Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “validation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Search for Higgs Boson and Observation of $Z$ Boson through Their Decay into a Charm Quark-Antiquark Pair in Boosted Topologies in Proton-Proton Collisions at $\sqrt{s}$ = 13 TeV

A search for the standard model (SM) Higgs boson ($H$) produced with transverse momentum ($p_T$) greater than 450 GeV and decaying to a charm quark-antiquark ($c\bar{c}$) pair is presented. The search is performed using proton-proton collision data collected at $\sqrt{s} = 13$ TeV by the CMS experiment at the LHC, corresponding to an integrated luminosity of 138 fb$^{-1}$. Boosted $H \to c\overline{c}$ decay products are reconstructed as a single large-radius jet and identified using a deep neural network charm tagging technique. The method is validated by measuring the $Z \to c\bar{c}$ decay process, which is observed in association with jets at high $p_T$ for the first time with a signal strength of $1.00^{+0.17}_{-0.14}$ (syst)$\pm 0.08$ (theo) $\pm 0.06$ (stat), defined as the ratio of the observed process rate to the SM expectation. The observed (expected) upper limit on $\sigma (H){\cal B}(H \to c\overline{c})$ is set at 47 (39) times the SM prediction at 95\%confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gradient-Descent-Based Learning Gain for Backstepping Controller and Disturbance Observer of Nonlinear Systems

This paper proposes a gradient-descent-based learning (GL) gain for backstepping controller and disturbance observer (DOB) of nonlinear system. The proposed method consists of the GL gain update law, controller, and DOB. The GL gain update law is proposed to adapt the control gain and DOB gain according to the direction that minimizes the cost function. The mathematical analysis reveals that the GL gain always has a positive sign and upper bound. The controller is designed via a backstepping procedure to track the desired output with GL control gain. The DOB is designed to estimate the unknown external disturbance with the GL DOB gain. Because the control and DOB gains are simultaneously tuned to achieve improved performance, the time consumption for tuning can be reduced. In addition, the peaking phenomenon can be avoided initially by a small initial value of GL gains. The stability of the closed-loop system is guaranteed using the input-to-state stability property. The performance of the proposed method was validated via simulations and experiments using a DC motor.

42 ENGINEERING↗

Strategic Placement and Sizing of Distributed Generation for Resilience Enhancement of Distribution Grids With Microgrid Formation

The rise in frequency and severity of extreme weather events highlights the need for resilient power distribution networks. Microgrids can help improve the resilience of distribution grids by providing continuous power supply using local distribution generation (DG) when the distribution grid fails. In this paper, we propose an approach for optimal placement and sizing of DG to form multiple microgrids throughout the distribution network by restoration actions such as switching operations in case of distribution grid outages caused by extreme weather events. Considering the randomness of damaged distribution lines, the DG placement and sizing problem is formulated as a two-stage stochastic mixed-integer program, with the first stage determining the placement and size of DG, and the second stage focusing on minimizing the amount of load shedding through network restoration and microgrid formations for each scenario. Due to the large number of scenarios, the sample average approximation (SAA) method is employed to solve the problem. The results of case studies on a modified IEEE 33 bus distribution grid demonstrate the effectiveness of the proposed DG placement and sizing strategy in improving the resilience of distribution grids by allowing the formation of multiple microgrids. In addition, the robustness and accuracy of the SAA method are validated through various case studies.

Distributed generation planning↗

Adaptive Online Model Update Algorithm for Predictive Control in Networked Systems

In this article, we introduce an adaptive on-line model update algorithm designed for predictive control applications in networked systems, particularly focusing on power distribution systems. Unlike traditional methods that depend on historical data for offline model identification, our approach utilizes real-time data for continuous model updates. This method integrates seamlessly with existing online control and optimization algorithms and provides timely updates in response to real-time changes. This methodology offers significant advantages, including a reduction in the communication network bandwidth requirements by minimizing the data exchanged at each iteration and enabling the model to adapt after disturbances. Furthermore, our algorithm is tailored for non-linear convex models, enhancing its applicability to practical scenarios. The efficacy of the proposed method is validated through a numerical study, demonstrating improved control performance using a synthetic IEEE test case.

data-driven model predictive control↗

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling Visualization, Simulation, and Deep Learning for Ensemble Steering of Complex Energy Models

