Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “safety analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 757 records · Page 42

Semi-analytical prediction of hydraulic resistance and heat transfer for pipe and channel flows of water at supercritical pressure

Within the Generation IV International Forum the Supercritical Water Reactor is investigated. For its core design and safety analysis the efficient prediction of flow and heat transfer parameters such as the wall-shear stress and the heat-transfer coefficient for pipe and channel flows is needed. For circular pipe flows a numerical model based on the one-dimensional conservation equations of mass, momentum end energy in the radial direction is presented, referred to as a 'semi-analytical' method. An accurate, high-order numerical method is employed to evaluate previously derived analytical solutions of the governing equations. Flow turbulence is modeled using the algebraic approach of Prandtl/van-Karman, including a model for the buffer layer. The influence of wall roughness is taken into account by a new modified numerical damping function of the turbulence model. The thermo-hydraulic properties of water are implemented according to the international standard of 1997. This method has the potential to be used within a sub-channel analysis code and as wall-functions for CFD codes to predict the wall shear stress and the wall temperature. The present study presents a validation of the method with comparison of model results with experiments and multi-dimensional computational (CFD) studies in a wide range of flow parameters. The focus is laid on forced convection flows related to reactor design and near-design conditions. It is found, that the method can accurately predict the wall temperature even under deterioration conditions as they occur in the selected experiments (Yamagata el al. 1972 at 24.5 MPa, Ornatski et al. 1971 at 25.5 and Swenson et al. 1963 at 22.75 MPa). Comparison of the friction coefficient under high heat flux conditions including significant viscosity and density reductions near the wall with various correlations for the hydraulic resistance will be presented; the best agreement is achieve with the correlation of Pioro et al. 2004. It is concluded, that the semi-analytical prediction method is accurate and efficient for forced convection flows even at high heat fluxes. The wall-roughness height is identified as an important model parameter. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DOE 2009 occupational radiation exposure

The U.S. Department of Energy (DOE) Office of Corporate Safety Analysis (HS-30) within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE.* The DOE 2009 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with DOE Part 835 dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protection of individuals from the effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. The occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site over the past 5 years.

Source record↗

DOE 2008 occupational radiation exposure

The U.S. Department of Energy (DOE) Office of Corporate Safety Analysis (HS-30) within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE. The DOE 2008 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with DOE Part 835 dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protection of individuals from the effects of radiation. This report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. The occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site over the past 5 years.

Source record↗

Calculation of heating values for the high flux isotope reactor

Calculating the amount of energy released by a fission reaction (fission Q value) and the heating rate distribution in a nuclear reactor is an important part of the safety analysis. However, these calculations can become very complex. One of the codes that can be used for this type of analyses is the Monte Carlo transport code MCNP5. Currently it is impossible to calculate the Q value and heating rate disposition for delayed beta and delayed gamma particles directly from MCNP5. The purpose of this paper is to outline a rigorous method for indirectly calculating the Q values and heating rates in the High Flux Isotope Reactor (HFIR), based on previous similar studies carried out for very high-temperature reactor configurations. This method has been applied in this study to calculate heating rates for the beginning of cycle (BOC) and end-of-cycle (EOC) states of HFIR. In addition, the BOC results obtained for HFIR are compared with corresponding results for the Advanced Test Reactor. The fission Q value for HFIR was calculated as 200.2 MeV for the BOC and 201.3 MeV for the EOC. It was also determined that 95.1% and 95.4% of the heat was deposited within the HFIR fuel plates for the BOC and EOC models, respectively. This methodology can also be used for heating rate calculations for HFIR experiments. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification and Validation of CFD Simulations involving Twin Rectangular Jets using Steady RANS in Star-CCM+

