Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

The Planetary Protection Strategy of Mars Sample Return’s Earth Return Orbiter Mission

The Mars Sample Return campaign aims to use three flight missions and one ground element to safely bring rock cores, regolith and atmospheric samples from the surface of Mars to Earth to answer key questions about the geologic and climate history of Mars, including the potential for ancient life. Since its landing in Jezero Crater in 2021, the first mission, NASA’s Mars 2020, has collected a number of samples on the crater floor and on the delta using the Perseverance rover. Subsequent missions would recover the sealed sample tubes, launch them into Mars orbit, and transport them back to Earth. The ground element would be a high-containment facility that would isolate and protect the samples during initial sample characterization, which would include sample safety assessments and time-sensitive scientific investigations. These elements are currently in the planning and design stages of development, and represent an international effort of NASA, the European Space Agency (ESA), and many industry partners. The work presented here provides an overview of the planetary protection strategy of the third flight mission, the ESA-led Earth Return Orbiter (ERO), which hosts the NASA-provided Capture, Containment, and Return System (CCRS). ERO-CCRS would capture the container with up to 30 sealed tubes previously put in Martian orbit, contain them in redundant containers to ensure that no potentially hazardous Mars particles are released, and return them to Earth through an entry vehicle. Both NASA and ESA policies comply with the United Nations’ Outer Space Treaty by planning to protect Earth’s biosphere from any potential adverse effects from material returned from solar system bodies beyond the Earth-Moon system. In the conduct of Mars Sample Return, the two agencies have agreed to apply approaches consistent with their own planetary protection standards to the campaign elements each provides.

Mars Sample Return↗

The Planetary Protection Strategy of Mars Sample Return Earth Return Orbiter Mission

The Mars Sample Return campaign aims to use three flight missions and one ground element to safely bring rock cores, regolith and atmospheric samples from the surface of Mars to Earth to answer key questions about the geologic and climate history of Mars, including the potential for ancient life. Since its landing in Jezero Crater in 2021, the first mission, NASA’s Mars 2020, has collected a number of samples on the crater floor and on the delta using the Perseverance rover. Subsequent missions would recover the sealed sample tubes, launch them into Mars orbit, and transport them back to Earth. The ground element would be a high-containment facility that would isolate and protect the samples during initial sample characterization, which would include sample safety assessments and time-sensitive scientific investigations. These elements are currently in the planning and design stages of development, and represent an international effort of NASA, the European Space Agency (ESA), and many industry partners. The work presented here provides an overview of the Planetary Protection strategy of the third flight mission, the ESA-led Earth Return Orbiter (ERO), which hosts the NASA-provided Capture, Containment, and Return System (CCRS). ERO-CCRS would detect and capture the container with up to 30 sealed tubes previously put in Martian orbit, contain them in redundant containers to ensure that no potentially hazardous Mars particles are released, and return them to Earth through an entry vehicle. Both NASA and ESA policies comply with the United Nations’ Outer Space Treaty by planning to protect Earth’s biosphere from any potential adverse effects from material returned from solar system bodies beyond the Earth-Moon system. In the conduct of Mars Sample Return, the two agencies have mutually agreed to apply approaches consistent with their own planetary protection standards to the campaign elements they each provides.

mars sample return↗

Investigating the Physical Modification of the Bennu Sample During Entry, Descent, and Landing

On September 24, 2023, the OSIRIS-REx Sample Return Capsule (SRC) entered Earth’s atmosphere and landed in the Utah Test and Training Range (UTTR). Preliminary examination of the returned Bennu sample has confirmed that OSIRIS-REx sample mass exceeds the mission requirement of 60 g of material. The sample consists of particles that range from a few centimeters to microscopic fines. During the SRC’s entry, descent, and landing (EDL) sequence, it may have experienced (i) peak decelerations of 10s of g (ii) tumbling, and (iii) touchdown at approximately 10 m/s, which could have induced physical modification of the sample. In addition, the act of sampling may have altered or biased the physical properties of the collected materials. Here, we investigate the likelihood and extent of physical modification of the sample between collection and return using observations and modeling. This work addresses the mission’s hypothesis 12, which concerns, in part, the modification of the sample during collection and Earth entry.

