Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “suspensions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Fractionation of mineral species by electrophoresis

The fractionation of fine-grained aggregates into their major components is a problem in many scientific areas including earth and planetary science. Electrophoresis, the transport of electrically charged particles, immersed in a suspension medium, by a direct current field (Bier, 1959), was employed in this study as a means of separating simulated lunar soil into its constituent minerals. In these tests, conducted in a static analytical cylindrical microelectrophoresis apparatus, samples of simulated lunar soil and samples of pure mineral constituents were placed in the chamber; the electrophoretic mobilities of the lunar soil and the individual mineral constituents were measured. In most of the suspension buffers employed separability was indicated, on the basis of differences in mobility, for all the constituent mineral species except ilmenite and pyroxene, which were not efficiently separable in any of the buffers. Although only a few suspension media were employed, the success of this initial study suggests that electrophoresis may be an important mineral fractionation option in fine-grained aggregate processing.

Dunning, J. D.↗

Influence of deflocculant on the isoelectric point of refractory powders: Considerations on the action of deflocculant

Isoelectric point changes in suspensions of refractory materials vis-a-vis the role of deflocculants used in monolithic refractories were investigated by considering the mineral compositions and adsorbed ions in four kinds of clay. Three types of curves represented the relation between the isoelectric point and the deflocculant. The surface charge of clay particles in the suspensions became negative as a result of the deflocculant, since the isoelectric point of suspensions decreased as the deflocculant was added. The isoelectric point changes of calcined alumina were also compared with those of the clays, and a similar phenomenon was observed, except that the deflocculant dispersed the calcined alumina better than it did the clays. A simple model was used to analyze the results.

Naruse, Y.↗

Physiological changes in fast and slow muscle with simulated weightlessness

A rat hindlimb suspension model of simulated weightlessness was used to examine the physiological characteristics of skeletal muscle. The physiological sequelae of hindlimb suspension were compared to those of spinal cord section, denervation by sciatic nerve crush, and control. Muscle examined were the predominantly slow (Type 1) soleus (SOL) and the predominantly fast (Type 2) extensor digitorum longus (EDL). Two procedures which alter motor unit activity, hindlimb suspension and spinal cord section, produce changes in characteristics of skeletal muscles that are dependent upon fiber type. The SOL develops characteristics more representative of a fast muscle, including smaller Type 1 fiber proportion and higher AChE activity. The EDL, which is already predominantly fast, loses most of its few Type 1 fibers, thus also becoming faster. These data are in agreement with the studies in which rats experienced actual weightlessness.

Dettbarn, W. D.↗

Regulation of hematopoiesis in the suspended rat as a model for space flight

A series of studies was completed in which a variety of routine hematological and other parameters were obtained from sequential sampling of control and suspended rats. These data showed that, during suspension, the rats failed to gain weight at the same rate as the controls, ate and drank significantly less, demonstrated a transient increase in peripheral hematocrit and RBC count, a transient decrease in MCH, suppressed reticulocyte counts and a progressive decrease in MCV but no change in RBC shape. Leukocyte counts were variably decreased but no significant changes in platelet numbers were noted. Post-suspension, evidence of anemia was present from a reduced RBC count, hemoglobin, hematocrit, and MCV. A leukocytosis was also noted. Efforts directed to the collection of data aimed at understanding changes in blood volume during suspension are also discussed. As part of these studies the following parameters were investigated; RBC survival, in vitro leukocyte reactivity to PHA, bone marrow and spleen cellularity and morphology, ferrokinetics, and the hematopoietic inductive microenvironment.

Dunn, C. D. R.↗

The validity of an animal model for experiments related to weightlessness

Animal evolution has witnessed morphological and physiological adaptations to gravitational forces. In the rat, hind limb muscles can be used to illustrate a range of load bearing functions: soleus - gastrocnemius = plantaris - extensor digitorum longus (EDL). A harness suspension apparatus is used to induce hypokinesia and hypodynamia (H&H) and to simulate responses comparable to those seen in weightlessness (i.e., COSMOS experiments). After one and two weeks of suspension H&H, there is muscle atrophy with a loss in muscle mass; the result of loss in muscle protein. Concommitantly, there is a decrease in RNA, but not in DNA content. The effects are greatest in the soleus and least in the EDL. These recent findings, in concert with earlier reports of increased nitrogenous excretion, suggest that both decreased protein synthesis and increased protein catabolism are characteristic of muscle atrophy. Recovery is seen in terms of reversal of these effects after removal from suspension.

