Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Beyond Strain: Controlling the Surface Chemistry of CsPbI 3 Nanocrystal Films for Improved Stability against Ambient Reactive Oxygen Species

Colloidal halide perovskite nanocrystals (NCs) have the possibility of easy scale-up due to their batch synthesis and have demonstrated excellent optoelectronic properties. In particular, perovskite NCs have remarkably high photoluminescence quantum yields in solution and as thin films and impressive open circuit voltages in photovoltaic devices. Despite these promising results, little work has been done to understand the stability of CsPbI 3 NCs for optoelectronic device applications. It has been previously shown that the ligands impart tensile surface strain, which stabilizes the black three-dimensional (3D) perovskite phase against phase degradation, making CsPbI 3 NCs some of the most structurally robust inorganic halide perovskites to date. However, understanding exactly how CsPbI 3 NCs degrade under ambient conditions is critical. Additionally, we demonstrate that the degradation mechanism of NCs is unique from, and 2 orders of magnitude slower than, their polycrystalline thin-film counterparts. Under specific conditions, CsPbI 3 NC films show a compositional instability instead of the phase instability seen in large grain CsPbI 3 . This is mediated through reactions with superoxide and other reactive oxygen species, which are initiated from surface defect states, O 2 and light. We then use this mechanistic insight to identify multiple strategies to prolong the lifetimes of CsPbI 3 NC films, by going beyond surface strain to mitigate key surface chemistries. We demonstrate that (1) minimizing the number of surface defects (2) using an alkylammonium bromide ligand surface treatment and (3) encapsulation with an oxygen scavenging layer all increase NC film lifetimes by inhibiting various steps in the photo-oxidation degradation reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NEXT Long-Duration Test After 11,570 h and 237 kg of Xenon Processed

The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation ion propulsion system with significant enhancements beyond the state-of-the-art in ion propulsion to provide future NASA science missions with enhanced mission capabilities at a low total development cost. As part of a comprehensive thruster service life assessment utilizing both testing and analyses, a Long-Duration Test (LDT) was initiated to validate and qualify the NEXT propellant throughput capability to a qualification-level of 450 kg, 1.5 times the mission-derived throughput requirement of 300 kg. This wear test is being conducted with a modified, flight-representative NEXT engineering model ion thruster, designated EM3. As of September 1, 2007, the thruster has accumulated 11,570 h of operation primarily at the thruster full-input-power of 6.9 kW with 3.52 A beam current and 1800 V beam power supply voltage. The thruster has processed 237 kg of xenon surpassing the NSTAR propellant throughput demonstrated during the extended life testing of the Deep Space 1 (DS1) flight spare. The NEXT LDT has demonstrated a total impulse of 9.78 10(exp 6) N(dot)s; the highest total impulse ever demonstrated by an ion thruster. Thruster performance tests are conducted periodically over the entire NEXT throttle table with input power ranging 0.5 to 6.9 kW. Thruster performance parameters including thrust, input power, specific impulse, and thruster efficiency have been nominal with little variation to date. Lifetime-limiting component erosion rates have been consistent with the NEXT service life assessment, which predicts the earliest failure sometime after 750 kg of xenon propellant throughput; well beyond the mission-derived lifetime requirement. The NEXT wear test data confirm that the erosion of the discharge keeper orifice, enlarging of nominal-current-density accelerator grid aperture cusps at full-power, and the decrease in cold grid-gap observed during NSTAR wear testing have been mitigated in the NEXT design. NEXT grid-gap data indicate a hot grid-gap at full-power that is 60 percent of the nominal cold grid-gap. This paper presents the status of the NEXT LDT to date with emphasis on comparison to the NSTAR extended life test results.

Soulas, George C.↗

A rejuvenation process to enhance the durability of low Pt loaded polymer electrolyte membrane fuel cells

Here, an effective method to enhance the durability of polymer electrolyte membrane fuel cells (PEMFCs) is reported. PEMFC performance loss is mitigated by exposing the electrodes of fuel cells to dry nitrogen gas periodically at high temperature. This method extends the lifetime of fuel cells significantly compared to their non-treated counterparts. The impact of treatment temperature and exposure time on PEMFC durability is reported, using potential cycling accelerated stress tests. The enhanced durability is attributed to the suppression of “ionomer relaxation” that occurs under the nearly water saturated operating conditions of a PEMFC cathode.

