Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Automated detection of asteroids in real-time with the Spacewatch telescope

The Spacewatch telescope on Kitt Peak is being used to survey for near-earth asteroids using a Tektronix TK2048 CCD in scanning mode. We hope to identify suitable low delta v candidates amongst the near-earth asteroid population as possible exploration targets, to identify those objects which pose a danger to life on earth, and to study the physical properties of the objects in near-earth space. Between Sep. 1990 and Jun. 1991, 14 new earth-approaching asteroids including 1 Aten, 9 Apollo, and 4 Amor type asteroids were detected by automated software and discriminated by their angular rates from the rest of the detected asteroids in near-real time by the observer. The average of about 1.5 earth-approaching asteroids per month is comparable to the total number found by all other observatories combined. One other Apollo type asteroid was detected by the observer as a long trailed image. The positions of this last object were measured and the object was tracked by the observer in real time. This object was determined to be a 5-10 meter diameter object which passed within 170,000 kilometers of earth. Of the 14 automatically detected earth-approaching asteroids, 10 have been found at distances in excess of 0.5 AU from earth. An average of more than 2000 asteroids are detected each month. Positions, angular rates, and brightnesses are determined for each of these asteroids in real-time.

Scotti, James Vernon↗

An optical motion measuring system for laterally oscillated fatigue tests

This paper describes an optical system developed for materials testing laboratories at NASA Langley Research Center (LaRC) for high resolution monitoring of the transverse displacement and angular rotation of a test specimen installed in an axial-tension bending machine (ATB) during fatigue tests. It consists of a small laser, optics, a motorized mirror, three photodiodes, electronic detection and counting circuits, a data acquisition system, and a personal computer. A 3-inch by 5-inch rectangular plate attached to the upper grip of the test machine serves as a target base for the optical system. The personal computer automates the fatigue test procedure, controls data acquisition, performs data reduction, and provides user displays. The data acquisition system also monitors signals from up to 16 strain gages mounted on the test specimen. The motion measuring system is designed to continuously monitor and correlate the amplitude of the oscillatory motion with the strain gage signals in order to detect the onset of failure of the composite test specimen. A prototype system has been developed and tested which exceeds the design specifications of +/- 0.01 inch displacement accuracy, and +/- 0.25 deg angular accuracy at a sampling rate of 100 samples per second.

Tripp, John S.↗

Hydrogen Sensor via Plasma Techniques Development

Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH 2 ) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment. * Work supported by NASA Kennedy Space Center’s Science Mission Directorate Innovative Research and Development Fund.

Plasma↗

Hydrogen Sensor via Plasma Techniques Development

Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH2) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment.

plasma↗

Multiple-Beam Detection of Fast Transient Radio Sources

A method has been designed for using multiple independent stations to discriminate fast transient radio sources from local anomalies, such as antenna noise or radio frequency interference (RFI). This can improve the sensitivity of incoherent detection for geographically separated stations such as the very long baseline array (VLBA), the future square kilometer array (SKA), or any other coincident observations by multiple separated receivers. The transients are short, broadband pulses of radio energy, often just a few milliseconds long, emitted by a variety of exotic astronomical phenomena. They generally represent rare, high-energy events making them of great scientific value. For RFI-robust adaptive detection of transients, using multiple stations, a family of algorithms has been developed. The technique exploits the fact that the separated stations constitute statistically independent samples of the target. This can be used to adaptively ignore RFI events for superior sensitivity. If the antenna signals are independent and identically distributed (IID), then RFI events are simply outlier data points that can be removed through robust estimation such as a trimmed or Winsorized estimator. The alternative "trimmed" estimator is considered, which excises the strongest n signals from the list of short-beamed intensities. Because local RFI is independent at each antenna, this interference is unlikely to occur at many antennas on the same step. Trimming the strongest signals provides robustness to RFI that can theoretically outperform even the detection performance of the same number of antennas at a single site. This algorithm requires sorting the signals at each time step and dispersion measure, an operation that is computationally tractable for existing array sizes. An alternative uses the various stations to form an ensemble estimate of the conditional density function (CDF) evaluated at each time step. Both methods outperform standard detection strategies on a test sequence of VLBA data, and both are efficient enough for deployment in real-time, online transient detection applications.

