Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Report of the Basic Energy Sciences Workshop on the Future of Electron Sources, September 8-9, 2016

Electron sources represent an enabling technology for all cutting-edge applications of electron accelerators, two of the most notable ones being the X-ray free electron laser (FEL) and the electron microscope. FELs were enabled by the development of high-brightness electron sources, and they have changed the paradigm for a broad spectrum of scientific research. Electron microscopes have achieved sub-Å spatial resolution through the introduction of a cold field-emitter and aberration correction optics. Further development of these tools to atomic spatial and temporal resolutions is needed to advance atomic and molecular sciences to new levels of precision. Though the field of electron sources is quite mature, both revolutionary and evolutionary advances in electron sources are needed. On September 8-9, 2016, BES sponsored a Workshop on the Future of the Electron Source at SLAC National Accelerator Laboratory. The goal of the workshop was to define the electron source requirements for future XFELs, UED and UEM, and to identify future research and development (R&D) opportunities. More than sixty participants from U.S. national laboratories, academia, and international institutions attended the workshop. The workshop started with four plenary talks covering the status of electron sources, and highlighting the most urgent needs of future X-ray and electron scattering facilities. The talks made it evident that significant progress in electron sources will not only maximize the impact of current facilities, but also enable novel capabilities that can help maintain the U.S. leadership in X-ray and electron-based scattering instrumentation. Four breakout panels addressed the major technical areas of electron sources: (1) science and technology of electron generation, (2) continuous wave (CW) electron sources, (3) pulsed electron sources, and (4) exotic electron sources. Prior to the workshop, the panel co-chairs polled the panelists and other experts in the field and invited them to make recommendations on the most promising ways to advance the field of electron sources. During the workshop, each panel reviewed the proposals and novel ideas submitted. These summaries of the discussions on scientific needs and instrument requirements and their recommendations form the basis of this report.

