Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Theory, observations, and simulations of kinetic entropy in a magnetotail electron diffusion region

In this work, we examine velocity-space kinetic entropy, a spatially local measure of entropy for systems out of thermal equilibrium, during an encounter of an electron diffusion region at a magnetic reconnection site in Earth’s magnetotail by the Magnetospheric Multiscale (MMS) mission. We start by generalizing the theory of kinetic entropy to the case of non-uniform velocity space grids and transforming the equations into spheri- cal energy coordinates useful to experimental plasma detectors. The theory is then applied to MMS data and compared to particle-in-cell simulations of reconnection. We demonstrate that the entropy-based non-Maxwellianity measure from the MMS data is of sufficiently high precision to reliably identify non-Maxwellian distributions and therefore the measurements when kinetic effects are most significant. By comparing two different non-Maxwellian measures, we show that total entropy density suffers from “information loss” because it lacks a dependence on the velocity space grid, and so has lost information about how well a distribution function is resolved. Local velocity-space kinetic entropy density recovers this information. We quantify information loss and argue that the considerations needed to minimize it are crucial for instruments designed to measure distribution functions in situ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncertainty analysis of steady-state measurements with a hot-filament type calorimetric emissometer

Calorimetric emissometers measure total hemispherical emissivity by measuring the heat transferred from a heated sample to its surroundings under a vacuum. The accuracy of emissometers standardized by the ASTM C835-06 are well understood. This work uses the Guide to the Evaluation of Uncertainty in Measurement (GUM) for the propagation uncertainties for an ASTM compliant emissometer. The GUM method was able to develop a measurement model and expressions to determine the uncertainty for other emissometers of this type. Data on ‘as-received’ Hastelloy X was used to develop a detailed uncertainty analysis of the emissivity measurement. Data on ‘as-received’ SS 347 and sandblasted A387 Gr. 91 and previous data by the group on A508/A533B were used to determine uncertainty over the ranges 0.16 to 0.81. For all samples, relative uncertainties in emissivities varied from 0.77% to 2.5% when using a fluxgate magnetometer sensor (FMS) to measure the DC heating current. Data on Hastelloy X using a Hall-effect sensor for DC current and low alloy steel showed the DC current and voltage across the test section to be dominate sources of uncertainty. When these sources were reduced, the specimen temperature and the surface area of the test sections were main sources of uncertainty in the emissivity, especially at higher temperatures. As thermal expansion of the surface was considered in the calculations, correlation between specimen temperature and surface area was examined. It was found to be a small contribution to emissivity's uncertainty despite the differences in linear CTE and its uncertainty for the materials analyzed in this study. For low temperatures, the chamber temperature can be a significant source of uncertainty if not sufficiently cooled. The GUM was also briefly compared to uncertainty from the 2nd and 3rd expansions of the Taylor series. We found that the results were the same when rounding to two significant figures.

42 ENGINEERING↗

Soil Sensors in Agriculture: From Unsustainable to Biodegradable

Commercially available bi-metallic temperature sensors have long exploited differential thermal expansions between materials to produce an actuation-induced readout from a bi-metal helix. When dispersed in agricultural land, electronic components are used to transmit information at the cost of an increased environmental footprint. This paper briefly recaps the proposed sensor, which employs a biodegradable bi-material helix composed of a polymer and metal. Proposed polymer sheetings of cellulose acetate and polylactic acid are characterized via TGA, DMA, and DSC to evaluate plasticizer content, shrinkage, and an appropriate sensor work-use range. Finally, the deflection of non-biodegradable bi-polymer strips is quantified for various combinations to determine if bi-polymer deflection is possible.

47 OTHER INSTRUMENTATION↗

The Effect of Membrane Casting Irregularities on Initial Fuel Cell Performance

Membrane electrode assemblies (MEA) for polymer electrolyte membrane fuel cells (PEMFC) may possess as-manufactured non-uniformities in any of its constituent components. This article studies casting irregularities located within the PEM to understand their potential impact on MEA initial performance. Membrane material was cast on a lab-scale polymer casting line operating either within or at the boundaries of the process window. The resulting membrane material was either pristine in the former case, or, in the latter case, contained air bubbles, cracks, and other irregularities, ranging in size from about 0.6 to 3 mm. Spatial polarization experiments were conducted using a 121-channel segmented fuel cell system, and thermal imaging was performed subsequently to map hydrogen crossover to spatial performance. While total-cell polarization data was minimally impacted by the irregularities, the spatial diagnostics showed local performance impacts that, in operation over time, could cause degradation in performance or earlier failure of the MEA. Such impacts could lead to these irregularities being classified as defects, i.e., manufacturing variations that should be identified and not included in a fuel cell stack. Classification of irregularities as defects will ultimately assist the industry by contributing to the development of threshold detection limits for in-line quality control diagnostics.