Thompson, David R.↗

Three New Brown Dwarfs and A Massive Hot Jupiter Revealed By TESS Around Early-Type Stars

Context. The detection and characterization of exoplanets and brown dwarfs around massive AF-type stars is essential to investigate and constrain the impact of stellar mass on planet properties. However, such targets are still poorly explored in radial velocity (RV) surveys because they only feature a small number of stellar lines and those are usually broadened and blended by stellar rotation as well as stellar jitter. As a result, the available information about the formation and evolution of planets and brown dwarfs around hot stars is limited. Aims. We aim to increase the sample and precisely measure the masses and eccentricities of giant planets and brown dwarfs transiting early-type stars detected by the Transiting Exoplanet Survey Satellite (TESS). Methods. We followed bright (V < 12 mag) stars with T eff > 6200 K that host giant companions (R > 7 R ⊕ ) using ground-based photometric observations as well as high precision radial velocity measurements from the CORALIE, CHIRON, TRES, FEROS, and MINERVA-Australis spectrographs. Results. In the context of the search for exoplanets and brown dwarfs around early-type stars, we present the discovery of three brown dwarf companions, TOI-629b, TOI-1982b, and TOI-2543b, and one massive planet, TOI-1107b. From the joint analysis of TESS and ground-based photometry in combination with high precision radial velocity measurements, we find the brown dwarfs have masses between 66 and 68 M Jup , periods between 7.54 and 17.17 days, and radii between 0.95 and 1.11 R Jup . The hot Jupiter TOI-1107b has an orbital period of 4.08 days, a radius of 1.30 R Jup , and a mass of 3.35 M Jup . As a by-product of this program, we identified four low-mass eclipsing components (TOI-288b, TOI-446b, TOI-478b, and TOI-764b). Conclusions. Both TOI-1107b and TOI-1982b present an anomalously inflated radius with respect to the age of these systems. TOI-629 is among the hottest stars with a known transiting brown dwarf. TOI-629b and TOI-1982b are among the most eccentric brown dwarfs. The massive planet and the three brown dwarfs add to the growing population of well-characterized giant planets and brown dwarfs transiting AF-type stars and they reduce the apparent paucity.

brown dwarfs↗

Ultrahigh energy neutrinos from galactic neutron stars

An attempt is made to estimate the production rate of ultrahigh energy (UHE) neutrinos from galactic neutron stars. The statistics of various stellar populations are reviewed as well as an evolutionary scheme linking several neutron star environments. An observational test for predicting stellar evolution is made using two mass ratio intervals of less than 0.3 and greater than or approximately equal to 0.3, which is supported by kinematical evidence. Attention is given to the problem of the target material that is required by UHE protons accelerated from the pulsar's surface to their rotational kinetic energy, and to the detectability of neutron stars in the UHE neutrinos by employing the deep underwater muon and neutrino detector (DUMAND) array.

Helfand, D. J.↗

The Effect of Set Size on the Relation Between Saccadic and Perceptual Decisions During Search

We have shown that when searching for a disk in noise at one of 10 locations, the accuracy of the I st saccade is similar to that of the perceptual decision at the time of saccadic programming. The present study has two goals: 1) to test whether this linden - extends to a contrast-discrimination task without noise, and 2) to measure the effect of set size on the relation between saccadic and perceptual decisions. Methods: Three observers searched over a grey background (34.5 cd/sq m) for a bright disk (63.2 cd/sq m) among dim disks (54.1 cd/sq m) along the circumference of a circle (r = 5.9 deg.) centered on a fixation cress. Four set sizes (2, 4, 6, 12) were used. In the 1st condition, stimuli were presented for 1 sec. and observers used natural eye movements. We then measured the accuracy of the first saccade (% correct using a shortest-distance criterion). In the 2nd condition, observers fixated a central cross at all times and the stimulus duration was approx. 70 as less than the median latency of the first saccade in the 1st condition (saccadic programming time). We then recorded perceptual performance and discarded trials in which observers broke fixation. Results: For set sizes of 2, 4, 8, and 12, the mean d' across observers for the perceptual decision was 2.03, 1.96, 1.94, 1.71, respectively, while the mean d' of the first saccade was only 0.73, 1.40, 1.23, 1.17. Conclusions: Unlike detection of a disk in noise, for all observers and set-sizes, the perceptual accuracy at the time of saccadic programming is better than that of the lst saccade. For set-sizes of 4, 6, and 12, the amount of information available to the perceptual system relative to that available to the saccadic system is approximately constant (fixed do ratio). For these higher set sizes, the constancy in do across set size for both perception and saccadic decisions is consistent with a simple signal detection theory (SDT) model that processes noisy signals in parallel. However, for 2 observers, at a set-size of 2, saccadic targeting appears to be worse than the SDT model prediction, perhaps due to speed-accuracy trade-off.

