Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Comparison of soil organic carbon speciation using C NEXAFS and CPMAS 13 C NMR spectroscopy

Here, we compared synchrotron-based C near-edge X-ray absorption fine structure (NEXAFS) and CPMAS 13 C nuclear magnetic resonance (NMR) spectroscopy with respect to their precision and accuracy to quantify different organic carbon (OC) species in defined mixtures of soil organic matter source compounds. We also used both methods to quantify different OC species in organic surface horizons of a Histic Leptosol as well as in mineral topsoil and subsoil horizons of two soils with different parent material, stage of pedogenesis, and OC content (Cambisol: 15–30 OC mg g -1 , Podzol: 0.9–7 OC mg g -1 ). CPMAS 13 C NMR spectroscopy was more accurate and precise (mean recovery of different C functional groups 96–103%) than C NEXAFS spectroscopy (mean recovery 92–113%). For organic surface and topsoil samples, NMR spectroscopy consistently yielded larger O-alkyl C percentages and smaller alkyl C percentages than C NEXAFS spectroscopy. For the Cambisol subsoil samples both methods performed well and showed similar C speciation results. NEXAFS spectroscopy yielded excellent spectra with a high signal-to-noise ratio also for OC-poor Podzol subsoil samples, whereas this was not the case for CPMAS 13 C NMR spectroscopy even after sample treatment with HF. Our results confirm the analytical power of CPMAS 13 C NMR spectroscopy for a reliable quantitative OC speciation in soils with >10 mg OC g -1 . Moreover, they highlight the potential of synchrotron-based C NEXAFS spectroscopy as fast, non-invasive method to semi-quantify different C functional groups in soils with low C content (0.9–10 mg g -1 ).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Splittings, Satellites and Fine Structure in the Soft X-ray Spectroscopy of the Actinides

Perhaps the most demanding and powerful actinide spectroscopy is that using soft X-ray and VUV photons. Because of the relatively low energy and fairly small sampling depths of these photons and the corresponding electrons, it is necessary to use un-encapsulated samples with highly cleaned and well-prepared surfaces. This causes a myriad of sample containment problems for these radioactive materials. Despite these hindrances and difficulties, the soft-X-ray and ultra-violet spectroscopy of the actinides can provide an amazing level of detailed information, particularly having to do with 5f electronic structure. In this paper, the splittings, satellites and fine structure of the following actinide soft X-ray spectroscopies will be discussed: X-ray photoelectron spectroscopy; X-ray absorption spectroscopy; and inverse photoelectron spectroscopy, including Bremstrahlung isochromat spectroscopy and resonant inverse photoelectron spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser spectroscopy-present and future at ISOLDE

Laser spectroscopy experiments at the ISOLDE facility have a venerable history which now spans more than 30 years. This period has seen the development of a remarkable variety of laser techniques in order to study rare isotopes far from stability, which include in-source, collinear and {beta}-NMR/{beta}-NQR spectroscopy. The propensity for innovation in laser spectroscopy at ISOLDE has continued in the last three years, helped in part by synergies with laboratories across Europe. Highlights of this work include bunched-beam spectroscopy of the neutron-rich copper and gallium isotope chains and collinear-anticollinear spectroscopy of the Be isotope chain. New ionization schemes have been developed for the Po atom crucial for the successful in-source laser spectroscopy campaign. The future HIE-ISOLDE facility will provide experimentalists with improved ion-beam quality, increased yields and a larger number of accessible elements. Several new experiments are now in preparation to maximise the reach of laser spectroscopy at HIE-ISOLDE, which include collinear resonance ionization spectroscopy and in-cooler optical pumping.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Where Water Is Oxidized to Dioxygen: Structure of the Photosynthetic Mn(4)Ca Cluster From X-Ray Spectroscopy