Analyses such as component design and safety analysis can be conducted through careful application of computational fluid dynamics (CFD) codes. Before these codes can be considered ready for specific analysis, benchmarking (validation) against applicable datasets is needed. The twin jet water facility (TJWF) developed originally at the University of Tennessee, Knoxville has been purposed for aiding in this type of work. The TJWF allows for large data sets to be created using state of the art non-invasive measurement techniques within a mostly transparent testing volume. Utilizing velocity data collected in the TJWF by Wang et. al., the Star-CCM+ code was benchmarked a using steady Reynolds averaged Navier Stokes (RANS) framework for a combining two jet case. Careful efforts to properly conduct verification of the numerical work was undertaken with a sample reported in this summary. The computational results were validated against the experimental work and found to be within acceptable limits. The parameters of interest were the merging and combining points (MP and CP) of the twin jets, and the velocity profiles at increasing heights after injection. Fig.1 provides a graphical depiction of the twin jets combining within a free shear volume with key geometric factors included. The MP and velocity profiles were predicted with reasonable agreement. Whereas, the combining point of the twin jets was found to be over-predicted by {approx}24% difference. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

BALLISTICS TESTING OF THE 9977 SHIPPING PACKAGE FOR STORAGE APPLICATIONS

Radioactive materials are stored in a variety of locations throughout the DOE complex. At the Savannah River Site (SRS), materials are stored within dedicated facilities. Each of those facilities has a documented safety analysis (DSA) that describes accidents that the facility and the materials within it may encounter. Facilities at the SRS are planning on utilizing the certified Model 9977 Shipping Package as a long term storage package and one of these facilities required ballistics testing. Specifically, in order to meet the facility DSA, the radioactive materials (RAM) must be contained within the storage package after impact by a .223 caliber round. In order to qualify the Model 9977 Shipping Package for storage in this location, the package had to be tested under these conditions. Over the past two years, the Model 9977 Shipping Package has been subjected to a series of ballistics tests. The purpose of the testing was to determine if the 9977 would be suitable for use as a storage package at a Savannah River Site facility. The facility requirements are that the package must not release any of its contents following the impact in its most vulnerable location by a .223 caliber round. A package, assembled to meet all of the design requirements for a certified 9977 shipping configuration and using simulated contents, was tested at the Savannah River Site in March of 2011. The testing was completed and the package was examined. The results of the testing and examination are presented in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Managing Aging Effects on Dry Cask Storage Systems for Extended Long-Term Storage and Transportation of Used Fuel

The cancellation of the Yucca Mountain repository program in the United States raises the prospect of extended long-term storage (i.e., >120 years) and deferred transportation of used fuel at operating and decommissioned nuclear power plant sites. Under U.S. federal regulations contained in Title 10 of the Code of Federal Regulations (CFR) 72.42, the initial license term for an Independent Spent Fuel Storage Installation (ISFSI) must not exceed 40 years from the date of issuance. Licenses may be renewed by the U.S. Nuclear Regulatory Commission (NRC) at the expiration of the license term upon application by the licensee for a period not to exceed 40 years. Application for ISFSI license renewals must include the following: (1) Time-limited aging analyses (TLAAs) that demonstrate that structures, systems, and components (SSCs) important to safety will continue to perform their intended function for the requested period of extended operation; and (2) a description of the aging management program (AMP) for management of issues associated with aging that could adversely affect SSCs important to safety. In addition, the application must also include design bases information as documented in the most recent updated final safety analysis report as required by 10 CFR 72.70. Information contained in previous applications, statements, or reports filed with the Commission under the license may be incorporated by reference provided that those references are clear and specific. The NRC has recently issued the Standard Review Plan (SRP) for renewal of used-fuel dry cask storage system (DCSS) licenses and Certificates of Compliance (CoCs), NUREG-1927, under which NRC may renew a specific license or a CoC for a term not to exceed 40 years. Both the license and the CoC renewal applications must contain revised technical requirements and operating conditions (fuel storage, surveillance and maintenance, and other requirements) for the ISFSI and DCSS that address aging effects that could affect the safe storage of the used fuel. The information contained in the license and CoC renewal applications will require NRC review to verify that the aging effects on the SSCs in DCSSs/ ISFSIs are adequately managed for the period of extended operation. To date, all of the ISFSIs located across the United States with more than 1,500 dry casks loaded with used fuel have initial license terms of 20 years; three ISFSIs (Surry, H.B. Robinson and Oconee) have received their renewed licenses for 20 years, and two other ISFSIs (Calvert Cliffs and Prairie Island) have applied for license renewal for 40 years. This report examines issues related to managing aging effects on the SSCs in DCSSs/ISFSIs for extended long-term storage and transportation of used fuels, following an approach similar to that of the Generic Aging Lessons Learned (GALL) report, NUREG-1801, for the aging management and license renewal of nuclear power plants. The report contains five chapters and an appendix on quality assurance for aging management programs for used-fuel dry storage systems. Chapter I of the report provides an overview of the ISFSI license renewal process based on 10 CFR 72 and the guidance provided in NUREG-1927. Chapter II contains definitions and terms for structures and components in DCSSs, materials, environments, aging effects, and aging mechanisms. Chapter III and Chapter IV contain generic TLAAs and AMPs, respectively, that have been developed for managing aging effects on the SSCs important to safety in the dry cask storage system designs described in Chapter V. The summary descriptions and tabulations of evaluations of AMPs and TLAAs for the SSCs that are important to safety in Chapter V include DCSS designs (i.e., NUHOMS{reg_sign}, HI-STORM 100, Transnuclear (TN) metal cask, NAC International S/T storage cask, ventilated storage cask (VSC-24), and the Westinghouse MC-10 metal dry storage cask) that have been and continue to be used by utilities across the country for dry storage of used fuel to date. The goal of this report is to help establish the technical basis for extended long-term storage and transportation of used fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration and validation of NRC fuel performance models

