Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Ice-Shelf Tidal Flexure and Subglacial Pressure Variations

We develop a model of an ice shelf-ice stream system as a viscoelastic beam partially supported by an elastic foundation. When bed rock near the grounding line acts as a fulcrum, leverage from the ice shelf dropping at low tide can cause significant (approx 1 cm) uplift in the first few kilometers of grounded ice.This uplift and the corresponding depression at high tide lead to basal pressure variations of sufficient magnitude to influence subglacial hydrology.Tidal flexure may thus affect basal lubrication, sediment flow, and till strength, all of which are significant factors in ice-stream dynamics and grounding-line stability. Under certain circumstances, our results suggest the possibility of seawater being drawn into the subglacial water system. The presence of sea water beneath grounded ice would significantly change the radar reflectivity of the grounding zone and complicate the interpretation of grounded versus floating ice based on ice-penetrating radar observations.

tidal↗

Seasonal Thermal Energy Storage Program

The Seasonal Thermal Energy Storage (STES) Program designed to demonstrate the storage and retrieval of energy on a seasonal basis using heat or cold available from waste or other sources during a surplus period is described. Factors considered include reduction of peak period demand and electric utility load problems and establishment of favorable economics for district heating and cooling systems for commercialization of the technology. The initial thrust of the STES Program toward utilization of ground water systems (aquifers) for thermal energy storage is emphasized.

Minor, J. E.↗

Southwest Water Resources: Monitoring Surface Water Extents of Remote Stock Ponds in the Southwestern United States Using Earth Observing Systems for Enhanced Water Resources Management

Due to increasingly frequent and severe drought conditions in the southwestern US, land managers and livestock producers need to monitor stock ponds with increasing regularity. The ability to assess stock pond water levels with Earth observing satellite systems would enhance monitoring efforts of partners at the US Forest Service, Arizona Department of Game and Fish, and the Diablo Trust. This study employed Landsat 8 Operational Land Imager (OLI), Sentinel-1 C-band Synthetic Aperture Radar (C-SAR), and Sentinel-2 Multispectral Instrument (MSI) to monitor surface water extent for hundreds of critical stock ponds in Arizona. Using methods adapted from previously developed image processing workflows, this project conducted a time-series analysis to capture seasonal and interannual variations in surface water area between 2013 to 2021. In addition, end users can monitor the surface water extent of stock ponds through the developed Google Earth Engine software tool called Surface Water Identification and Forecasting Tool (SWIFT). SWIFT incorporates the Automated Water Extraction Index, Modified Normalized Difference Water Index, and Tasseled Cap-Wetness Index for optical imagery and the incidence angle, VV and VH polarization bands for Sentinel-1 imagery to detect small water bodies in the study area with an overall accuracy range of 88-93%. These tools will empower our partners to monitor the extents of water in their stock ponds remotely, enabling them to develop data-informed and sustainable management solutions for decades to come.

Rainey Aberle↗

Modular, Mobile Systems for the Treatment of Contaminated Water at Three Magnox Sites in the United Kingdom - 20421

Veolia Nuclear Solutions (VNS), and its mitigated entity, Veolia Nuclear Solutions Federal Services (VNSFS), are designing, overseeing the fabrication and installation, and supporting the commissioning of highly mobile and modular skid-based water treatment systems to assist in the decommissioning of three Magnox reactor sites based in the U.K. These Modular Active Effluent Treatment Plants (MAETP) will be deployed at the Chapelcross, Hinkley Point A, and Dungeness A sites to process contaminated water through the use of ion exchange systems and/or filtration units. At the time of writing, two systems have been installed and inactively commissioned, and the third system is expected to be delivered in 2020. Veolia has utilized a multi-national team of engineers, based in the UK and the US, to effectively leverage the best of Veolia expertise in the design and delivery of mobile, modular systems. The VNS team continues to refine the modular, mobile, and scalable approach to water processing system delivery, and has successfully patented the evolving technology for proprietary protection. The intent of this technology investment is to improve the functionality, mobility, and modularity, resulting in a system which can be adapted to a broad range of throughput and isotope removal requirements to achieve the most cost effective, flexible system possible for customers. Designing, fabricating, and factory-testing the modules off site followed by onsite installation, testing, start-up, and commissioning ensures expedited delivery and setup, as well as cost savings for nuclear applications. For the MAETP systems, VNS's previous nuclear site experience and ongoing Research and Development (R and D), combined with the resulting mobile/modular water processing systems developed and successfully deployed by VNS, have proven to be important inputs for the successful end-design of the systems, materials selection, system testing and commissioning. The lessons learned in the development and continued enhancement of the patented systems described in this paper will prove useful in advancing and deploying future systems for other nuclear sites, where rapid customizing and cost-effective implementation are critical factors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design description of the Schuchuli Village photovoltaic power system

A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

Ratajczak, A. F.↗

Solar-powered hot-air system

Solar-powered air heater supplies part or all of space heating requirements of residential or commercial buildings and is interfaced with air to water heat exchanger to heat domestic hot water. System has potential application in drying agricultural products such as cotton, lumber, corn, grains, and peanuts.