asteroid↗

The Scientific Value of Collecting Samples From the Jezero Crater Rim

The Mars 2020 mission has been conducting ground-based investigation of the geology, habitability, and biosignature preservation potential and collecting samples for return to Earth in Jezero crater, Mars for nearly 3 years. Analysis of these samples will address outstanding questions in Mars science including potential habitability and how and why the climate the interior of the planet evolved through time. As of December 2023, samples of 4 igneous rocks of the Jezero crater floor and 9 sedimentary rocks of the Jezero fan and inner margin, remain on the rover. 15 tubes remain to be filled to enhance the diversity of the cache and broaden the scope of the science questions that can be addressed with returned sample studies. The next step in the mission is to explore the Jezero crater rim. It will be imperative to investigate and sample the diversity of crater rim rocks because they represent materials from Mars’ most ancient crust older than those sampled in Jezero crater, a diversity of geologic processes, and potential ancient habitable environments that have not yet been investigated or sampled. Ongoing mapping efforts are using orbiter data and long-distance images from Perseverance to identify and interpret the geologic context of the crater rim. Building on this effort and the broader geologic context for the crater rim put forward by previous studies, we identify diverse targets for in situ investigation and potential sampling by Mars 2020.

Mars sample return↗

The Planetary Protection Strategy of Mars Sample Return’s Earth Return Orbiter Mission

The Mars Sample Return campaign aims to use three flight missions and one ground element to safely bring rock cores, regolith and atmospheric samples from the surface of Mars to Earth to answer key questions about the geologic and climate history of Mars, including the potential for ancient life. Since its landing in Jezero Crater in 2021, the first mission, NASA’s Mars 2020, has collected a number of samples on the crater floor and on the delta using the Perseverance rover. Subsequent missions would recover the sealed sample tubes, launch them into Mars orbit, and transport them back to Earth. The ground element would be a high-containment facility that would isolate and protect the samples during initial sample characterization, which would include sample safety assessments and time-sensitive scientific investigations. These elements are currently in the planning and design stages of development, and represent an international effort of NASA, the European Space Agency (ESA), and many industry partners. The work presented here provides an overview of the planetary protection strategy of the third flight mission, the ESA-led Earth Return Orbiter, which hosts the NASA-provided Capture, Containment, and Return System. The orbiter would detect and capture the container with up to 30 sealed tubes previously put in Martian orbit, contain them in redundant containers to ensure that no potentially hazardous Mars particles are released, and return them to Earth through an entry vehicle. Both NASA and ESA policies comply with the United Nations’ Outer Space Treaty by planning to protect Earth’s biosphere from any potential adverse effects from material returned from solar system bodies beyond the Earth-Moon system. In the conduct of Mars Sample Return, the two agencies have mutually agreed to apply approaches consistent with their own planetary protection standards to the campaign elements they each provide.

