Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrasonic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

On the ultrasonic holography

The development of a system of ultrasonic holography is discussed. The limitations of the acousto-optical transformers, the scanning method, and the Pohlman cell are analyzed. The application of the free liquid surface deformation method is emphasized. The test equipment required for the liquid surface deformation method is described. An illustration of a typical test installation is provided.

Zieniuk, J. K.↗

Interferometric methods for measurement of ultrasonic wave velocity: Classification, characteristics and basic defects

Interferometric methods may be considered to include all methods in which the time necessary for a signal to pass through a medium is determined on the basis of the period of oscillation of which the signal consists, while the distance is determined by noting the coincidence between (1) interference between the measured signal and its reflection and ultrasonic interference, or between another signal serving as a reference and electrical interference in the electronic part of the device. In general, all interferometric methods are relatively simple and permit a high degree of accuracy. Theoretically 48 different variations may be distinguished, about 30 of which are capable of practical application. For liquids, where transverse waves do not exist, the number of possible variations is limited to 40, assuming that absolute velocity measurement is desired.

Kozlowski, Z.↗

Electronic power generators for ultrasonic frequencies

The design and construction of an ultrasonic frequency electronic power generator are discussed. The principle design elements of the generator are illustrated. The generator provides an inductive load with an output power of two kilowatts and a variable output frequency in the fifteen to thirty KiloHertz range. The method of conducting the tests and the results obtained with selected materials are analyzed.

Ciovica, D.↗

The effect of ultrasonics on the strength properties of carbon steel processed by cold plastic deformation

A study was made of the influence of ultrasounds on the mechanical properties of OLT 35 carbon steel tubes cold-drawn on a plug ultrasonically activated by longitudinal waves. Experimental results indicate that: 1. The reduction in the values of the flow limit and tensile strength is proportional to the increase in acoustic energy introduced into the material subjected to deformation. 2. The diminution in influence of ultrasounds on tensile strength and flow rate that is due to an increased degree of deformation is explained by a reduction in specific density of the acoustic energy at the focus of deformation. 3. The relations calculated on the basis of the variation in the flow limit and tensile strength as a function of acoustic energy intensity was verified experimentally.

Atanasiu, N.↗

Some research concerning the cold drawing of tubes on an ultrasonically activated plug

The results are discussed of studies of the influence of macrosounds on a metal's friction and deformation conditions at the focus of deformation, on the mechanical characteristics of cold-drawn tubes, and on the dynamic stability of the focus of deformation. In the course of these studies, experimental equipment was developed and perfected. Under the proposed conditions the cold drawing of tubes on an ultrasonically activated plug turned out to be viable and efficient.

Dragan, O.↗

Ultrasonic velocity and adiabatic compressibility in dioxane-water mixtures

Using a method of diffraction of light on an ultrasonic beam, the velocity of ultrasounds and the adiabatic compressibility in dioxane-water mixtures were determined. The dependence of these quantities on the temperature (in the 15-50 C range) and on the concentration (0-100%) were studied. For each temperature there was found a velocity maximum and a compressibility minimum for a given value of the dioxane concentration. The different behavior of these mixtures is due to intense interactions between the molecules of the two liquids composing the mixture.

Ciupe, A.↗

New experimental contributions to understanding the effect of ultrasonic irradiation on tomatoes

Irradiation of Aurora 100 tomatoes by a hydrodynamic ultrasonic generator with a frequency of 25 kHz per sec intensifies seed germination and the growth of the plants, causing precosity and increasing the output by 15.63 to 37.65%. The most effective radiation time (between 20 and 40 min) intensifies the phenophases. It causes some increase in output and changes in the chemical compositions of the fruits.

Elena, A.↗

Ultrasonic dispersion (delta V/V) determined from mechanical resonance frequency shifts

With standing wave ultrasonic techniques, small changes in phase velocity which result from changes in some external parameter (e.g., temperature or magnetic field) have traditionally been determined by observing shifts in the mechanical resonance frequency of a composite resonator. Some previous investigators have assumed that the fractional change in velocity is equal to the fractional change in frequency. Substantially improved formulas for determining the dispersion are presented and one of these is shown to be much more accurate than all previous approximations. The results of simulated and actual experiments over wide ranges of dispersion, transducer loading parameter, and frequency are analyzed in order to compare the errors inherent in the various approximations.

