Verification and Validation of a Modified Numerical Algorithm for Simulation of Transient Unconfined Groundwater Flow
This report extends verification and validation testing of the NUFT package of codes (Nitao 2000a,b) to the US1P module of code designed for simulation of single-phase mixed or “coupled” saturated and unsaturated (or “variably saturated”) groundwater flow. Importantly, the verification and validation testing of US1P in this report includes performance evaluation of a modified numerical algorithm that was not included in prior quality assurance (QA) of the NUFT package by Carle et al. (2014) for Underground Test Area (UGTA) project activities, which are directed at assessment of radionuclide contamination in groundwater sourced from underground nuclear test locations at the Nevada National Security Site (NNSS). An immediate purpose of this report is to provide QA for ongoing large-scale, three-dimensional (3-D) groundwater flow modeling of transient water levels associated with longterm water supply pumping and underground nuclear testing at the NNSS (Jackson and Fenelon, 2018; Jackson et al., 2021). For UGTA activities, the QA refers to the standards of ASTM (1996) for verification and validation testing of groundwater modeling codes.