30 DIRECT ENERGY CONVERSION↗

Using Energy Storage-Based Grid Forming Inverters for Operational Reserve in Hybrid Diesel Microgrids

In remote arctic communities, where access to a bulk electrical grid interconnection is not available, the implementation of islanded microgrids has been the most viable way to produce and distribute electricity services to their inhabitants. Historically, these islanded grids have relied primarily on diesel generators or hydropower resources to supply the baseload. However, this practice can result in increased expense due to the high costs associated with fuel transportation and the significant amounts of on-site storage necessary when fuel transportation is unavailable during winter months. In order to mitigate this problem, arctic microgrids have started to transition to a hybrid-source operational mode by incorporating renewable energy sources that are inherently variable in nature, such as wind or solar. Due to their highly stochastic behavior, these hybrid-source islanded microgrids can pose potential issues related to power quality due to introduction of rapid net load fluctuations and inability of diesel generators to respond rapidly. In addition, non-firm stochastic sources can require significant idling diesel generator resources to serve as spinning reserves, which is inefficient and wasteful. This work studies the problems that may arise in the transient dynamics of a real-world hybrid diesel microgrid when subjected to a loss of wind generation. Moreover, this work proposes a transition from a diesel spinning reserve to a battery energy-storage system (BESS) operating reserve scheme. The study of the proposed transition is important in establishing the fundamental implication of transient dynamics and the potential benefits of integrating a BESS as a spinning reserve in terms of stability, frequency nadir, and transient voltage deviation. The methods to investigate and validate the transient dynamics relied on both electromagnetic simulation models of GFMIs and a commercially available GFMI in an experimental power hardware-in-the-loop setup. The simulation results showed that the proposed operating reserve scheme improves the power quality of the system in terms of voltage deviation and frequency nadir when the microgrid is subjected to a loss of wind generation scenario. Depending on the simulation cases, adding a GFMI reduced the frequency nadir between 65.3% and 86.7%. Moreover, the reductions in the voltage deviations improved between 3.6% and 23.0%. From these results it can be concluded that the integration of a GFMI can reduce the frequency nadir in a hybrid diesel microgrid, and in turn, reduce diesel consumption, which improves system reliability while reducing fuel expenses. Furthermore, the novelty of this work relies on the fact that the offline simulation results were validated using a power hardware-in-the-loop platform that incorporated a 100 kVA commercially available GFMI as the device under test.

Hernandez-Alvidrez, Javier↗

Durability of Metallic Interconnects and Protective Coatings

To build up a useful voltage, a number of solid oxide fuel cells (SOFCs) are electrically connected into series in a stack via interconnects, which are placed between adjacent cells. In addition to functioning as a bi-polar electrical connector, the interconnect also acts as a separator plate that separates the fuel at the anode side of one cell from the air at the cathode side on an adjacent cell. During SOFC operation at the high temperatures, the interconnects are thus simultaneously exposed to the oxidizing air at one side and a reducing fuel that can be either hydrogen or hydrocarbon at the other. Besides, they are in contact with adjacent components, such as electrodes or electrical contacts, seals, etc. With steady reduction in SOFC operating temperatures into the low or intermediate range 600-850oC, oxidation resistant alloys are often used to construct interconnects. However, the metallic interconnects may degrade via interactions at their interfaces with surrounding environments or adjacent components, potentially affecting the stability and performance of interconnects and the SOFC stacks. Thus protection layers are applied to metallic interconnects that also intend to mitigate or prevent chromium migration into cells and the cell poisoning. This chapter provides a comprehensive review of materials for metallic interconnects, their degradation and coating protection.

solid oxide fuel cell, interconnect, oxidation, co↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Cycling behavior of NCM523/graphite lithium-ion cells in the 3–4.4 V range: Diagnostic studies of full cells and harvested electrodes