Light-driven oxidation of water to dioxygen in plants, algae, and cyanobacteria is catalyzed within photosystem II (PS II) by a Mn{sub 4}Ca cluster. Although the cluster has been studied by many different methods, its structure and mechanism have remained elusive. X-ray absorption and emission spectroscopy and extended X-ray absorption fine structure studies have been particularly useful in probing the electronic and geometric structures and the mechanism of the water oxidation reaction. Recent progress, reviewed here, includes polarized X-ray absorption spectroscopy measurements of PS II single crystals. Analysis of those results has constrained the Mn{sub 4}Ca cluster geometry to a set of three similar high-resolution structures. The structure of the cluster from the present study is unlike either the 3.0- or 3.5-{angstrom}-resolution X-ray structures or other previously proposed models. The differences between the models derived from X-ray spectroscopy and crystallography are predominantly because of damage to the Mn{sub 4}Ca cluster by X-rays under conditions used for the structure determination by X-ray crystallography. X-ray spectroscopy studies are also used for studying the changes in the structure of the Mn{sub 4}Ca catalytic center as it cycles through the five intermediate states known as the S{sub i} states (i = 0--4). The electronic structure of the Mn{sub 4}Ca cluster has been studied more recently using resonant inelastic X-ray scattering spectroscopy (RIXS), in addition to the earlier X-ray absorption and emission spectroscopy methods. These studies are revealing that the assignment of formal oxidation states is overly simplistic. A more accurate description should consider the charge density on the Mn atoms, which includes the covalency of the bonds and delocalization of the charge over the cluster. The geometric and electronic structures of the Mn{sub 4}Ca cluster in the S states derived from X-ray spectroscopy are leading to a detailed understanding of the mechanism of O-O bond formation during the photosynthetic water-splitting process.

36 MATERIALS SCIENCE↗

Investigation of soil properties using different techniques of mid‐infrared spectroscopy

Summary Diffuse reflectance spectroscopy (DRF), attenuated total reflectance spectroscopy (ATR) and Fourier transform infrared photoacoustic spectroscopy (PAS) are useful techniques that are commonly used to characterize soil properties. Here, these techniques were used to evaluate individual properties of 1456 paddy soil samples from Nanjing, China, to explore their features in the mid‐infrared range. The diffuse reflectance spectroscopy showed broad and shouldered peaks that ranged from 4000 to 500 cm −1 . Attenuated total reflectance spectroscopy produced main peaks around 1000 cm −1 . Fourier transform infrared photoacoustic spectroscopy spectra showed several moderate intensity peaks in the regions of 4000–2600 and 2500–500 cm −1 . The effective variables (wavenumbers) were selected using an uninformative variable elimination (UVE) algorithm to predict soil pH, and soil organic matter (SOM), total nitrogen (TN) and available phosphorus (AP) contents; it used a self‐adaptive partial least squares model (SAM–PLS). The results showed that selected wavenumbers improved the accuracy of prediction for pH, and SOM, TN and AP contents. For the prediction of pH, ATR spectra showed marginally better performance than the other spectra. The DRF spectroscopy was the optimal method for SOM and TN prediction. Available phosphorus contents were predicted poorly by all three spectra. Furthermore, mid‐infrared incident light paths, absorption modes, sensing styles, as well as peak interference and the prediction model, were the main factors that affected the assessment of soil properties in the three types of spectroscopy. Highlights Soil spectra data were measured with DRF, ATR and PAS spectrometers over the range 4000–500 cm −1 . A UVE algorithm was used to select effective wavenumbers from the full spectrum. The pH, SOM, TN and AP were estimated using three techniques based on a SAM–PLS model. Mid‐infrared incident light paths and absorption modes affected prediction performance of the three techniques.

Ma, F.↗

Machine learning in analytical spectroscopy for nuclear diagnostics [Invited]

Analytical spectroscopy methods have shown many possible uses for nuclear material diagnostics and measurements in recent studies. In particular, the application potential for various atomic spectroscopy techniques is uniquely diverse and generates interest across a wide range of nuclear science areas. Over the last decade, techniques such as laser-induced breakdown spectroscopy, Raman spectroscopy, and x-ray fluorescence spectroscopy have yielded considerable improvements in the diagnostic analysis of nuclear materials, especially with machine learning implementations. These techniques have been applied for analytical solutions to problems concerning nuclear forensics, nuclear fuel manufacturing, nuclear fuel quality control, and general diagnostic analysis of nuclear materials. The data yielded from atomic spectroscopy methods provide innovative solutions to problems surrounding the characterization of nuclear materials, particularly for compounds with complex chemistry. Implementing these optical spectroscopy techniques can provide comprehensive new insights into the chemical analysis of nuclear materials. In particular, recent advances coupling machine learning methods to the processing of atomic emission spectra have yielded novel, robust solutions for nuclear material characterization. This review paper will provide a summation of several of these recent advances and will discuss key experimental studies that have advanced the use of analytical atomic spectroscopy techniques as active tools for nuclear diagnostic measurements.