30 DIRECT ENERGY CONVERSION↗

A novel experimental system for the KDK measurement of the 40 K decay scheme relevant for rare event searches

Potassium-40 ( 40 K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. 40 K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpretingcertain results or can lead to lack of precision depending on the field and analysis technique. Additionally, the KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited 40 K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr 2 I 5 :Eu scintillator as source and detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pre-Symptomatic COVID Screening

Temperature checks for fever are extensively used for preliminary COVID screenings but are ineffective during the incubation stage of infection when a person is asymptotic. Researchers at the European Centre for Disease Prevention and Control concluded that approximately 75% of passengers infected with COVID-19 and traveling from affected Chinese cities would not be detected by early screening. Core body temperature is normally kept within a narrow range and has the smallest relative standard deviation of all vital signs. Heat in the body is prioritized around internal organs at the expense of the periphery by controlling blood flow. In fact, blood flow to the skin may vary by a factor of 100 depending on thermal conditions. This adaptation causes rapid temperature fluctuations in different skin regions from changes in cardiac output, metabolism, and likely cytokine diffusion during inflammation that would not be seen in average core body temperature. Current IR and thermal scanners used for temperature checks are not necessarily reflective of core body temperatures and require cautious interpretation as they frequently result in false positive and false negative diagnosis. Hand held thermometers measure average skin temperatures and can get readings that differ from core body temperature by as much as 7°. Rather than focusing on a core body temperature threshold assessment we believe that variability of temperature patterns using a novel wearable transdermal microneedle sensor will be more sensitive to infections in the incubation stage and propose to develop a wearable transdermal temperature sensor using established Sandia microneedle technology for pre-symptomatic COVID screening that can additionally be used to monitor disease progression at later stages.

47 OTHER INSTRUMENTATION↗

White Paper on Case Study of Safe Installation of Second-Life Energy Storage System

This technical report provides for a case study for the safe installation of a second-life, or repurposed, battery, that has been reconfigured for use as a stationary energy storage systems (ESS). Driven by legislative requirements such as California Senate Bill 615 and projections that retired EV batteries could meet a substantial portion of U.S. grid ESS needs beginning in 2035, the repurposing of EV batteries is anticipated to grow significantly. However, safety concerns arise from the effects of aging, unknown prior usage history, and changes in thermal runaway behavior, which may increase failure risks compared to new batteries. NFPA 855, the predominant U.S. standard for ESS installation, mandates that second-life batteries meet all requirements for new batteries, with repurposers complying with UL 1974 in addition to obtaining UL 9540 and UL 1973 listings. These are certifications that few repurposers have achieved and represent a regulatory barrier to entry for the market as a whole.

47 OTHER INSTRUMENTATION↗

Predicting deviations in ex-core detector response in Krsko NPP during an earthquake with Monte-Carlo neutron transport methods

To study the response of ex-core detectors during an earthquake, an approach using Monte Carlo code MCNP was developed. As a first step to predict the response of the ex-core detectors a detailed MCNP model of the Krsko reactor core was created. A detailed MCNP core model was used to calculate 3D power distributions inside the core. Calculated power distributions were verified by comparison to the CORD-2 calculations, which is currently used for core design calculation verification of the Krsko nuclear power plant. Due to the outside the core position of the neutron detectors, the hybrid code ADVANTG is used to generate weight windows to speed up neutron transport outside the reactor core. To be able to use ADVANTG, fixed neutron source had to be reconstructed from the criticality core calculation. It was found that the power range ex-core detector movement has a negligible effect on the value of the thermal neutron flux at the active part of the detector. However, the 5 cm radial movement of the intermediate-range detector leads to 7 % - 8 % change in thermal neutron flux within the active intermediate-range detector region. The analysis continued with the evaluation of the effect of core barrel movement on the ex-core detector response. It was determined that the 2 mm core barrel radial oscillation can lead to ∼ 4% change in thermal neutron flux within the active detector region. It was evaluated that reactor core movement inside the baffle can lead up to ∼ 1.9% and ∼ 1.3% deviation in power-range and intermediate-range detector signal respectively. Analysis showed that the mechanical movement of ex-core neutron detectors could not explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Testing of fiber optic based sensors for advanced reactors in the Texas A&M University TRIGA reactor