Source record↗

Representation and Impact of Water Head on Power System Planning and Operation

Representing water head information in power system model files, can provide a more realistic model of the system and thereby inform operation and planning personnel in the decision-making process. This article describes a procedure for modifying the power system model files (steady-state and dynamic) to represent water head information. Additionally, the impact of representing the water head on power system reliability studies including contingency analysis, cascading failure analysis and dynamic frequency response analysis has been investigated, using the modified power system models. This paper considers the detailed Western Electricity Coordination Council model during summer and winter conditions as the test system for the impact analysis. Results show that under reduced water head: 1) the number of critical voltage and branch flow violations increases; 2) chances of cascading failure and island formation increases; and 3) frequency nadir decreases as compared to those of the base cases where the water head information is not represented.

13 - HYDRO ENERGY↗

Recent experiences with iodine water disinfection in Shuttle

Microbial proliferation in the STS potable water system is prevented by maintaining a 2-5 ppm iodine residual. The iodine is added to fuel cell water by an iodinated ion exchange resin in the Microbial Check Valve (MCV). Crew comments indicated excessive iodine in the potable water. To better define the problem, a method of in-flight iodine analysis was developed. Inflight analysis during STS-30 and STS-28 indicated iodine residuals were generally in the 9-13 ppm range. It was determined that the high iodine residual was caused by MCV influent temperatures in excess of 120 F. This is well above the MCV operating range of 65-90 F. The solution to this problem was to develop a resin suitable for the higher temperatures. Since 8 months were required to formulate a MCV resin suitable for the higher temperatures, a temporary solution was necessary. Two additional MCV's were installed on the chilled and ambient water lines leading into the galley to remove the excess iodine. These reduced the iodine residual to 3-4 ppm during STS-33, STS-34, STS-36 and STS-32. A high-temperature resin was formulated and initially flown on STS-31.

Gibbons, Randall E.↗

Monitoring of Ionic Silver Biocide with Capacitively-Coupled Contactless Conductivity Detection (C4D)

Monitoring of biocide dosing in spacecraft potable water systems is desirable to ensure dosing system operation and resultant microbial control. Electrolytic conductivity is linearly related to the concentration ionic silver (Ag+, the baseline biocide for future NASA missions) chemically dosed into highly purified water, and could serve as a proxy measurement. Traditional conductivity cells rely on immersed metal or graphite electrodes, which may potentially be subject to significant current-induced or auto-galvanic deposition of Ag+. Furthermore, oxide fouling may potentially induce measurement errors. Capacitively-coupled contactless conductivity detection (C4D) is a promising alternative. C4D uses electrodes placed outside an inert, non-conductive flow path, potentially mitigating such problems. We identified and purchased a commercial C4D system with claimed performance (conductivity range: 20 nS/cm to 4 µS/cm) appropriate for this application. We characterized the instrument’s performance with conductivity standards and Ag+ solutions. We began investigations considering practical and long-term detector operation, including potential current-induced deposition of conductive deposits at the tubing wall. In addition, we designed a side-stream flow system to provide liquid flow through the narrow tubing (1/16” outer diameter) required by the detector and characterized the performance of the combined C4D detector/flow system. Finally, we completed theoretical modeling of expected conductivity change with multiple dosing techniques and water chemistries.

Lance Dean Delzeit↗

Continuous sterilization of plumbing systems

Continuous sterilization of plumbing, such as in hospitals, clinics, and biological testing laboratories is possible with ethylene oxide/Freon 12 (ETO/F-12) humidifier developed for sterilization of potable water systems.

