Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Towards searches for heavy neutral leptons with the Short-Baseline Near Detector experiment

Heavy Neutral Leptons (HNLs) are hypothetical long-lived particles that extend the Standard Model and provide a natural explanation for the origin of neutrino masses, the generation of the baryon asymmetry through leptogenesis, and the nature of dark matter. The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber located 110 m away from the Booster Neutrino Beam (BNB) target at Fermilab (Illinois, USA). The close location to the BNB origin makes the experiment sensitive to HNLs produced from meson decays in the beam. These heavy particles arrive at the detector later than neutrinos and decay into observable final states such as 𝜈e+e- or 𝜈π0, generating isolated electromagnetic showers. Thanks to SBND’s advanced scintillation light detection system, a timing resolution at the nanosecond level further boosts the experiment capabilities. In this poster, we present ongoing reconstruction efforts towards HNLs as well as expected sensitivities factoring in the reconstruction improvements.

Romeo Araujo, Jorge [Madrid, CIEMAT]↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

Reconstruction of events recorded with the surface detector of the Pierre Auger Observatory

Cosmic rays arriving at Earth collide with the upper parts of the atmosphere, thereby inducing extensive air showers. When secondary particles from the cascade arrive at the ground, they are measured by surface detector arrays. We describe the methods applied to the measurements of the surface detector of the Pierre Auger Observatory to reconstruct events with zenith angles less than $60^\circ$ using the timing and signal information recorded using the water-Cherenkov detector stations. In addition, we assess the accuracy of these methods in reconstructing the arrival directions of the primary cosmic ray particles and the sizes of the induced showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesizing pseudo-Kossel lines from neutron transmission data. II. Validation with neutron diffraction data

A new method to recover the orientation matrix of a single crystal with a known unit cell by analyzing synthesized pseudo-Kossel lines from time-of-flight neutron transmission data has been outlined in a companion article [Dessieux et al. (2023). J. Appl. Cryst. 56, https://dx.doi.org/10.1107/S1600576723001346; referred to here as Article I]. In this work, validation of this new technique is presented by employing experimental neutron transmission and diffraction measurements performed on two copper single-crystal specimens. Time-of-flight spectra were recorded during rotation (ω) of the single crystals about a vertical axis perpendicular to the incident neutron beam. The λ–ω maps recorded in transmission are utilized to determine the crystal orientation with respect to the neutron beam, following the procedure presented in Article I. Further, to validate the indexing procedure, the crystal orientations are compared with those obtained via conventional methods using the diffraction data. The resulting pseudo-Kossel lines across the 2D detectors are also observed for the first time.

36 MATERIALS SCIENCE↗

Scalar Co-SIMP dark matter: models and sensitivities

In this work, we present UV completions of the recently proposed number-changing Co-SIMP freeze-out mechanism. In contrast to the standard cannibalistic-type dark matter picture that occurs entirely in the dark sector, the 3 → 2 process setting the relic abundance in this case requires one Standard Model particle in the initial and final states. This prevents the dark sector from overheating and leads to rich experimental signatures. We generate the Co-SIMP interaction with a dark sector consisting of two scalars, with the mediator coupling to either nucleons or electrons. In either case, the dark matter candidate is naturally light : nucleophilic interactions favor the sub-GeV mass range and leptophilic interactions favor the sub-MeV mass range. Viable thermal models in these lighter mass regimes are particularly intriguing to study at this time, as new developments in low-threshold detector technologies will begin probing this region of parameter space. While particles in the sub-MeV regime can potentially impact light element formation and CMB decoupling, we show that a late-time phase transition opens up large fractions of parameter space. These thermal light dark matter models can instead be tested with dedicated experiments. We discuss the viable parameter space in each scenario in light of the current sensitivity of various experimental probes and projected future reach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shortwave Spectrometer (SWS) zenith radiance swsrad.b1 v3 and higher

Hyperspectral zenith radiances from the SWS instrument reported at 1 Hz. This data stream contains calibrated, dark-subtracted, radiances from two grating array spectrometers: a Si-detector based spectrometer denoted by SW and an InGaAs based detector denoted by LW. Spectra from both spectrometers are calibrated based on the spectral responsivity determined by reference against NIST-traceable light sources are reported independently as separate arrays having the same time record but wavelength dimension specified for each detector. Because the LW spectrometer is more susceptible to temperature-induced changes, a scale factor adjustment is applied the the LW spectra to yield agreement with the SW spectra over the wavelength range where they overlap. The final radiances incorporate QC to flag saturated values, periods where house-keeping fields fall outside acceptable bounds, and to flag pixels for which the spectral responsivity is not acceptable.

54 ENVIRONMENTAL SCIENCES↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Performance Pd/4H-SiC Epitaxial Schottky Barrier Radiation Detectors for Harsh Environment Applications