An Optical Fiber Based Gamma Thermometer has been developed and tested at the Texas A&M University reactor as well as the Ohio State Research Reactor. This sensor technology provides temperature measurement of a thermal mass undergoing gamma heating, from which the gamma flux along the length of the sensor may be calculated. The gamma flux data from an array of OFBGTs could allow the determination of local power density within a nuclear reactor core in three dimensions. The design of the sensor makes use of optical fiber as a truly distributed temperature sensor with a spatial resolution less than 1mm and temperature accuracy of ±1°C. The testing program showed that the system provided the expected temperature data for each location. Overall, this sensor technology shows promise for current Light Water Reactors as well as advanced nuclear reactors by providing an unparalleled level of precision in reactor power measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of a cryocooler conduction cooled superconducting radiofrequency cavity operating at practical cw accelerating gradients

Abstract We demonstrate practical accelerating gradients on a superconducting radiofrequency (SRF) accelerator cavity with cryocooler conduction cooling, a cooling technique that does not involve the complexities of the conventional liquid helium bath. A design is first presented that enables conduction cooling an elliptical-cell SRF cavity. Implementing this design, a single cell 650 MHz Nb 3 Sn cavity coupled using high purity aluminum thermal links to a 4 K pulse tube cryocooler generated accelerating gradients up to 6.6 MV m −1 at 100% duty cycle. The experiments were carried out with the cavity-cryocooler assembly in a simple vacuum vessel, completely free of circulating liquid cryogens. We anticipate that this cryocooling technique will make the SRF technology accessible to interested accelerator researchers who lack access to full-stack helium cryogenic systems. Furthermore, the technique can lead to SRF based compact sources of high average power electron beams for environmental protection and industrial applications. A concept of such an SRF compact accelerator is presented.

43 PARTICLE ACCELERATORS↗

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP↗

Mjölnir: a miniature triaxial rock deformation apparatus for 4D synchrotron X-ray microtomography

An X-ray transparent experimental triaxial rock deformation apparatus, here named 'Mjölnir', enables investigations of brittle-style rock deformation and failure, as well as coupled thermal, chemical and mechanical processes relevant to a range of Earth subsurface environments. Designed to operate with cylindrical samples up to 3.2 mm outside-diameter and up to 10 mm length, Mjölnir can attain up to 50 MPa confining pressure and in excess of 600 MPa axial load. The addition of heaters extends the experimental range to temperatures up to 140°C. Deployment of Mjolnir on synchrotron beamlines indicates that full 3D datasets may be acquired in a few seconds to a few minutes, meaning full 4D investigations of deformation processes can be undertaken. Mjölnir is constructed from readily available materials and components and complete technical drawings are included in the supporting information.

47 OTHER INSTRUMENTATION↗

Ionization-driven competitive (recovery) process in pre-damaged KTaO 3 : A brief review

The nuclear (S n ) and electronic (S e ) energy dissipation processes have been considered to be independent and largely uncorrelated, influencing our understanding of ion–solid interaction and damage processes in the last decades. Recently, however, it has become more generally accepted that S n and S e are coupled as they interact both in time and space. To decouple these processes, separating these effects in experiments using sequential dual-beam irradiations have become accepted as the logical path to advance the understanding of complex interactions between S e and pre-existing defects that may be created from displacement events. This experimental approach has been recently applied to studies of KTaO 3 to reveal new insights into this critical research topic. Here, we offer a forward-looking and comprehensive perspective on the fundamental coupling between Se and pre-existing defects in KTaO 3 . The origins behind the competitive two-stage phase transition process leading to damage healing are revealed and discussed. Furthermore, the evidence resulting from synergistic effects is also included for comparison. Additionally, our findings are rationalized using both Se and the ion velocity as key parameters. We highlight how the inelastic thermal spike (i-TS) calculations provide insights into the nature of this coupled process and further confirm that the ion velocity effect governs annealing kinetics. This work emphasizes that through the introduction of a small amount of local disorder in materials, MeV ion irradiation (i.e., not extreme S e ) may also be one additional option in subsequent material modification and functionalization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observing flow of He II with unsupervised machine learning

Abstract Time dependent observations of point-to-point correlations of the velocity vector field (structure functions) are necessary to model and understand fluid flow around complex objects. Using thermal gradients, we observed fluid flow by recording fluorescence of $${\text{He}}_{2}^{*}$$ He 2 ∗ excimers produced by neutron capture throughout a ~ cm 3 volume. Because the photon emitted by an excited excimer is unlikely to be recorded by the camera, the techniques of particle tracking (PTV) and particle imaging (PIV) velocimetry cannot be applied to extract information from the fluorescence of individual excimers. Therefore, we applied an unsupervised machine learning algorithm to identify light from ensembles of excimers (clusters) and then tracked the centroids of the clusters using a particle displacement determination algorithm developed for PTV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Verification and Validation of Two Hydrodynamic Methods for Simulations of High Energy Density Physics Problems