We describe a new framework that allows users to explore and steer ensembles of energy systems simulations by coupling multiple energy models and interactive visualization through a dataflow API. Through the visual interface, users can interactively explore complex parameter spaces populated by hundreds, or thousands, of simulation runs and interactively spawn new simulations to 'fill in' regions of interest in the parameter space. The computational and visualization capabilities reside within a general-purpose dataflow architecture for connecting producers of multidimensional timeseries data, such as energy simulations, with consumers of that data, whether they be visualizations, statistical analyses, or datastores. Fast computation and agile dataflow can enhance the engagement with energy simulations, allowing users to populate the parameter space in real time. However, many energy simulations are far too slow to provide an interactive response. To support interactive feedback, we are creating reduced-form simulations developed through machine learning techniques, which provide statistically sound estimates of the results of the full simulations at a fraction of the computational cost. These reduced-form simulations have response times on the order of seconds, suitable for real-time human-in-the-loop design and analysis. The approximation methods apply to a wide range of computational models, including supply-chain models, electric power grid simulations, and building models. Such reduced-form representations do not replace or re-implement existing simulations, but instead supplement them by enabling rapid scenario design and exploration for large ensembles of simulations. The improved understanding, facilitated by the reduced-form models, dataflow API, and visualization tools, allows researchers to better allocate computational resources to capture informative relationships within the system as well as provide a low-cost method for validating and quality-checking large-scale modeling efforts.

97 MATHEMATICS AND COMPUTING↗

Secure Firmware Update and Device Authentication for Smart Inverters using Blockchain and Physically Uncloable Function (PUF)-Embedded Security Module

Cybersecurity of inverters has been significantly important as inverters become smarter in cyber-physical environments. However, firmware security of smart inverters against firmware attacks from various attack vectors has been less studied. Furthermore, this paper proposes a secure firmware update and device authentication method using a blockchain-based public key infrastructure (PKI) management system and a physically unclonable function (PUF)-embedded security module in a smart inverter. The proposed method is validated by experiments.

blockchain↗

SO(3)-invariant PCA with application to molecular data

Principal component analysis (PCA) is a fundamental technique for dimensionality reduction and denoising; however, its application to three-dimensional data with arbitrary orientations -- common in structural biology -- presents significant challenges. A naive approach requires augmenting the dataset with many rotated copies of each sample, incurring prohibitive computational costs. In this paper, we extend PCA to 3D volumetric datasets with unknown orientations by developing an efficient and principled framework for SO(3)-invariant PCA that implicitly accounts for all rotations without explicit data augmentation. By exploiting underlying algebraic structure, we demonstrate that the computation involves only the square root of the total number of covariance entries, resulting in a substantial reduction in complexity. We validate the method on real-world molecular datasets, demonstrating its effectiveness and opening up new possibilities for large-scale, high-dimensional reconstruction problems.

Fraiman, Michael [Tel Aviv Univ., Tel Aviv (Israel↗

Distributed Algorithm for Volt-VAr Optimization in Unbalanced Distribution System

Conservation voltage reduction (CVR) is implemented in the distribution system to reduce the voltage along the feeder with the objective to reduce the power consumption. Due to the increased penetration of distributed generators in the distribution system the centralized control is cumbersome. Hence, in this paper, a distributed algorithm is proposed for volt-var optimization (VVO) with CVR objective in a three-phase unbalanced distribution network. The proposed method is based on alternating direction method of multipliers (ADMM) algorithm. Mathematically the problem is formulated as a convex optimization problem with reactive power support from smart inverters. The convexity guarantees the solution obtained using the proposed method is a converged solution. The proposed method is validated on IEEE 4-bus and 13-bus three-phase unbalanced systems.

ADMM↗

A Data-Driven Method for Estimating Behind-the-Meter Photovoltaic Generation in Hawaii

Due to the increasing penetration of distributed behind-the-meter photovoltaic (PV) systems and the installed utility revenue metering limited to monitoring only the net power import/export of the household, it is increasingly challenging for utilities to effectively plan and operate the grid. This paper proposes a methodology that estimates behind-the-meter PV generation using a selected subset of monitored PV systems. It is a data-driven approach, and the PV output is estimated utilizing a statistic regression model. A Minimum Redundancy Maximum Relevance (MRMR) algorithm is applied to preselect the optimal subset of the monitored PV systems. The performance of this approach is compared with a spatial interpolation method and a model-based approach. The proposed method is validated using high-resolution meter data recorded from 18 residential rooftop PV systems located on the island of Maui, Hawaii.

Data-driven modeling↗

Optimal Voltage Control in Low-Observable Unbalanced Distribution Systems

The increased integration of distributed energy resources (DERs) in distribution systems brings both advantages and technical challenges. High levels of DERs can often cause over/under voltage problems. Classical voltage control algorithms are based on full knowledge of voltage states across all nodes in the system. However, this may not be a practical assumption since many locations in distribution systems are unobservable. Therefore, this paper proposes a new model predictive control (MPC) based control algorithm that accounts for system unobservability to efficiently eliminate voltage violations with as low as 50% fraction of observable nodes. Additionally, an analytical voltage sensitivity framework is employed to quickly determine the change in voltage states due to PV injections. The effectiveness of the proposed method is validated via simulations on the unbalanced IEEE 37 node test system.

