contours; bone segmentation evolves by the sum of internal forces from contour geometry and external force derived from image gradient magnitude.Pseudo-CT is obtained by assigning −1000HU to air and background voxels, performing linear mapping of soft-tissue MR intensities in [-400HU, 200HU] and inverse linear mapping of bone MR intensities in [200HU, 1000HU]. Results: Three brain patients having registered MRI and CT are used for validation. CT intensities classification into 4 classes is performed by thresholding. Dice and misclassification errors are quantified. Correct classifications for soft-tissue, bone, and air are respectively 89.67%, 77.8%, and 64.5%. Dice indices are acceptable for bone (0.74) and soft-tissue (0.91) but low for air regions (0.48). Pseudo-CT produces DRRs with acceptable clinical visual agreement to CT-based DRR. Conclusion: The proposed approach makes it possible to use T1-weighted MRI to generate accurate pseudo-CT from 4-class segmentation.

60 APPLIED LIFE SCIENCES↗

Furthering Precision in Sentinel Node Navigational Surgery for Oral Cancer: a Novel Triple Targeting System

To describe an innovative sentinel lymph node (SLN) guidance approach using a radionuclide tracer, 3D augmented reality-guided imaging, and near infrared (NIR) fluorescence over-lay imaging with hand-held probes to optimize accuracy, efficiency, and precise navigation for sentinel node (SN) localization in head and neck cancer. In a cT1N0M0 squamous cell carcinoma of the tongue, pre-operative radionuclide lymphoscintigraphy was performed with a sentinel node-specific radiolabeled tracer. Intraoperatively, a 3D hand-held augmented reality (AR) scanning SPECT probe assessed concordance of the SN with pre-operative SPECT-CT images. The real-time optical video was linked to the SPECT-CT images for added precision. Final guidance to the SN was performed using ICG fluorescence imaging. Dynamic and SPECT-CT showed bilateral lymphatic drainage from the tumor. The 3D hand-held AR SPECT probe SN localization was concordant with pre-operative imaging. The optical video successfully demonstrated the lymphatic drainage in real-time through a unique overlay fluorescence image. The ICG localized to the same nodes identified by both the SPECT-CT and hand-held SPECT images. The use of dual radiation and fluorescence tracers improved SN detection, especially for SN close to the injection site. The hand-held probes allowed the surgeon to dissect continuously, without needing to change tools. The combination of augmented reality, nuclear medicine, and over-lay fluorescence imaging allowed greater accuracy for matching the preoperative imaging with intraoperative identification and precisely guiding the dissection. This method uniquely permitted the surgeon to efficiently dissect the SN with accurate visualization and optimal precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimode turbulent flow measurements using magnetic resonance imaging- and laser-based techniques and computational fluid dynamics simulations

We studied the flow field characteristics of a turbulent flow over a regularized cube array with a perpendicular injection flow through the floor between the second and third cubical elements, representing the complex flow interactions of a 3D jet and the wake flows behind cubical obstacles. Four different experimental measurements were performed: two magnetic resonance imaging-based measurements for three-dimensional three-component velocity (MRV) and concentration (MRC) and two laser-based techniques, particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF), for two-dimensional two-component velocity and concentration measurement, respectively. The mainstream Reynolds number is Re = 15 000⁠, based on the primary inlet velocity U m and channel height D H ⁠, whereas the injector Reynolds number is Re j = 3400⁠, based on the injector velocity U j and the injector's exit width D j ⁠. Numerical simulations were performed for the studied flow configuration of turbulent flow over a regularized cube array using Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulation (LES) approaches. Results obtained from experimental measurements—including MRV, MRC, PIV, and PLIF—as well as RANS and LES simulations are discussed and compared along several horizontal and vertical planes of the studied configuration. In addition, 3D turbulent flow structures, such as leading-edge vortex, horseshoe vortex, and jet shear-layer vortex, and the isosurfaces of scalar concentration successfully revealed by MRV and MRC techniques were found to be in very good agreement with those 3D features extracted from RANS and LES simulations. In conclusion, the high-resolution experimental and numerical database obtained from this study could be useful for validation and verification of numerical codes.

Computational fluid dynamics↗

Micro-CT scouting for transmission electron microscopy of human tissue specimens

Transmission electron microscopy (TEM) provides sub-nanometre-scale details in volumetric samples. Samples such as pathology tissue specimens are often stained with a metal element to enhance contrast, which makes them opaque to optical microscopes. As a result, it can be a lengthy procedure to find the region of interest inside a sample through sectioning. Here, we describe micro-CT scouting for TEM that allows noninvasive identification of regions of interest within a block sample to guide the sectioning step. In a tissue pathology study, a bench-top micro-CT scanner with 10 m resolution was used to determine the location of patches of the mucous membrane in osmium-stained human nasal scraping samples. Furthermore, once the regions of interest were located, the sample block was sectioned to expose that location, followed by ultra-thin sectioning and TEM to inspect the internal structure of the cilia of the membrane epithelial cells with nanometre resolution. This method substantially reduced the time and labour of the search process from typically 20 sections for light microscopy to three sections with no added sample preparation. Lay description Electron microscopy provides very high levels of detail in a small area, and thus the question of where to look in an opaque sample, such as a stained tissue specimen, needs to be answered by sectioning the sample in small steps and examining the sections under a light microscope, until the region of interest is found. The search process can be lengthy and labor intensive, especially for a study involving a large number of samples. Small areas of interest can be missed in the process if not enough regions are examined. We also describe a method to directly locate the region of interest within a whole sample using micro-CT imaging, bypassing the need of blindly sectioning. Micro-CT enables locating the region within 3D space; this information provides a guide for sectioning the sample to expose that precise location for high resolution electron microscopy imaging. In a human tissue specimen study, this method considerably reduced the time and labor of the search process.

60 APPLIED LIFE SCIENCES↗

FY25 MOOSE Usability Improvements: 3D Meshing Capabilities, Initiation of Geometry Support for Monte Carlo Tools, and Enhancement of MOOSE/Workbench User Input Interactions

Usability improvements have been made to MOOSE and Workbench in FY25 to enhance usability and user workflows. Assorted enhancement have been made to MOOSE’s intrinsic meshing capabilities in order to enable more flexible and complex meshing of nuclear reactor systems, in particular for 3D applications. Mesh generators have been added to perform operations such as batch mesh generation, surface mesh generation, and creation of 3D transition layers. These mesh generation capabilities make it much easier to generate high quality non-extruded 3D meshes. Additionally, work to integrate Monte Carlo reactor physics simulations into MOOSE-based multi-physics workflows has reached another milestone with the implementation of the Constructive Solid Geometry (CSG) base framework. This framework lays the foundation for mesh generators to offer the user a generic CSG output option (as opposed to a finite element mesh). To support users, workshop on the MOOSE Reactor Module was delivered which featured hands-on examples using the NEAMS Workbench on INL’s High Performance Computing system. Recent updates to the NEAMS Workbench, WASP, and the MOOSE language server have introduced several improvements aimed at making MOOSE-based simulation setup and input management faster, more accurate, and easier to use. Key capabilities that have been added include multi-tab-stop autocompletion, visual input diagnostics, developer-directed data visualizations, upgraded ParaView integration, and Workspace-level file tracking. Together, these changes make it easier for users to build, validate, and manage complex MOOSE-based simulation models — especially those involving reusable components, included files, and datasets. The improvements are designed to save time, reduce input errors, and help users get to a successful simulation run faster, with more confidence in the results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