43 PARTICLE ACCELERATORS↗

Highly Stripped Ion Sources for MeV Ion Implantation

Original technical objectives of CRADA number PVI C-03-09 between BNL and Poole Ventura, Inc. (PVI) were to develop an intense, high charge state, ion source for MeV ion implanters. Present day high-energy ion implanters utilize low charge state (usually single charge) ion sources in combination with rf accelerators. Usually, a MV LINAC is used for acceleration of a few rnA. It is desirable to have instead an intense, high charge state ion source on a relatively low energy platform (de acceleration) to generate high-energy ion beams for implantation. This de acceleration of ions will be far more efficient (in energy utilization). The resultant implanter will be smaller in size. It will generate higher quality ion beams (with lower emittance) for fabrication of superior semiconductor products. In addition to energy and cost savings, the implanter will operate at a lower level of health risks associated with ion implantation. An additional aim of the project was to producing a product that can lead to long­ term job creation in Russia and/or in the US. R&D was conducted in two Russian Centers (one in Tomsk and Seversk, the other in Moscow) under the guidance ofPVI personnel and the BNL PI. Multiple approaches were pursued, developed, and tested at various locations with the best candidate for commercialization delivered and tested at on an implanter at the PVI client Axcelis. Technical developments were exciting: record output currents of high charge state phosphorus and antimony were achieved; a Calutron-Bemas ion source with a 70% output of boron ion current (compared to 25% in present state-of-the-art). Record steady state output currents of higher charge state phosphorous and antimony and P ions: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA) and 16.2, 7.6, 3.3, and 2.2 pmA of Sb{sup 3+} Sb {sup 4 +}, Sb{sup 5+}, and Sb{sup 6+} respectively. Ultimate commercialization goals did not succeed (even though a number of the products like high charge state phosphorus and antimony could have resulted in a lower power consumption of 30 kW/implanter) for the following reasons (which were discovered after R&D completion): record output of high charge state phosphorous would have thermally damage wafers; record high charge state of antimony requires tool (ion implanting machine in ion implantation jargon) modification, which did not make economic sense due to the small number of users. Nevertheless, BNL has benefited from advances in high-charge state ion generation, due to high charge state ions need for RHIC preinjection. High fraction boron ion was delivered to PVI client Axcelis for retrofit and implantation testing; the source could have reduced beam preinjector power consumption by a factor of 3.5. But, since the source generated some lithium (though in miniscule amounts); last minute decision was made not to employ the source in implanters. R&D of novel transport and gasless plasmaless deceleration, as well as decaborane molecular ion source to mitigate space charge problems in low energy shallow ion implantation was also conducted though results were not yet ready for commercialization. Future work should be focused on gasless plasmaless transport and deceleration as well as on molecular ions due to their significance to low energy, shallow implantation; which is the last frontier of ion implantation. To summarize the significant accomplishments: 1. Record steady state output currents of high charge state phosphorous, P, ions in particle milli-Ampere: P{sup 2+} (8.6 pmA), P{sup 3+} (1.9 pmA), and P{sup 4+} (0.12 pmA). 2. Record steady state output currents of high charge state antimony, Sb, ions in particle milli-Ampere: Sb{sup 3+} (16.2 pmA), Sb{sup 4+} (7.6 pmA), Sb{sup 5+} (3.3 pmA), and Sb{sup 6+} (2.2 pmA). 3. 70% output of boron ion current (compared to 25% in present state-of-the-art) from a Calutron-Bemas ion source. These accomplishments have the potential of benefiting the semiconductor manufacturing industry by lowering power consumption by as much as 30 kW per ion implanter. Major problem was meeting commercialization goals did not succeed for the following reasons (which were discovered after R&D completion): record output of high charge state phosphorous would have thermally damage wafers; record high charge state of antimony requires tool (ion implanting machine in ion implantation jargon) modification, which did not make economic sense due to the small number of users. High fraction boron ion was delivered to PVI client Axcelis for retrofit and implantation testing; the source could have reduced beam preinjector power consumption by a factor of 3.5. But, since the source generated some lithium (though in miniscule amounts); last minute decision was made not to employ the source in implanters. An additional noteworthy reason for failure to commercialize is the fact that the ion implantation manufacturing industry had been in a very deep bust cycle. BNL, however, has benefited from advances in high-charge state ion generation, due to the need high charge state ions in some RHIC preinjectors. Since the invention of the transistor, the trend has been to miniaturize semiconductor devices. As semiconductors become smaller (and get miniaturized), ion energy needed for implantation decreases, since shallow implantation is desired. But, due to space charge (intra-ion repulsion) effects, forming and transporting ion beams becomes a rather difficult task. A few small manufacturers of low quality semiconductors use plasma immersion to circumvent the problem. However, in plasma immersion undesired plasma impurity ions are also implanted; hence, the quality of those semiconductors is poor. For high quality miniature semiconductor manufacturing, pure, low energy ion beams are utilized. But, low energy ion implanters are characterized by low current (much lower than desirable) and, therefore, low production rates. Consequently, increasing the current of pure low energy ion beams is of paramount importance to the semiconductor industry. Basically, the semiconductor industry needs higher currents and purer ion low energy beams. Therefore R&D of novel transport and gasless plasmaless deceleration, as well as decaborane molecular ion source to mitigate space charge problems in low energy shallow ion implantation was also conducted though results were not yet ready for commercialization. Future work should be focused on gasless plasmaless transport and deceleration as well as cin molecular ions due to their significance to low energy, shallow implantation, which is the last frontier of ion implantation.

99 GENERAL AND MISCELLANEOUS↗

Double-coronal X-Ray and Microwave Sources Associated with a Magnetic Breakout Solar Eruption

Double-coronal hard X-ray (HXR) sources are believed to be critical observational evidence of bi-directional energy release through magnetic reconnection in large-scale current sheets in solar flares. Here, we present a study on double-coronal sources observed in both HXR and microwave regimes, revealing new characteristics distinct from earlier reports. This event is associated with a footpoint-occulted X1.3-class flare (2014 April 25, starting at 00:17 UT) and a coronal mass ejection that were likely triggered by the magnetic breakout process, with the lower source extending upward from the top of the partially occulted flare loops and the upper source co-incident with rapidly squeezing-in side lobes (at a speed of ∼250 km s{sup −1} on both sides). The upper source can be identified at energies as high as 70–100 keV. The X-ray upper source is characterized by flux curves that differ from those of the lower source, a weak energy dependence of projected centroid altitude above 20 keV, a shorter duration, and an HXR photon spectrum slightly harder than those of the lower source. In addition, the microwave emission at 34 GHz also exhibits a similar double-source structure and the microwave spectra at both sources are in line with gyrosynchrotron emission given by non-thermal energetic electrons. These observations, especially the co-incidence of the very-fast squeezing-in motion of side lobes and the upper source, indicate that the upper source is associated with (and possibly caused by) this fast motion of arcades. This sheds new light on the origin of the corona double-source structure observed in both HXRs and microwaves.