Eckstein, M. P.↗

Hypervelocity Impact (HVI): General Introduction - Volume 1

During 2003 and 2004, the Johnson Space Center's White Sands Testing Facility in Las Cruces, New Mexico conducted hypervelocity impact tests on the space shuttle wing leading edge. Hypervelocity impact tests were conducted to determine if Micro-Meteoroid/Orbital Debris impacts could be reliably detected and located using simple passive ultrasonic methods. This volume contains an executive summary, overview of the method, brief descriptions of all targets, and highlights of results and conclusions.

Gorman, Michael R.↗

Surveillance and Control of Malaria Transmission in Thailand using Remotely Sensed Meteorological and Environmental Parameters

These slides address the use of remote sensing in a public health application. Specifically, this discussion focuses on the of remote sensing to detect larval habitats to predict current and future endemicity and identify key factors that sustain or promote transmission of malaria in a targeted geographic area (Thailand). In the Malaria Modeling and Surveillance Project, which is part of the NASA Applied Sciences Public Health Applications Program, we have been developing techniques to enhance public health's decision capability for malaria risk assessments and controls. The main objectives are: 1) identification of the potential breeding sites for major vector species; 2) implementation of a risk algorithm to predict the occurrence of malaria and its transmission intensity; 3) implementation of a dynamic transmission model to identify the key factors that sustain or intensify malaria transmission. The potential benefits are: 1) increased warning time for public health organizations to respond to malaria outbreaks; 2) optimized utilization of pesticide and chemoprophylaxis; 3) reduced likelihood of pesticide and drug resistance; and 4) reduced damage to environment. !> Environmental parameters important to malaria transmission include temperature, relative humidity, precipitation, and vegetation conditions. The NASA Earth science data sets that have been used for malaria surveillance and risk assessment include AVHRR Pathfinder, TRMM, MODIS, NSIPP, and SIESIP. Textural-contextual classifications are used to identify small larval habitats. Neural network methods are used to model malaria cases as a function of the remotely sensed parameters. Hindcastings based on these environmental parameters have shown good agreement to epidemiological records. Discrete event simulations are used for modeling the detailed interactions among the vector life cycle, sporogonic cycle and human infection cycle, under the explicit influences of selected extrinsic and intrinsic factors. The output of the model includes the individual infection status and the quantities normally observed in field studies, such as mosquito biting rates, sporozoite infection rates, gametocyte prevalence and incidence. Results are in good agreement with mosquito vector and human malaria data acquired by Coleman et al. over 4.5 years in Kong Mong Tha, a remote village in western Thailand. Application of our models is not restricted to the Greater Mekong Subregion. Our models have been applied to malaria in Indonesia, Korea, and other regions in the world with similar success.

Kiang, Richard K.↗

Photogrammetric system and method used in the characterization of a structure

A photogrammetric system uses an array of spaced-apart targets coupled to a structure. Each target exhibits fluorescence when exposed to a broad beam of illumination. A photogrammetric imaging system located remotely with respect to the structure detects and processes the fluorescence (but not the illumination wavelength) to measure the shape of a structure.