Although many refractory metals have been investigated as the choice of contact metal in 4H-SiC devices, palladium (Pd) as a Schottky barrier contact for 4H-SiC radiation detectors for harsh environment applications has not been investigated adequately. Pd is a refractory metal with high material weight-to-thickness ratio and a work function as high as nickel, one of the conventional metal contacts for high performing 4H-SiC Schottky barrier detectors (SBDs). In this article, Pd/4H-SiC epitaxial SBDs have been demonstrated for the first time as a superior self-biased (0 V applied bias) radiation detector when compared to benchmark Ni/4H-SiC SBDs. The Pd/4H-SiC SBD radiation detectors showed a very high energy resolution of 1.9% and 0.49% under self- and optimized bias, respectively, for 5486 keV alpha particles. The SBDs demonstrated a built-in voltage (V bi ) of 2.03 V and a hole diffusion length (L d ) of 30.8 µm. Such high V bi and L d led to an excellent charge collection efficiency of 76% in the self-biased mode. Capacitance mode deep level transient spectroscopy (DLTS) results revealed that the “lifetime-killer” Z 1/2 trap centers were present in the 4H-SiC epilayer. Another deep level trap was located at 1.09 eV below the conduction band minimum and resembles the EH5 trap with a concentration of 1.98 × 10 11 cm –3 and capture cross-section 1.7 × 10 –17 cm –2 ; however, the detector performance was found to be limited by charge trapping in the Z 1/2 center. The results presented in this article revealed the unexplored potential of a wide bandgap semiconductor, SiC, as high-efficiency self-biased radiation detectors. Such high performance self-biased radiation detectors are poised to address the longstanding problem of designing self-powered sensor devices for harsh environment applications e.g., advanced nuclear reactors and deep space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background studies and normalization of signal events in the Mu2e experiment

The Mu2e experiment is currently being constructed at Fermilab to search for the neutrino-less conversion of negative muons into electrons in the field of an aluminum nucleus. The experiment aims at a sensitivity of four orders of magnitude higher than previous related experiments, which implies highly demanding accuracy requirements both in the design and during the operation. To achieve such a goal, two important tasks should be accomplished. First, it is essential to estimate precisely the particle yields and all the backgrounds that could mimic the monoenergetic conversion electron signal. Second, it is necessary to normalize the signal events accurately. The normalization of the signal events is planned to be done using a detector system made of an HPGe detector and a Lanthanum Bromide detector, which will measure the rate of muons stopped on the aluminum target by looking at the emitted characteristic X-and γ-rays of energies up to 1809 keV. Therefore, it is essential to evaluate the detector system's performance before the start of the actual experiment. In this study, the first task was addressed by an extensive campaign of Monte Carlo simulations to investigate the relevant parameters and their impact on the experiment's sensitivity. The second task was handled by taking advantage of the Helmholtz-Zentrum Dresden-Rossendorf (HZDR) pulsed Bremsstrahlung photon beam at the ELBE facility. The detector system was tested at the ELBE facility under timing and background conditions similar to the ones expected at the Mu2e experiment. The study presents and discusses the simulation results and the detector system testing campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Scheme for stabilising the phase and arrival time of ultrashort laser pulses in a coherent beam combining fibre system

An algorithm has been demonstrated for simultaneously measuring the phase and arrival time of optical pulses relative to pulses in a reference channel using one detector array. Based on this algorithm, a simple optoelectronic pulse phase and arrival time stabilisation scheme has been designed for operation in a coherent beam combining fibre system for ultrashort pulses (including chirped ones). We have studied the performance of the stabilisation scheme. In particular, we have reached a phase measurement rate of 25 000 cps, demonstrated an ∼ 2 kHz limiting phase stabilisation frequency in a feedback loop, and obtained an arrival time measurement accuracy of ∼ 5 % of the transform-limited pulse duration at a measurement rate of 5 cps. In experiments concerned with coherent beam combining for two channels of a pulsed fibre system at a wavelength of 1030 nm, we have demonstrated phase stabilisation with an accuracy better than λ/100 and delay setting accuracy of 10 fs at a transform-limited pulse duration of ∼ 200 fs and obtained 94 % beam combining efficiency. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CMS Outer Tracker Module QA

The High Luminosity Large Hadron Collider is a planned upgrade to the LHC that will allow it to take up to 7 times as much data. Upgrades to all detector systems, including the Outer Tracker, are necessary to allow them to handle the increased radiation and pileup. Fermilab has been tasked with assembling modules for the Outer Tracker system. This presentation discusses the QA tests performed on these modules and the integration procedure required to ensure all modules work in sync. The QA tests include sensor IV curves, MaPSA testing, visual inspection, skeleton testing, and module testing. There are additional tests that can only be performed on integrated modules that are working in sync, and developing an understanding of the timing and latency of the modules is necessary to perform this synchronization.

Hobbeheydar, Samuel [Fermilab; Carnegie Mellon U. ↗

CMS Outer Tracker Module QA

The High Luminosity Large Hadron Collider is a planned upgrade to the LHC that will allow it to take up to 7 times as much data. Upgrades to all detector systems, including the Outer Tracker, are necessary to allow them to handle the increased radiation and pileup. Fermilab has been tasked with assembling modules for the Outer Tracker system. This presentation discusses the QA tests performed on these modules and the integration procedure required to ensure all modules work in sync. The QA tests include sensor IV curves, MaPSA testing, visual inspection, skeleton testing, and module testing. There are additional tests that can only be performed on integrated modules that are working in sync, and developing an understanding of the timing and latency of the modules is necessary to perform this synchronization.

Hobbeheydar, Samuel [Fermilab; Carnegie Mellon U. ↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Performance and long-term stability of the ICARUS-T600 scintillation light detection system

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \sim 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. Long-term behavior of PMT gains and timing resolution, demonstrate the robustness and reliability of the ICARUS scintillation light detection system and provide valuable input for the design and operation of future large-scale liquid argon detectors.

Raselli, Gian Luca [INFN, Perugia] (ORCID:00000002↗

Excellent Timing Cherenkov Light Detection for Dual-readout High-granularity Calorimetry

We are developing a Cherenkov detector aiming for applications in the next-generation calorimetry. It is a calorimetry that combines dual-readout and high-granularity with excellent timing capability. This work is to prove the concept of the Cherenkov detector utilizing a resistive plate chamber (RPC) with Diamond-Like Carbon as resistive electrode. The first prototype was tested with β-rays and cosmic-rays. This paper discusses the behavior of the charge spectrum and the time resolution of the first prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