79 ASTRONOMY AND ASTROPHYSICS↗

A Search for FRB 121102-like Persistent Radio-luminous Sources—Candidates and Implications for the FRB Rate and Searches

The localization of the repeating fast radio burst (FRB), FRB 121102, suggests that it is associated with a persistent radio-luminous compact source in the FRB host galaxy. Using the FIRST radio catalog, I present a search for luminous persistent sources in nearby galaxies, with radio luminosities >10% of the FRB 121102 persistent source luminosity. The galaxy sample contains about 30% of the total galaxy g-band luminosity within <108 Mpc, in a footprint of 10,600 deg{sup 2}. After rejecting sources likely due to active galactic nuclei activity or background sources, I am left with 11 candidates that are presumably associated with galactic disks or star-formation regions. At least some of these candidates are likely to be due to chance alignment. In addition, I find 85 sources within 1{sup ′′} of galactic nuclei. Assuming that the radio persistent sources are not related to galactic nuclei and that they follow the galaxy g-band light, the 11 sources imply a 95% confidence upper limit on the space density of luminous persistent sources of ≲5×10{sup −5} Mpc{sup −3}, and that at any given time only a small fraction of galaxies host a radio-luminous persistent source (≲10{sup −3} L{sub ∗}{sup −1}). Assuming a persistent source lifetime of 100 years, this implies a birth rate of ≲5×10{sup −7} yr{sup −1} Mpc{sup −3}. Given the FRB volumetric rate, and assuming that all FRBs repeat and are associated with persistent radio sources, this sets a lower limit on the rate of FRB events per persistent source of ≳0.8 yr{sup −1}. I argue that these 11 candidates are good targets for FRB searches and I estimate the FRB event rate from these candidates.

79 ASTRONOMY AND ASTROPHYSICS↗

Restrictive loads powered by separate or by common electrical sources

In designing a multiple load electrical system, the designer may wish to compare the performance of two setups: a common electrical source powering all loads, or separate electrical sources powering individual loads. Three types of electrical sources: an ideal voltage source, an ideal current source, and solar cell source powering resistive loads were analyzed for their performances in separate and common source systems. A mathematical proof is given, for each case, indicating the merit of the separate or common source system. The main conclusions are: (1) identical resistive loads powered by ideal voltage sources perform the same in both system setups, (2) nonidentical resistive loads powered by ideal voltage sources perform the same in both system setups, (3) nonidentical resistive loads powered by ideal current sources have higher performance in separate source systems, and (4) nonidentical resistive loads powered by solar cells have higher performance in a common source system for a wide range of load resistances.

Appelbaum, J.↗

The Chandra Deep Field-South Survey: 7 Ms Source Catalogs

We present X-ray source catalogs for the approx. 7 Ms exposure of the Chandra Deep Field-South (CDF-S), which covers a total area of 484.2 arcmin2. Utilizing WAVDETECT for initial source detection and ACIS Extract for photometric extraction and significance assessment, we create a main source catalog containing 1008 sources that are detected in up to three X-ray bands: 0.5-7.0 keV, 0.5-2.0 keV, and 2-7 keV. A supplementary source catalog is also provided, including 47 lower-significance sources that have bright (Ks < or = 23) near-infrared counterparts. We identify multiwavelength counterparts for 992 (98.4%) of the main-catalog sources, and we collect redshifts for 986 of these sources, including 653 spectroscopic redshifts and 333 photometric redshifts. Based on the X-ray and multiwavelength properties, we identify 711 active galactic nuclei (AGNs) from the main-catalog sources. Compared to the previous approx. 4 Ms CDF-S catalogs, 291 of the main-catalog sources are new detections. We have achieved unprecedented X-ray sensitivity with average flux limits over the central approx. 1 arcmin2 region of 1.9 x 10(exp -17), 6.4 x 10(exp -18), and 2.7 x 10(exp -17) erg/sq cm/s in the three X-ray bands, respectively. We provide cumulative number-count measurements observing, for the first time, that normal galaxies start to dominate the X-ray source population at the faintest 0.5-2.0 keV flux levels. The highest X-ray source density reaches approx. 50,500/sq deg, and 47% +/- 4 of these sources are AGNs (approx. 23,900/sq deg).

cosmology: observations – diffuse radiation – ↗

Newly Identified Climatically and Environmentally Significant High-Latitude Dust Sources