Dorrington, Adrian A.↗

Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot

The optical extinction of a laser due to scattering of particles is a well-known phenomenon. In a laboratory environment, this physical principle is known as the Beer-Lambert law, and is often used to measure the concentration of scattering particles in a fluid or gas. This method has been experimentally shown to be a usable means to measure the dust density from a rocket plume interaction with the lunar surface. Using the same principles and experimental arrangement, this technique can be applied to hydrometeor size distributions, and for launch-pad operations, specifically as a passive hail detection and measurement system. Calibration of a hail monitoring system is a difficult process. In the past, it has required comparison to another means of measuring hydrometeor size and density. Using a technique recently developed for estimating the density of surface dust dispersed during a rocket landing, measuring the extinction of a laser passing through hail (or dust in the rocket case) yields an estimate of the second moment of the particle cloud, and hydrometeor size distribution in the terrestrial meteorological case. With the exception of disdrometers, instruments that measure rain and hail fall make indirect measurements of the drop-size distribution. Instruments that scatter microwaves off of hydrometeors, such as the WSR-88D (Weather Surveillance Radar 88 Doppler), vertical wind profilers, and microwave disdrometers, measure the sixth moment of the drop size distribution (DSD). By projecting a laser onto a target, changes in brightness of the laser spot against the target background during rain and hail yield a measurement of the DSD's second moment by way of the Beer-Lambert law. In order to detect the laser attenuation within the 8-bit resolution of most camera image arrays, a minimum path length is required. Depending on the intensity of the hail fall rate for moderate to heavy rainfall, a laser path length of 100 m is sufficient to measure variations in optical extinction using a digital camera. For hail fall only, the laser path may be shorter because of greater scattering due to the properties of hailstones versus raindrops. A photodetector may replace the camera in automated installations. Laser-based rain and hail measurement systems are available, but they are based on measuring the interruption of a thin laser beam, thus counting individual hydrometeors. These systems are true disdrometers since they also measure size and velocity. The method reported here is a simple method, requiring far less processing, but it is not a disdrometer.

Lane, John↗

Spaceflight Microbiology: Benefits for Long Duration Spaceflight and Our Understanding of Microorganisms on Earth

Spaceflight microbiology is composed of both operational and experimental components that complement each other in our understanding of microbial interactions and their responses in the microgravity of spaceflight. Operationally, efforts to mitigate microbiological risk to the crew and the spacecraft have historically focused on minimizing the number of detectable organisms, relying heavily on preventative measures, including appropriate vehicle design, crew quarantine prior to flight, and stringent microbial monitoring. Preflight monitoring targets have included the astronauts, spaceflight foods, potable water systems, the vehicle air and surfaces, and the cargo carried aboard the spacecraft. This approach has been very successful for earlier missions; however, the construction and long-term habitation of the International Space Station (ISS) has created the need for additional inflight monitoring of the environment and potable water systems using hardware designed for both in-flight microbial enumeration and sample collection and return to Earth. In addition to operational activities, the ISS is providing a research platform to advance our understanding of microbiomes in the built environment. Adding to the research possibilities of this system are multiple reports of unique changes in microbial gene expression and phenotypic responses, including virulence and biofilm formation, in response to spaceflight culture. The tremendous potential of the ISS research platform led the National Research Council to recommend that NASA utilize the ISS as a microbial observatory. Collectively, the findings from operational and research activities on the ISS are expected to both enable future space exploration and translate to basic and applied research on Earth.

Ott, C. Mark↗

Fabrication of Nanopipette Arrays for Biosensing

Method for providing a nanopipette array for biosensing applications. A thin substrate of anodizable metal ("AN-metal," such as Al, Mg, Zn, Ti, Ta and/or Nb) is anodized at temperature T=20-200.degree. C., chemical bath pH=4-6 and electrical potential 1-300 Volts, to produce an array of anodized nanopipette channels, having diameters 10-50 nm, with oxidized channel surfaces of thickness 5-20 nm. A portion of exposed non-oxidized AN-metal between adjacent nanopipette channels, of length 1-5 .mu.m, is etched away, exposing inner and outer surfaces of a nanopipette channel. A probe molecule, is deposited on one or both surfaces to provide biosensing capability for K(.gtoreq.1) target molecules. Target molecule presence, in an above-threshold concentration, in a fluid passed through or adjacent to a nanopipette channel, produces characteristic detection signals associated with the probe molecule site.

