Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Test-Derived Effective Emittance for Cassini MLI Blankets and Heat Loss Characteristics in the Vicinity of Seams

Thermal performance of Cassini MLI blankets was characterized in thermal vacuum tests. Effective emittance was derived for the standard and high-temperature layups, with or without micrometeoroid protection standoffs, and for a high-performance duo-layup with staggered seams. The all-Kapton layup wa shown to have a 19% higher effective emittance than the hybrid Kapton-Mylar layup, and the duo-layup exhibited a dramatic capability of reducing heat dissipation by 2.6 fold. Several different definitions of effective emittance are discussed, and their relations to distinct hardware-MLI configurations and corresponding modeling techniques clarified. Large temperature differences (up to 70 C) were observed between the center and seam of a blanket. Heat losses in the vicinity of seams are qualified, and a major MLI heat loss mechanism elucidated.

Cassini↗

Application of the CINGEN program a thermal network data generator

The application of the CINGEN computer program and two of its supporting programs for the evaluation of structural and thermal performance of physical systems was described. The CINGEN program was written and implemented to avoid the duplication effort of performing a finite element approach for structural analysis and a finite differencing technique for thermal analysis, as well as the desire for a geometrical representation of the thermal model to reduce modeling errors. The program simplifies the thermal modeling process by performing all of the capacitance and conductance calculations normally done by the analyst. Each solid element is divided into five tetrahedrons, allowing the total volume to be calculated precisely. A sample problem was illustrated.

Shultz, W. E.↗

Improving thermal and electrochemical performances of LiCoO{sub 2} cathode at high cut-off charge potentials by MF{sub 3} (M=Ce, Al) coating

Highlights: • Fluoride metal is successfully coated on the surface of LiCoO{sub 2}. • Easy and scalable method is adopted for the synthesis of coated-LiCoO{sub 2}. • Appropriate amount of AlF{sub 3} or CeF{sub 3} is beneficial to reduce cation disorder. • The electrochemical performances of coated LiCoO{sub 2} is significantly enhanced at higher potential (cycling efficiency and reversible capacity). • The coated cathode exhibits excellent thermal stability highlighted by calorimetric technique. - Abstract: Surface coating of LiCoO{sub 2} remained one of the efficient methods to enhance its electrochemical and thermal performances, especially at high cut-off potential. In this work, MF{sub 3} (M = Ce, Al) coated LiCoO{sub 2} was synthesized via co-precipitation method followed by a solid state reaction at 400 °C. The morphology and structure of the modified cathode material were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the fluoride compound MF{sub 3} is successfully coated on the surface of LiCoO{sub 2} cathode particles with an average layer thickness about 12 nm and 40 nm for AlF{sub 3} and CeF{sub 3}, respectively. The electrochemical tests show that the AlF{sub 3}-coating layer significantly enhances the cycling performance of LiCoO{sub 2} cathode material, even at high cut-off potential. While the bare LiCoO{sub 2} cathode displays fast fading at 4.6 V vs. Li{sup +}/Li cutoff potential, the surface-modified electrode exhibits the great capacity of 160 mAh g{sup −1} with excellent capacity retention on several cycles. We concluded that the electrochemical and the thermal enhancement at high potential are ascribed to the presence of MF{sub 3} coating layer which prevent the side reaction during the charge discharge process, alleviate the attack by the acidic electrolyte and reduce the damage of electrode structure.

36 MATERIALS SCIENCE↗

Compact Heat Exchanger Design and Testing for Advanced Reactors and Advanced Power Cycles

The goal of the proposed research is to demonstrate the thermal hydraulic performance of innovative surface geometries in compact heat exchangers used as intermediate heat exchangers (IHXs) and recuperators for the supercritical carbon dioxide (s-CO 2 ) Brayton cycle. Printed-circuit heat exchangers (PCHEs) are the primary compact heat exchangers of interest. The overall objectives are: To develop optimized PCHE designs for different working fluid combinations including helium to s-CO 2 , liquid salt to s-CO 2 , sodium to s-CO 2 , and liquid salt to helium; To experimentally and numerically investigate thermal performance, thermal stress and failure mechanism of PCHEs under various transients; and To study diffusion bonding techniques for elevated-temperature alloys and examine post-test material integrity of the PCHEs. The project objectives were accomplished by defining and executing five different tasks corresponding to these specific objectives. The first task involved a thorough literature review and a selection of IHX candidates with different surface geometries as well as a summary of prototypic operational conditions. The second task involved optimization of PCHE design with numerical analyses of thermal-hydraulic performances and mechanical integrity. The subsequent task dealt with the development of testing facilities and engineering design of PCHE to be tested in s-CO 2 fluid conditions. The next task involved experimental investigation and validation of the thermal-hydraulic performances and thermal stress distribution of prototype PCHEs manufactured with particular surface geometries. The last task involved an investigation of diffusion bonding process and posttest destructive testing to validate mechanical design methods adopted in the design process. The experimental work utilized the two test facilities at The Ohio State University (OSU) including one existing High-Temperature Helium Test Facility (HTHF) and the newly developed s-CO 2 test loop (STL) facility and s-CO 2 test facility at University of Wisconsin – Madison (UW).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measure Guideline: Internal Insulation of Masonry Walls