FRAPCON and FRAPTRAN are the steady-state and transient fuel performance codes, respectively, that are used by the U.S. Nuclear Regulatory Commission (NRC) in performing confirmatory calculations of licensee fuel performance codes and safety analysis methods during the review and approval of these codes and methods for light-water reactors. The NRC also uses these codes to perform calculations to direct regulatory research and to assist in the development of new regulations and regulatory guides. FRAPCON and FRAPTRAN are well-validated fuel performance codes that are kept in a constant state of maintenance. FRAPCON and FRAPTRAN have an extensive database of separate effects data used to validate individual material property and fuel performance models and an integral effects database used to assess the overall code prediction within the full range of fuel operations. The key code predictions that are of regulatory interest as they relate to various specified acceptable design limits are: fuel and cladding temperature, rod internal pressure, cladding hoop strain, cladding corrosion and hydriding, and fission gas release. To assess the ability of the code to accurately predict these values, the integral assessment database consists of measurements of fuel centerline temperature, fission gas release, void volume, cladding corrosion, and cladding hoop strain. This paper will discuss the activities that are performed to ensure that FRAPCON and FRAPTRAN represent the state of the industry and will describe the separate effect and integral effect databases that are used to validate the models and are continually being expanded to ensure validation over the full range of fuel operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Standard Problems for CFD Validation for NGNP - Status Report

The U.S. Department of Energy (DOE) is conducting research and development to support the resurgence of nuclear power in the United States for both electrical power generation and production of process heat required for industrial processes such as the manufacture of hydrogen for use as a fuel in automobiles. The project is called the Next Generation Nuclear Plant (NGNP) Project, which is based on a Generation IV reactor concept called the very high temperature reactor (VHTR). The VHTR will be of the prismatic or pebble bed type; the former is considered herein. The VHTR will use helium as the coolant at temperatures ranging from 250°C to perhaps 1000°C. While computational fluid dynamics (CFD) has not previously been used for the safety analysis of nuclear reactors in the United States, it is being considered for existing and future reactors. It is fully recognized that CFD simulation codes will have to be validated for flow physics reasonably close to actual fluid dynamic conditions expected in normal operational and accident situations. The “Standard Problem” is an experimental data set that represents an important physical phenomenon or phenomena, whose selection is based on a phenomena identification and ranking table (PIRT) for the reactor in question. It will be necessary to build a database that contains a number of standard problems for use to validate CFD and systems analysis codes for the many physical problems that will need to be analyzed. The first two standard problems that have been developed for CFD validation consider flow in the lower plenum of the VHTR and bypass flow in the prismatic core. Both involve scaled models built from quartz and designed to be installed in the INL’s matched index of refraction (MIR) test facility. The MIR facility employs mineral oil as the working fluid at a constant temperature. At this temperature, the index of refraction of the mineral oil is the same as that of the quartz. This provides an advantage to the optics used for data gathering. Particle image velocimetry (PIV) is used to take the data. The first standard problem represents several flow physics expected to be present in the lower plenum of the prismatic VHTR. In the lower plenum, heated helium coolant in the form of jets issues downward into the plenum and is then forced to turn ninety degrees and flow toward the exit duct. The lower plenum is filled with cylindrical graphite posts that hold up the core. Figure S-1 provides a plan view of the lower plenum. The red circles represent support posts holding up columns of heated blocks. Grey circles represent support posts under columns of reflector blocks. Helium enters the lower plenum at the junctions of the hexagonal blocks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diffusion velocity correlation for nuclear graphite gasification at high temperature and low Reynolds numbers