Mars Sample Return↗

Towards a Robust Sampling Approach: A Computational Review and Design

As pointed out in several other works, the estimation of the reliability of the electrical grid can not be conducted without the estimation of the stochastic phenomena of electicity demand and electricity production by variable renewable sources. Therefore, sampling procedures have become integral in the design of engineering structures and analysis. Commonly referred to as Monte Carlo uncertainty analysis or integration, the general objective of these procedures is to establish specifics about the uncertainty of an output characteristic of such an engineering system, given uncertainty about its input characteristics. These sampling procedures are applied in a context in which establishing such specifics cannot be performed through other means. Variance-reduction techniques are designed to lessen the variability among estimators to estimate statistics of those output uncertainties. Importance-sampling techniques, on the other hand, are designed to reduce the number of samples needed to estimate a particular statistic—e.g., a tail probability. The combination of these approaches can reduce the computational burden considerably for a particular estimator and statistic. Importance sampling—geared and designed as it is toward improving a particular estimator—suffers, unfortunately, from the unintended consequence of reducing the performance of other estimators in terms of their variance. The objective of this paper is to offer an alternative sampling procedure where this variance does not grow unacceptably large for a suite of estimators. Moreover, it is anticipated that, with additional knowledge of how an engineering output characteristic responds to its input characteristics, tuning parameters of the input’s sampling procedure can be set to improve the output characteristic’s estimation. This work proves the effectiveness of the suggested alternative approach. Such positive outcome will lead to a decrease of the computational burden of performing stochastic optimization of integrated energy systems (e.g., components dispatch, and portfolio composition). In particular, capturing the contribution to the overall system cost of rare and unlikely events and patterns of the electricity demand and production will become less computationally expensive. This is due to the fact that the approach demonstrated here will allow the sampling of those rare occurrences more frequently without misrepresenting their probabilistic impacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Delayed-Gamma Energy Biasing with Exact Energy Sampling in MCNP 6.2.0

Characterization of delayed-particle signatures is of the utmost importance for detecting, identifying, and quantifying special nuclear material (SNM). Various non-destructive assay (NDA) techniques used in nuclear material safeguards rely on characteristic gamma-ray or neutron emissions to infer properties of a material. The all-particle, all-energy Monte-Carlo radiation transport code MCNP6 is capable of simulating delayed-particle signatures from SNM in addition to modeling the transport of emitted particles to a detector or other instrument. In some cases, NDA techniques require the measurement of low probability emissions from a given material. In physical scenarios, this problem can be bypassed by longer count-times or may be simply irrelevant due to the mass, and therefore the total activity, of the material being measured. However, when applying the Monte-Carlo method to such scenarios, sampling of low probability emissions requires a large number of histories to converge to a statistically acceptable solution. To address this issue, the delayed-neutron and gamma energy biasing feature was introduced in MCNP6 by H. Armstrong et al. in 2013 which allows the user to set up energy windows in which delayed-particle emission sampling can be adjusted. For delayed-gamma sampling, this biasing method was based on the bin-wise structure of gamma emission data for both the multi-bin gamma and line-emission sampling modes. Recent improvements have been made to the line-emission sampling algorithm which upgrade the previous mini-bin sampling treatment to an exact energy-line treatment. This upgrade was not compatible with the biasing method implemented by H. Armstrong et al. due to the sampled data no longer having a bin-wise structure in line-emission mode. For this reason the delayed-gamma energy biasing feature has been rewritten to support the exact line-sampling treatment. This paper provides a description of the delayed-gamma energy biasing (DGEB) feature in MCNP6 as well as results and discussion for a gamma-ray spectroscopy example used to demonstrate the biasing utility. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating Manual Sampling Locations for Regulatory and Emergency Response

Drinking water systems commonly use manual or grab sampling to monitor water quality, identify or confirm issues, and verify that corrective or emergency response actions have been effective. In this paper, the effectiveness of regulatory sampling locations for emergency response is explored. An optimization formulation based on the literature was used to identify manual sampling locations to maximize overall nodal coverage of the system. Results showed that sampling locations could be effective in confirming incidents for which they were not designed. When evaluating sampling locations optimized for emergency response against regulatory scenarios, the average performance was reduced by 3%–4%, while using optimized regulatory sampling locations for emergency response reduced performance by 7%–10%. Secondary constraints were also included in the formulation to ensure geographical and water age diversity with minimal impact on the performance. This work highlighted that regulatory sampling locations provide value in responding to an emergency for these networks.

54 ENVIRONMENTAL SCIENCES↗

Internet of Samples

Abstract Material samples are indispensable data sources in many natural science, social science, and humanity disciplines. More and more researchers recognize that samples collected in one discipline can be of great value for another. This has motivated organizations that manage a large number of samples to make their holdings accessible to the world. Currently, multiple projects are working to connect natural history and other samples managed by individual institutions or individuals into a universe of samples that follow FAIR principles. This poster reports the progress of the US NSF‐funded iSamples project, in the context of other efforts initiated by US DOE, DiSCCo, BCoN, and GBIF. By October 2021, we will also be able to present an iSamples prototype. We encourage individual organizations that hold material samples to get to know these projects and help shape these projects to realize the goal of a global linked sample cloud that connects all material samples and is accessible to all.