This measure guideline provides recommendations for interior insulation assemblies that control interstitial condensation and durability risks; recommendations for acceptable thermal performance are also provided. An illustrated guide of high-risk exterior details (which concentrate bulk water), and recommended remediation details is provided. This is followed by a recommended methodology for risk assessment of a masonry interior insulation project: a series of steps are suggested to assess the risks associated with this retrofit, with greater certainty with added steps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spacelab carrier complement thermal design and performance

The present discussion of the Spacelab carrier complement, which encompasses a Module Carrier, a Module-Pallet Carrier, and a Multiplexer/Demultiplexer Pallet, gives attention to both active and passive thermal performance capabilities, and presents ground testing and analytical results obtained to date. An account is given of the prospective use of a Spacelab Multipurpose Experiment Support Structure.

Bancroft, S.↗

Solar energy system performance evaluation: Seasonal report for SEMCO, Loxahatchee, Florida

The operational and thermal performance of a variety of solar systems installed in operational test sites are described. The analysis used is based on instrumented system data monitored and collected for at least one full season of operation. The long-term field performance of the installed system and the technical contributions to the definition of techniques and requirements solar energy system design are analyzed. The solar energy system was designed to supply domestic hot water for a family of four, single-family residences. It consists of two liquid flat plate collectors, single tank, controls, and transport lines.

Source record↗

Solar energy system performance evaluation: Seasonal report for fern, Tunkhannock, Pennsylvania

The operational and thermal performance of a variety of solar systems installed in operational test sites are described. The analysis is based on instrumented system data monitored and collected for at least one full season of operation. The long-term field performance of the installed system is reported, and technical contributions to the definition of techniques and requirements for solar energy system design are made. The solar energy system was designed to supply space heating and domestic hot water for single-family residences. The system consists of air flat plate collectors, storage tank, pumps, heat exchangers, associated plumbing, and controls.

Source record↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Solar energy system performance evaluaton: Seasonal report for Solaron-Akron, Akron, Ohio

The operational and thermal performance of the solar energy system by Solaron Corporation is described. The system was designed to provide an 1940 square foot floor area with space heating and domestic hot water for a dual-level single family residence in Akron, Ohio. The solar energy system uses air as the heat transport medium, has a 546 square foot flat plate collector array subsystem, a 270 cubic foot rock thermal storage bin subsystem, a domestic hot water preheat tank, pumps, controls and transport lines. In general, the performance of the Solaron Akron solar energy system was somewhat difficult to assess for the November 1978 through October 1979 time period. The problems relating to the control systems, various solar energy leakages, air flow correction factors and instrumentation cause a significant amount of subjectivity to be involved in the performance assessment for this solar energy system. Had these problems not been present, it is felt that this system would have exhibited a resonably high level of measured performance.

Source record↗

ASSEMBLY, INSTALLATION, AND COMMISSIONING OF THE ATLAS UPGRADE CRYOMODULE

A new cryomodule containing seven low-beta superconducting radio frequency (SRF) cavities has been added to the ATLAS heavy ion linac, providing an additional 15 MV accelerating potential to the existing accelerator. We describe the final stages of cryomodule assembly, commissioning, and installation in the ATLAS accelerator. The clean techniques used to achieve low-particulate rf surfaces are presented, as are the module design features which enable clean assembly and reliable high-gradient operation. The thermal performance of the cryomodule is described, along with performance data for the SRF cavities. Details on subsystem performance including helium and nitrogen systems, vacuum systems, thermal and magnetic shields, slow and fast tuners, and survey/alignment systems are given.

43 PARTICLE ACCELERATORS↗

DOE-Managed HLW and SNF Research: FY15 EBS and Thermal Analysis Work Package Status.

This report examines the technical elements necessary to evaluate EBS concepts and perform thermal analysis of DOE-Managed SNF and HLW in the disposal settings of primary interest – argillite, crystalline, salt, and deep borehole. As the disposal design concept is composed of waste inventory, geologic setting, and engineered concept of operation, the engineered barrier system (EBS) falls into the last component of engineered concept of operation. The waste inventory for DOE-Managed HLW and SNF is closely examined, with specific attention to the number of waste packages, the size of waste packages, and the thermal output per package. As expected, the DOE-Managed HLW and SNF inventory has a much smaller volume, and hence smaller number of canisters, as well a lower thermal output, relative to a waste inventory that would include commercial spent nuclear fuel (CSNF). A survey of available data and methods from previous studies of thermal analysis indicates that, in some cases, thermo-hydrologic modeling will be necessary to appropriately address the problem. This report also outlines scope for FY16 work -- a key challenge identified is developing a methodology to effectively and efficiently evaluate EBS performance in each disposal setting on the basis of thermal analyses results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Cellular Shades in the PNNL Lab Homes