Rao, Ashwin P. (ORCID:0000000319312568)↗

Nanoscale solid-state nuclear quadrupole resonance spectroscopy using depth-optimized nitrogen-vacancy ensembles in diamond

Nuclear magnetic resonance (NMR) and nuclear quadrupole resonance (NQR) spectroscopy of bulk quantum materials have provided insight into phenomena, such as quantum phase criticality, magnetism, and superconductivity. With the emergence of nanoscale 2D materials with magnetic phenomena, inductively detected NMR and NQR spectroscopy are not sensitive enough to detect the smaller number of spins in nanomaterials. The nitrogen-vacancy (NV) center in diamond has shown promise in bringing the analytic power of NMR and NQR spectroscopy to the nanoscale. However, due to depth-dependent formation efficiency of the defect centers, noise from surface spins, band bending effects, and the depth dependence of the nuclear magnetic field, there is ambiguity regarding the ideal NV depth for surface NMR of statistically polarized spins. In this work, we prepared a range of shallow NV ensemble layer depths and determined the ideal NV depth by performing NMR spectroscopy on statistically polarized 19 F in Fomblin oil on the diamond surface. We found that the measurement time needed to achieve a signal-to-noise ratio of 3 using XY8-N noise spectroscopy has a minimum at an NV ensemble depth of 5.5 ± 1.5 nm for ensembles activated from 100 ppm nitrogen concentration. To demonstrate the sensing capabilities of NV ensembles, we perform NQR spectroscopy on the 11 B of hexagonal boron nitride flakes. We compare our best diamond to previous work with a single NV and find that this ensemble provides a shorter measurement time with excitation diameters as small as 4 μm. Furthermore, this analysis provides ideal conditions for further experiments involving NMR/NQR spectroscopy of 2D materials with magnetic properties.

2D materials↗

Soft X-ray Spectroscopy Study of the Electronic Structure of Oxidized and Partially Oxidized Magnetite Nanoparticles

The crystal structure of magnetite nanoparticles may be transformed to maghemite by complete oxidation, but under many relevant conditions the oxidation is partial, creating a mixed-valence material with structural and electronic properties that are poorly characterized. We used X-ray diffraction, Fe K-edge extended X-ray absorption fine structure (EXAFS) spectroscopy, and soft X-ray absorption and emission spectroscopy to characterize the products of oxidizing uncoated and oleic acid-coated magnetite nanoparticles in air. The oxidization of uncoated magnetite nanoparticles creates a material that is structurally and electronically indistinguishable from maghemite. By contrast, while oxidized oleic acid-coated nanoparticles are also structurally indistinguishable from maghemite, Fe L-edge spectroscopy revealed the presence of interior reduced iron sites even after a 2-year period. We used X-ray emission spectroscopy at the O K-edge to study the valence bands (VB) of the iron oxide nanoparticles, using resonant excitation to remove the contributions from oxygen atoms in the ligands and from low-energy excitations that obscured the VB edge. The bonding in all nanoparticles was typical of maghemite, with no detectable VB states introduced by the long-lived, reduced-iron sites in the oleic acid-coated sample. However, O K-edge absorption spectroscopy observed a 0.2 eV shift in the position of the lowest unoccupied states in the coated sample, indicating an increase in the semiconductor band gap relative to bulk stoichiometric maghemite that was also observed by optical absorption spectroscopy. The results show that the ferrous iron sites within ferric iron oxide nanoparticles coated by an organic ligand can persist under ambient conditions with no evidence of a distinct interior phase and can exert an effect on the global electronic and optical properties of the material. This phenomenon resembles the band gap enlargement caused by electron accumulation in the conduction band of TiO2.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultrafast terahertz spectroscopy provides insight into charge transfer efficiency and dynamics in artificial photosynthesis