Bryan, C. J.↗

Assessing Adaptive Irrigation Impacts on Water Scarcity in Nonstationary Environments—A Multi‐Agent Reinforcement Learning Approach

Abstract One major challenge in water resource management is to balance the uncertain and nonstationary water demands and supplies caused by the changing anthropogenic and hydroclimate conditions. To address this issue, we developed a reinforcement learning agent‐based modeling (RL‐ABM) framework where agents (agriculture water users) are able to learn and adjust water demands based on their interactions with the water systems. The intelligent agents are created by a reinforcement learning algorithm adapted from the Q‐learning algorithm. We illustrated this framework in a case study where the RL‐ABM is two‐way coupled with the Colorado River Simulation System (CRSS), a long‐term planning model used for the administration of the Colorado River Basin, for assessing agriculture water uses impacts on water scarcity. Seventy‐eight intelligent agents are simulated, which can be grouped into three categories based on their parameter values: the “aggressive” (swift actions; low regrets), the “forward‐looking conservative” (mild actions; high regrets; fast learning), and the “myopic conservative” (mild actions; median regrets; slow learning). The ABM‐CRSS results showed that the major reservoirs in the Upper Colorado Basin might experience more frequent water shortages due to the increasing water uses compared to the original CRSS results. If the drought continues, the case study also demonstrates that agents can learn and adjust their demands.

Hung, Fengwei↗

Apollo experience report: Command and service module environmental control system

A comprehensive review is presented of the design philosophy of the Apollo environmental control system together with the development history of the total system and of selected components within the system. In particular, discussions are presented relative to the development history and to the problems associated with the equipment cooling coldplates, the evaporator and its electronic control system, and the space radiator system used for rejection of the spacecraft thermal loads. Apollo flight experience and operational difficulties associated with the spacecraft water system and the waste management system are discussed in detail to provide definition of the problem and the corrective action taken when applicable.

Samonski, F. H., Jr.↗

Aerodynamic thermal simulation system. Part 1: Radiant array (instruction manual)

An aerodynamic thermal simulation system (ATSS) is presented. The construction of the system, the maintenance, set up, and operations are reported. System description of the radiant array is given along with the array subsystems modular heating unit, adjustable stanchion frame, cooling water system, and the gaseous nitrogen cooling system. The array configuration procedure outlines the set up and the start up. Maintenance procedures involve both lamp maintenance and reflector maintenance along with weather protection. Drawing codes are included. Descriptions of the 36 zone ATSS controls are also given. Each zone is an independent closed loop temperature control circuit. Procedures are presented for starting and stopping the system. The DATA-TRAK programmer and its operation, instruction manuals for the temperature controller and the power regulator and discriptions of peripheral equipment are discussed.

Kitchar, A. F.↗

Modular solar-heating system - design package

Compilation contains design, performance, and hardware specifications in sufficient detail to fabricate or procure materials and install, operate, and maintain complete modular solar heating and hot water system for single family size dwellings.

Sinton, D. S.↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Preventing leaching from lead water pipes with electrochemistry: an exploratory study

Toxic levels of lead leaching from ageing water distribution infrastructure affect over 5000 public drinking water systems in the US. Pipe replacement, the most effective solution to this problem, is prohibitively expensive. Additionally, chemical conditioning of drinking water using orthophosphates, although cost-effective, does not quickly stop lead leaching once it has started. We propose a novel approach to stop lead leaching: to rapidly form an insoluble scale within lead pipes using an external power supply. We report on the feasibility of this approach by first anodizing lead coupons and lead pipes reclaimed from a local water distribution using a phosphate electrolyte and different potentials, pH values, and phosphate concentrations. We subsequently exposed these anodized lead coupons and pipes to synthetic tap water to evaluate their lead leaching rates. We found that polarizing lead coupons in the presence of a 0.05 M phosphate solution decreased lead leaching by up to a 100-fold, relative to leaching from polished bare lead. Similarly, polarizing the reclaimed lead pipes (with a preexisting scale) decreased lead leaching from an average of 36 ppb to 7 ppb. These results were observed when applying potentials that favor Pb(IV) formation, which resulted in the buildup of PbO 2 and Pb 5 (PO 4 ) 3 OH in both lead coupons and pipes. Our findings indicate that this novel technology has the potential to rapidly decrease equilibrium lead levels in tap water below the EPA action limit of 15 ppb, and thus deserves further exploration.

54 ENVIRONMENTAL SCIENCES↗

Is there a single origin of life?

The emergence of the first life on the earth is now established as an early event, closely related to the evolving earth. Lack of knowledge of the primitive terrestrial conditions contemporary with the evolving prebolic organic chemistry limits reconstruction techniques. The primitive earth's aqueous history is essential to unraveling this problem. Based on current knowledge of other planets of the solar system, no close analog to the early earth can be expected. It is still not known if there was a second origin or if only earth has life. This may depend upon the question of the survival of information-bearing chemical systems in a dynamic or chaotic environment and the chemical protection afforded within such a system. Water is the central molecule of controversy: the blessing and the curse of the chemist. New and novel chemical mechanisms and systems abound.

Soffen, Gerald A.↗