Energy density of full cells containing layered-oxide positive electrodes can be increased by raising the upper cutoff voltage above the current 4.2 V limit. In this article we examine aging behavior of cells, containing LiNi 0.5 Co 0.2 Mn 0.3 O 2 (NCM523)-based positive and graphite-based negative electrodes, which underwent up to ~400 cycles in the 3-4.4 V range. Electrochemistry results from electrodes harvested from the cycled cells were obtained to identify causes of cell performance loss; these results were complemented with data from X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectroscopy (SIMS) measurements. Our experiments indicate that the full cell capacity fade increases linearly with cycle number and results from irreversible lithium loss in the negative electrode solid electrolyte interphase (SEI) layer. The accompanying electrode potential shift reduces utilization of active material in both electrodes and causes the positive electrode to cycle at higher states-of-charge. Here, full cell impedance rise on aging arises primarily at the positive electrode and results mainly from changes at the electrode-electrolyte interface; the small growth in negative electrode impedance reflects changes in the SEI layer. Our results indicate that cell performance loss could be mitigated by modifying the electrode-electrolyte interfaces through use of appropriate electrode coatings and/or electrolyte additives.

30 DIRECT ENERGY CONVERSION↗

Re-Configurable Electronics Characterization under Extreme Thermal Environment

The need for reconfigurable electronics is driven by requirements to survive longer missions and harsher environments. It is possible to compensate for degradations in Extreme Environments (EE). EE has effect on electronics: circuits are designed to exploit device characteristics and when a certain temperature or radiation range is exceeded the circuit function gradually degrades. It is possible to employ Hardening by reconfiguration (HBR) to mitigate drifts, degradation, or damage on electronic devices in EE by using reconfigurable devices and an adaptive self-reconfiguration of circuit topology. In this manner degraded components can be salvaged, and completely damaged components can be bypassed. The challenge of conventional design is replaced with that of designing a recover process that automatically performs the (re) design in place of the designer. The objective of testing a Digital Signal Processor (DSP) under the extreme temperatures was to determine the lowest temperature at which the DAP can operate. The objective of testing a Xilinx VirtexII Pro FPGA board was to initially find our whether the evaluation board and the FPGA would survive and continue at temperature ranges from -180 C, and 120 C. The Virtex II functioned correctly at the temperatures tested. The next test was done on the GM-C filter building block using the same temperature range as the Virtex II. The current lower and upper limits were shown to be reduced as the temperature gets lower. The device function can be recovered by increasing the Vb from .08V to .85V. The negative and positive saturation voltages increases as the temperature gets higher. The function of the device can be recovered by decreasing the Vb from .8V to around .75V. The next test was performed to test the recovery of the GmC low pass filter through Vb in a filter circuit. The test indicate that bias voltage control adjustment is an efficient mechanism for circuit recovery at extreme temperatures.

reliability↗

Thermodynamics of a Dual Stage Sodium Thermo-Electro-Chemical Converter

The need for reliable and distributable energy is evident, but one prominent obstacle is the lack of an efficient direct heat-to-electricity converter. The sodium thermo-electro-chemical converter (Na-TECC) is a highly efficient thermally regenerative electrochemical system (TRES) that can fill this void. This electrochemical technology uses an ion-selective solid-electrolyte called beta-alumina that is highly conductive to sodium cations. The Na-TECC generates electric power by allowing high pressure sodium cations to expand isothermally through the solid-electrolyte. Theoretically, a device interacting with thermal reservoirs at 1150 K and 550 K should operate above 45% efficiency, but actual devices have not surpassed efficiencies of 20%. The maximum potential voltage in these previous devices was substantially reduced by the kinetic limitations of the charge transfer in the cathode (referred to as the overpotential) and by Joule heating losses due to the solid-electrolyte resistance, electrode resistance, and current collector resistance. To overcome this discrepancy, a dual stage conversion process is being proposed. Rather than using one isothermal expansion step, the dual cycle will employ two separate electrolytes to allow two separate expansion steps: one at the high temperature, and another at an intermediate temperature. This new cycle is thermodynamically favorable as it allows for regeneration from the isobaric cooling of the first expansion step, and reheat to complete the expansion in the second step. This allows the engine to reach a lower condenser temperature than its single stage counterpart for a given heat input, resulting in an increased overall efficiency. The temperature drop across each electrolyte in the dual stage device (e.g., ~ 400 K) is smaller than the temperature drop across a comparable single stage device (e.g., ~ 800 K). This makes the device amenable to better thermal management and allows for less heat loss. Also, the intermediate stage will mitigate the thermal shock across the very thin (< 1 mm) solid electrolyte, reduce crack propagation, limit the percolation of the molten dendrites, and ultimately increase the lifetime of the device. A dual stage concept for the Na-TECC has never been demonstrated in literature, so it is necessary to properly re-define the thermodynamic parameters such as heat loss, maximum power, and optimal current density. Certain drawbacks from a dual stage concept will also be addressed, such as the need for larger electrochemical area and the increased pressure losses. It will be demonstrated that the dual stage device must have lower thermal losses than a single stage device if it is to have a higher efficiency. The improved operation of the Na-TECC can have a transformational effect on small combined heat and power (CHP) systems at the 1-5 kW range.