Richard, Stephen M.↗

Role of Ti Content on the Occurrence of the 3309-cm{sup –1} Peak in FTIR Absorption Spectra of Ruby Samples

The study is based on the determination of trace elements in ruby samples, Ti in particular, using laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS). The samples were then divided into three groups: high (≥ 200 ppma), moderate (100–200 ppma), and low (≤ 50 ppma) Ti content. In addition, X-ray absorption spectroscopy (XAS) was employed to confirm that the Ti oxidation state was Ti{sup 4+}. The heat experiment conditions were set at 800, 1200, and 1650°C to investigate the transformation of the –OH vibration in the FTIR spectra of ruby samples. The FTIR spectra showed that samples containing a low Ti concentration did not show the 3309-cm{sup –1} absorption peak either before or after heating at any of the designed temperatures. An obvious 3309-cm{sup –1} peak appeared only in samples with a moderate to high Ti content after heating at ≥ 1200°C. The results also suggest that, in addition of Ti{sup 4+}, the occurrence of the 3309-cm{sup –1} peak in the FTIR spectra is strongly affected by the charge compensation of –OH in Al sites, i.e., the structural –OH; thus, the structural –Ti–OH stretching in the ruby samples. Hence, for gemological identification, the 3309-cm{sup –1} peak can be applied to indicate whether a ruby has undergone heat treatment if those samples contain enough Ti ions in their structure, i.e., Ti ≥ 100 ppma. This condition is usually found in ruby samples from major deposits such as Mong Hsu and Mogok, Myanmar; Luc Yen, Vietnam; and Montopuez, Mozambique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production Procedure and Characterization of Zn-Doped Y-123 Superconducting Samples Prepared by Sol-Gel Method

The superconducting YBa{sub 2}Cu{sub 3−x}Zn{sub x}O{sub 7} (Y-123) bulk materials have been synthesized by using the sol-gel method. Samples are produced as undoped Y-123 and transition metal (Zn)-doped Y-123. Before the final heat treatment, the samples are calcined at 850 °C for 24 h. This process is repeated three times. Then, samples are sintered at 950 °C for 24 h in an air environment and at 500 °C for 5 h in an oxygen atmosphere. The synthesized products are characterized by XRD, R-T, and Vickers microhardness tester. The XRD investigation revealed that the prepared sample has an orthorhombic structure. According to XRD measurements, an orthorhombic structure has not changed with Zn doping. It was observed that undoped and Zn-doped samples have superconductivity properties by electrical measurements. T{sub c}{sup onset} is 89 K for undoped Y-123 sample, and the T{sub c}{sup onset} value decreases monotically with Zn addition. All samples show metallic behavior above T{sub c}{sup onset} temperature. As a result of Vickers microhardness measurements, it is observed that all samples have reverse indentation size effect (RISE) behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient Surrogate Model Development: Impact of Sample Size and Underlying Model Dimensions

This study compares eight surrogate-model construction approaches using computational experiments. Here, the construction approaches considered include: Artificial Neural Networks (ANNs), Automated Learning of Algebraic Models using Optimization (ALAMO), Radial Basis Networks (RBNs), Extreme Learning Machines (ELMs), Gaussian Progress Regression (GPR), Random Forests (RFs), Support Vector Regression (SVR), and Multivariate Adaptive Regression Splines. Each approach is used to construct surrogate models for predicting the outputs of thirty-four test functions. The data used to construct surrogate models were generated using Latin Hypercube Sampling (LHS), Halton and Sobol sampling methods. We studied the impact of sampling method, sample size, and challenge function characteristics on the accuracy of surrogate model predictions. Our results revealed that for smaller sample sizes, on average, surrogate models trained using the data points generated by Sobol sequences provided the best estimation for all surrogate model construction approaches. As the sample size increased, the impact of sampling methods diminished. The comparison of surrogate-modeling construction approaches at large sample sizes revealed that surrogate models trained using ANN, ALAMO, and ELM yielded smaller root mean squared error and higher adjusted R-squared values than the models trained using the rest of the approaches.