The safety analysis of High-Temperature and Very High Temperature gas-cooled Reactors requires reliable estimates of nuclear graphite gasification as a function of temperature, among other parameters, in the unlikely event of an air ingress accident. Although the rates of the prevailing chemical reactions increase exponentially with temperature, graphite gasification at high temperatures is limited by the oxygen diffusion through the boundary layer. The effective diffusion velocity depends on the total flow rate and pressure of the bulk air-gas mixture. This paper develops a semi-empirical Sherwood number correlation for calculating the oxygen diffusion velocity. The correlation is based on a compiled database of the results of convective heat transfer experiments with wires and cylinders of different diameters in air, water and paraffin oil at 0.006 {<=} Re {<=} 1,604 and 0.068 {<=} Sc {<=} 35.2, and of mass transfer experiments at 4.8 {<=} Re {<=} 77 and 1,300 {<=} Sc {<=} 2,000. The developed correlation is within {+-} 8% of the compiled database of 567 data points and consistent with reported gasification rate measurements at higher temperatures in experiments using different size specimens of nuclear graphite grades of NBG-18 and NB-25, IG-11, IG-110 and IG-430 in atmospheric air at 0.08 {<=} Re {<=} 30. Unlike the Graetz solution that gives a constant Sh of 3.66 at Re {<=} 1.0, the present correlation shows Sh decreases monotonically to much lower values with decreasing Re. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using Correlations to Cs-137 to Reduce Uncertainty in SRS Tank Farm Tc-99 and I-129 Inventories - 19266

Performance Assessment (PA) modeling of the Saltstone Disposal Facility (SDF) shows that iodine-129 (I-129) dominates peaks of potential future doses, followed by contributions from technetium-99 (Tc-99). While these radionuclides are important from a PA perspective, they are relatively unimportant from a safety analysis or occupational exposure perspective. As such, the storage of Tc-99 and I-129 within liquid waste at Savannah River Site (SRS) have not been well tracked, resulting in considerable uncertainty in the estimated inventories of Tc-99 and I-129 used for PA modeling. Alternatively, cesium-137 (Cs-137) is considered a high-risk radionuclide from an occupational exposure perspective and is well characterized. Within the liquid waste at SRS, analyses have shown that concentrations of Cs-137 are closely correlated to both Tc-99 and I-129. These correlations and the abundance of Cs-137 data were leveraged to significantly reduce inventory uncertainty for waste destined to be disposed at the SDF. Previous attempts to mathematically define these correlations had two flaws: (1) the defined correlations failed to address the impact of the relatively short half-life of Cs-137 compared to the long half-lives of Tc-99 and I-129, and (2) the analyses relied on a small number of samples. To address the issue of the decay rate from the short half-life, all Cs-137 concentrations were decayed to a single future date. To improve the number of samples used to develop the correlations, a literature review was performed resulting in a larger data set. The data underwent a validation process, then the correlations were updated. The resulting correlations were used to improve inventory estimates for Tc-99 and I-129 for an ongoing revision to the SDF PA. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RELAP5-3D Resolution of Known Restart/Backup Issues

The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequential verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Emergency Argon on FCF Operational Incidents