Musacchia, X. J.↗

Effect of superconducting solenoid model cores on spanwise iron magnet roll control

Compared with conventional ferromagnetic fuselage cores, superconducting solenoid cores appear to offer significant reductions in the projected cost of a large wind tunnel magnetic suspension and balance system. The provision of sufficient magnetic roll torque capability has been a long-standing problem with all magnetic suspension and balance systems; and the spanwise iron magnet scheme appears to be the most powerful system available. This scheme utilizes iron cores which are installed in the wings of the model. It was anticipated that the magnetization of these cores, and hence the roll torque generated, would be affected by the powerful external magnetic field of the superconducting solenoid. A preliminary study has been made of the effect of the superconducting solenoid fuselage model core concept on the spanwise iron magnet roll torque generation schemes. Computed data for one representative configuration indicate that reductions in available roll torque occur over a range of applied magnetic field levels. These results indicate that a 30-percent increase in roll electromagnet capacity over that previously determined will be required for a representative 8-foot wind tunnel magnetic suspension and balance system design.

Britcher, C. P.↗

Tissue fluid shift, forelimb loading, and tail tension in tail-suspended rats

The tail suspension model (head-down tilt) simulates hypogravity in terms of musculoskeletal loss in the rat. However, little is known of tissue fluid shifts and body weight distribution in this model. Tissue fluid pressures were measured by wick catheters in 12 Munich-Wistar rats before, during, and after 48 hrs of tail suspension (about 30 deg head-down tilt). Subcutaneous tissue fluid pressure in the neck increased from -2.2 + or - 0.4 (normal horizontal position) to +4.0 + or - 1.5 cm H2O during tail suspension, indicating a cephalic fluid shift and significant edema during head-down tilt. In a separate study, six rats were suspended at 30-70 deg, and forelimb load and tail tension were measured by a balance and force transducer, respectively. Approximately 50 percent of body weight (BW) was loaded on forelimbs at a head-down tilt angle of 30 deg and forelimb load declined linearly to 10 percent BW at 70 deg. Furthermore, tail tension increased from 50 percent BW at 30 deg to 85 percent BW at 70 deg. These results indicate that less than normal loads are applied to forelimbs of rats suspended at angles of less than 30 deg and that the tail bears an increasing proportion of the rat's body weight at head-down tilt angles of less than 30 deg.

Hargens, A. R.↗

Development and testing of a mouse simulated space flight model

The development and testing of a mouse model for simulating some aspects of weightlessness that occurs during space flight, and the carrying out of immunological experiments on animals undergoing space flight is examined. The mouse model developed was an antiorthostatic, hypokinetic, hypodynamic suspension model similar to one used with rats. The study was divided into two parts. The first involved determination of which immunological parameters should be observed on animals flown during space flight or studied in the suspension model. The second involved suspending mice and determining which of those immunological parameters were altered by the suspension. Rats that were actually flown in Space Shuttle SL-3 were used to test the hypotheses.

Sonnenfeld, Gerald↗

Magnetic bearings for inertial energy storage

Advanced flywheels utilizing high strength fibers must operate at high rotational speeds and as such must operate in vacuum to reduce windage losses. The utilization of magnetic bearings in the flywheels overcome lubrication and seal problems, resulting in an energy storage system offering potential improvements over conventional electrochemical energy storage. Magnetic bearings evolved in the 1950s from the simple application of permanent magnets positioned to exert repulsive forces to the present where permanent magnets and electromagnets have been combined to provide axial and radial suspension. Further development of magnetic suspension has led to the design of a shaftless flywheel system for aerospace application. Despite the lack of proof of concept, integrated magnetic suspension in inertial storage systems can provide significant performance improvements to warrant development and tests.