42 ENGINEERING↗

Comparison of measurement techniques and sorption of radium-226 in low and high salinity aqueous samples

Human activities have the potential to redistribute radium (Ra) in the marine environment in a manner that may necessitate monitoring or management of subsequent human or environmental exposures. There is therefore a need to identify accurate and accessible techniques for Ra measurement in high salinity samples and to describe the distribution of Ra in estuarine and marine environments, but most efforts in these areas have focused on low salinity matrices. In addition, rapid and reliable measurements are crucial for time-sensitive samples such as short-lived isotopes or emergency situations. The objective of this study is to describe the limits of detection, cost, and relative ease for measurement of Ra in both low and high salinity aqueous samples via three analytical methods: liquid scintillation counting (LSC), high purity germanium (HPGe) gamma spectrometry, and inductively coupled plasma mass spectrometry (ICP-MS). To contextualize these measurements for real-world scenarios, the partitioning of 226 Ra to substrates relevant to the marine environment was also characterized. Although HPGe detection with solid phase extraction had the lowest limit of detection for low salinity samples (0.27 Bq L −1 ), poor 226 Ra recovery for high salinity samples and high materials costs make this method prohibitive for many users. Limits of detection for high salinity samples were lower for LSC (1.28 Bq L −1 ) than for ICP-MS without dilution (11.4 Bq L −1 ), but significant and unexpected degradation of the high salinity LSC standards was observed after six months. Furthermore, our preferred measurement method for high salinity Ra samples is ICP-MS with sample dilution as necessary to reduce matrix effects.

07 ISOTOPE AND RADIATION SOURCES↗

Sample environment effects on synchrotron-measured temperature profiles in an approximant of optical floating zone crystal growth

Even though the growth of crystals using optical floating zone furnaces has had an immense scientific impact, the implementation of this method remains more of an art than a science due to the difficulty of obtaining quantitative information about the sample thermal profile during crystal growth. Building on recent work demonstrating that in situ synchrotron studies can be used to map sample rod temperatures during heating, investigations were carried out to better understand how the sample environment affects the sample temperature profile. Through a combination of experimental studies and modeling efforts, it is shown that the environment in the furnace can strongly influence the sample temperature at the lamp focus, the steepness of the vertical temperature gradient, and the timescale required for sample heating and cooling - effects which can combine to produce a strong history-dependence to sample temperature profiles. It is demonstrated that the furnace effects can be effectively captured in thermal models, allowing both the steady-state and time-dependent behavior of the sample to be accurately reproduced with predictive models, and providing a launching point for improved furnace designs that can more readily deliver desired thermal profiles.

36 MATERIALS SCIENCE↗

Automated Coupling of Nanodroplet Sample Preparation with Liquid Chromatography–Mass Spectrometry for High-Throughput Single-Cell Proteomics