The following report presents analyses of operational incidents which are considered in the safety analysis of the FCF argon cell and the effect that the operability of the emergency argon system has on the course of these incidents. The purpose of this study is to determine if the emergency argon system makes a significant difference in ameliorating the course of these incidents. Six incidents were considered. The following three incidents were analyzed. These are: 1. Cooling failing on 2. Vacuum Pump Failing on 3. Argon Supplies Failing on. In the remaining three incidents, the emergency argon supply would have no effect on the course of these transients since it would not come on during these incidents. The transients are 1. Loss of Cooling 2. Loss of power (Differs from above by startup delay till the Diesel Generators come on.) 3. Cell rupture due to an earthquake or other cause. The analyses of the first three incidents are reported on in the next three sections. This report is issued realizing the control parameters used may not be optimum, and additional modeling must be done to model the inertia of refrigeration system, but the major conclusion concerning the need for the emergency argon system is still valid. The timing of some events may change with a more accurate model but the differences between the transients with and without emergency argon will remain the same. Some of the parameters assumed in the analyses are Makeup argon supply, 18 cfm, initiates when pressure is = -6 iwg., shuts off when pressure is = -3.1 iwg. 170,000 ft3 supply. Min 1/7th always available, can be cross connected to HFEF argon supply dewar. Emergency argon supply, 900 cfm, initiates when pressure is = -8 iwg. shuts off when pressure is =-4 iwg. reservoir 220 ft3, refilled when tank farm pressure reduces to 1050 psi which is about 110 ft3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurements of Hydrogen Generation Rates using a Sealed Reactor System - 19428

Sealed reactor tests were performed to measure the hydrogen generation rate (HGR) from stored radioactive waste at the Savannah River Site. HGR may be very low, on the order of 7.5 x 10{sup -13} (m{sup 3}/h)/L [that is, cubic meters of H{sub 2} generated per hour per liter of radioactive liquid waste, or 10{sup -10} (ft{sup 3}/h)/gal]. Because the estimated HGR limit of detection for an open, continuous flow, system is approximately 7.5 x 10{sup -10} (m{sup 3}/h)/L [or 10{sup -7} (ft{sup 3}/h)/gal], a more sensitive method was needed. By accumulating generated gasses in a sealed system without a continuous purge gas, the resulting concentrations can increase the sensitivity of measurement, which is based on time of heating. In 2017, Savannah River Remediation declared a Potential Inadequacy in the Safety Analysis related to the potential thermal decomposition of organics that generate hydrogen in each of three Liquid Waste facilities: Concentration, Storage and Transfer Facility, Saltstone Production Facility, and the Defense Waste Processing Facility. The research for this study concerns low activity waste of Tank 50, which feeds the Saltstone Production Facility. This study evaluated the impact of organics including formate on the generation of H{sub 2}. Samples of SRS Tank 50 waste, which is a nominal 5 molar sodium salt solution, were sealed in stainless steel reactors and held at varying temperatures, e.g., 50 deg. C, 75 deg. C, 100 deg. C, and 120 deg. C, to determine if organic compounds are decomposing into H2. The experiments included trace solids used to stabilize waste in grout, e.g., grout-premix and Blast Furnace Slag, to determine if any solid phase reactions are present, which would accelerate or inhibit the generation of H{sub 2} at these temperatures. This paper describes the sealed reactors designed and constructed at Savannah River National Laboratory and the radioactive tests that were performed to measure HGR in both oxic and anoxic atmospheres. The shakedown tests showed the sealed reactors to be leak tight and hydrogen concentrations from calibrated standards could be accurately measured. Previous simulant tests helped to perfect the test methods and better design the radioactive tests. The radioactive results showed that the rate of hydrogen generated from Tank 50 waste, over a range of temperatures from 30 deg. C up to 120 deg. C, is bounded by an empirical relation (Hu Equation) that can be used to approximate HGRs in Tank 50 radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Proposed Correlation for Critical Flow Rate of Steam/Water Flow