Rodriguez, G. Ernest↗

Effects of simulated weightlessness and sympathectomy on maximum VO2 of male rats

The effects of simulated weightlessness (hind-limb suspension) and chemical sympathectomy (by repeated injections with guanethidine sulfate) on the maximum oxygen consumption (VO2 max) of female rats were investigated in rats assigned for 14 days to one of three groups: a head-down hind-limb suspension, a horizontal suspension with hind limbs weight bearing, or the caged control. The VO2 max values were assessed by having rats run on a treadmill enclosed in an airtight chamber. The hind-limb-suspended sympathectomized rats were found to exhibit shorter run times and lower mechanical efficiencies, compared to their presuspension values or the values from saline-injected suspended controls. On the other hand, the suspended sympathectomized rats did not demonstrate a decrease in the VO2 max values that was observed in saline-injected controls.

Woodman, C. R.↗

Influence of single hindlimb support during simulated weightlessness in the rat

A study was carried out to develop and evaluate a hindlimb suspension model, making it possible to differentiate the effects of non-weight bearing by hindlimbs per se from the systemic influence of simulated weightlessness. A support platform was designed which allowed the animal to maintain one hindlimb in a posture similar to the hindlimbs of the control animals at rest and to maintain one hindlimb in a posture similar to the hindlimbs of the control animals, providing a support for the animal to contract or stretch hindlimb muscles against at any time during suspension. The results of this study indicated that hindlimb support during head-down suspension will maintain muscle-mass/body-mass ratios, glycogen concentration, and blood flow. However, it will not prevent the loss in citrate synthase activity associated with conditions of simulated weightlessness.

Stump, Craig S.↗

Initial blood storage experiment

The design of the Initial Blood Storage Experiment (IBSE) was based upon a carefully controlled comparison between identical sets of human blood cell suspensions - red cells, white cell, and platelets - one set of which was transported aboard the Columbia on a 6 day 11 hour mission, and the other held on the ground. Both sets were carried inside stainless steel dewars within specially fabricated flight hardware. Individual bags of cell suspensions were randomly assigned with respect to ground vs orbit status, dewar chamber, and specific location within the dewar. To foster optimal preservation, each cell type was held under specific optimal conditions of pH, ionic strength, solute concentration, gas tension, and temperature. An added variable in this initial experiment was provided by the use of three different polymer/plasticizer formulations for the sealed bags which held the blood cells. At termination of the experiment, aliquots of the suspensions, identified only by code, were distributed to be assayed. Assays were selected to constitute a broad survey of cellular properties and thereby maximize the chances of detection of gravitational effects. A total of 74 different outcome measurements were reported for statistical analysis. When the measurements were completed, the results were entered into the IBSE data base, at which time the data were matched with the original blood bag numbers to determine their status with respect to polymer/plasticizer type, orbit status (orbit or ground), and storage position within the experimental hardware. The data were studied by analysis of variance. Initially, type of bag and orbital status were main factors; later more detailed analyses were made on specific issues such as position in the hardware and specific plastic. If the analysis of variance indicated a statistical significance at the 5 percent level the corresponding p-value was reported.

Surgenor, Douglas MACN.↗

Cosmos 2044

The effects of microgravity and hind limb suspension on the enzyme patterns are assessed within a slow twitch muscle (soleus) and a fast twitch muscle (tibialis anterior). Studies were made on 95 soleus fibers and about 300 tibialis anterior (TA) fibers. Over 2200 individual enzyme measurements were made. Six key metabolic enzymes (hexokinase, pyruvate kinease, citrate kinase, beta-hydroxyacyl CoA dehydrogenase, glucose-6-P dehydrogenase, and aspartate aminotransferase) plus glutaminase and glutamate decarboxylase, as well as glutamate, aspartate, and GABA, were measured in 11 regions of the hippocampal formation of synchronous, flight, and tail suspension rats. Major differences were observed in the normal distribution of each enzyme and amine acid, but no substantive effects of either microgravity or tail suspension on these patterns were clearly demonstrated.