Dust particles from high latitudes have a potentially large local, regional, and global significance to climate and the environment as short-lived climate forcers, air pollutants, and nutrient sources. Identifying the locations of local dust sources and their emission, transport, and deposition processes is important for understanding the multiple impacts of high-latitude dust (HLD) on the Earth’s systems. Here, we identify, describe, and quantify the source intensity (SI) values, which show the potential of soil surfaces for dust emission scaled to values 0 to 1 concerning globally best productive sources, using the Global Sand and Dust Storms Source Base Map (G-SDS-SBM). This includes 64 HLD sources in our collection for the northern (Alaska, Canada, Denmark, Greenland, Iceland, Svalbard, Sweden, and Russia) and southern (Antarctica and Patagonia) high latitudes. Activity from most of these HLD sources shows seasonal character. It is estimated that high-latitude land areas with higher (SI ≥ 0.5), very high (SI ≥ 0.7), and the highest potential (SI ≥ 0.9) for dust emission cover > 1 670 000 km 2 , > 560 000 km 2 , and > 240 000 km 2 , respectively. In the Arctic HLD region (≥ 60◦ N), land area with SI ≥ 0.5 is 5.5 % (1 035 059 km 2 ), area with SI ≥ 0.7 is 2.3 % (440 804 km 2 ), and area with SI ≥ 0.9 is 1.1 % (208 701 km 2 ). Minimum SI values in the northern HLD region are about 3 orders of magnitude smaller, indicating that the dust sources of this region greatly depend on weather conditions. Our spatial dust source distribution analysis modeling results showed evidence supporting a northern HLD belt, defined as the area north of 50◦ N, with a “transitional HLD-source area” extending at latitudes 50–58◦ N in Eurasia and 50–55◦ N in Canada and a “cold HLD-source area” including areas north of 60◦ N in Eurasia and north of 58◦ N in Canada, with currently “no dust source” area between the HLD and low-latitude dust (LLD) dust belt, except for British Columbia. Using the global atmospheric transport model SILAM, we estimated that 1.0 % of the global dust emission originated from the high-latitude regions. About 57 % of the dust deposition in snow- and ice-covered Arctic regions was from HLD sources. In the southern HLD region, soil surface conditions are favorable for dust emission during the whole year. Climate change can cause a decrease in the duration of snow cover, retreat of glaciers, and an increase in drought, heatwave intensity, and frequency, leading to the increasing frequency of topsoil conditions favorable for dust emission, which increases the probability of dust storms. Our study provides a step forward to improve the representation of HLD in models and to monitor, quantify, and assess the environmental and climate significance of HLD.

high latitude dust↗

Special Analysis for the Disposal of the Oak Ridge National Laboratory General Radioactive Sources Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

This special analysis (SA) evaluates whether the Oak Ridge National Laboratory (ORNL) General Radioactive Sources waste stream (ORNLSOURCES01, Revision 3) is suitable for disposal by shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site (NNSS). The ORNL General Radioactive Sources waste stream consists of sealed sources and solid radioactive sources that are no longer needed (ORNL 2015). The ORNL General Radioactive Sources waste stream required a special analysis because 26 radionuclides exceeded the NNSS Waste Acceptance Criteria (WAC) Action Levels (U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office [NNSA/NFO] 2015). However, review of the generator’s method to calculate waste concentration indicates that the concentrations are significantly overestimated. Waste concentrations are recalculated in this analysis using a list of individual sources provided by the generator. One radionuclide, radium-226 (226Ra), still exceeds its action level and a Special Analysis (SA) is required. The results indicate that all performance objectives can be met with disposal of the ORNL General Radioactive Sources in a SLB trench. Addition of the ORNL General Radioactive Sources inventory slightly increases the 222Rn flux density. The maximum mean and 95th percentile flux density remain less than the performance objective throughout the compliance period. The ORNL General Radioactive Sources waste stream had no significant effect on the maximum mean and 95th percentile for all other performance assessment results. The ORNL General Radioactive Sources waste stream is suitable for disposal by SLB at the Area 5 RWMS. However, because the activity concentrations on the waste profile sheet are significantly overestimated, approval of the sheet could potentially allow the disposal of high activity radiation sources. To ensure the generator does not include large radiation sources in its waste stream, a control is recommended on the maximum individual source activity from this generator.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Security of Mobile Radiological Sources: Overview of Industry Applied Technologies