Single-cell proteomics can provide critical biological insight into the cellular heterogeneity that is masked by bulk-scale analysis. Here, we have developed a nanoPOTS (nanodroplet processing in one pot for trace samples) platform and demonstrated its broad applicability for single-cell proteomics. However, because of nanoliter-scale sample volumes, the nanoPOTS platform is not compatible with automated LC-MS systems, which significantly limits sample throughput and robustness. To address this challenge, we have developed a nanoPOTS autosampler allowing fully automated sample injection from nanowells to LC-MS systems. We also developed a sample drying, extraction, and loading workflow to enable reproducible and reliable sample injection. The sequential analysis of 20 samples containing 10 ng tryptic peptides demonstrated high reproducibility with correlation coefficients of >0.995 between any two samples. The nanoPOTS autosampler can provide analysis throughput of 9.6, 16, and 24 single cells per day using 120, 60, and 30 min LC gradients, respectively. As a demonstration for single-cell proteomics, the autosampler was first applied to profiling protein expression in single MCF10A cells using a label-free approach. At a throughput of 24 single cells per day, an average of 256 proteins was identified from each cell and the number was increased to 731 when the Match Between Runs algorithm of MaxQuant was used. Using a multiplexed isobaric labeling approach (TMT-11plex), ~77 single cells could be analyzed per day. We analyzed 152 cells from three acute myeloid leukemia cell lines, resulting in a total of 2558 identified proteins with 1465 proteins quantifiable (70% valid values) across the 152 cells. These data showed quantitative single-cell proteomics can cluster cells to distinct groups and reveal functionally distinct differences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond Laser Desorption Postionization MS vs ToF-SIMS Imaging for Uncovering Biomarkers Buried in Geological Samples

The study of lipid molecular fossils by traditional biomarker analysis requires bulk sample crushing, followed by solvent extraction, and then the analysis of the extract by gas chromatography-mass spectrometry (GC–MS). This traditional analysis mixes all organic compounds in the sample regardless of their origins, with a loss of information on the spatial distribution of organic molecules within the sample. These shortcomings can be overcome using the chemical mapping of intact samples. Spectroscopic techniques such as UV fluorescence or Raman spectroscopy, laser ablation inductively coupled plasma mass spectrometry, and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are among those elemental and molecular mapping techniques. This study employed femtosecond (fs) laser ablation combined with single-photon ionization, a method called fs-laser desorption postionization mass spectrometry (fs-LDPI-MS). In this work, a pulsed ~75 fs, 800 nm laser was used to ablate the geological sample, which was then photoionized after a few microseconds by a pulsed 7.9 eV vacuum ultraviolet laser. An organic carbon-rich geological sample was used for this study to map hydrocarbon biomarkers in sediments that were previously studied by GC–MS. The petrography of this sample was examined by optical and fluorescence microscopy. It is demonstrated here that fs-LDPI-MS combined with petrography for multimodal imaging can expose buried compounds within the sample via in situ layer removal. When used in conjunction with traditional organic geochemical analysis, this method has the potential to determine the spatial distribution of organic biomarkers in geological material. Finally, fs-LDPI-MS imaging data are compared with ToF-SIMS imaging that is commonly used for such studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Block Design with Common Reference Samples Enables Robust Large-Scale Label-Free Quantitative Proteome Profiling

Label-free quantitative proteomics has become an increasingly popular tool for profiling global protein abundances. However, one major weakness is the potential performance drift of the LC-MS platform over time, which in turn limits its utility for analyzing large-scale sample sets. To address this, in this work we introduce an experimental and data analysis scheme based on a block-design with common controls within each block for enabling LC-MS-based large-scale label-free quantification. In this scheme, a large number of samples (e.g., >100 samples) are analyzed in smaller, and more manageable blocks, minimizing instrument drift and variability within a block. Furthermore, each designated block also contains common controls (or reference) samples for normalization within and across blocks. We demonstrated the effectiveness of this method by profiling the proteome response of human macrophage THP-1 cells to 11 engineered nanomaterials (ENMs) at two different doses. A total of 116 samples were analyzed in six blocks, yielding an average coverage of 4500 proteins per sample. The data revealed consistent quantification of proteins across all six blocks, as shown by highly stable quantification of house-keeping proteins in all samples and high levels of quantification correlation among samples from different blocks. The data also demonstrated that label-free quantification is robust and accurate enough to quantify even very subtle abundance changes as well as large fold-changes without potential ratio compression as often encountered with isobaric labeling. Our streamlined workflow is easy to implement and can be readily adapted to other large cohort studies for reproducible label-free proteome quantification.

59 BASIC BIOLOGICAL SCIENCES↗

Nanopipettes: probes for local sample analysis

Nanopipettes (pipettes with diameters <1 μm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 μm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