Terahertz (THz) spectroscopy provides a noncontact method to measure the ultrafast dynamics and photoconductivity of mobile carriers in semiconducting materials. This has proven useful in studying artificial photosynthesis devices which use semiconductor photoelectrodes. In this work, we present a brief introduction to optical-pump THz-probe (OPTP) spectroscopy, a technique that provides unique and useful insight into interfacial electron transfer (from the surface-attached dye to the conduction band of the semiconductor) in dye-sensitized photoelectrochemical cells. Compared with more familiar methods like visible transient absorption spectroscopy, OPTP spectroscopy stands out in offering both sub-picosecond time resolution as well as sensitivity to mobile carriers (electrons and holes) in the semiconductor portion of artificial photosynthesis devices. The mobile carriers are crucial to device performance as only they pass to the other half cell to complete the reaction. In order to highlight these advantages and illustrate the types of questions OPTP spectroscopy can address, we discuss three case studies. In the first, OPTP spectroscopy is used to measure the injection rates from a set of six different dyes, revealing the effect of the energetics and lifetimes of the dye excited states on interfacial electron transfer. The subsequent case studies investigate the influence of varying the moieties which bind to the surface (anchors), as well as the moieties that connect the chromophore with these anchors (linkers). OPTP spectroscopy was used to measure the interfacial electron transfer rate as these moieties were varied.

59 BASIC BIOLOGICAL SCIENCES↗

Semiconductor-to-metallic flipping in a ZnFe{sub 2}O{sub 4}–graphene based smart nano-system: Temperature/microwave magneto-dielectric spectroscopy

Zn-(FeO{sub 2}){sub 2}–graphene smart nano-composites were synthesized using a novel modified solvothermal synthesis with different percentages of graphene. The structure of the nanocomposite was confirmed through X-ray diffraction, micro-Raman scattering spectroscopy, Ultraviolet–Visible spectroscopy, and Fourier transform infrared spectroscopy. The structural growth and morphological aspects were analyzed using scanning/transmission electron microscopy, revealing marvelous micro-structural features of the assembled nano-system resembling a maple leaf. To determine the composition, energy dispersive spectroscopy and X-ray photoelectron spectroscopy were used. Microwave magneto-dielectric spectroscopy revealed the improved dielectric properties of the nano-composite compared to those of the parent functional nanocrystals. Temperature gradient dielectric spectroscopy was used over the spectral range from 100 Hz to 5 MHz to reveal the phenomenological effect that the nanosystem flips from its usual semiconductor nature to a metallic nature with sensing temperature. Electrical conductivity and dielectric analysis indicated that the dielectric loss and the dielectric permittivity increased at room temperature. This extraordinary switching capability of the functionalized graphene nanosystem opens up a new dimension for engineering advanced and efficient smart composite materials. - Graphical abstract: Display Omitted - Highlights: • Zn-(FeO{sub 2}){sub 2}–graphene smart nano-composites were synthesized using a novel modified solvothermal synthesis. • The synthesized nano-system exhibits marvelous leaf like microstructure. • These nano-composites show improved magneto dielectric response. • This engineered smart nano-system shows phenomenological flipping from semiconductor like nature to metallic behavior.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

From Femtosecond Dynamics to Breast Cancer Diagnosis by Raman Spectroscopy

This paper presents new results based on Raman spectroscopy and demonstrates its utilisation as a diagnostic and development tool with the key advantage in breast cancer research. Applications of Raman spectroscopy in cancer research are in the early stages of development. However, research presented here as well as performed in a few other laboratories demonstrate the ability of Raman spectroscopy to accurately characterize cancer tissue and distinguish between normal, malignant and benign types. The main goals of bio-Raman spectroscopy at this stage are threefold. Firstly, the aim is to develop the diagnostic ability of Raman spectroscopy so it can be implemented in a clinical environment, producing accurate and rapid diagnoses. Secondly, the aim is to optimize the technique as a diagnostic tool for the non-invasive real time medical applications. Thirdly, the aim is to formulate some hypothesis based on Raman spectroscopy on the molecular mechanism which drives the transformation of normal human cells into highly malignant derivatives. To the best of our knowledge, this is the most statistically reliable report on Raman spectroscopy-based diagnosis of breast cancers among the world women population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early- and late-time dynamics of laser-produced plasmas by combining emission and absorption spectroscopy

Optical emission spectroscopy and laser absorption spectroscopy are two highly complementary techniques for diagnosing plasmas, specifically in the determination of important parameters such as temperature and density. In this work, we characterized a laser-produced plasma by combining emission and tunable absorption spectroscopy. Plasmas are produced by focusing pulses from a frequency quadrupled Nd:YAG laser onto a glass target containing a minor concentration of aluminum in an ambient atmosphere of ~100 Torr N 2 . Here, emission spectroscopy is used to investigate the line behavior of Al and Ca, electron density, and excitation temperature at times = 5 μs, while absorption spectroscopy is used to investigate the line behavior of Al and Ca, species density, and kinetic temperature at times = 5-100 μs. A comparison is made between the excitation temperature measured from emission using the Boltzmann plot method and the kinetic temperature measured from absorption; the implications of this comparison on local thermodynamic equilibrium and line-of-sight averaging are discussed. By combining the two methods of optical emission and laser absorption spectroscopy, a comprehensive characterization of the plasma over the entire lifetime of its evolution is possible, leading to a greater understanding of the plasma behavior including particle condensation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparative study of multimodal data fusion strategies for planetary spectroscopy