Small radiological sources used in industrial settings recurrently require transit between job sites. Securing these sources, while stationary, can be addressed with standard security approaches and equipment. Transport of these sources increases the risk and complexity of managing and maintaining control of these sources. Implementing methodologies to securely monitor and locate sources improves response and resolution of anomalous events during transit. The Mobile Source Transit Security (MSTS) system was developed to improve security and provide situational awareness of these mobile sources throughout their job cycle. The MSTS development effort focused on creating a set of systems that could be successfully implemented in industrial radiography and well-logging applications. The MSTS team worked to address source presence and location through use and storage. The MSTS system monitors radiological sources as they move from the base of operations to the job site and back. The system provides near-real-time monitoring of the mobile source location and status and early notification of source loss or theft by transmitting operational status and alerting anomalous conditions over telematic links worldwide. The MSTS system can trigger an armed response or initiation of search and recovery operations and will automatically alert management and responsible staff if a radioactive source is lost or stolen whether it is on-site, in transport, or in storage.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Current Situation for Management of Disused Sealed Radioactive Sources in Japan - 13025

As for the Sealed Radioactive Source currently used in Japan, many of them are imported from overseas. The U.S., Canada, Germany, the Netherlands, Belgium and Czech Republic are the main exporting States. Many of disused sealed radioactive sources are being returned to exporting States. The sealed radioactive sources which cannot be returned to exporting States are appropriately kept in the domestic storage facility. So, there are not main problem on the long term management of disused sealed radioactive sources in Japan. However, there are some difficulties on repatriate. One is reservation of a means of transport. The sea mail which conveys radioactive sources owing to reduction of movement of international cargo is decreasing in number. And there is a denial of shipment. Other one is that the manufacturer has already resigned from the work and cannot return disused sealed radioactive sources, or a manufacturer cannot specify and disused sources cannot be returned. The disused sealed radioactive source which cannot be repatriated is a little in term of radioactivity. As for the establishment of national measure of final disposal facility for disused sealed radioactive sources, in Japan, it is not yet installed with difficulty. Since there are many countries for which installation of a final disposal facility for disused sealed radioactive sources is difficult, the source manufacture country should respond positively to return the source which was manufactured and sold in the past. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Introducing a risk aggregation rationale for mapping risks to aquifers from point- and diffuse-sources–proof-of-concept using contamination data from industrial lagoons

Highlights: • Aquifer risk mapping is introduced for contaminants acting as point/diffuse-sources. • Innovations are framed by risk cells based on Source-Pathway-Receptor-Source (SPRC). • Point-source (Risk Cell 1) and diffuse-source (Risk Cell 2) use sets of algorithms. • Algorithms include MODPATH, DRASTIC, GWPI and are integrated on a modular basis. • Risk Cells 1/2 are aggregated giving fit-for-purpose results as proof-of-concept. - Abstract: Proof-of-concept for a methodology is presented on mapping risks to aquifers impacted from point- and diffuse-sources, where mapping or indexing refers to relative but not absolute values. The methodology is generic but tested by investigating impacts of a risk exposure from industrial wastewater lagoons. The methodology is innovative for using the qualitative Source-Pathways-Receptors-Consequences (SPRC) framework to aggregate risks from both point-sources and diffuse-sources through breaking down a study area into SPRC risk cells. In this paper, two risk cells are required as: (i) Cell 1 is directly impacted from a point-source; and (ii) Cell 2 is impacted by diffuse-sources to slowly contaminate the aquifer by infiltration over a large area. Indexing both types of risk cells generically comprise three tiered processes: (i) binary indexing establishes if a grid cell is at a potential risk or not; (ii) graded indexing measures the strength of the risk pathways from source to receptors; and (iii) local indexing measures intrinsic potentials at the grid cell to propagate the risk. These three processes apply to both point- and diffuse-sources but with different mathematical formulations. The proof-of-concept for the methodology of risk aggregation using the SPRC framework is supported by results of a study area, in which a set of performance metrics are used by comparing with the measurements. The results are found to be fit-for-purpose for serving as proactive management tools and to provide a deeper insight into potential impacts of adverse effects.