Lowry, Oliver H.↗

Effect of 29 days of simulated microgravity on maximal oxygen consumption and fat-free mass of rats

Effects of a 29-days exposure to simulated microgravity on the values of maximal oxygen consumption and fat-free mass (FFM) and on the mechanical efficiency of running were investigated in rats randomly assigned to one of three regimens: head-down suspension (HDS) at 45 deg, horizontal suspension (HS), or cage control (CC). Before suspension and on days 7, 14, 21, and 28, five exercise performance tests were carried out, with measurements related to maximal oxygen consumption, treadmill run time, and mechanical efficiency. It was found that maximal oxygen consumption of both HDS and HS groups decreased significantly at day 7, after which the HDS rats remained decreased while the HS rats returned to presuspension values. Apparent mechanical efficiency in the HDS and HS groups decreased by 22-35 percent during the experimental period, and FFM decreased significantly.

Woodman, Christopher R.↗

Magnetic bearings: Fifty years of progress

Magnetic bearings are just beginning to be flown in spacecraft systems, but their development spans more than 50 years. The promise of completely noncontacting, unlubricated rotating systems operating at speeds substantially beyond the range of conventional bearings, and with no wear and virtually no vibration, has provided the incentive to develop magnetic bearing technology for many diverse applications. Earnshaw theorized in 1842 that stable magnetic suspension is not possible in all three spatial directions unless the magnetic field is actively controlled. Since that time, researchers have attempted to successfully support spinning rotors in a stable manner. Development of magnetic suspension systems over the past fifty years has included progress on both passive (permanent magnet) and active (electromagnet) systems. The improvements in bearing load capacity, stiffness, and damping characteristics are traced. The trends in rotor size, rotational kinetic energy, and improvements in active control systems capabilities are also reviewed. Implications of superconductivity on suspension system design and performance are discussed.

Swann, Michael K.↗

Advanced actuators for the control of large space structures

The objective of this research was to develop advanced six-degree-of-freedom actuators employing magnetic suspensions suitable for the control of structural vibrations in large space structures. The advanced actuators consist of a magnetically suspended mass that has three-degrees-of-freedom in both translation and rotation. The most promising of these actuators featured a rotating suspended mass providing structural control torques in a manner similar to a control moment gyro (CMG). These actuators employ large-angle-magnetic suspensions that allow gimballing of the suspended mass without mechanical gimbals. Design definitions and sizing algorithms for these CMG type as well as angular reaction mass actuators based on multi-degree-of-freedom magnetic suspensions were developed. The performance of these actuators was analytically compared with conventional reaction mass actuators for a simple space structure model.

Downer, James↗

Optimization of the parameters for a rotating, mixed-phase reactor

The motion of small, monodisperse particles in fluid was studied in a horizontal, cylindrical container rotating about its axis. One instigation for the study was the common requirement for mixed-phase, chemical or biological reactors to maintain particles in suspension for extended periods. A cylindrical, rotating reactor can allow long-term particle suspension without particle collisions and resulting agglomeration. The purpose of this study was to verify parametric effects and optimize the time of particle suspension. The theoretical and experimental results were obtained for inert, constant-diameter particles of nearly neutral buoyancy. The centrifugal buoyancy and gravitation terms were both included in the equations of motion. Laser illumination, photography and computer imaging were used to measure experimental particle concentration.

Cleland, J. G.↗

Modal parameters of space structures in 1 G and 0 G

Analytic and experimental results are presented from a study of the changes in the modal parameters of space structural test articles from one- to zero-gravity. Deployable, erectable, and rotary modules was assembled to form three one- and two-dimensional structures, in which variations in bracing wire and rotary joint preload could be introduced. The structures were modeled as if hanging from a suspension system in one gravity, and unconstrained, as if free floating in zero-gravity. The analysis is compared with ground experimental measurements, which were made on a spring-wire suspension system with a nominal plunge frequency of one Hertz, and with measurements made on the Shuttle middeck. The degree of change in linear modal parameters as well as the change in nonlinear nature of the response is examined. Trends in modal parameters are presented as a function of force amplitude, joint preload, reassembly, shipset, suspension, and ambient gravity level.

Bicos, Andrew S.↗