Integrating heterogeneous data sources can improve scientific inference when different modalities capture complementary information, but doing so is challenging in high-dimensional, small-sample settings. In spectroscopy for planetary exploration, Laser-Induced Breakdown Spectroscopy (LIBS), Raman Spectroscopy (Raman), Visible Infrared Spectroscopy (VISIR), and Mid-Infrared Spectroscopy (MIR) each examine different aspects of composition and mineralogy, raising fundamental questions about when and how data fusion improves predictive performance. Using a Mars-relevant set of geologic standards with measurements from all four modalities, we present a rigorous systematic evaluation of four data fusion strategies: low-level (data) fusion, mid-level (feature) fusion, high-level (decision) fusion, and residual-boosting (sequential) fusion. We assess performance in predicting oxide composition via nested cross-validation and corrected significance testing to evaluate whether data fusion improves upon single-modality baselines. We show that data fusion does not uniformly improve accuracy, and that observed gains are modest, oxide-dependent, and sensitive to modality and model structure. To move beyond aggregate accuracy metrics, we use model coefficients, permutation importance, and residual gain analysis to examine how the fusion models weight individual modalities and to identify patterns of apparent complementarity or redundancy. Though focused on spectroscopy for planetary exploration, our framework for data fusion evaluation and interpretation extends to other scientific domains with heterogeneous and scarce data and provides a principled approach evaluating data fusion strategies, interpreting modality contributions, and understanding tradeoffs among data fusion strategies.

97 MATHEMATICS AND COMPUTING↗

Design and Calibration of a Raman Spectrometer for use in a Laser Spectroscopy Instrument Intended to Analyze Martian Surface and Atmospheric Characteristics for NASA

This project's goal is the design of a Raman spectroscopy instrument to be utilized by NASA in an integrated spectroscopy strategy that will include Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Induced Florescence Spectroscopy (LIFS) for molecule and element identification on Mars Europa, and various asteroids. The instrument is to be down scaled from a dedicated rover mounted instrument into a compact unit with the same capabilities and accuracy as the larger instrument. The focus for this design is a spectrometer that utilizes Raman spectroscopy. The spectrometer has a calculated range of 218 nm wavelength spectrum with a resolution of 1.23 nm. To filter out the laser source wavelength of 532 nm the spectrometer design utilizes a 532 nm wavelength dichroic mirror and a 532 nm wavelength notch filter. The remaining scatter signal is concentrated by a 20 x microscopic objective through a 25-micron vertical slit into a 5mm diameter, 1cm focal length double concave focusing lens. The light is then diffracted by a 1600 Lines per Millimeter (L/mm) dual holographic transmission grating. This spectrum signal is captured by a 1-inch diameter double convex 3 cm focal length capture lens. An Intensified Charge Couple Device (ICCD) is placed within the initial focal cone of the capture lens and the Raman signal captured is to be analyzed through spectroscopy imaging software. This combination allows for accurate Raman spectroscopy to be achieved. The components for the spectrometer have been bench tested in a series of prototype developments based on theoretical calculations, alignment, and scaling strategies. The mounting platform is 2.5 cm wide by 8.8 cm long by 7 cm height. This platform has been tested and calibrated with various sources such as a neon light source and ruby crystal. This platform is intended to be enclosed in a ruggedized enclosure for mounting on a rover platform. The size and functionality of the Raman spectrometer allows for the rover to carry other mission critical devices. This project will be continued at NASA until the requirements are met for the expected initial 2020 launch date.