54 ENVIRONMENTAL SCIENCES↗

X-RAY POINT-SOURCE POPULATIONS CONSTITUTING THE GALACTIC RIDGE X-RAY EMISSION

Apparently diffuse X-ray emission has been known to exist along the central quarter of the Galactic Plane since the beginning of X-ray astronomy; this is referred to as the Galactic Ridge X-ray emission (GRXE). Recent deep X-ray observations have shown that numerous X-ray point sources account for a large fraction of the GRXE in the hard band (2-8 keV). However, the nature of these sources is poorly understood. Using the deepest X-ray observations made in the Chandra bulge field, we present the result of a coherent photometric and spectroscopic analysis of individual X-ray point sources for the purpose of constraining their nature and deriving their fractional contributions to the hard-band continuum and Fe K line emission of the GRXE. Based on the X-ray color-color diagram, we divided the point sources into three groups: A (hard), B (soft and broad spectrum), and C (soft and peaked spectrum). The group A sources are further decomposed spectrally into thermal and non-thermal sources with different fractions in different flux ranges. From their X-ray properties, we speculate that the group A non-thermal sources are mostly active galactic nuclei and the thermal sources are mostly white dwarf (WD) binaries such as magnetic and non-magnetic cataclysmic variables (CVs), pre-CVs, and symbiotic stars, whereas the group B and C sources are X-ray active stars in flares and quiescence, respectively. In the log N-log S curve of the 2-8 keV band, the group A non-thermal sources are dominant above Almost-Equal-To 10{sup -14} erg cm{sup -2} s{sup -1}, which is gradually taken over by Galactic sources in the fainter flux ranges. The Fe K{alpha} emission is mostly from the group A thermal (WD binaries) and the group B (X-ray active stars) sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation Safety of Sealed Radioactive Sources

Sealed radioactive sources are used in a wide variety of occupational settings and under differing regulatory/licensing structures. The definition of a sealed radioactive source varies between US regulatory authorities and standard-setting organizations. Potential problems with sealed sources cover a range of risks and impacts. The loss of control of high activity sealed sources can result in very high or even fatal doses to members of the public who come in contact with them. Sources that are not adequately sealed, and that fail, can cause spread of contamination and potential intake of radioactive material. There is also the possibility that sealed sources may be (or threatened to be) used for terrorist purposes and disruptive opportunities. Until fairly recently, generally-licensed sealed sources and devices received little, if any, regulatory oversight, and were often forgotten, lost or unaccounted for. Nonetheless, generally licensed devices can contain fairly significant quantities of radioactive material and there is some potential for exposure if a device is treated in a way that it was never designed. Industrial radiographers use and handle high activity and/or high-dose rate sealed sources in the field with a high degree of independence and minimal regulatory oversight. Failure to follow operational procedures and properly handle radiography sources can and has resulted in serious injuries and death. Industrial radiographers have experienced a disproportionately large fraction of incidents that result in unintended exposure to radiation. Sources do not have to contain significant quantities of radioactive material to cause problems in the event of their failure. A loss of integrity can cause the spread of contamination and potential exposure to workers and members of the public. The NCRP has previously provided recommendations on select aspects of sealed source programs. Future efforts to provide recommendations for sealed source programs are discussed.

radioactive material↗

Characteristics of elliptical sources in BEAMnrc Monte Carlo system: Implementation and application

Recently, several papers noticed that the electron focal spot of a linear accelerator (linac) could be elliptical which would cause dosimetric discrepancies between measurements and Monte Carlo simulations. To resolve the mismatch, two elliptical source models were developed in BEAMnrc code. The first was a parallel beam elliptical source with uniform distribution where the shape of the source was primarily considered. The other was a parallel beam elliptical source with Gaussian distribution whose source distribution follows the normal distribution. To validate the elliptical source models, uniform and Gaussian electron beams were impinged on a thin air target. Both models successfully reproduced the elliptical shapes and source distributions. Then, this study investigated the characteristics of the elliptical Gaussian source for a 6 MV photon beam in a Varian 21EX linac. The linac head model was implemented in the BEAMnrc/EGSnrc system and commissioned by comparing the lateral and depth dose profiles to the ion chamber measurements acquired from the annual quality assurance (QA). It was found that the circular Gaussian beam with 6 MeV/0.2 cm full width half maximum (FWHM) produces the best matches to the QA data. To explore the characteristics of the elliptical Gaussian source, this study employed an elliptical Gaussian electron source with 0.1 cm FWHM in the x axis and 0.2 cm FWHM in the y axis which was incident on the target of the linac head. Two circular Gaussian beams with 0.1 and 0.2 cm FWHM were employed to compare the differences between circular and elliptical sources. For all the sources, planar and energy fluences were acquired and analyzed. This study also compared the lateral and depth dose profiles in a water phantom by using a DOSXYZnrc user code. In results, a constricted shoulder effect was observed in both planar and energy fluence plots when the FWHM value was increased and the field size is larger than 30x30 cm{sup 2}. The same effect was also noticed in the lateral dose profiles, while the depth dose profile did not vary much.