This report examines the energy performance of cellular shade window coverings in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The 1500-square-foot homes were identical in construction and baseline performance, which allowed any difference in energy and thermal performance between the baseline home and the experimental home to be attributed to the retrofit technology installed in the experimental home. To assess the performance of high efficiency window attachments in a residential retrofit application, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2015 -2016 winter heating and summer cooling seasons. Hunter Douglas Duette® Architella® Trielle™ opaque honeycomb “cellular” shades were installed over double-pane clear-glass, aluminum-frame primary windows in the experimental home and were compared to identical primary windows with no window coverings and with standard typical white vinyl horizontal blind window coverings in the baseline home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Analysis for the Carbon Fiber Composite Support Structure for Layer 0 of the D0 Silicon Micro Tracker

The support structures for the new Layer 0 (Figures 1, 2, 3) of the Run 2b silicon tracker in D0 were designed and fabricated at the University of Washington. These structures were required to have minimum mass, yet be very rigid so as to meet the high precision requirements placed on the position of the silicon detector chips. They also have to provide for cooling to remove the heat generated by the sensors and signal processing electronics and to keep the sensors at the desired operating temperature (below -5 C). All of these requirements were best met by carbon fiber/epoxy composite technology. State of the art carbon fiber materials have extremely high Young's moduli and high thermal conductivity. Appropriate fiber lay-ups and fabrication methods have been developed and used successfully to produce both various prototype structures and the structures used in the production Layer 0. The geometry of these structures was determined mainly by the geometry of the sensors themselves. The structures incorporated a complete cooling system consisting of extruded PEEK coolant tubes and distribution manifolds made from carbon fiber composites. In order to determine the mechanical and thermal performance of the structures, detailed FEA analyses of L0 have been carried out and are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apollo experience report: Thermal design of Apollo lunar surface experiments package

The evolution of the thermal design of the Apollo lunar surface experiments package central station from the basic concept to the final flight hardware is discussed, including results of development, prototype, and qualification tests that were used to verify that the flight hardware would operate adequately on the lunar surface. In addition, brief discussions of the thermal design of experiments included in the experiments package are presented. The flight thermal performance is compared with analytical results and thermal-vacuum test results, and design modifications for future lunar surface experiment packages are presented.

Harris, R. S., Jr.↗

Two phase capillary pumped heat transfer in the Instrument Thermal Test Bed

An experimental study of the thermal performance of two evaporators installed in the Instrument Thermal Test Bed (ITTB) was conducted. The ITTB was operated as a capillary pumped loop (CPL) with a transport length of approximately 12 meters. Empirical determinations of a general start up procedure, overall heat transfer coefficient, and minimum operating power were accomplished for each evaporator. Additionally, a detailed thermal model was developed for the High Power Spacecraft Thermal Management (HPSTM) evaporator and validated.

Didion, Jeffrey R.↗

Transient Thermal Analysis of the 12.5 KW HERMeS Hall Thruster

NASA’s Dawn spacecraft entered orbit around the dwarf planet Ceres on March 6, 2015 thereby becoming the first mission to orbit two celestial bodies outside of the Earth-moon system. This feat was made possible due to the use of electric propulsion (EP) to provide the 11 km/s of delta-V that was necessary. This type of propulsion is also enabling for many of NASA’s future missions, such as the proposed Asteroid Redirect Robotic Mission (ARRM). Specifically, the Hall Effect Rocket with Magnetic Shielding (HERMeS) is the propulsive design baseline due to its long operational lifetime and high specific impulse. Extensive modeling is required to verify the thruster's predicted thermal performance and survival during the bounding mission phases. Since the thruster would constrain plasma on the order of tens of thousands of hours, components in the thruster must be able to accommodate much higher sustained temperatures than typical spacecraft hardware. Furthermore, the high temperatures necessitate care in analyzing thermal gradients within the thruster. In this paper, we describe a thermal model of the HERMeS thruster and focus upon the thruster's transient performance under different initial firing conditions. The thruster's transient thermal response is critical to verify margin in the thermal stresses inherent in the thruster and to determine safe start-up procedures to protect the thruster's critical components. This model is used to perform transient thermal analysis of the thruster during startup and shutdown, provide temperature maps for structural analysis, and plan for thermal cycle testing conducted at JPL. The thermal cycle testing includes thruster starts at the cold temperature limits and operation at maximum expected external heat flux. This work will support laboratory environmental testing of the HERMeS thruster, which is being conducted at JPL in 2016.

Reilly, Sean↗

Performance Testing of Thermal Interface Filler Materials in a Bolted Aluminum Interface Under Thermal/Vacuum Conditions

A thermal interface material is one of the many tools often used as part of the thermal control scheme for space-based applications. Historically, at Marshall Space Flight Center, CHO-THERM 1671 has primarily been used for applications where an interface material was deemed necessary. However, numerous alternatives have come on the market in recent years. It was decided that a number of these materials should be tested against each other to see if there were better performing alternatives. The tests were done strictly to compare the thermal performance of the materials relative to each other under repeatable conditions and do not take into consideration other design issues, such as off-gassing, electrical conduction, isolation, etc. The purpose of this Technical Memorandum is to detail the materials tested, test apparatus, procedures, and results of these tests. The results show that there are a number of better performing alternatives now available.

Glasgow, S. D.↗