Meyyappan, Meyya↗

Soil Interim Measures Implementation Report Q6 Radar Station – Solid Waste Management Unit 112 Locations of Concern 3 and 10 Kennedy Space Center, Florida

This report presents a summary of the soil interim measures (IM) implementation activities that occurred from January 23 through June 6, 2023, at the Q6 Radar Station (Q6RS) Solid Waste Management Unit (SWMU) 112, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program, which also meets the requirements of Chapter 62-780, Florida Administrative Code. Assessment activities have previously been performed at 10 Q6RS Locations of Concern (LOCs), identified during a SWMU assessment in 2013 (NASA 2013). Since the SWMU assessment, further confirmatory sampling and assessment was conducted for each LOC, and based on the data collected during these assessments, it was determined that Resource Conservation and Recovery Act Facility Investigation to further evaluate soil and groundwater was to be conducted at two LOCs: LOC 1 – Former Underground Storage Tanks (groundwater) and LOC 3 – Radar Antenna Refurbishment Area (soil). The LOC 1 groundwater assessment is ongoing, and the results will be presented under a separate cover. It was also determined that soil IM would be completed at two of the LOCs, LOC 3 and LOC 10 – Compressor Building Condensate Discharge. A Soil IM Work Plan was prepared and submitted in October 2021 (NASA 2021). The plan proposed excavation and disposal of barium and copper impacted soil in the LOC 3 and 10 areas. This report presents a summary and results of the soil IM implementation activities conducted at LOCs 3 and 10. The site contaminates of concern for this soil IM are barium and copper. The activities presented in this report includes soil IM implementation and groundwater sampling. From January 23 through March 24, 2023, AECOM Technical Services, Inc. (AECOM) field personnel conducted IM implementation activities in the LOC 3 and 10 areas. As presented in the IM Work Plan, shallow soils, impacted with metals, were excavated to a depth of 2 feet below land surface in the central area of the site around the radar antenna and associated equipment. AECOM personnel excavated 77.43 tons of soil using hand tools and, when able, heavy equipment. The soils were placed into lined roll-off containers, which were covered and transported under manifest to the Cedar Trail Landfill in Bartow, Florida. The site was restored to original condition using certified clean backfill material (sand), with filter fabric, and gravel. Areas outside of the excavation were restored with grass seed. On June 6, 2023, AECOM field personnel conducted groundwater sampling activities within the soil IM excavation area. AECOM personnel collected one groundwater sample from monitoring well Q6RS-MW0003. The sample was submitted to a fixed-based laboratory for analysis by United States Environmental Protection Agency Method 6020B for metals (barium and copper). Barium and copper were detected at 18 micrograms per liter (µg/L) and 14 µg/L, respectively, and were below the State of Florida Groundwater Cleanup Target Levels (GCTLs) for barium at 2,000 µg/L and copper at 1,000 µg/L.

Chadwick Sloan Lee↗

Early Fire Detection System for Partial and Low Gravity Environments

We present preliminary results on the development of a fire detection system for partial and low gravity environments. A significant challenge is the design of a system with a low false alarm rate. The detection system therefore has to discriminate between combustion particles, cabin, and lunar dust. Aerosol properties are measured and cross referenced to the target detectors at the Gases and Aerosols from Smoldering Polymers (GASP) Laboratory located at the NASA Glenn Research Center. A computational fluid dynamics plume model is also employed to determine the smoke transport properties of the targeted habitats.

Early fire detectioin↗

"GSFC FSB Application of Perspective-Based Inspections"

The scope of work described in our proposal consisted of developing inspection standards targeted to Branch-specific types of defects (gained from analysis of Branch project defect histories), and including Branch-relevant perspectives and questions to guide defect detection. The tailored inspection guidelines were to be applied on real Branch projects with support as needed from the technology infusion team. This still accurately describes the scope of work performed. It was originally proposed that the Perspective-Based inspection standard would be applied on three projects within the Branch: GPM, JWST, and SDO. Rather than apply the proposed standard to all three, we inserted a new step, in which the standard was instead applied on a single pilot project, cFE (described above). This decision was a good match for the Branch goals since, due to the "design for reuse" nature of cFE, inspections played an even more crucial than usual role in that development process. Also, since cFE is being designed to provide general-purpose functionality, key representatives fiom our target projects were involved in inspections of cFE to provide perspectives from different missions. In this way, they could get some exposure to and the chance to provide feedback on the proposed standards before applying them on their own projects. The Branch-baselined standards will still be applied on GPM, JWST, and SDO, although outside the time frame of this funding. Finally, we originally proposed using the analysis of Branch defect sources to indicate in which phases Perspective-Based inspections could provide the best potential for future improvement, although experience on previous Branch projects suggested that our efforts would likely be focused on requirements and code inspections. In the actual work, we focused exclusively on requirements inspections, as this was the highest-priority work currently being done on our cFE pilot project.

Shell, Elaine↗