Abujubbeh, Mohammad↗

Mass Detection for Heavy-Duty Vehicles using Gaussian Belief Propagation

Predicting vehicle mass is critical to accurately estimate energy use and emissions of commercial trucks. However, data from vehicle telematics is often not at sufficient temporal resolution or accuracy for use in model-based detection methods. In this work, a new statistical mass prediction technique is described for heavy-duty vehicles that incorporates the use Gaussian Belief Propagation (GBP) for probabilistic inference. Similar to Bayesian inference models, the GBP model typically requires less labeled training data than other contemporary machine learning techniques. First, a factor graph is constructed, and a set of Gaussian belief nodes with associated means and variances are fitted to the training data. To better handle noisy input data, the GBP mass prediction model utilizes a k-nearest factors (kNF) algorithm for probabilistic inference on unseen testing data. The proposed method is compared with a classical weighted k-nearest neighbors (kNN) regressor. This statistical kNF-GBP model works even with low-quantity, low-quality initial training data, while being capable of realtime mass estimation. Unlike the kNN regressor, the GBP model produces a measure of uncertainty with its predictions. The proposed method is validated using curve-sampled driving data collected from multiple cloud-connected Class 8 regional haul diesel trucks. Both the kNN regressor and the kNF-GBP mass prediction model were able to predict payload mass with coefficients of determination above 0.97 with minimal data preprocessing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

Voltage Probability Density Function Shaping Control Strategy Considering Grid Operational Uncertainties

It is well-known that power systems operation always affected by various uncertainties which make the bus voltage a random process that can be characterized by its probability density function (PDF) at any time instant. In this context, this paper presents a novel PDF-based voltage control framework for power systems. By modeling voltage as a stochastic process, we formulate a stochastic differential equationthat captures grid uncertainties. The associated Fokker-Planck-Kolmogorov equation is derived to describe the evolution of the voltage PDF, which enables the formulation of a PDF-shaping control strategy. To simplify the PDF control formulation, a B-spline neural network is introduced for real-time estimation and regulation of the voltage distribution. The proposed PDF control law updates voltage references for energy storage systems and synchronous generators using real-time PDF measurements and feedback signals. The proposed method is validated on a modified Kundur’s two-area system. Simulation results demonstrate that the controller can significantly improve the voltage stability under stochastic conditions, highlighting its effectiveness in modern inverter-rich grids.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)↗

Electromagnetic Transient Simulation of Large-Scale Inverter-Based Resources With High-Granularity

The power grid is undergoing a significant transformation with the rapid increase in inverter-based resources (IBRs), including large-scale photovoltaic (PV) plants. Ensuring reliable and resilient grid operation in this new paradigm necessitates high-granularity electromagnetic transient (EMT) modeling that accurately captures the behavior of individual inverters and their interactions within IBR plants. Central to this approach is the detailed representation of both the IBR plant’s collector system and the dynamics of individual inverters. To achieve this, a high-granularity EMT model of a large-scale PV plant has been developed using advanced simulation algorithms, including matrix splitting and the Schur complement. These proposed techniques significantly enhance simulation speed, numerical stability, and accuracy while improving the modularity and efficiency of the collector system’s representation. The effectiveness of the proposed methods is validated through simulations of a representative large-scale PV plant consisting of 125 individual PV inverters, 25 IBR unit transformers, and a 52-bus collector system.

Choi, Jongchan [Oak Ridge National Laboratory (ORN↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops a machine learning based approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurement. The machine learning model is developed by using random forest algorithm. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

advanced metering infrastructure↗

Consensus-Based Approach for Active Power Control and Reserve Estimation in Distributed PV Systems

With the increased adoption of distributed energy resources (DER), they are expected to contribute to power system reliability services and enhance power system stability. This paper presents a distributed consensus control approach for the real-time active power reserve estimation and power management in distributed PV (photovoltaic) systems. The proposed method estimates the cumulative active power reserve from numerous PV generators using only the sparse communication network for a DER aggregator to provide active power regulation services. The real-time active power reserve estimation using the proposed approach can be used by DER aggregators to manage curtailment in distributed PV systems to maintain stipulated reserves and further to provide power system frequency regulation. Using the proposed approach, the DER aggregator only requires measurements at the feeder substation and it does not require information from individual DER units, thereby improving system resiliency. The proposed distributed consensus control method is validated on IEEE 123 testbed using PSCAD simulations.

active power reserve↗

Probing-Based Inertia Estimation Method Using Hybrid Power Plants

With the displacement of synchronous generation by inverter-based resources (IBRs), power systems could face the challenge of reduced inertia since IBRs do not inherently contribute to system inertia. Therefore, there is rising interest in monitoring system inertia in real-time applications for situational awareness. In addition, there is a growing number of IBRs that provide fast frequency responses (FFR) in the form of synthetic inertia and P-f droop. It is desirable to quantify the contribution of these FFR controls as equivalent inertia. This paper proposes a probing-based inertia estimation method using a PV-battery hybrid power plant in the Kauai island power system. The method is validated under different operating conditions.

hybrid power plant↗