43 PARTICLE ACCELERATORS↗

Study of encapsulated {sup 170}Tm sources for their potential use in brachytherapy

Purpose: High dose-rate (HDR) brachytherapy is currently performed with {sup 192}Ir sources, and {sup 60}Co has returned recently into clinical use as a source for this kind of cancer treatment. Both radionuclides have mean photon energies high enough to require specific shielded treatment rooms. In recent years, {sup 169}Yb has been explored as an alternative for HDR-brachytherapy implants. Although it has mean photon energy lower than {sup 192}Ir, it still requires extensive shielding to deliver treatment. An alternative radionuclide for brachytherapy is {sup 170}Tm (Z=69) because it has three physical properties adequate for clinical practice: (a) 128.6 day half-life, (b) high specific activity, and (c) mean photon energy of 66.39 keV. The main drawback of this radionuclide is the low photon yield (six photons per 100 electrons emitted). The purpose of this work is to study the dosimetric characteristics of this radionuclide for potential use in HDR-brachytherapy. Methods: The authors have assumed a theoretical {sup 170}Tm cylindrical source encapsulated with stainless steel and typical dimensions taken from the currently available HDR {sup 192}Ir brachytherapy sources. The dose-rate distribution was calculated for this source using the GEANT4 Monte Carlo (MC) code considering both photon and electron {sup 170}Tm spectra. The AAPM TG-43 U1 brachytherapy dosimetry parameters were derived. To study general properties of {sup 170}Tm encapsulated sources, spherical sources encapsulated with stainless steel and platinum were also studied. Moreover, the influence of small variations in the active core and capsule dimensions on the dosimetric characteristics was assessed. Treatment times required for a {sup 170}Tm source were compared to those for {sup 192}Ir and {sup 169}Yb for the same contained activity. Results: Due to the energetic beta spectrum and the large electron yield, the bremsstrahlung contribution to the dose was of the same order of magnitude as from the emitted gammas and characteristic x rays. Moreover, the electron spectrum contribution to the dose was significant up to 4 mm from the source center compared to the photon contribution. The dose-rate constant {Lambda} of the cylindrical source was 1.23 cGy h{sup -1} U{sup -1}. The behavior of the radial dose function showed promise for applications in brachytherapy. Due to the electron spectrum, the anisotropy was large for r<6 mm. Variations in manufacturing tolerances did not significantly influence the final dosimetry data when expressed in cGy h{sup -1} U{sup -1}. For typical capsule dimensions, maximum reference dose rates of about 0.2, 10, and 2 Gy min{sup -1} would then be obtained for {sup 170}Tm, {sup 192}Ir, and {sup 169}Yb, respectively, resulting in treatment times greater than those for HDR {sup 192}Ir brachytherapy. Conclusions: The dosimetric characteristics of source designs exploiting the low photon energy of {sup 170}Tm were studied for potential application in HDR-brachytherapy. Dose-rate distributions were obtained for cylindrical and simplified spherical {sup 170}Tm source designs (stainless steel and platinum capsule materials) using MC calculations. Despite the high activity of {sup 170}Tm, calculated treatment times were much longer than for {sup 192}Ir.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling a Hypothetical {sup 170}Tm Source for Brachytherapy Applications