A 3D verification and validation suite of test problems is presented and used to evaluate hydrodynamic methods within a radiation hydrodynamics code, xRAGE. These test problems exercise different levels of complexity, building towards ICF problems which in addition to hydrodynamics also include three temperature plasma physics, thermal conduction, and radiation diffusion. Among the problems in the test suite are the Kidder ball problem, the Verney shell problem, and a 5-material compression problem, which exercise different purely hydrodynamic methods implemented within xRAGE. There is excellent agreement between 2D and 3D XRAGE simulation results and between the xRAGE results and the benchmark solutions. Two 3D ICF test problems are also presented, based on an OMEGA direct drive capsule experiment and on a NIF indirect drive capsule experiment. It is demonstrated that the newer unsplit hydrodynamic method in xRAGE produces more vorticity relative to the older default method. For the indirect drive capsule, the 3D simulations are in reasonable agreement with the experimental values of ion temperature and neutron production.

47 OTHER INSTRUMENTATION↗

High-Speed Diagnostic and Simulation Capabilities for Reacting Hypersonic Reentry Flows (LDRD Final Report)

High-enthalpy hypersonic flight represents an application space of significant concern within the current national-security landscape. The hypersonic environment is characterized by high-speed compressible fluid mechanics and complex reacting flow physics, which may present both thermal and chemical nonequilibrium effects. We report on the results of a three-year LDRD effort, funded by the Engineering Sciences Research Foundation (ESRF) investment area, which has been focused on the development and deployment of new high-speed thermochemical diagnostics capabilities for measurements in the high-enthalpy hypersonic environment posed by Sandia's free-piston shock tunnel. The project has additionally sponsored model development efforts, which have added thermal nonequilibrium modeling capabilities to Sandia codes for subsequent design of many of our shock-tunnel experiments. We have cultivated high-speed, chemically specific, laser-diagnostic approaches that are uniquely co-located with Sandia's high-enthalpy hypersonic test facilities. These tools include picosecond and nanosecond coherent anti-Stokes Raman scattering at 100-kHz rates for time-resolved thermometry, including thermal nonequilibrium conditions, and 100-kHz planar laser-induced fluorescence of nitric oxide for chemically specific imaging and velocimetry. Key results from this LDRD project have been documented in a number of journal submissions and conference proceedings, which are cited here. The body of this report is, therefore, concise and summarizes the key results of the project. The reader is directed toward these reference materials and appendices for more detailed discussions of the project results and findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRANSPORTATION CONSIDERATIONS FOR USED FUEL AND ADVANCED NUCLEAR ENERGY TECHNOLOGIES

This study focuses on requirements and challenges pertaining to advanced transportable nuclear energy systems, which are currently in development and feature varying degrees of mobility. These reactors mostly use high-assay low-enriched uranium (HALEU) fuel, and only limited refueling is required during their lifecycles. Due to the smaller source terms, higher burnup fuel, and potentially higher thermal efficiency involved, the waste inventory will be less than that generated by conventional light-water reactors. However, the relevant regulatory requirements must be met when transporting HALEU fuel (whether fresh or used) inside the reactor vessel—mainly the fuel material transportation, siting, and physical protection requirements outlined in US Nuclear Regulatory Commission (NRC) regulations 10 CFR 71 and 73. Spent nuclear fuel (SNF), as well as irradiated fuel (used during any interval of reactor operation), contains highly radioactive materials that generate heat and necessitate special precautions during transportation. This study addresses the challenges that this incurs, and outlines potential solutions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing the Performance of Fission Chambers for Local Neutron Flux and Spectrum Measurement

Three fission chambers were tested at The Ohio State University Research Reactor (OSURR) to evaluate fission chambers for neutron flux and spectrum measurements. Two of the fission chambers are commercial Photonis CFUR43 fission chambers—one utilizing highly enriched uranium-235 fissile deposits for thermal neutron detection and the other with highly depleted uranium-238 for fast neutron detection. This experiment was also performed in collaboration with French Alternative Energies and Atomic Energy Commission (CEA) with CEA suppling a uranium-235 loaded fission chamber built from the Photonis CFPR CE8/9 kit. The fission chambers were irradiated in a movable 6.5 inch dry tube at reactor powers of 50 kW, 200 kW, and 450 kW at ambient temperature and at 350°C. While all sensors demonstrated good linear sensitivity to reactor power, a leakage current of 6 nA was measured for the CFUR43 detectors. Additionally, the measured signal ratios of the two CFUR43 detectors did not match the theoretical values and are subject to further investigation on individual signal contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