A system for model access in tunnels with an unbreathable test medium
In many specialty wind tunnels, test gases other than ambient air are used to meet special testing requirements. A typical example is the use of freon as the test gas to achieve a realistic density ratio between gas and model for exploring flutter stability boundaries. Another example is the use of pressurized air to elevate the stream density and enhance Reynolds number or dynamic pressure simulation. Such specialty tunnels require a system of access o the model which will allow services and changes to the model without exposing personnel to the unnatural and perhaps hostile environment or requiring the venting and purging of the entire tunnel circuit. This paper will describe the plenum and model access systems for the forthcoming U.S. National Transonic facility where gaseous nitrogen (N2) at temperatures between 338 and 78 K and at pressures to 9 bars is used as the test medium. The operation at cold temperatures imposes some additional requirements which make the access systems more difficult to design and time consuming to operate than for conventional wind tunnels.