Purpose: To perform absorbed dose calculations based on Monte Carlo simulations for a hypothetical {sup 170}Tm source and to investigate the influence of encapsulating material on the energy spectrum of the emitted electrons and photons. Methods: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of {sup 170}Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models. A hypothetical {sup 170}Tm source based on the Flexisource brachytherapy design with the active core set as a pure thulium cylinder (length 3.5 mm and diameter 0.6 mm) and different cylindrical source encapsulations (length 5 mm and thickness 0.125 mm) constructed of titanium, stainless-steel, gold, or platinum were simulated. The radial dose function for the line source approximation was calculated following the TG-43U1 formalism for the stainless-steel encapsulation. Results: For the titanium and stainless-steel encapsulation, 94% of the total bremsstrahlung is produced inside the core, 4.8 and 5.5% in titanium and stainless-steel capsules, respectively, and less than 1% in water. For the gold capsule, 85% is produced inside the core, 14.2% inside the gold capsule, and a negligible amount (<1%) in water. Platinum encapsulation resulted in bremsstrahlung effects similar to those with the gold encapsulation. The range of the beta particles decreases by 1.1 mm with the stainless-steel encapsulation compared to the bare source but the tissue will still receive dose from the beta particles several millimeters from the source capsule. The gold and platinum capsules not only absorb most of the electrons but also attenuate low energy photons. The mean energy of the photons escaping the core and the stainless-steel capsule is 113 keV while for the gold and platinum the mean energy is 160 keV and 165 keV, respectively. Conclusions: A {sup 170}Tm source is primarily a bremsstrahlung source, with the majority of bremsstrahlung photons being generated in the source core and experiencing little attenuation in the source encapsulation. Electrons are efficiently absorbed by the gold and platinum encapsulations. However, for the stainless-steel capsule (or other lower Z encapsulations) electrons will escape. The dose from these electrons is dominant over the photon dose in the first few millimeter but is not taken into account by current standard treatment planning systems. The total energy spectrum of photons emerging from the source depends on the encapsulation composition and results in mean photon energies well above 100 keV. This is higher than the main gamma-ray energy peak at 84 keV. Based on our results, the use of {sup 170}Tm as a brachytherapy source presents notable challenges.

07 ISOTOPE AND RADIATION SOURCES↗

Determination of transit dose profile for a {sup 192}Ir HDR source

Purpose: Several studies have reported methodologies to calculate and correct the transit dose component of the moving radiation source for high dose rate (HDR) brachytherapy planning systems. However, most of these works employ the average source speed, which varies significantly with the measurement technique used, and does not represent a realistic speed profile, therefore, providing an inaccurate dose determination. In this work, the authors quantified the transit dose component of a HDR unit based on the measurement of the instantaneous source speed to produce more accurate dose values. Methods: The Nucletron microSelectron-HDR Ir-192 source was characterized considering the Task Group 43 (TG-43U1) specifications. The transit dose component was considered through the calculation of the dose distribution using a Monte Carlo particle transport code, MCNP5, for each source position and correcting it by the source speed. The instantaneous source speed measurements were performed in a previous work using two optical fibers connected to a photomultiplier and an oscilloscope. Calculated doses were validated by comparing relative dose profiles with those obtained experimentally using radiochromic films. Results: TG-43U1 source parameters were calculated to validate the Monte Carlo simulations. These agreed with the literature, with differences below 1% for the majority of the points. Calculated dose profiles without transit dose were also validated by comparison with ONCENTRA{sup Registered-Sign} Brachy v. 3.3 dose values, yielding differences within 1.5%. Dose profiles obtained with MCNP5 corrected using the instantaneous source speed profile showed differences near dwell positions of up to 800% in comparison to values corrected using the average source speed, but they are in good agreement with the experimental data, showing a maximum discrepancy of approximately 3% of the maximum dose. Near a dwell position the transit dose is about 22% of the dwell dose delivered by the source dwelling 1 s and reached 104.0 cGy per irradiation in a hypothetical clinical case studied in this work. Conclusions: The present work demonstrated that the transit dose correction based on average source speed fails to accurately correct the dose, indicating that the correct speed profile should be considered. The impact on total dose due to the transit dose correction near the dwell positions is significant and should be considered more carefully in treatments with high dose rate, several catheters, multiple dwell positions, small dwell times, and several fractions.

60 APPLIED LIFE SCIENCES↗

A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by different investigators. MC results were then compared against dose calculated using TG-43 and MBDCA methods. Results: TG-43 and PSS datasets were generated for the generic source, the PSS data for use with the ACE algorithm. The dose-rate constant values obtained from seven MC simulations, performed independently using different codes, were in excellent agreement, yielding an average of 1.1109 ± 0.0004 cGy/(h U) (k = 1, Type A uncertainty). MC calculated dose-rate distributions for the two plans were also found to be in excellent agreement, with differences within type A uncertainties. Differences between commercial MBDCA and MC results were test, position, and calculation parameter dependent. On average, however, these differences were within 1% for ACUROS and 2% for ACE at clinically relevant distances. Conclusions: A hypothetical, generic HDR {sup 192}Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between TPSs.

07 ISOTOPE AND RADIATION SOURCES↗