14 SOLAR ENERGY↗

Dual Stage Sodium Thermo-Electro-Chemical Converter (Na-TEC)

The need for reliable and distributable energy is evident, but one prominent obstacle is the lack of an efficient direct heat-to-electricity converter. The sodium thermo-electro-chemical converter (Na-TECC) is a highly efficient thermally regenerative electrochemical system (TRES) that can fill this void. This device uses an ion-selective solid-electrolyte called beta”-alumina that is highly conductive to sodium cations. The Na-TECC generates electric power by allowing high pressure sodium cations to expand isothermally through the solid-electrolyte. Theoretically, a device interacting with thermal reservoirs at 1150 K and 550 K should operate above 45% efficiency, but actual devices have not surpassed efficiencies of 20%. The maximum potential voltage in these previous devices was substantially reduced by the kinetic limitations of the charge transfer in the cathode, by pressure losses through the porous electrodes, and by Joule heating losses caused by the solid-electrolyte, electrode, and current collector resistances. To overcome these low efficiencies, a dual stage conversion process is being proposed. Rather than using one isothermal expansion step, the dual cycle will employ a second electrolyte to allow two separate expansion steps: one at the high temperature, and another at an intermediate temperature. This new cycle is thermodynamically favorable as it allows for regeneration from the isobaric cooling of the first expansion step, and reheat to complete the expansion in the second step. This allows the engine to reach a lower condenser temperature than its single stage counterpart for a given heat input, resulting in an increased overall efficiency. The temperature drop across each electrolyte in the dual stage device (e.g., ~ 400 K) is smaller than the temperature drop across a comparable single stage device (e.g., ~ 600 K). This makes the device amenable to better thermal management and allows for less heat loss. Also, the intermediate stage will mitigate the thermal shock across the very thin (< 1 mm) solid electrolyte, reduce crack propagation, limit the percolation of the molten dendrites, and ultimately increase the lifetime of the device. A dual stage concept for the Na-TECC has never been demonstrated in literature, so it is necessary to properly re-define the thermodynamic parameters such as heat loss, maximum power, and optimal current density. Certain drawbacks from a dual stage concept will also be addressed, such as the need for larger electrochemical area and the increased pressure losses. It will be demonstrated that the dual stage device must have lower thermal losses than a single stage device if it is to have a higher efficiency. The improved operation of the Na-TECC can have a transformational effect on small combined heat and power (CHP) systems at the 1-5 kW range.

14 SOLAR ENERGY↗

Experimental investigation of PDI bifurcation of lower hybrid waves during electron density ramp-up in EAST

Abstract The effect of parametric decay instability (PDI) on the current drive efficiency of 4.6 GHz lower hybrid (LH) waves in EAST is investigated experimentally, showing the PDI channel bifurcation of LH waves for the first time in EAST. First, experiments with three platforms of LH power were performed, achieving the LH power required for the PDI occurrence. Second, PDI bifurcation experiments were further carried out by ramping up the plasma electron density. The loop voltage increases with an increase in density, implying a decrease in the current driven by the LH wave. PDI bifurcation during electron density ramp-up was studied by analyzing the parallel refractive index ( n ∥ ) and the frequency spectrum broadening, which is measured with a radio frequency magnetic probe array recently installed close to the LH antenna. It is observed for the first time that they both first increase with density, then there is not much variation and a clear sideband in the frequency spectrum is also observed when the density is up to 4 × 10 19 m − 3 , suggesting a change in the PDI channel. Calculation of the mode growth rate driven by PDI shows that when the edge electron density is up to 1.9 × 10 18 m − 3 , the growth rate of the ion cyclotron quasi-mode (ICQM) will exceed that of the ion sound quasi-mode (ISQM), quantitively explaining that with an increase in density, the PDI channel partly transits from the ISQM to the ICQM channel. Studies provide a possible way to reduce the power deposition in the edge region and improve drive capability by means of mitigating PDI behavior.