Lucas, John F.↗

The development and applications of multidimensional biomolecular spectroscopy illustrated by photosynthetic light harvesting

The parallel and synergistic developments of atomic resolution structural information, new spectroscopic methods, their underpinning formalism, and the application of sophisticated theoretical methods have led to a step function change in our understanding of photosynthetic light harvesting, the process by which photosynthetic organisms collect solar energy and supply it to their reaction centers to initiate the chemistry of photosynthesis. The new spectroscopic methods, in particular multidimensional spectroscopies, have enabled a transition from recording rates of processes to focusing on mechanism. We discuss two ultrafast spectroscopies – two-dimensional electronic spectroscopy and two-dimensional electronic-vibrational spectroscopy – and illustrate their development through the lens of photosynthetic light harvesting. Both spectroscopies provide enhanced spectral resolution and, in different ways, reveal pathways of energy flow and coherent oscillations which relate to the quantum mechanical mixing of, for example, electronic excitations (excitons) and nuclear motions. The new types of information present in these spectra provoked the application of sophisticated quantum dynamical theories to describe the temporal evolution of the spectra and provide new questions for experimental investigation. While multidimensional spectroscopies have applications in many other areas of science, we feel that the investigation of photosynthetic light harvesting has had the largest influence on the development of spectroscopic and theoretical methods for the study of quantum dynamics in biology, hence the focus of this review. We conclude with key questions for the next decade of this review.

59 BASIC BIOLOGICAL SCIENCES↗

Laser spectroscopy for the study of exotic nuclei

Investigation into the properties and structure of unstable nuclei far from stability is a key avenue of research in modern nuclear physics. These efforts are motivated by the continual observation of unexpected structure phenomena in nuclei with unusual proton-to-neutron ratios. In recent decades, laser spectroscopy techniques have made significant contributions in our understanding of exotic nuclei in different mass regions encompassing almost the entire nuclear chart. This is achieved through determining multiple fundamental properties of nuclear ground and isomeric states, such as nuclear spins, magnetic dipole and electric quadrupole moments and charge radii, via the measurement of hyperfine structures and isotope shifts in the atomic or ionic spectra of the nuclei of interest. These properties offer prominent tests of recently developed state-of-the-art nuclear theory and help to stimulate new developments in improving the many-body methods and nucleon–nucleon interactions at the core of these models. With the aim of exploring more exotic short-lived nuclei located ever closer to the proton and neutron driplines, laser spectroscopy techniques, with their continuous technological developments towards higher resolution and higher sensitivity, are extensively employed at current- and next-generation radioactive ion beam facilities worldwide. Ongoing efforts in parallel promise to improve the availability of these even more exotic species at next-generation facilities. Very recently, an innovative application of laser spectroscopy on molecules containing short-lived nuclei has been demonstrated offering additional opportunities for several fields of research, e.g. fundamental symmetry studies and astrophysics. Here, in this review, the basic nuclear properties measurable with laser spectroscopy will be introduced. How these observables are associated with nuclear structure and nucleon–nucleon interactions will be discussed. Following this, a general overview of different laser spectroscopy methods will be given with particular emphasis on technical advancements reported in recent years. The main focus of this article is to review the numerous highlights that have resulted from studying exotic nuclei in different mass regions with laser spectroscopy techniques since the last edition in this series. Finally, the challenges facing the field in addition to future opportunities will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultra-sensitive high-precision spectroscopy of a fast molecular ion beam

Direct spectroscopy of a fast molecular ion beam offers many advantages over competing techniques, including the generality of the approach to any molecular ion, the complete elimination of spectral confusion due to neutral molecules, and the mass identification of individual spectral lines. The major challenge is the intrinsic weakness of absorption or dispersion signals resulting from the relatively low number density of ions in the beam. Direct spectroscopy of an ion beam was pioneered by Saykally and co-workers in the late 1980s, but has not been attempted since that time. Here, we present the design and construction of an ion beam spectrometer with several improvements over the Saykally design. The ion beam and its characterization have been improved by adopting recent advances in electrostatic optics, along with a time-of-flight mass spectrometer that can be used simultaneously with optical spectroscopy. As a proof of concept, a noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) setup with a noise equivalent absorption of {approx}2 x 10{sup -11} cm{sup -1} Hz{sup -1/2} has been used to observe several transitions of the Meinel 1-0 band of N{sub 2}{sup +} with linewidths of {approx}120 MHz. An optical frequency comb has been used for absolute frequency calibration of transition frequencies to within {approx}8 MHz. This work represents the first direct spectroscopy of an electronic transition in an ion beam, and also represents a major step toward the development of routine infrared spectroscopy of rotationally cooled molecular ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles (Final Report)

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C.; Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers; Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C; Mixtures of Fe2O3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm; Copper oxides did not yield suitable signals at elevated temperatures; The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