In the safety analysis of loss-of-coolant-accident (LOCA) and steam generator tube rupture (SGTR) scenarios of light water reactors, a modeling of a break is very important to predict the accident's result. For example, the design of a break simulator to simulate a LOCA in light water reactors requires accurate knowledge of the leakage flow through the break, whose shape can be assumed as an orifice or a nozzle according to the characteristics of the break shape. In the case of a small-break LOCA (SBLOCA) scenario, the critical flow mostly occurs by sub-cooled and saturated liquid water including a two-phase water flow at relatively high-pressure conditions. Among previous critical flow maps, Moody's maps are well known for their critical flow rate and pressure of a single component and two-phase mixture with respect to the upstream enthalpy and pressure. In Moody's model, a slip ratio defined by maximizing the critical flow rate with respect to the slip ratio was introduced, and thus its predictions tended to be too conservative. Later, Moody suggested other maps based on a homogeneous equilibrium model (HEM), and they were useful to predict a choked condition for a given upstream condition. However, their predictions of the critical flow rate seemed to show quite an underestimation compared to various test data. The author suggested more practicable critical flow maps for a critical mass flux and pressure of a steam-water flow with respect to the upstream stagnation conditions using an extended Henry-Fauske model. From a comparison with the selected test data, suggested maps showed conservative predictions within reasonable ranges. In this report, a new correlation for the critical flow rate was developed to simulate the suggested critical flow maps within a reasonable range of error. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Decommissioning of obsolete Nuclear Facilities in the UJV Rez, a. s. - 19027

UJV Rez, a. s. (further also UJV) is a leading institution in all areas of nuclear R and D in the Czech Republic and has had a dominant position in the nuclear program since it was established in 1955 as the Nuclear Research Institute Rez. The activities of UJV encompass nuclear physics, chemistry, nuclear power and many other topics. The main issues addressed at UJV in past decades have included research, development and services for NPPs, the fuel cycle and irradiation services for research and development in the industrial sector and medicine. UJV also manages most institutional radioactive wastes (RAW) produced in the Czech Republic (approx. 90 %). After more than 60 years of activities of the UJV in the nuclear field, there were obsolete nuclear facilities to be decommissioned. Decommissioning of nuclear facilities UJV is the only ongoing decommissioning project in the Czech Republic. Preparations for decommissioning began in 1996. Safety analysis report (SAR) was performed comprising the identification and characterization of potential sources of risk, potentially exposed receptors and exposure pathways, potential chemical compounds, radionuclides and media of concern. The results of the SAR enabled to determine the priorities of the decommissioning, the decommissioning the expenses and as well as project implementation. The decommissioning project was revised on the base of information obtained during decommissioning. The decommissioning was divided into two phases according to the level of risk and the financing limitations. The Ministry of Finance significantly financially contributed the decommissioning, although the UJV also contributed a considerable amount. Overall cost is close to the amount of Eur 27 million. Decommissioning started in 2003 and will be finished in 2018. Almost all facilities have already been successfully decommissioned. In the following table, the status of decommissioning of facilities is described. 1) Reloading site for RAW storage (Building 211/6): last item in progress 2003 - 2018; 2) Special Sewage System: decommissioned 2004 - 2005, reused; 3) Liquid RAW storage tanks (Building 211/3): decontaminated 2004 - 2013, reused; 4) Technology for RAW treatment (Building 241): decommissioned 2003 - 2011; 5) Contaminated equipment (Building 250): decommissioned 2003 - 2016; 6) Systems for storage of sealed sources (Building 261); decommissioned 2003 - 2005; 7) Decay tanks (Building 211/5); decommissioned 2003 - 2014, reused; 8) Old bituminating unit (Building 211/3); decommissioned 2004 - 2008; 9) Surface RAW storage site; decommissioned 2009 - 2014. Later, other unused decommissioning facilities, which were not included in the decommissioning project financed by the state, were included. These facilities are continuously decommissioned and financed from own resources of UJV. These facilities are like facilities already decommissioned: radiochemical laboratories, (including glove boxes), liquid RW storage tanks (including sewage systems), liquid RW treatment technology, hot cells, accumulated RW, etc. Realization started 2016 and expected duration is till 2026. Estimated budget is approximately Eur 17 million. The decommissioning of nuclear facilities in UJV is being carried out on the high level of radiation protection and up to now there was no extraordinary event or accident, although some challenges we were forced to address. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Foaming Solutions for High Level Waste (HLW) Processing - 20195