Physics↗

Uniform lithiophilic layers in 3D current collectors enable ultrastable solid electrolyte interphase for high-performance lithium metal batteries

Uniform lithium plating/stripping during charging/discharging in 3D lithiophilic current collectors (3DLCC) is essential to suppress growth of lithium dendrites and to mitigate infinite volume variations of lithium metal for long-lived lithium metal batteries. Additionally, this study reveals the decisive role played by uniformity of the lithiophilic layer of the 3DLCC in achieving uniform lithium plating/stripping. Herein, a series of metal oxide-based 3DLCCs are successfully fabricated with a simple and an ultrafast solution combustion method, from which formation of a uniform and stable lithium dendrite-free solid electrolyte interphase via a uniform lithiophilic layer is demonstrated. Taking Co 3 O 4 as the lithiophilic material deposited on a nickel foam as the 3DLCC (Co@NF) for a proof of concept, the loading amount of Co 3 O 4 , closely correlated with the uniformity of the Co 3 O 4 layer, is modulated to optimize its lithium ion hosting performances. With a uniform Co 3 O 4 layer grown in the 3DLCC, an ultralow nucleation overpotential of 33.4 mV is achieved in half-cell tests at 1 mA cm -2 and 1 mAh cm -2 , and a high Coulombic efficiency of 97.1% is maintained after 210 cycles under a severe cycling condition of 2 mA cm -2 and 1 mAh cm -2 . A small polarization voltage of 13 mV together with an ultralong cycle life of 2400 h at 0.5 mA cm -2 and 1 mAh cm -2 in symmetric Li cells is achieved. Moreover, the composite Li anode delivers sensational rate capability and cyclability in full-cells. This work not only provides new and valuable insights into the interphasial chemistry of solid electrolyte interphase layers, but also sheds light on the development of ultrastable lithium metal batteries.

25 ENERGY STORAGE↗

Impacts of Carrier Transport and Deep Level Defects on Delayed Cathodoluminescence in Droop-Mitigating InGaN/GaN LEDs

Prevalent droop mitigation strategies in InGaN-based LEDs require structural and/or compositional changes in the active region but are accompanied by a detrimental reduction in external quantum efficiency (EQE) due to increased Shockley-Read-Hall recombination. Understanding the optoelectronic impacts of structural modifications in InGaN/GaN quantum wells (QW) remains critical for emerging high-power LEDs. In this work, we use a combination of electron microscopy tools along with standard electrical characterization to investigate a wide range of low-droop InGaN/GaN QW designs. We find that chip-scale EQE is uncorrelated with extended well-width fluctuations observed in scanning transmission electron microscopy. Further, we observe delayed cathodoluminescence (CL) response from designs in which calculated band profiles suggest facile carrier escape from individual QWs. Samples with the slowest CL responses also exhibit the lowest EQEs and highest QW defect densities in deep level optical spectroscopy. We propose a model in which the electron beam (i) passivates deep level defect states and (ii) drives charge carrier accumulation and subsequent reduction of the built-in field across the multi-QW active region, resulting in delayed radiative recombination. Finally, we correlate CL rise dynamics with capacitance-voltage measurements and show that certain early-time components of the CL dynamics reflect the open circuit carrier population within one or more QWs.

Zhao, Zhibo↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Predicting Thermal Response in a Li-ion Cell on a UAV Fight Profile