Moerner, W. E.↗

Development of ultrasonic methods of hemodynamic measurements

A pulsed ultrasonic Doppler velocity meter which can be used (by modifying transducers) as a flowmeter for blood circulation was experimentally studied. Calculations and profiles of turbulent and laminar flow within blood vessels are shown. Graphs and charts of transducers are included.

Histand, M. B.↗

A new ultrasonic imaging system using time delay spectrometry

A new method of forming a visual image by ultrasound is described. A shadowgraphic transmission image similar to an X-ray radiograph is produced by the application of a technique known as Time Delay Spectrometry. The system uses a repetitive frequency sweep with a linear relationship between frequency and time and the transmitting and receiving crystal are scanned in raster fashion about the subject. By electronic processing, an image may be built up which represents the energy transmitted through the specimen with a given time delay. An intensity modulated picture encompassing the full shades-of-gray capability of the recording system can be produced. A second type of image showing transmission time through the specimen may also be formed. Brightness changes in the displayed image in this case correspond to changes in the ultrasonic transmission time through the specimen.

Heyser, R. C.↗

Ultrasonic dispersion determined from mechanical resonance frequency shifts

With standing wave ultrasonic techniques, small changes in phase velocity which result from changes in some external parameter (e.g., temperature or magnetic field) have traditionally been determined by observing shifts in the mechanical resonance frequency of a composite resonator. Some previous investigators have assumed that the fractional change in velocity is equal to the fractional change in frequency. We discuss quantitatively the errors involved in such an approach, showing that it leads to substantial inaccuracies when the loading effect of the transducer(s) cannot be neglected. Substantially improved formulas for determining the dispersion are presented and one of these is shown to be much more accurate than all previous approximations. The results of simulated and actual experiments over wide ranges of dispersion, transducer loading parameter, and frequency are analyzed in order to compare the errors inherent in the various approximations.

Moerner, W. E.↗

Ultrasonic attenuation - Q measurements on 70215,29

Ultrasonic attenuation measurements have been made on an aluminum alloy, obsidian, and rock samples including lunar sample 70215,29. The measurement technique is based on a combination of the pulse transmission method and the forced resonance method. The technique is designed to explore the problem of defining experimentally, the Q of a medium or sample in which mode conversion may occur. If modes are coupled, the measured attenuation is strongly dependent on individual modes of vibration, and a range of Q-factors may be measured over various resonances or from various portions of a transient signal. On 70215,29, measurements were made over a period of a month while the sample outgassed in hard varuum. During this period, the highest measured Q of this sample increased from a few hundred into the range of 1000-1300.

Warren, N.↗

Diagnostic accuracy of an ultrasonic multiple transducer cardiac imaging system

An ultrasonic multiple-transducer imaging system for intracardiac structure visualization is developed in order to simplify visualization of the human heart in vivo without radiation hazard or invasion of the body. Results of the evaluation of the diagnostic accuracy of the devised system in a clinical setting for adult patients are presented and discussed. Criteria are presented for recognition of mitral valva prolapse, mitral stenosis, pericardial effusion, atrial septal defect, and left ventricular dyssynergy. The probable cause for false-positive and false-negative diagnoses is discussed. However, hypertrophic myopathy and congestive myopathy were unable to be detected. Since only qualitative criteria were used, it was not possible to differentiate patients with left ventricular volume overload from patients without cardiac pathology.

Popp, R. L.↗

Ultrasonic monitoring of crack extension

System consisting of commerical ultrasonic flaw detector with transducer clamped to specimen and x-yy' recorder provides permanent record of crack extension, resulting in clear indication of onset of cracking that is relatively insensitive to plastic deformation.

Kliman, S. J.↗