Foaming occurs during treatment of high level waste (HLW) at Savannah River Site's Defense Waste Processing Facility (DWPF) in the Chemical Process Cell (CPC) due to high gas generation from process steam and chemical offgas products [1]. The presence of amphiphilic particles in the waste slurry stabilizes the foam [2], [3]. Efficient processing of HLW requires foam control, as foam-overs lead to lower productivity and potential radioactive contamination of condensate streams. DWPF currently employs Siovation Antifoam 747, a surfactant produced by Momentive Performance Materials, as an antifoaming agent during waste treatment. Despite its ability to control foam generation, processing issues have arisen from its use [4]. During DWPF chemical processing, a chemical antifoam agent must be effective at temperatures up to 103 deg. C between pH 3-13. Antifoam 747 is effective at pH 7 but degrades as pH deviates [5]. Antifoam 747 is 90% by weight Momentive{sup TM} L77 and 10% by weight Momentive{sup TM} Y-17580. These ingredients are trisiloxane products, which are especially vulnerable to attack in acidic and caustic environments. Since Antifoam 747 readily degrades, periodic addition is required. Several processing concerns related to Antifoam 747 have affected DWPF operation. Its overuse warranted concern of potential flammable melter offgas under upset conditions due to the generation of carbon dioxide and hydrogen. As a result, a Potential Inadequacy in the Safety Analysis (PISA) was declared [6]. Antifoam contribution has been included in the melter offgas flammability strategy and the quantity of antifoam is monitored to ensure limits are not exceeded. Testing at Savannah River National Laboratory (SRNL) determined that propanal, tri-methylsilanol, and hexamethyldisiloxane are generated as Antifoam 747 degrades, leading to a second PISA [7]. The formation of these byproducts poses additional flammability risks. Furthermore, the methyl and ethyl groups of these compounds may be responsible for the formation of the methyl and ethyl mercury discovered in DWPF [8], [9]. The formation of organomercury has specifically been called out by DOE as a need for increased research. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoam agents were evaluated as part of an effort to improve HLW treatment operations at DWPF and to reduce, or eliminate, the flammability hazards associated with Antifoam 747 currently in use. Foaming of high-level waste (HLW) slurries is an issue at the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) which is currently mitigated with a chemical antifoam agent. The effectiveness of non-chemical methods for foam control and the efficiency of alternative antifoams were examined to improve HLW treatment at DWPF and to eliminate the flammability hazards associated with Siovation Antifoam 747 currently in use. Non-chemical foam control methods were deemed unviable for chemical processing at DWPF, as the spray/mist technique requires too much water and space limitations make installation and implementation of headspace agitators unfeasible. The use of ultrasonic energy thickened and further stabilized the foam. Two suitable alternative defoaming agents, Momentive{sup TM} Y- 17112 and Evonik Surfynol{sup R} MD-20, were identified. Both defoamers control foam over a pH range of 4- 13 at boiling, with no flammable degradation products, and only minimal quantities (100-200 mg/kg) are required under glycolic acid conditions. In order to validate the effectiveness of these defoaming agents, SRNL recommends irradiation testing and laboratory scale SRAT/SME experiments with actual radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH Packaging Program Guidance (Rev. 3)

The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the Remote Handled-Transuranic (RH-TRU) 72-B Waste Shipping Package (also known as the "RH-TRU 72-B") and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: "...each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application." It further states: "...each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application." Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M&O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) §71.8, "Deliberate Misconduct." Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, "Packaging and Transportation of Radioactive Material," certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, "Reporting of Defects and Noncompliance," regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations are conducted. This document details the instructions to be followed to operate, maintain, and test the RH-TRU 72-B packaging. This Program Guidance standardizes instructions for all users. Users shall follow these instructions or equivalent approved instructions. Following these instructions assures that operations meet the requirements of the SARP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