As the energy storage devices continue to "pack" more energy in a small space, any damage, battery component failure, manufacturing defect, or electrically abusing the battery can lead to catastrophic thermal runaway events. A catastrophic thermal event in a cell leads to high temperature, in some instances spewing of battery materials due to gas development from side reactions initiated due to high internal temperatures. Also, a thermal runaway event can propagate from a single "failed" cell to the pack in a battery pack, leading to a more significant event. Mitigating a thermal runaway event is important in the commercial and automotive sectors. However, preventing such events in an electric aircraft (or air taxis) is paramount due to the lack of alternatives in the event of a failure. Battery prognostics algorithms allow the prediction of state-of-charge (SOC) and end-of-life (EOL) of a Li-ion battery in a UAV (unmanned air vehicle) [1]. For this presentation, we will extend this two-level battery predictive algorithm to predict SOC, EOL, and estimated maximum temperature during a simulated flight. The model is extended by integrating a lumped physics-driven thermal model for high current densities [2]. The parameters used to control SOC and EOL are maximum storable charge, time constant for Li-ion diffusivity in the carbon particles, and internal cell resistance. Cycling leads to an increase in the heat generated by an aged Li-ion cell with a LiyCoO2 (LCO) cathode and a LixC6 (MCMB) anode. The aging of a cell leads to increase in SEI layer thickness, the diffusion time for the lithium ions inside the electrodes, and the local reaction rates, in addition to the thermodynamic abuse caused by fixed cycling voltages controlled by a Battery Management System. As the battery ages, the cell resistance increases, while the onset temperature of the thermal runaway decreases (depends on the cell chemistry and cell abuse history). Any large deviation of the cell temperature from the estimated (expected) value can identify a faulty cell. Since SEI decomposition has the lowest onset temperature in the series of reactions leading to thermal runaway, the model considers the self-heating rate of the SEI decomposition as onset temperature (similar to Ref. [3]). The parameters in the Arrhenius equation for the SEI heating rate depend on the number of cycles, the cell's operating temperature, and the cell's abuse history [4,5]. Coupling the electrochemical, thermal, and aging model allow the prognostic algorithm to estimate a typical cell voltage and temperature as a function of age (cycling and calendar), whose departure from measured values from the BMS is used to identify a safety event. In addition, we will present the results from two simulated flight scenarios for a UAV: typical and extreme, since the power requirements vary significantly during take-off, landing, and changing altitudes, while the power requirements remain low during the cruise. For this presentation, the power requirement for a battery pack in a UAV is scaled to a single cell. This cell is cycled through a simulated profile, and the data is collected and used to predict a safety event.

Li-ion↗

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. Here, in this paper, we mitigate these limitations by developing a novel deep meta-reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method, which achieves superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heteropoly acid functionalized fluoroelastomer with outstanding chemical durability and performance for vehicular fuel cells

To further facilitate commercialization of automotive fuel cells, durability concerns need to be addressed. Currently the addition of a mechanical support in the membrane is able to adequately solve issues of mechanical degradation, but chemical degradation via oxygenated radical attack remains an unsolved challenge. Typical mitigation strategies use cerium or manganese species to serve as radical scavengers, but these ions are able to migrate in the membrane and even leach out of the system. The approach used in this paper is to covalently link and immobilize a heteropoly acid (HPA), more specifically 11-silicotungstic acid (HSiW11), a lacunary HPA of the Keggin structure to a fluoroelastomer, serving as both a radical decomposition catalyst and the proton conducting acid. This dual functionality allows for both high content of radical scavenging species and high ion-exchange capacity. An efficient three step, high yield (77%), commercially viable synthesis for this polymer is reported. The synthesis route for making this new heteropoly acid functionalized polymer is confirmed using infrared spectroscopy (IR), nuclear magnetic resonance (NMR) spectroscopy, and thermogravimetric analysis (TGA). The material exhibits clustering of the HSiW11 moieties, resulting in a poorly connected proton conducting phase when dry, but excellent conductivity is achieved at elevated humidities (0.298 S cm -1 at 80 °C and 95% RH). The proton conductivity shows an enhancement above 60 °C due to a softening of the polymer, as shown by DSC. Under an aggressive chemical accelerated stress test (AST), 90 °C, 30% RH, zero current, and pure O 2 , the PolyHPA losses only 0.05 V of open circuit voltage (OCV) after 500 h, greatly out performing any other material reported in the literature. For comparison, the Nafion® N211 fuel cell drops below 0.8 V after only 76 h under the same conditions. Finally, in fuel cell testing the PolyHPAs have outstanding chemical stability and also possess very low in situ high frequency resistance (HFR) leading to high performance (1.14 W cm -2 at 2 A cm -2 ), compared to 1.11 W cm -2 for the Nafion® N211 fuel cell at the same current. At 75 wt% HSiW11 loading, the fuel cell HFR showed a 22% decrease over N211.

30 DIRECT ENERGY CONVERSION↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